I n t r o d u c t i o n
The CAP 2020 DR IB is a proximity card and/or keypad based access control device ith internal bell, part of
the CIB-tech automation system.
The unit can control bi-directional access through one door. It accepts up to 1024 users and provides entry
via the use of proximity cards and/or PIN codes. It has an internal bell that orks ith proximity card readers
ith bell button.
Additional Equipment Required
1. Functional CIB-tech system
A minimal number of essential CIB-tech components to make a functional CIB-tech system1
2. Proximity card and/or PIN code reader with ell utton, for entry request
A proximity card and/or PIN code reader ith a 26-bit Wiegand-type output, further referred to as
“Reader A” 2. Note that the proximity card reader must supply bell button event in Wiegand data
format.
3. Request to Exit (REX) utton or proximity card and/or PIN code reader for exit
request (optional)
Either a proximity card and/or PIN code reader ith a 26-bit Wiegand-type output, further referred to
as “Reader B”, or a normally-open type (contact is closed hen button is pressed) REX button can
be used as a request-to-exit device2.
4. Open door sensor (optional)
Normally open or normally closed type ith voltage free contacts 2.
5. Electric door lock
Fail safe (po er to lock) or fail secure (po er to open) strike lock/door bolt/magnetic lock2.
6. Power supply for electric door lock
Refer to the electric door lock's characteristics to choose a suitable po er supply. A po er supply
ith battery backup is recommended.
T e c h n i c a l S p e c i f i c a t i o n s
Electrical characteristics
●Power Supply
The CAP 2020 DR IB functions as a node in a CIB-tech system, being po ered from the CIB-tech
system's po er supply via the CIB-tech connectors.
○Operating voltage range: 20 to 28V DC (nominal 24V DC)
○Supply current
■Standby current ( ithout readers attached): 22mA
■Maximum current ( ithout readers attached): 50mA
■Typical standby current ( ith t o readers attached): 140mA
■Absolute maximum current ( ith t o readers attached): 300mA
●Power output
The CAP 2020 DR IB can provide po er to the proximity card and/or PIN code readers.
○Output voltage: 12V DC
1 See “CIB-tech installation manual” for details.
2 See “Recommended equipment to be used with CIB-tech” for details
CAP 2020 DR IB ©2009 - Intelligent Building Solutions 1

○Maximum output current: 2 x 170mA
●Relay output (for electric door lock)
If an electric door lock ith a DC po er supply is used, an external suppressor diode must be used3.
○Rated voltage: 24V AC/DC
○Rated current: 2A
●Signal Input
○Wiegand data input:
■supported input voltage levels: 0 - 5V
■input impedance: 1KOhm
○Open door sensor: N.O. or N.C. ith voltage free contacts
○REX button: N.O. ith voltage free contacts
●Signal Output
○External LED control:
■output voltage levels: 0 - 5V
■output current: 15mA
Mechanical characteristics
The CAP 2020 DR IB has a standard 3-module ide enclosure for M36 type DIN-Rail
●Dimensions: 96mm W x 52mm L x 60mm D
●Weight: 115g
Environmental characteristics
●Operating temperature: 0ºC to 65ºC
●Storage temperature: -10ºC to 70ºC
IBS product PS 121 D is a dedicated power supply for door locks: 12V AC and DC output, internal suppressor
diode. Note that battery backup for door lock is not possible with it.
Please verify whether it is suitable for your door lock!
CAP 2020 DR IB ©2009 - Intelligent Building Solutions 2

