Intelligent Home DT-AKP User manual

User Manual
RF CARD
DT-ENG-AKP-V1 / 201701
• Pleasereadthismanualcarefullytoensuresafeandcorrectoperation.
• Keepthismanualwellforfuturereference.
DT-AKP
2 WIRE SYSTEM
Access keypad panel with scramble keypad

-1-
1.Parts and Functions
1
2
5
4
6
3
7
8
9
2.Terminal Descriptions
L2
EB+
EB-
NO
LK+
LK-
+12V
L1
BUS
SD Card Slot
CN-LK
[1] Front panel
[2] Touch sensitive digital
keypad
[3] LED1 indicator
[4] LED2 indicator
[5] LED3 indicator
[6] ID card window
[7] Mounting hook
[8] Connection port
[9] Screw hole
•SD Card Slot: To insert micro SD card.
•BUS: Connect to the bus line, non polarity.
•+12V: 12VDC power output.
•LK+: Common contact of the relay.
•LK-: Power ground.
•NO: Normally open contact of the relay.
•EB+: Exit button power(+) output.
•EB-: Exit button power(-) output.

-2-
3.Mounting
1 2
43
Use the screws to fix the mounting bracket to the wall.
Attach the panel to the mounting bracket. Use the screwdriver and the screw to fix the panel.
Connect the cable correctly.
4.Electric Lock Connection
4.1 Internal Power Supply Mode
Use the power of the system to supply for the electronic lock, so that the lock can be
connected to the access keypad panel directly, without an additional power supply for the
electronic lock. Note that the access keypad panel can only output 12Vdc power, therefore the
kind of lock is limited.

-3-
•The rated power of the lock must be less than 12Vdc 300mA when using internal power
supply mode.
•The GND must connect to the negative of the lock, and the COM connect to the positive .
•The default unlock time is 3s. If different unlocking time is needed to be configured,
change the Unlock Timing on access keypad panel.
12V 300mA
+
-+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Set Unlock Relay mode
to Normally Open(0)
A. Connection for Power-on-to-Unlock type:
12V 300mA
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
+
-
Set Unlock Relay mode
to Normally Closed(1)
B. Connection for Power-off-to-Unlock type:
4.2 External Power Supply Mode
When the electronic lock is over 12 Vdc, external power supply for the lock is needed.
•The power supply for the lock must be less than 48Vdc 1.5A.
•The default unlock time is 3s. If different unlocking time is needed to be configured,
change the Unlock Timing on access keypad panel.
+
+
-
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Set Unlock Relay mode to
Normally Open(0)
Note: Cut off this line when
using external power supply
C. Connection for Power-to-Unlock type:

-4-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Set Unlock Relay mode to
Normally Closed(1)
+
+
-
-
Note: Cut off this line when
using external power supply
D. Connection for Power--off-to-Unlock type:
5. Functions Setup
This section explains the settings of each parameter,please refer to the following table:
About the setting mode:
Input the master code to enter the setting mode, and input the corresponding setting code to perform the settings
for the function you want. After settings have been made, input the following setting codes to continue the setting
operation. Press " " to exit the setting mode.
•The example is set as cancel button and # as conrm button, please refer to */# function
setting for detail information.
•Forbid sliding touch to the digital keypad, it may cause mistaken key, the correct operation is
using your nger to press the digital you desired.
• You should press“conrm”button after nish inputting the code number each time, otherwise,
the operation will be canceled automatically after 10s.
Order Setting items Setting code Setting range Default value
1 Reset all settings 00 -1,2,3,4
2 Set master code 01 1 ~ 12 digits
Valid keys:0 ~ 9 1234
3Set digitron display
mode(in standby mode) 02 Valid keys:0 ~ 2 0
5.1 Setting Items and Codes

-5-
4 Set unlock time 03 1 to 99 seconds 1 seconds
5 Set unlock mode 04 0:opened/1:closed opened
6Set touch key prompt
mode 05 0:ashing / 1: beep /
2:ashing + beep 2
7 Reset code settings 06 -1,2,3,4
8&# function settings 07 0:Normal/1:Reverse Normal
9 Tone select 08 0:Disable/1:Enable 1
10 Interference resistant
grade settings 09 Valid keys:0 ~ 5 3
11 Keyboard mode 10 0:standard / 1:scramble 1
12 Unlock work mode 11 Valid keys:0~3 0
13 Backup(master / user
card / password / tone) 12 -1,2,3,4
14 Update(master / user
card / password / tone) 13 -1,2,3,4
15 Device Address 14 Valid keys:0~3 0
16 RLC Control 15 Valid keys:0~4 0
17 Temporary(single use
only) password for relay1 18 Valid keys: 0 - 9 -
18 Temporary(single use
only) password for relay2 19 Valid keys: 0 - 9 -
19 Set the code for user
group 1 20-59 Valid keys: 0 - 9 -
20 Set the code for user
group 2 60-99 Valid keys: 0 - 9 -
21 Register [Manage card] 100 -1,2,3,4
22 Add user card 101 -1,2,3,4
23 Delete user card 102 -1,2,3,4
24 Format user card 103 -1,2,3,4

