Vortex DBF-DEDPV User manual

IMPORTANT SAFETY
INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DBF-DEDPV
— INSTALLATION GUIDE
Dryer booster fan with integral
control and integrated lint trap.

2480 BOUL. DES ENTREPRISES TERREBONNE, QUEBEC J6X 4J8
450 477.1100 | ATMOSPHERE.COM
READ AND SAVE THESE INSTRUCTIONS
WARNING — TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING :
A - Your dryer installation incorporates a dryer exhaust power ventilator (DEDPV)
incorporating a lint trap.
B - Your dryer depends on the DEDPV for its safe and ecient operation. Operating your
dryer without a functional DEDPV will result in inecient dryer operation, excess energy
consumption and a possible re hazard. See warning light on DEDPV front panel.
C - The DEDPV shall be permanently installed within the space in which the dryer
is installed. In the case of a dryer installed in an alcove provided with a door, the DEDPV
shall be installed within the alcove or be installed immediately adjacent to the doors of the
alcove. The DEDPV shall be located where it will be readily visible after the dryer is installed
without opening any doors other than those necessary to access the dryer.
WARNING — IF A CONTINUOUS ALARM SOUNDS OR A VISUAL ERROR INDICATOR IS PRESENT,
DO NOT OPERATE THE CLOTHES DRYER. CONTACT YOUR SERVICE PERSONNEL
• Do not install in an exhaust ductwork of a clothes dryer whose instructions prohibit the
installation of a clothes dryer booster fan (DEDPV).
• Do not install in an exhaust ductwork where the equivalent duct length is less than 25 ft
(7.62 linear metres).
• The VTX-DEDPV is suitable to overcome an equivalent duct length of 130 feet
(39.6 meters) of 4 inch diameter galvanized steel duct, and to maintain an air velocity
of 1200 fpm (6.10 m/s).
• Do not exhaust air in excess of 167F (75C) and do not install less than linear 4ft (1.21m)
from clothes dryer exhaust outlet.
• Do not install less than 4 linear feet (1.21 linear meters) or more than 45 linear feet (13.71
linear meters) from clothes dryer exhaust outlet.
• Insulated dryer duct shall not be used upstream of the ventilator.
• The ventilator must not be used in conjunction with high output dryers.
• For general ventilating use only. Do not use to exhaust hazardous or explosive materials
and vapors.
• The installation must comply with local electrical and mechanical building codes,
and must be inspected and accepted by local authorities having jurisdiction.
INSTALLATION GUIDELINES
TO PREVENT THE POSSIBILITY OF DRYER FAN CAVITATION AND/OR EXHAUSTING EXCESS
HEAT REQUIRED FOR THE DRYING CYCLE AND COMPROMISING DRYING TIMES, BOOSTER FAN
AIRFLOW MUST NOT EXCEED THE DRYER FAN CAPACITY.
Page : 2

Ⓒ 2022 ATMOSPHERE INC.
REV R-1122
DBF-DEDPV
The DBF-DEDPV incorporate a booster fan, a lint trap and an integrated indicator panel.
Mounting —
DBF-DEDPV
The DBF-DEDPV is designed to be installed
at a minimum distance of 4 linear feet (1.21
meter) from clothes dryer exhaust outlet.
The visual indicator shall be visible to the
dryer operator and the lint trap shall be easely
accessible to the operator for cleaning. Refer
to maintenance instructions for inspection
recommendations. All duct connections
should be properly sealed to prevent leakage
and loss of fan performance.
Roof exhaust
Wall exhaust
Page : 3

2480 BOUL. DES ENTREPRISES TERREBONNE, QUEBEC J6X 4J8
450 477.1100 | ATMOSPHERE.COM
STEP 1 — Install the metal housing
Spacing : Ensure to leave the appropriate
spacing corresponding to the drywall tickness
1/2’’ or 5/8’’ between the face of the stud and
the front of the box edge corresponding to
distance ‘’D’’ as shown above.
STEP 3 — Install Ductwork
Install 4’’ rigid galvanized duct on inlet and
outlet. Do not use screw to attach the duct to
the DBF-DEDPV duct adapter, use aluminum
tape to seal the connections.
STEP 2 — Install the metal housing
Mount housing directly to the stud using pro-
vided wood or metal screws. Ensure to use the
oblong slot.
Orientation : Refer to the orientation sticker to
install the housing in the proper orientation.
STEP 4 — Electrical connection
A - Install the electrical connector to the
housing.
B - Bring a 2/14 AWG wire from a dedicated
circuit.
C - Connect the junction box connector wires
to the 115 V supplied wires and the housing
ground wire.
D - Close back the junction box with the
supplied screw.
Page : 4