K e y F e a t u r e s
●Programmable via the CIB-tech system ith dedicated soft are
●Controls unidirectional or bi-directional access through one door
●Built in beeper for bell function
●Provides access for up to 1024 users
●Users may be members of one of up to 30 groups ith different access rights, based on a eekly
schedule. Groups have individual access right expiration dates
●Support for a REX button, or proximity card and/or PIN cod reader for exit request
●Support for an open-door sensor input for detecting actual door openings
●Internal battery po ered real-time clock. Clock keeps running in case of po er failure
●Internally stored 1024-entry access log ith time stamps
●Internally stored 1024-entry open door event log ith time stamps
●Configurable relay output; normal-open or normal-closed (in po er-off state relay contacts are
al ays open);
●T o functional modes: open door momentarily or toggle door state
●Configurable keep-door-open time for the momentary-open mode
●Relay output remotely controllable via the CIB-tech system
●Internal bi-color LED indicating the state of the door lock (green: closed / red: open)
●Support for t o external LEDs (for reader A and reader B) indicating a valid proximity card or PIN
code
I n s t a l l a t i o n
The CAP 2020 DR IB is meant to be installed on a standard M36 type DIN-Rail.
Part description
●Bus connectors:
○4P4C modular jack connectors for CIB-tech connection1
●Sys utton:
○pushbutton for CIB-tech system configuration
●EOL jumper:
○CIB-tech system's End Of Line jumper1
●LED:
○indicator LED for door lock state (green: closed / red open)
●DIN-rail release lever:
○lever for removing the device from the M36 DIN-Rail
●Terminal lock: terminals for connecting external devices
1. Reader B – LED control
2. Reader B – Wiegand data 1
3. Reader B – Wiegand data 0 / REX input
4. Reader B – DC po er supply +12V
5. Reader B – DC po er supply ground
6. Reader A – LED control
7. Reader A – Wiegand data 1
8. Reader A – Wiegand data 0
9. Reader A – DC po er supply +12V
10. Reader A – DC po er supply ground
11. Open-door sensor input
12. Relay contact 1
13. Relay contact 2
1 See “CIB-tech installation manual” for details.
CAP 2020 DR IB ©2009 - Intelligent Building Solutions 3

Wiring diagrams
Connection to CIB-tech system:
Use the CAP 2020 DR IB device's t o 4P4C modular jack connectors to connect it to the CIB-tech systems
(chain like) bus. Do not forget to remove the EOL jumper if the device is not the last element of the chain1;
1 See “CIB-tech installation manual” for details.
CAP 2020 DR IB ©2009 - Intelligent Building Solutions 4
0v DC
24v DC
BUS-L
BUS-H
0v DC
24v DC
BUS-L
BUS-H
CAP 2020 DR IB
LED
Bus connectors
EOL jumper
Terminal block
Din-rail release lever
1 1312111098765432
Sys button
1 1312111098765432
Terminal block
Sys button
EOL jumper
Bus connectors

Connecting the input devices
Connection example for t o proximity card / PIN reader:
CAP 2020 DR IB ©2009 - Intelligent Building Solutions 5
CAP 2020 DR IB
1 1312111098765432
LED
D1
D0
+12V
GND
Reader A
LED
D1
D0
+12V
GND
Reader B
(optional)
Open door sensor
(optional)

Connection example for one proximity card / PIN reader and REX button:
NOTE: Some proximity card / PIN readers don't have a LED control input. For these readers the LED control
output of the CAP 2020 DR IB is not connected.
Some proximity card / PIN readers have auxiliary inputs and outputs (ex. tamper, auxiliary led). These
auxiliary inputs and outputs can not be connected to the CAP 2020 DR IB.
CAP 2020 DR IB ©2009 - Intelligent Building Solutions 6
CAP 2020 DR IB
1 1312111098765432
LED
D1
D0
+12V
GND
Reader A
Open door sensor
(optional)
REX
(optional)

Connecting the electronic door lock
Connection example for AC-type electronic door lock:
Connection example for DC-type electronic door lock:
NOTE: An external suppressor diode (ex. 1N4001) is required.
CAP 2020 DR IB ©2009 - Intelligent Building Solutions 7
CAP 2020 DR IB
1 1312111098765432
Electronic door lock
(fail safe or fail secure)
type 12/24V AC
Line
transformer
12/24V AC 230V AC
CAP 2020 DR IB
1 1312111098765432
Electronic door lock
(fail safe or fail secure)
type 12/24V DC
DC power
supply
12/24V DC 230V AC
+
-
Suppressor diode
-
+

Connection example for DC-type electronic door lock and PS1213D, dedicated po er supply :
Document Version 1.0
Technical Support:
http:// .ibs-smarthouse.com/
All trademarks used in this document are properties of their respective o ners.
The manufacturer reserves the right to change the technical features of this product ithout prior notice.
CAP 2020 DR IB ©2009 - Intelligent Building Solutions 8
CAP 2020 DR IB
1 1312111098765432
Electronic door lock
(fail safe or fail secure)
type 12V DC
230V AC
PS 1213 D
1 765432
8 14131211109
- +
Table of contents
Other Intelligent Building Solutions IP Access Controllers manuals