-6-
5.2 LED Indicator Denitions
5.3 Digitron Display Prompt
Indicator Status Description
LED1 Light on Release the rst/second lock
LED2
Light on Register [Add Manage card] / Add user card
Flash Register [Delete Manage card] / Delete user card
Double ash Format or Conguration switching of DT-ACC and ID card, it waits for
conrmation
LED3
Light on Setting code
Flash Setting value
Digitron display Prompt
OP1 Release the rst lock
OP2 Release the second lock
SUC Setting success
Err Password error / Non-access card
Err
1Setting code input error
Err
2Setting value input error
Err
3Cards have reached the number of rated
Err
4Input rule error

-7-
Err
5Wrong password 10 times in a row, is locked
Err
6Swipe invalid user card(When unlocking need swipe valid user card and password )
ACC The access control is congured for the DT-ACC application
ID The access control is congured for the ID card unlock application
S-A Register [Add Manage card]
S-D Register [Delete Manage card]
ADD Add user card
DEL Delete user card
CLE Format user card
BC1 Backup [Manage card]
BC2 Backup user card
BC3 Backup unlock password
BC4 Backup ringtones
UD1 Update [Manage card]
UD2 Update user card
UD3 Update unlock password
UD4 Update ringtones

-8-
Input the master code.
(Default: [ ] +[#] )
- All settings will restore to their
default value.
- The master code is allowed 1~12
digits,the same code cannot be set
for both the user code and the
master code,it is recommended
that you modify the default master
code.
- The unlock time can be set on
access keypad panel, and the
valid value is the number you set
last time.
(on)(off)(off)
LED1 LED2 LED3
Beep+, Beep
Beep+, Beep Beep+, Beep Beep+, Beep Beep+, Beep
Beep+
Inputting of value(ex.: 0)
range:0~2
Inputting of value (ex.: 09)
range:01~99
3.Set digitron
display mode
4.Set unlock time
(Default: 1s)
2.Set master code
(Default 1234)
Inputting of new master code
(ex.: 4321)(1~12 digits)
Input the setting code.
Inputting of code.
Input the setting code.
1.Reset all settings
00+#
1234+# 4321+#
01+#
0+# 09+#
Input the setting code.
02+#
Input the setting code.
03+#
- Digitron display mode:
0 : The scrolling display;
1 : All digitron display “-” sign;
2 : Only the upper left corner of the
digitron display “-” sign.
-
When the “ cancel” key is pressed, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
-
When there isn’t any operation within 10s, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
Beep, Beep+
*
(flash)(off)(off)
LED1 LED2 LED3
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
(off)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
(flash)(off)(off)
LED1 LED2 LED3
(flash)(off)(off)
LED1 LED2 LED3
(flssh)(off)(off)
LED1 LED2 LED3
5.4 Setting Steps

-9-
Input the master code.
(Default: [ ] +[#]) Beep+, Beep
7.Reset code setting 8. &# function setting6.Set touch key
prompt mode (Default Normal)(Default 0(opened))
Input the setting code.
Inputting of value
Input the setting code.
5.Set unlock mode
04+# 05+#
range:0:(open)/1:(close)
1+#
0/1 0/1
1+# 1+#1234+#
Input the setting code.
06+#
Input the setting code.
07+#
(ex.: 1)
Inputting of value Inputting of code Inputting of value
range:0~2
(ex.: 1)
range:0:(normal)/1:(reverse)
(ex.: 1)
*
*
*
- The unlock mode can be set on
access keypad panel, and the
valid value is the number you set
last time.
- Cancel all the passwords except
the master code.
- Restore the master code to
default value(1,2,3,4)
- When the item is set to 0, press
the button to cancel the input,
and press the # button to confirm
the input.
- When the item is set to 1, press
the # button to cancel the input,
and press the button to confirm
the input .
(on)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
-
When the “ cancel” key is pressed, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
-
When there isn’t any operation within 10s, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
Beep, Beep+
*
(off)
(off)(off)
LED1 LED2 LED3
- When it is set to 0, pressing the
touch key will blink one time.
- When it is set to 1, pressing the
touch key will sent out a sound of
beep.
- When it is set to 2, pressing the
touch key will blink one time and
sent out a sound of beep.

