manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Interlogix
  6. •
  7. Security Sensor
  8. •
  9. Interlogix Sentrol DV1201A User manual

Interlogix Sentrol DV1201A User manual

- 1 -
DV1201A & DV1221A
Seismic Detectors Installation Manual
Figure 2: Two ways to test the seismic detectors
1/2. 12 Vdc 7. Common (C)
3. LED indication 8/9. Tamper
4. Integrator level 10. Test control
5. Normaly Closed (NC) 11. Spare
6. Normaly Open (NO)
Test disabled (ex-factory setting)
Internal test of detector’s electronics =
Position jumper between 1 and 2 .
Function test of the detector and its physical contact
with the protected object = Position connector from
test transmitter DV1215A between 2 and 3.

Connecting terminal 10 to 0 V activates both tests.
1. Cover
2. Cover screw
3. Base plate
4. Mounting holes
5. Clamp
6. Area for mounting the
DV1215A test transmitter
7. Potentiometer for adjusting
the detector’s sensitivity
8. Connection block
9. Anti-tamper micro-switch
10. Mounting plate DV1202A
11. Fixing bolt
12. Expander bolt
13. Test transmitter DV1215A
Figure 3: General characteristics of the DV1201A / DV1221A
Using the mounting plate DV1202A as a template
A. Holes for DV1201A / DV1221A
B. Hole for expansion plug or recess mounting box
C. Template and mounting holes for test transmitter DV1215A
D. Holes for accessories.
Figure 4: Mounting the detector directly on a metal surface without using a mounting plate
Figure 1: Wiring diagram
Sentrol
24-04-'02
Manual DV1201A / DV1221A 14 999-
5620
Form: Letter (bookshape)
Formaat: Letter (boekvorm)
A4
G. Manders
110-01
White paper: 70gr/m² progresso; overprint black. If P.O.D.: use 80gr/m².
Wit papier: 70gr/m² progresso; opdruk zwart. Wanneer P.O.D.: gebruik 80gr/m². 1 A 24-04-'02 10423-10424
- 1 -
DV1201A & DV1221A
Seismic Detectors Installation Manual
Figure 2: Two ways to test the seismic detectors
1/2. 12 VDC 7. Common (C)
3. LED indication 8/9. Tamper
4. Integrator level 10. Test control
5. Normaly Closed (NC) 11. Spare
6. Normaly Open (NO)
!Test disabled (ex-factory setting)
"Internal test of detector’s electronics =
Position jumper between 1 and 2 .
#Function test of the detector and its physical contact
with the protected object = Position connector from
test transmitter DV1215A between 2 and 3.
$
Connecting terminal 10 to 0 V activates both tests.
1. Cover
2. Cover screw
3. Base plate
4. Mounting holes
5. Clamp
6. Area for mounting the
DV1215A test transmitter
7. Potentiometer for adjusting
the detector’s sensitivity
8. Connection block
9. Anti-tamper micro-switch
10. Mounting plate DV1202A
11. Fixing bolt
12. Expander bolt
13. Test transmitter DV1215A
Figure 3: General characteristics of the DV1201A / DV1221A
Using the mounting plate DV1202A as a template
A. Holes for DV1201A / DV1221A
B. Hole for expansion plug or recess mounting box
C. Template and mounting holes for test transmitter DV1215A
D. Holes for accessories.
Figure 4: Mounting the detector directly on a metal surface without using a mounting plate
Figure 1: Wiring diagram
Sentrol
- 2 -
Figure 5: Mounting on concrete
Always use a DV1202A mounting plate. The expansion plug must
penetrate at least 50 mm into the concrete. Please follow the steps
shownin Figure 6 ifyouareinstallingthetest transmitter DV1215A.
$
For the equipment to conform to CEI standard 79-2, the
DV1215A test transmitter must be installed.
Figure 6: Control and function test
Usingavoltmeter,checkthe background signal levelinthedetector
to prevent nuisance alarms. Set the sensitivity to Gmax during the
test.
DV1201A DV1221A Measure
0.7 V 0 V None
1.4 V 2 V Reduce range/remove source
$
Try to remove the source of ambient noise instead of
reducing the range.
Functional testing with hand tester DV1230 !and mechanical
tool ":
DV1201A DV1221A
Alarm in 30 sec. Alarm in 45 sec.
Alarm after 5 blows NA
Detection range (in foot): Technical specifications:
Input power: 9-15 VDC
2 V max. ripple pp
Current consumption: Nom. 8.6 mA
Alarm output: Form C solid state relay, max. series
resistance 35 Ohm
Alarm indication: LED-ind. output 3
Sensitivity: 5 steps of 6 dB each
Range: See Table “Detection range”
Sabotage protection: Temp. 183.2 °F
drill shield,
opening/pry-off contact,
Low voltage alarm: 7.5 V
Temperature limits: -4 °F to + 131 °F
Dimensions: 3.93 x 3.15 x 1.30 inches
Colour: Grey, RAL 7035
Weight: 0.86 lb
Concrete 13.12 45.93 45.93
Steel 1/Gmax 26.25 45.93 45.93
Brick 9.84 26.25 26.25
Concrete 9.84 29.53 29.53
Steel 2/Gref 13.12 29.53 29.53
Brick 3.28 19.69 19.69
Concrete 6.56 19.69 19.69
Steel 3/Gmin 6.56 19.69 19.69
Brick - 13.12 13.12
Concrete 3.28 16.40 16.40
Steel 4 3.28 16.40 16.40
Brick - 9.84 9.84
Concrete - 13.12 13.12
Steel 5 - 13.12 13.12
Brick - 6.56 6.56
Sensitivity
setting
Material Thermal
lance Diamond
disk Drilling
- 3 -
Figure 7: Wiring the DV1201A/DV1221A into Most Security Systems
Figure 8: Connecting the DV1201A to a Four-wire Circuit
Type Control in an UL Complete Mercantile Safe System Figure 9: Connecting the DV1201A to a Two-wire Balanced
Loop Type Control in an UL Complete Mercantile Safe
System
Figure 10: Wire Diagram DV1208A
- 4 -©Sentrol is an Interlogix company. 2002. All rights reserved. 5620-1A
Figure 11

