SYSTEM OVERVIEW: IV14-ZERO VENTILATION UNIT
10 iV14-Zero ventilation unit | Installation instructions
1.1 Function
The iV14-Zero ventilation system is used to provide ventilation for living rooms and bedrooms.
The combination of inVENTron, thermal accumulator and sound insulation lining made from
Inventin ensures maximum heat recovery with minimum sound emissions and maximum airow.
The iV14-Zero ventilation unit is a ventilation unit with
simple airow and works according to the principle of
heat recovery by changing the direction of the fan.
The integrated thermal accumulator charges itself with
heat energy from the indoor air as it ows to the exterior
(extract air). After 70 seconds, the Xenion reversible
fan changes direction. When the fan changes direction,
it releases the stored heat energy into the incoming
outdoor air (supply air).
For this principle to work correctly and to ensure pressure stability in the room, the supply air
volume must always correspond to the extract air volume, i.e. at least two iV14-Zero ventilation
units are required. These are operated in pairs in push-pull mode: another ventilation unit is as-
signed to the ventilation unit that delivers supply air and at the same time removes used extract
air from the interior to the outside.
The iV14-Zero features especially quiet operation. The patented sound insulation concept is
based on the combination of the sound insulation lining made of Inventin with the Xenion re-
versible fan. The sound insulation lining eectively absorbs sound waves from outside and from
the unit itself (sound transmission and inherent sound). The arrangement and design of the fan
blades additionally reduces the sound transmission from outside.
Thanks to a high pressure build-up and the active speed control of the motor (integrated wind
pressure stabiliser) in the Xenion reversible fan, the air ow in the system is kept almost constant
even in the event of weather-related pressure uctuations. Thus, the sensitivity of the air ow to
pressure uctuations corresponds to class S3 according to DIN EN 13141- 8 (max. 30 % air ow
deviation at ± 20 Pa).
In order to ensure the full functioning of the ventilation unit throughout the entire year, a tempera-
ture sensor is integrated into the Xenion reversible fan. This measures the temperature of the air
ow. If the temperature falls below +5 °C, the reversible fan is automatically switched to extract
air mode for 4 cycles. The thermal accumulator heats up again and prevents cooling of the interi-
or due to cold supply air.
During this phase, the operating mode that has been set on the controller is ineective.
Subsequently, the controller switches the ventilation unit back to the originally selected mode.
As standard, a washable ISO Coarse 60 % class dust lter is integrated into the inner cover. This
lters coarse dust and allergenic particles (such as coarse ower pollen) from the air before they
can enter the interior. The dust lters can be used regardless of the season.
Optional pollen and activated carbon lters are available for special requirements.
A decentralised ventilation system is based on the free movement of air between individual pairs
of ventilation units. Therefore, internal doors must not have air-tight seals. Provide suitable air
transfer measures to create a room network: an air gap of about 10 mm below the door, unscrew
the hinges by 5 mm, use a ventilation grille or similar (cross ventilation).
70 s