-10-
Input the master code.
(Default: [ ] +[#])
10.Interference resistant
grade setting
Input the setting code.Input the setting code.
9. Tone select
08+#
0/1 0/1
1+#
09+#
Inputting of value (ex.: 3)
range:0~5
3+#
Inputting of value (ex.: 1)
range:0(disable)/1:(enable)
(Default 3)
(Default 1(enable))
-
The larger you set the
interference resistant grade,
the stronger it will be, but the
sensitivity of the keypad will
be more lower.
-
If the item is set to 0, when unlock,
the system will sent out a sound of
Beep+.
- If the item is set to 1, when unlock,
the system will sent out a sound of
“Door is open”.
-
If the item is set to 0, the
keypoard display mode is
standard mode.
- If the item is set to 1, the
keypoard display mode is
scramble mode.
11.Keyboard mode
Input the setting code.
10+#
Inputting of value (ex.: 0)
range:0(standard)/1:(scramble)
0+#
(Default:1(scramble))
12.Unlock work mode
Input the setting code.
11+#
Inputting of value (ex.: 0)
range:0~3
0+#
(Default:0)
- 0:Unlock via password or user
card(only release the first lock).
- 1:Unlock via password or user
card(swipe user card once time to
release the first lock; if swipe user
card twice in a second to release the
second lock).
- 2:Unlock via user card and
password(except the temporary
password).
- 3:Unlock via user card and
password(including the temporary
password).
Beep+, Beep
(on)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
-
When the “ cancel” key is pressed, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
-
When there isn’t any operation within 10s, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
Beep, Beep+
*
(off)
(off)(off)
LED1 LED2 LED3

-11-
Input the master code.
(Default: [ ] +[#])
14.Update(master / user
card / password / tone)
Input the setting code.Input the setting code.
13. Backup(master / user
card / password / tone)
12+#
1234+#
13+#
Inputting of code
1234+#
Inputting of code
-
When backup, you need to
Insert SD card into the SD card
slot.
.
-
When update, you need to
Insert SD card(the update file
is stored in SD card) into the
SD card slot.
15.Device address
Input the setting code.
14+#
Inputting of value (ex.: 0)
range:0~3
0+#
(Default:0 )
16.RLC control
(Default:0 )
-
Device address Settings:
0(device address:0),1(device
address:1),2(device address:2),
3(device address:3).
-
DT-RLC association control:
0:According to AKP address
auto-correlation;
1:Association of the first RLC;
2:Association of the second RLC;
3:Association of the third RLC;
4:Association of the fourth RLC.
Beep+, Beep
(on)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Input the setting code.
15+#
Inputting of value (ex.: 1)
range:0~4
1+#
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
-
When the “ cancel” key is pressed, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
-
When there isn’t any operation within 10s, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
Beep, Beep+
*
(off)
(off)(off)
LED1 LED2 LED3

-12-
Input the master code.
(Default: [ ]+[#] )
Inputting of code (ex.: 2011)
1~12 digits
Inputting of code (ex.: 2012)
1~12 digits
19.Set the code for
user group 1
20.Set the code for
user group 2
18.Temporary(single use
only) password for relay2
Input the setting code.Input the setting code.
17.Temporary(single use
only) password for relay1
18+# 19+# 21+# 60+#
2011+#
Inputting of value (ex.: 1006)
1~12 digits
1006+#
Inputting of code (ex.: 2016)
1~12 digits
2016+# 2012+#
Input the setting code.
(ex.:21)
Input the setting code.
(ex.:60)
20~59 60~99
- Once input the correct temporary password to release the door,
the system will clear the temporary password after 60 seconds
automatically. But the password is still valid within 60 seconds after
inputing the correct temporary password.
- The temporary1 is used to release the first lock,and the temporary
2 is used to release the second lock(the second lock need external
device to support).
- If the password exceeds 12 digits, the system will make the sound
of “beep,beep,beep,beep”,and the digitals you input before will be
cleared at the same time.
- The temporary code can not be set the same as the master code
and user code.
- The user code group1 is used to release the first lock,and the user code
group2 is used to release the second lock(the second lock need external
device to support).
- The user code group1 and user code code group2 can contain 40
group passwords
- If the password exceeds 12 digits, the system will make the sound of
“beep,beep,beep,beep”,and the digitals you input before will be cleared
at the same time.
- The user code can not be set the same as the master code and
temporary code.
Beep+, Beep
(on)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(on)
(off)(off)
LED1 LED2 LED3
-
When the “ cancel” key is pressed, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
-
When there isn’t any operation within 10s, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
Beep, Beep+
*
(off)
(off)(off)
LED1 LED2 LED3