This manual suits for next models

1

Other Interlogix Security Sensor manuals

Interlogix VE1012 Series Assembly instructions

Interlogix

Interlogix VE1012 Series Assembly instructions

Interlogix DC428 Specification sheet

Interlogix

Interlogix DC428 Specification sheet

Interlogix DDI602AM Assembly instructions

Interlogix

Interlogix DDI602AM Assembly instructions

Interlogix R5812NT User manual

Interlogix

Interlogix R5812NT User manual

Interlogix EV1116-D Series Assembly instructions

Interlogix

Interlogix EV1116-D Series Assembly instructions

Interlogix TVK-600 Instruction sheet

Interlogix

Interlogix TVK-600 Instruction sheet

Interlogix DD669 Assembly instructions

Interlogix

Interlogix DD669 Assembly instructions

Interlogix AP633A User manual

Interlogix

Interlogix AP633A User manual

Interlogix EV1012 Series Assembly instructions

Interlogix

Interlogix EV1012 Series Assembly instructions

Interlogix xGen Lite Installation guide

Interlogix

Interlogix xGen Lite Installation guide

Interlogix GS960AM User manual

Interlogix

Interlogix GS960AM User manual

Interlogix DD1012AM-D Assembly instructions

Interlogix

Interlogix DD1012AM-D Assembly instructions

Interlogix Kalatel 600-9400-IMAG User manual

Interlogix

Interlogix Kalatel 600-9400-IMAG User manual

Interlogix DDI602AM Assembly instructions

Interlogix

Interlogix DDI602AM Assembly instructions

Interlogix DD490 Series Assembly instructions

Interlogix

Interlogix DD490 Series Assembly instructions

Interlogix TX-4200-01-1 Assembly instructions

Interlogix

Interlogix TX-4200-01-1 Assembly instructions

Interlogix RF-EV1012-K4 User manual

Interlogix

Interlogix RF-EV1012-K4 User manual

Interlogix VE1016 Series Assembly instructions

Interlogix

Interlogix VE1016 Series Assembly instructions

Interlogix RF-EV1012PI-K4 User manual

Interlogix

Interlogix RF-EV1012PI-K4 User manual

Interlogix DDV1016AM Assembly instructions

Interlogix

Interlogix DDV1016AM Assembly instructions

Interlogix RF711I4 Assembly instructions

Interlogix

Interlogix RF711I4 Assembly instructions

Interlogix Firefighter SLX-AD-T3 Guide

Interlogix

Interlogix Firefighter SLX-AD-T3 Guide

Interlogix DD300-P Series Assembly instructions

Interlogix

Interlogix DD300-P Series Assembly instructions

Interlogix TX-2810-03-4 Assembly instructions

Interlogix

Interlogix TX-2810-03-4 Assembly instructions

Popular Security Sensor manuals by other brands

Radiodetection spx RD8200 Operation manual

Radiodetection

Radiodetection spx RD8200 Operation manual

CAME 001SDTEWL manual

CAME

CAME 001SDTEWL manual

Honeywell 14506873-001 installation instructions

Honeywell

Honeywell 14506873-001 installation instructions

MAG BRD02 quick guide

MAG

MAG BRD02 quick guide

AMC IF800T installation manual

AMC

AMC IF800T installation manual

Aritech EV1116 Series Installation sheet

Aritech

Aritech EV1116 Series Installation sheet

Nice LP21 User, installation and safety instructions

Nice

Nice LP21 User, installation and safety instructions

B.E.G. LUXOMAT PD4-S-K manual

B.E.G.

B.E.G. LUXOMAT PD4-S-K manual

Lince 1926BOBBY-T-AM/U Installation, operation and maintenance manual

Lince

Lince 1926BOBBY-T-AM/U Installation, operation and maintenance manual

SUNLIT TECH OSD-40DP installation guide

SUNLIT TECH

SUNLIT TECH OSD-40DP installation guide

PCB Piezotronics 482C24-SU Installation and operating manual

PCB Piezotronics

PCB Piezotronics 482C24-SU Installation and operating manual

WATERGUARD Solo installation guide

WATERGUARD

WATERGUARD Solo installation guide

UTC Fire and Security EDWARDS 250-CO SafeAir Installation sheet

UTC Fire and Security

UTC Fire and Security EDWARDS 250-CO SafeAir Installation sheet

Glasdon GLENWOOD 170 POST Installation and maintenance instructions

Glasdon

Glasdon GLENWOOD 170 POST Installation and maintenance instructions

ELTEX UPG-Stitch instructions

ELTEX

ELTEX UPG-Stitch instructions

Honeywell ADEMCO 5808EU installation instructions

Honeywell

Honeywell ADEMCO 5808EU installation instructions

GJD D-TECT 1 manual

GJD

GJD D-TECT 1 manual

HP 423A Operating note

HP

HP 423A Operating note

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.