Intertec Data Systems MPR-A Series User manual

I-00599 Rev A
MPR-A SERIES
RLM-30TL-HWIGA
Instruction Sheet
Thank you for purchasing the RLM-30TL-HWIGA Module. Please read these instructions thoroughly
before installing this product.
THANK YOU
CONTROLLED
30 AMP MODULE
120V - 30A - 60Hz
RLM-30TL-HWIGA
Status Control
Activation
Normally
Open
Normally
Closed
ON
OFF
AUTO
INPUTOUTPUT
Conforms to UL Std
5 & 5A
Certified to CSA Std
C22.2 No. 62 & C22.2 No. 62.1

DANGER HAZARDOUS VOLTAGE/DANGER HAUTE
TENSION
The lightning flash with the arrowhead symbol, within an
equilateral triangle is intended to alert the user to the
presence of uninsulated dangerous voltage within the
product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
L'éclair avec le symbole de flèche dans un triangle
équilatéral est destiné à alerter l'utilisateur de la présence
d'une tension dangereuse non isolée dans l'enceinte du
produit qui peut être d'une ampleur suffisante pour constituer
un risque de choc électrique pour les personnes.
CAUTION/ATTENTION
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the appliance.
Le point d'exclamation dans un triangle équilatéral est
destiné à alerter l'utilisateur de la présence d'importants
instructions d’opération et de maintenance (entretien) dans la
documentation accompagnant l'appareil.
READ AND SAVE THESE INSTRUCTIONS!
CONSERVER CES INSTRUCTIONS!
• To reduce risk of shock , disconnect the device from the power source before
servicing any connected equipment
Pour réduire les risques d'électrocution, débranchez l'appareil de la source
d'alimentation avant l'entretien de tout équipement connecté
• Do not overload this device. Ensure the total load to this device does not
exceed that which is listed in the specifications section of this manual
Ne pas surcharger cette appareil. S'assurer que la charge totale à cet
appareil ne dépasse pas celle qui est répertoriée dans la section des
spécifictions de ce manuel
• To be used indoors in a dry location only
Pour être utilisé en intérieur dans un endroit sec seulement
• Do not operate with a damaged cord or plug
Ne pas faire fonctionner avec un cordon ou une prise endommagée
• Clean only with dry cloth
Nettoyer avec un chiffon sec seulement
IMPORTANT SAFETY INSTRUCTIONS
The product meets the requirements of the following standards:
• UL Standard 5 & 5A, CSA-C22.2 No. 62 & C22.2 No. 62.1
Conforms to UL Stds.
5 & 5A
Certified to CSA Stds.
C22.2 No. 62 & C22.2 No. 62.1
Conforms to UL Stds.
5 & 5A
Certified to CSA Stds.
C22.2 No. 62 & C22.2 No. 62.1
Conforms to UL Stds.
5 & 5A
Certified to CSA Stds.
C22.2 No. 62 & C22.2 No. 62.1
CONTROLLER
TO NEXT RLM
1) Connect the status terminal block of the first module to the control terminal block of the second
module. Connect additional modules using the status terminal block of the previous module.
DO NOT connect more then one RLM module to a dry contact. This may cause undesired operation.
CONTROLING MULTIPLE RLMs VIA A SINGLE CONTACT CLOSURE

Page 3
NOTE: 10 AWG copper wire MUST be used. Wire can be solid or stranded.
1) Insert wiring into spring loaded opening according to diagram. (FIGURE A)
NOTE: Once wiring is inserted into the opening, the wire securing spring clip will clench the wire
automatically. To remove wire, insert a small flathead screwdriver into the rectangular opening
above the wire.
SAFETY
GROUND
LINE
NEUTRAL
FIGURE A
WIRING THE MODULE
CONTROLLED
30 AMP MODULE
120V - 30A - 60Hz
RLM-30TL-HWIGA
Status Control
Activation
Normally
Open
Normally
Closed
ON
OFF
AUTO
INPUTOUTPUT
Conforms to UL Std
5 & 5A
Certified to CSA Std
C22.2 No. 62 & C22.2 No. 62.1
CONNECTIONS, CONTROLS AND INDICATORS
1 2
3
4
1
2
3
4
5
6
7
5
67
CONTACT CONTROL SELECTOR SWITCH: Allows the customer to choose to control the module
using either a 'normally open' or 'normally closed' dry contact. Factory default setting is
'normally open'.
GREEN STATUS LED: This will illuminate whenever the power and status relays are energized.
TWIST-LOCK RECEPTACLE: NEMA L5-30-R, 30A, 125V.
CONTROL SWITCH: Three position slide switch.
POSITION #1: AUTO - The receptacle will be energized when contact closure is supplied.
POSITION #2: OFF - The receptacle will not respond to any contact closure. The module cannot be
energized in the OFF position.
POSITION #3: ON - The receptacle will be energized and contact closure will have no effect.
YELLOW STATUS LED: This will illuminate whenever the control switch is in the AUTO position.
This is an indication that the internal power supply is functioning and that the module will respond to
a contact closure.
CONTROL TERMINALS: These terminals energize the receptacle with a dry contact closure.
STATUS TERMINALS: Dry contact closed when receptacle is energized. Rated capacity is .5A.

Page 4
1) Insert module straight down into the raceway (FIGURE B).
2) Slide the module into raceway (FIGURE C).
3) Screw the module to the raceway (FIGURE D).
USE A HAND-HELD SCREWDRIVER AND DO NOT OVERTIGHTEN!
(FIGURE D)
(FIGURE B) (FIGURE C)
WARRANTY
Middle Atlantic Products (the "Company") warrants the RLM-30TL-HWIGA to be free from defects in material or workmanship under normal use and conditions for a period of three (3) years from the date of
shipment by the company.
The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of and
refund of the price paid for, or (b) repair or replacement at the Company's factory of the products purchased, or any part or parts thereof, which the Company has determined to be defective after inspection
thereof at the Company's factory.
This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by parties other than the Company, or any modification or alteration of the products. In addition, this warranty
does not cover damage due to improper handling, assembly, installation or maintenance.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE
OF THE PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER
PARTY) HEREUNDER, IF ANY, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS PAID TO THE COMPANY.
Corporate Headquarters Middle Atlantic Canada Factory Distribution
Corporate Voice 973-839-1011 - Fax 973-839-1976 Voice 613-836-2501 - Fax 613-836-2690 USA: NJ - CA - IL Canada: ON - BC
International Voice +1 973-839-8821 - Fax +1 973-839-4982 middleatlantic.ca - [email protected]
At Middle Atlantic Products we are always listening. Your comments are welcome. Middle Atlantic Products is an ISO 9001 and ISO 14001 Registered Company.
INSTALLATION OF MODULE TO RACEWAY
This manual suits for next models
1
Popular Control Unit manuals by other brands

Miele
Miele XKM 3200 WL PLT operating instructions

handtmann
handtmann 33501 manual

ABB
ABB COM600 series user manual

Spirax Sarco
Spirax Sarco M80i ISO Installation and maintenance instructions

Festo
Festo CPX-AP-A-12DI4DO-M12-5P operating instructions

Texas Instruments
Texas Instruments HSS-MOTHERBOARDEVM user guide