Invacare Envoy Jr. IRC1001 User manual

OWNER'S MANUALOWNER'S MANUAL
OWNER'S MANUALOWNER'S MANUAL
OWNER'S MANUAL
GUIDE DE LUTILISATEURGUIDE DE LUTILISATEUR
GUIDE DE LUTILISATEURGUIDE DE LUTILISATEUR
GUIDE DE LUTILISATEUR
MANUAL DE INSTRUCCIONESMANUAL DE INSTRUCCIONES
MANUAL DE INSTRUCCIONESMANUAL DE INSTRUCCIONES
MANUAL DE INSTRUCCIONES
AEROSOL COMPRESSOR
MODEL IRC1001
COMPRESSEUR AÉROSOL
MODÈLE IRC1001
COMPRESOR PARA AEROSOL
MODELO IRC1001
Envoy
Jr.
All manuals and user guides at all-guides.com
all-guides.com

2
SPECIAL NOTES
DANGER/WARNING/CAUTION notices as used in this
manual apply to hazards or unsa e practices which could
result in personal injury or property damage.
NOTICE
THE INFORMATION CONTAINED IN THIS DOCU-
MENT IS SUBJECT TO CHANGE WITHOUT NOTICE.
THIS AEROSOL COMPRESSOR IS INTENDED FOR
HOUSEHOLD USE.
WARNING
DO NOT INSTALL, MAINTAIN OR OPERATE
THIS EQUIPMENT WITHOUT FIRST
READING AND UNDERSTANDING THIS
MANUAL. IF YOU ARE UNABLE TO
UNDERSTAND THE DANGERS/WARNINGS/
CAUTIONS AND INSTRUCTIONS, CON-
TACT YOUR HOME HEALTHCARE DEALER
BEFORE ATTEMPTING TO USE THIS EQUIP-
MENT - OTHERWISE INJURY OR DAMAGE
MAY RESULT.
SAVE THESE INSTRUCTIONS
SPECIAL NOTES
All manuals and user guides at all-guides.com

3
TABLE OF CONTENTS
SPECIAL NOTES................................................................... 2
IMPORTANT SAFEGUARDS .............................................. 4
SPECIFICATIONS AND
SUPPLEMENTAL INFORMATION .................................... 6
FEATURES ............................................................................. 8
HANDLING PROCEDURES ................................................ 9
Shipping and Transportation Instructions ......................................... 9
Unpacking .................................................................................................. 9
Inspection .................................................................................................. 9
Storage ....................................................................................................... 9
OPERATION .......................................................................... 9
MAINTENANCE.................................................................. 12
Cleaning the Outer Case .................................................................... 12
Cleaning the Nebulizer ........................................................................12
Cleaning or Replacing the oam Intake ilter ................................13
ACCESSORIES AND LIMITED WARRANTY ................. 13
GUIDE DE LUTILISATEUR .............................................. 16
MANUAL DE INSTRUCCIONES ...................................... 30
TABLE OF CONTENTS
All manuals and user guides at all-guides.com

4
IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USING
Caution: Federal law restricts this device to sale by or on
order o a physician, or any other practitioner licensed by
the law o the State in which he practices to use or order
the use o this device.
When using electrical products, especially when children
are present, basic sa ety precautions should always be
ollowed, including the ollowing:
DANGER
TO REDUCE THE RISK OF ELECTROCUTION
ALWAYS unplug this product IMMEDIATELY a ter using.
DO NOT use while bathing.
DO NOT place or store product where it can all or be
pulled into a tub or sink.
DO NOT reach or product that has allen into water.
UNPLUG IMMEDIATELY.
DO NOT place or drop into water or other liquid.
WARNING
TO REDUCE THE RISK OF BURNS, ELECTROCUTION,
FIRE OR INJURY TO PERSONS
This product should NEVER be le t unattended when
plugged in.
Close supervision is necessary when this product is used
by, on, or near CHILDREN AND PHYSICALLY
CHALLENGED INDIVIDUALS.
Use this product only or its intended use as described in
this manual. Use this product only under physicians
direction. DO NOT use attachments not recommended
by the manu acturer.
IMPORTANT SAFEGUARDS
All manuals and user guides at all-guides.com