-13-
Input the master code.
(Default: [ ]+[#] )
23.Delete user card 24.Format user card22.Add user card
Input the setting code.Input the setting code.
21.Register [Manage card]
100+# 101+# 102+# 103+#
Inputting of code
1234+#
Inputting of code
1234+#
Inputting of code
1234+#
Inputting of code
1234+#
Input the setting code. Input the setting code.
- Swipe the first card to ID card
window, it will be set to
MASTER
CARD ADD
card.
- Swipe the second card to ID card
window, it will be set to
MASTER
CARD DELETE
card.
-When registered new master
cards, the old master cards are
invalid automatically.
- Another way:
Swipe the
MASTER CARD ADD
card to ID card window in standby
mode, and then swipe user cards
one by one to be added.
- Another way:
Swipe the
MASTER CARD DELETE
card to ID card window in standby
mode, and then swipe user cards
one by one to be deleted.
Beep+, Beep
(on)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(off)
(on)(off)
LED1 LED2 LED3
Beep+
(off)
(on)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(off)
(flash)(off)
LED1 LED2 LED3
Beep+, Beep
(flash)(off)(off)
LED1 LED2 LED3
Beep+
(off)
(off)(off)
LED1 LED2 LED3
Swipe MASTER CARD ADD card
and MASTER CARD DELETE
card in the ID window.
Swipe new user card one by one
to be added in the ID window.
Swipe user card one by one to be
deleted in the ID window.
Beep+
(off)
(flash)(off)
LED1 LED2 LED3
Beep+
(off)
(on)(off)
LED1 LED2 LED3
Beep+
(off)
(flash)(off)
LED1 LED2 LED3
-
When the “ cancel” key is pressed, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
-
When there isn’t any operation within 10s, the indicator will show its standby color,
the buzzer beeps, and the system exits the setting mode.
Beep, Beep+
*
(off)
(off)(off)
LED1 LED2 LED3

-14-
6.Unlock Operations
When the registered user code has been input using the keypad (1~12 digits), the digitron will display “OP1”
or “OP2”, and the LED1 indicator lights up, and the system will synthesis sound of “Door is open”(If the Tone
Select item is set to 1), then the electric door strike is unlocked.(note that you should press "#" button(if "#"
button is set to conrm button) after input the unlock code)
When the registered user card has been shown to ID card window, the digitron will display “OP1”(if swipe user
card twice in a second in the ID card window, the digitron will display “OP2”), and the LED1 indicator lights up,
and the system will synthesis sound of “Door is open”(If the Tone Select item is set to 1), then the electric door
strike is unlocked.
•The time interval between 2 digitals' input must be less than approximately 10 seconds. otherwise the input
value will be cleared.
•If you make a mistake when inputting the user code,press the" cancel" button and input the user code again.
•The release function is forbidden and the input operation is disabled for 60 seconds if 10 times incorrect
access codes are continuously attempted. During this time,the buzzer will continuously sound about 8 times.
Unlock by user code
Unlock by user card
7.Specications
•Power Supply : DC 24V;
•Power Consumption: Standby 23mA; Working status 43mA;
•Unlocking time: 1~99s
•Lock Power supply: 12Vdc, 280mA(Internal Power);
•Number of relay circuits: 2(the second lock need external device to support)
•Mounting: Surface mounting
• Working temperature: -15ºC ~ +55ºC
•Dimension: 151(H)×95(W)×37(D)mm

•Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If
necessary, please use a little pure water or dilute soap water to clean the dust.
•The unit is weather resistant. However do not spray high pressure water on access control keypad directly.
Excessive moisture may cause problems with the unit.
•You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
•Pay attention to the high voltage inside the products, please refer service only to a trained and qualified
professional.
• The design and specications can be modied without notice to the user. Right to interpret and copyright of
this manual are reserved.
DT-ENG-AKP-V1 / 201701
Table of contents
Popular Keypad manuals by other brands

PulseWorx
PulseWorx KPLC7 Installation guide and owner's manual

Protection One
Protection One 6150RFPL2 Installation and setup guide

DMP Electronics
DMP Electronics XTL Series user guide

Aritech
Aritech ATS1135 Installation sheet

ET NICE
ET NICE E-Pad O2 Active Installation and setup instructions

AEI
AEI DK-9680 Series manual