Ⓒ 2022 ATMOSPHERE INC.
REV R-1122
MORE —
INSTALLATION INSTRUCTIONS
STEP 5 — Frame isolation
Once the drywall is installed, insert the frame
inside the housing ensuring that it is in the
proper orientation. The two-front holes
should be face down as shown above.
STEP 7 — Fan connection
Before inserting the fan, connect the
DBF-DEDPV male connector to the junction
box female connector.
A - Insert the fan unit in the housing.
STEP 6 — Frame xation
Before xing the frame to the housing with
the provided screws, ensure that the screw
holes in the frame are aligned with screw
holes in the housing. If the holes are not
aligned, loosen the screw that holds the hous-
ing to the stud and adjust the depth of the
housing until the holes are aligned.
STEP 8 — Fan unit locking procedure
B - Push the top fan unit towards the housing.
C - Tilt the fan unit as shown on the above.
D - Slide the fan unit towards the top.
Page : 5

2480 BOUL. DES ENTREPRISES TERREBONNE, QUEBEC J6X 4J8
450 477.1100 | ATMOSPHERE.COM
STEP 9 — Fix the fan unit
Once the holes of the fan unit are aligned with
the holes of the housing, put and hand tight-
en the metal screws. Ensure to not overtight
to avoid stripping the holes of the housing.
STEP 11 — Warning notication
Apply the provided warning and operational
stickers on the unit.
STEP 10 — Lint tray insertion
Insert the lint tray in the fan unit.
Page : 6

Ⓒ 2022 ATMOSPHERE INC.
REV R-1122
OPERATION
DBF-DEDPV Calibration procedure
IMPORTANT — ENSURE ALL OF THE FOLLOWING ARE PERFORMED BEFORE SUPPLYING POWER
TO THE DBF-DEDPV.
• Conrm that the power of the clothes dryer is turned o.
• Conrm all lint traps are empty of lint and reinstalled in their proper position.
• Conrm the clothes dryer is empty of clothing.
• Conrm the door on the dryer is closed.
• From the electrical panel, turn on the power to the DBF-DEDPV.
NOTE — Within 10 seconds of the DBF-DEDPV being powered on, it will come on and run for up
to 20 seconds. This calibration period will only happen when the DBF-DEDPV is powered for the
rst time. The blue indicator light will ash during calibration mode and after calibration mode,
the motor and the light will shut o.
The DBF-DEDPV is now calibrated and the clothes dryer can be used.
NOTIFICATION PANEL STATUS MODE
CALIBRATION MODE (Flashing blue light)
PROPER VENTING MODE (Steady green indicator light)
When the DBF-DEDPV is on, the green indicator light will be continuously on.
PRESSURE FAULT MODE (Flashing orange indicator light)
If, at any time during the calibration or operating cycle of the DBF-DEDPV, a ashing orange
indicator light appears, the DBF-DEDPV pressure sensor is detecting a rise of static pressure in the
duct due to a blockage to the system. The DBF-DEDPV will continue to work but you must stop
the clothes dryer immediately and have the vent system inspected by a qualied service provider.
The power to the DBF-DEDPV will need to be turned o to turn the DBF-DEDPV motor o so you
can clear the faulty duct condition and/or remove the obstruction. The DBF-DEDPV calibration
cycle will need to be performed once more. (See Troubleshooting for complete details)
CIRCUIT FAILURE MODE (Flashing pink indicator light)
If, at any time during the calibration of operating cycle a ashing pink indicator light appear the
DBF-DEDPV is not functioning properly due to a circuit or motor failure, stop the dryer immedi-
ately, turn o the power of the DBF-DEDPV and contact the manufacturer.
TEMPERATURE FAULT MODE (Flashing red indicator light)
The DBF-DEDPV is equipped with a non-resettable thermal fuse link which will trigger in case of a
re. This is a safety design feature to prevent the DBF-DEDPV from operating during abnormal or
dangerous drying conditions. If this occurs, contact the manufacturer.
Page : 7