5
WARNING
NEVER operate this product with a damaged cord or plug,
i it is not working properly, i it has been dropped or
damaged, or dropped into water; call Quali ied Service
Personnel or examination and repair.Keep the cord away
rom HEATED or HOT sur aces.
NEVER drop or insert any object into any opening.
NEVER use while sleeping or drowsy.
NEVER block the air openings o the product or place it
on a so t sur ace, such as a bed or couch, where the air
openings may be blocked. Keep the air openings ree rom
lint, hair and the like. Blocked openings may cause the
unit to shut down. Contact dealer immediately.
DO NOT use outdoors or operate where aerosol (spray)
products are being used or where oxygen is being adminis-
tered in a closed environment such as an oxygen tent.
This unit is oil-less. DO NOT lubricate.
CAUTION
Risk o electric shock. Do not disassemble. Re er servicing
to quali ied service personnel.
IMPORTANT SAFEGUARDS
All manuals and user guides at all-guides.com

6
SPECIFICATIONS AND
SUPPLEMENTAL INFORMATION
STANDARD SPECIFICATIONS
Electrical Requirements:
Running Current:
Sound Level:
Ambient Temperature Range:
Power Wattage:
Thermal Protector:
oam Intake ilter:
Safety Systems:
Width:
Height:
Depth:
Weight:
Shipping Weight:
Regulatory Listing:
115 VAC, 60Hz, Single Phase
1.8 A @ 10 psig @ 115 volts (approx.
55 dBA
50°F - 104°F (10°C - 40°C
80 watts @ 10 psig
UL 547 Class B
Open cell 100 ppi, polyurethane foam.
High temperature compressor shutdown.
4.1-inches
7.0-inches
7.0-inches
3.5 Ibs.
4.5 lbs.
In compliance with UL 1431 Personal
Hygiene and Healthcare Appliances and
CSA 22.2 No. 68-92 Motor Operated
Appliances.
ELECTRICAL
This appliance has a polarized plug (one blade is wider than the other).
As a safety feature, this plug will fit in a polarized outlet only one way. If
the plug does not fit fully in the outlet, reverse the plug. If it still does
not fit, contact a qualified electrician. Do not attempt to defeat this
safety feature.
SPECIFICATIONS
All manuals and user guides at all-guides.com
all-guides.com

7
Compressor:
If the unit shuts down frequently, you may have a low voltage situation.
Low voltage can also be suspected when:
1. The motor does not get up to full power or speed.
2. Home fuses or circuit breakers activate when starting compressor.
3. Lights dim or remain dim when compressor is started.
4. Other motor operated appliances fail to operate properly or too
many motor operated appliances are on same circuit.
The motor of this compressor has a thermal overload protector. If the
motor should overheat, the overload protector will shut off the motor.
If the unit shuts down and cannot be restarted, the motor must be
replaced. Call your dealer immediately.
Extension Cords:
Make certain extension cord is in good condition. Make certain extension
cord wire is NOT LESS than 18 gauge for 25 feet, 16 gauge for 50 feet and
14 gauge for 100 feet.
MAINTENANCE
Only authorized or factory-trained personnel should perform preventative
maintenance.
SPECIFICATIONS
All manuals and user guides at all-guides.com

8
FEATURES
FIGURE 1 - FEATURES
Rear Power Switch
Detents for Cord Wrap
Reusable
Foam Intake
Filter
Compressor Air Outlet
for Nebuli er Tubing
Easy Grip Handle
Nebuli er Air
Tubing
Nebuli er
Case
FEATURES
Nebuli er
Mouthpiece
All manuals and user guides at all-guides.com

9
HANDLING PROCEDURES
SHIPPING AND TRANSPORTATION INSTRUCTIONS
The shipping container has been designed to assure protection of this
device.
If this device is to be reshipped by common carrier, it should be packed
in the same carton. Extra cartons are available from Invacare.
UNPACKING
1. Check for any obvious damage to the carton or its contents. If
damage is evident, do NOT use. Notify Carrier/Invacare or your
local Invacare Dealer.
2. Remove all the loose packing from the carton.
3. Carefully remove all the components from the carton.
NOTE: Retain carton and packing materials for use in shipping or storing the
unit until use is required.
INSPECTION
1. Examine exterior for nicks, dents, scratches or other damage.
Inspect all components.
STORAGE
1. Store the repackaged device in a dry area.
2. DO NOT place other objects on top of the repackaged device.
Your disposable nebulizer package includes a nebulizer mouthpiece,
nebulizer, and air tubing. These items are sold as a package only.
NOTE: Before initial operation, nebulizer should be cleaned. ollow the recommended
Cleaning Instructions in this Owners Manual.
OPERATION
ANDLING PROCEDURES/ OPERATION
All manuals and user guides at all-guides.com

10
WARNING
DO NOT run unit without ilter.
Avoid operating this product in a dusty environment
which could cause premature compressor wear.
SETUP
1. Place the device on a table so that the controls can be reached
when seated.
2. Secure one end of the nebulizer tubing to the compressor air
outlet (FIGURE 1).
3. Connect the other end to the nebulizer.
WARNING
In the case o high humidity, condensation may orm
inside the internal tubing. Run the unit or two (2) minutes
be ore connecting the nebulizer to the tubing.
OPERATION
FIGURE 1 - LOCATION OF COMPRESSOR AIR OUTLET
Rear Power Switch Compressor Air Outlet
for connecting Nebuli er
Air Tubing
All manuals and user guides at all-guides.com

11
WARNING
Be ore plugging in the line cord, make sure that the power
switch is in the OFF (O) position.
5. Unwrap the line cord.
6. Plug into a 115V/60Hz wall outlet.
7. Insert the nebulizer mouthpiece into the top of the nebulizer.
NOTE: Before attempting to start a cold unit, let the unit reach room temperature in
a heated area.
8. Press the power switch ON ( I ) to start the compressor.
9. Place mouthpiece between your teeth and close your mouth
(FIGURE 3).
10. As aerosol begins to flow, inhale deeply, slowly, and hold breath for
10 seconds. Then exhale slowly through the mouthpiece.
NOTE: Before storing supplies between treatments, clean and dry nebulizer.
(Refer to Maintenance Section in this manual). Tighten caps on medication jars.
NOTE: In the event a substantial increase in back pressure is achieved, i.e.
kinked tubing, an audible "pop" or air leak may be heard. A relief valve has
been included to reduce possible damage to the compressor; which closes once
the back pressure has decreased.
FIGURE 3 - USING
T E NEBULIZER
FIGURE 2 - ADDING
LIQUID MEDICATION
TO T E NEBULIZER
4. Add liquid medication to the nebulizer according to your
physicians prescription (FIGURE 2).
OPERATION
All manuals and user guides at all-guides.com
all-guides.com

12
MAINTENANCE
WARNING
Electrical shock hazard. DO NOT remove outer case o
this unit. All disassembly and maintenance o this unit
MUST BE done by a quali ied Invacare Dealer.
CLEANING THE OUTER CASE
WARNING
UNPLUG unit be ore cleaning. DO NOT submerge in
water to clean. Clean outer case with damp cloth.
CLEANING THE NEBULIZER
NOTE: With proper maintenance your nebulizer should last 30 days. Since the nebulizer
is disposable, it is recommended that an extra nebulizer be kept at all times.
NOTE: Clean the Nebulizer after every use and at least once a day.
NOTE: Your physician and/or a Invacare Dealer may specify certain cleaning
procedures. If so, follow their recommendations. If not, clean according to the
following instructions:
1. Remove the nebulizer and mouthpiece from the tubing.
2. Disassemble nebulizer chamber by turning counterclockwise and
separating.
3. Fill two (2) plastic containers or bowls:
A. Washing: Hot water/detergent solution.
B. Soaking: Hot water/vinegar solution (one [1] part vinegar to
three [3] parts water).
4. Thoroughly clean the nebulizer and mouthpiece in hot water/
detergent solution.
5. Remove from the water/detergent solution and rinse with clear hot
tap water.
6. Soak in hot water/vinegar solution for 30 minutes.
7. Rinse with hot tap water again and air dry thoroughly.
MAINTENANCE
All manuals and user guides at all-guides.com

13
ACCESSORIES
NOTE: The nebulizer and accessories are not manufactured by Invacare. Invacare
has maintained the integrity of the nebulizer manufacturer's original sealed
packaging and labeling.
Intake Filter / Filter Cover
Owner's Manual
MS2100 Disposable Nebulizer (5 ml Capacity , w/Mouthpiece, T-Piece, and 7 ft. tubing.
MS2200 Disposable Sidestream® Nebulizer (10 ml Capacity , w/Mouthpiece
and 7 ft. Tubing.
MS2400 Durable Sidestream® Nebulizer (10 ml Capacity , w/Mouthpiece and
7 ft. Tubing. One (1 Year Limited Warranty.
IRC1198 TruZone® PFM Peak Flow Meter
NOTE: See Invacare Dealer for additional Nebulizers.
NOTE: If using medical disinfectant cleaners, follow manufacturers instructions carefully.
8. Keep the outer surface of the tubing dust-free by wiping regularly.
NOTE: The nebulizer air tubing does not have to be washed internally because
only filtered air passes through the tubing.
CLEANING OR REPLACING THE FOAM INTAKE
FILTER
NOTE: Clean the filter once a month or sooner if filter discolors.
1. Unplug unit.
2. Remove filter cover to gain access to filter.
3. Remove filter and clean with soap and water. Let dry thoroughly
before use.
4. Replace filter if it becomes clogged, torn or has a worn appearance.
NOTE: Regular filter cleaning/replacing is necessary to help ensure proper
compressor performance.
WARNING
DO NOT run unit without ilter.
MAINTENANCE/ACCESSORIES
All manuals and user guides at all-guides.com

14
PLEASE NOTE: THE WARRANTY BELOW HAS BEEN
DRA TED TO COMPLY WITH EDERAL LAW APPLICABLE
TO PRODUCTS MANU ACTURED A TER JULY 4,1975.
This warranty is extended only to the original purchaser of our
products.
This warranty gives you specific legal rights and you may also have
other legal rights which vary from state to state.
Invacare warrants the compressor of the Invacare Aerosol Com-
pressor to be free from defects in materials and workmanship for a
period of three (3) years from date of purchase. The nebulizer
chamber, nebulizer air tubing, and any other accessories are
excluded in this warranty. If within such warranty period any such
product shall be proven to Invacares satisfaction to be defective,
such product shall be repaired or replaced, at Invacares option.
This warranty does not include normal wear and tear or shipping
charges incurred in replacement part installation or repair of such
product. Invacares sole obligation and your exclusive remedy under
this warranty shall be limited to such repair or replacement.
or warranty service, please contact Invacares Service Depart-
ment during normal working hours at the Toll ree Number listed.
Upon receiving notice of an alleged defect in a product, Invacare
will issue a serialized return authorization. It shall then be the
responsibility of the purchaser to return, at purchasers cost, to
either Invacares plant or service center as specified by Invacare in
advance. Defective component part(s) must be returned for war-
ranty inspection using the serial number as identification within
thirty (30) days of return authorization date. DO NOT return
products to our factory without prior consent. C.O.D shipments will
be refused - please prepay shipping charges.
Limitations and Exclusions: The foregoing warranty shall not apply
to products subjected to negligence, accident, improper operation,
maintenance or storage, commercial or institutional use, products
modified without Invacares express written consent (including, but
not limited to, modification through the use of unauthorized parts
or attachments) or to products damaged by reason of repairs made
to any component without the specific consent of Invacare, or to a
product damaged by circumstances beyond Invacares control.
LIMITED WARRANTY
WARRANTY
All manuals and user guides at all-guides.com

15
The foregoing warranty is exclusive and In lieu of all other express
warranties. Implied warranties, if any, including the implied warran-
ties of merchantability and fitness for a particular purpose, shall not
extend beyond the duration of the expressed warranty provided
herein and the remedy for violations of any implied warranty shall
be limited to repair or replacement of the defective product
pursuant to the terms contained herein. Invacare shall not be liable
for any consequential or incidental damages whatsoever.
Some states do not allow the exclusion or limitation of incidental or
consequential damage, or limitation on how long an implied war-
ranty lasts, so the above exclusion and limitation may not apply to
you.
THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH
STATE/PROVINCIAL LAWS AND REQUIREMENTS.
WARRANTY
All manuals and user guides at all-guides.com

16
Les notes DANGER/AVERTISSEMENT/ATTENTION
utilisées dans ce manuel sappliquent aux pratiques non
sécuritaires pouvant causer des blessures ou des
dommages à la propriété.
NOTE
LINFORMATION CONTENUE DANS CE DOCUMENT
PEUT ÊTRE MODIFIÉE SANS PRÉAVIS.
CE COMPRESSEUR AÉROSOL EST PRÉVU POUR UN
USAGE DOMESTIQUE.
AVERTISSEMENT
NE PAS ins aller, en re enir ou u iliser ce
équipemen sans d'abord avoir lu e compris
ce manuel. Si vous ne comprenez pas les
no es DANGER/AVERTISSEMENT/ATTEN-
TION e les INSTRUCTIONS, veuillez
con ac er vo re fournisseur en soins à domi-
cile avan du iliser ce équipemen , sans quoi
des blessures ou dommages peuven survenir.
NOTES IMPORTANTES
CONSERVER CES INSTRUCTIONS
NOTES IMPORTANTES
Guide De LUtilisateur
All manuals and user guides at all-guides.com
all-guides.com

17
NOTES IMPORTANTES ...................................................... 16
RÈGLES DE SÉCURITÉ ......................................................... 18
SPÉCIFICATIONS ET INFORMATIONS
SUPPLÉMENTAIRES ............................................................. 20
CARACTÉRISTIQUES ........................................................... 22
PROCÉDURES DE MANIPULATION ................................. 23
Instructions Pour L'Expédition et le Transport................................ 23
Déballage .................................................................................................... 23
Inspection ................................................................................................... 23
Entreposage ............................................................................................... 23
OPÉRATION ........................................................................... 23
ENTRETIEN ............................................................................ 26
Nettoyer le Boîtier Extérieur ............................................................... 26
Nettoyer le Nébuliseur .......................................................................... 26
Nettoyer ou Remplacer le iltre D'Entrée en Mousse .................. 27
ACCESSOIRES ET GARANTIE LIMITÉE ........................... 28
MANUAL DE INSTRUCCIONES ......................................... 30
TABLE DES MATIÈRES
TABLE DES MATIÈRES
All manuals and user guides at all-guides.com

18
RÈGLES DE SÉCURITÉ
LIRE TOUTES LES INSTRUCTIONS
AVANT UTILISATION
«Attention: Suivant la loi édérale,cet appareil doit être
vendu par un médecin ou sur prescription de ce dernier,
ou par tout autre praticien reconnu par l'état où il pra-
tique, utilise ou prescrit cet appareil.»
Lors de lutilisation dappareils électriques, surtout en
présence d'en ants, toujours respecter les règles de
sécurité de base, incluant les suivantes:
DANGER
POUR RÉDUIRE LES RISQUES DÉLECTROCUTION
TOUJOURS débrancher l'appareil IMMÉDIATEMENT
après usage.
NE PAS utiliser en se baignant.
NE PAS entreposer ou placer à un endroit où il pourrait
tomber ou être tiré dans la baignoire ou dans le lavabo.
NE PAS reprendre l'appareil s'il est tombé dans leau.
DÉBRANCHER IMMÉDIATEMENT.
NE PAS placer ou laisser tomber dans leau ou dans un
autre liquide.
AVERTISSEMENT
POUR RÉDUIRE LES RISQUES DE BRÛLURES, D'ELECTRO-
CUTION, D'INCENDIE OU BLESSURES CORPORELLES
Ce produit ne doit JAMAIS être laissé sans surveillance
lorsque branché.
Une supervision étroite est nécessaire lorsque le produit est
utilisé par, pour ou près DENFANTS ET DE PERSONNES
HANDICAPÉES PHYSIQUEMENT.
N'utiliser ce produit que pour lusage prescrit dans ce
manuel. N'utiliser ce produit que sur recommandation dun
médecin. NE PAS utiliser daccessoires non recommandés
par le manu acturier.
RÈGLES DE SÉCURITÉ
All manuals and user guides at all-guides.com

19
AVERTISSEMENT
NE JAMAIS utiliser cet appareil si le il électrique ou la
iche sont endommagés, si lunité ne onctionne pas
adéquatement, sil est tombé sur le sol ou dans leau, ou
sil est endommagé; contacter un technicien de service
quali ié pour véri ication et réparation.
Éloigner le il électrique de toutes sur aces CHAUDES ou
CHAUFFANTES.
NE JAMAIS insérer ou laisser tomber dobjets dans les
ori ices.
NE JAMAIS utiliser lappareil en dormant ou lorsque
somnolant.
NE JAMAIS obstruer les ouvertures daération du produit
et ne jamais le placer sur une sur ace moelleuse,telle
quun lit ou un auteuil, où les ouvertures pourraient être
obstruées. Garder les ouvertures propres, libres de
cheveux, mousse, etc. Des ouvertures obstruées peuvent
arrêter le onctionnement de lappareil. Contacter le
ournisseur immédiatement.
NE PAS se servir de lunité à lextérieur, dans un endroit
où des produits aérosol sont utilisés ou de loxygène
administré, ou encore dans un environnement ermé tel
quune tente à oxygène.
Cet appareil ne contient pas dhuile. NE PAS lubri ier.
ATTENTION
Risques de décharges électriques. Ne pas démonter.
Con ier l'entretien à un technicien quali ié.
RÈGLES DE SÉCURITÉ
All manuals and user guides at all-guides.com

20
SPÉCI ICATIONS STANDARD
Exigences électriques:
Courant de fonctionnement:
Niveau sonore:
Écart de température ambiante:
Wattage:
Protecteur thermique:
iltre dentrée mousse:
Système de sécurité:
Largeur:
Hauteur:
Profondeur:
Poids:
Poids à lexpédition:
Réglementation:
115 V CA, 60 Hz, phase simple
1.8 A @ 10 lb/po² @ 115 volts (approx.
55dB
50°F - 104°F (10° - 40°C
80 watts @ 10 lb/po²
UL547, Classe B
Alvéoles ouvertes 100 ppi, mousse
polyuréthanne.
Coupe circuit à haute température.
11 pouces
4.4 pouces
8.5 pouces
5 livres
6 livres
Conformément aux règlements UL1431,
appareils pour hygiène personnelle et
soins de santé, et CSA 22.2, équipement
électromédical.
ÉLECTRICITÉ
Cet appareil a une fiche polarisée (les tiges ne sont pas de la même
grosseur). À titre de mesure de sécurité, cette fiche sinsèrera dans une
prise polarisée dune seule façon. Si la fiche ne sinsère pas
complètement dans la prise, inverser la prise. Si la fiche ne sinsère
toujours pas, contacter un électricien qualifié. Ne pas tenter de
contourner cette mesure de sécurité.
SPÉCIFICATIONS ET INFORMA
TIONS SUPPLÉMENTAIRES
SPÉCIFICATIONS
All manuals and user guides at all-guides.com
Other manuals for Envoy Jr. IRC1001
2
Table of contents
Languages:
Other Invacare Compressor manuals
Popular Compressor manuals by other brands

Mannesmann
Mannesmann 01771 Original manual

ULTIMATE SPEED
ULTIMATE SPEED USKT 60 A2 Operation and safety notes