2480 BOUL. DES ENTREPRISES TERREBONNE, QUEBEC J6X 4J8
450 477.1100 | ATMOSPHERE.COM
RECOMMENDED MAINTENANCE
Depending on use, but no longer than once a year, Atmosphere recommend cleaning the clothes
dryer exhaust vent. On an annual basis make sure that exhaust hood apper or backdraft damper
are clean of lint and moves freely. The DBF-DEDPV motor is maintenance free. If the DBF-DEDPV
is not functioning as it should, perform the calibration procedure. (See calibration instructions for
complete details)
Fan impeller may accumulate lint. Periodic inspection, based upon clothes dryer usage, should be
performed to ensure that it is not obstructed or loaded with lint.
To inspect and clean the impeller :
• Turn o power at the source
• Remove the fan unit from the housing of the DBF-DEDPV and clean any lint buildup
on the impeller and near the inlet and outlet.
• Reinstall the fan unit. Turn power back on and recalibrate the unit. (See calibration
instructions for complete details)
TROUBLESHOOTING
IMPORTANT — All faults are indicated by a dierent ashing indicator light or no lights at all on
the notication panel. All faults must be investigated as outlined below and the DBF-DEDPV must
only be turned on once a thorough investigation of the clothes dryer and vent system has been
performed by authorized service provider. Perform DBF-DEDPV calibration procedure to clear any
faults once investigation is complete.
No Indicator Light | DBF-DEDPV not operating when clothes dryer runs.
• The DBF-DEDPV is interlocked to the dryer by sensing the pressure inside the exhaust
duct when the dryer turns on.
• Clothes dryers are equipped with operating temperature controls that monitor drying
temperatures. Maximum exhaust temperatures should not exceed 167°F. If the safety
thermal fuse in the DBF-DEDPV trips, the clothes dryer is operating outside standard
code limits. Contact the clothes dryer manufacturer or authorized service provider and
replace the DBF-DEDPV.
• If the clothes dryer is operating normally, and there is no green indicator light on the
notication panel, stop the clothes dryer immediately and have the vent system
inspected and cleaned by an authorized service provider.
PRESSURE FAULT MODE (Flashing orange indicator light)
If at any time during the calibration or operating cycle of the DBF-DEDPV and the clothes dryer
there is excessive positive pressure of +0.16” W.C. sensed for more than four minutes, the noti-
cation panel will show a ashing orange indicator light. Stop the clothes dryer immediately. Have
the vent system inspected and cleaned by an authorized service provider. This is an indication of
excessive back pressure in the vent system
Page : 8

Ⓒ 2022 ATMOSPHERE INC.
REV R-1122
WIRING DIAGRAM
Page : 9

2480 BOUL. DES ENTREPRISES TERREBONNE, QUEBEC J6X 4J8
450 477.1100 | ATMOSPHERE.COM
WARRANTY
Ten (10) Year Warranty
This warranty supersedes all prior warranties
DURING ENTIRE WARRANTY PERIOD — Atmosphere will repair or replace any part which has
a factory defect in workmanship or material. Product will need to be returned to the Atmosphere
factory, together with a copy of the purchase invoice and identied with RMA number.
FOR FACTORY RETURN YOU MUST :
• Have a Return Materials Authorization (RMA) number. This may be obtained
by contacting Atmosphere at [email protected]. Please have a copy of the purchase
invoice available.
• The RMA number must be clearly written on the outside of box or it will be refused.
• All parts and/or product will be repaired/replaced and shipped back to buyer.
No credit will be issued.
OR
The distributor may place an order for the warranty part and/or product and will be invoiced.
The distributor will receive a credit equal to the invoice only after product is returned, prepaid,
and veried to be defective.
ATMOSPHERE WARRANTY TERMS DOES NOT PROVIDE FOR REPLACEMENT WITHOUT CHARGE
PRIOR TO INSPECTION FOR A DEFECT. REPLACEMENTS ISSUED IN ADVANCE OF DEFECT IN-
SPECTION ARE INVOICED AND CREDIT IS PENDING INSPECTION OF RETURNED MATERIAL.
DEFECTIVE MATERIAL RETURNED BY END USERS SHOULD NOT BE REPLACED BY THE DISTRIB-
UTOR WITHOUT CHARGE TO THE END USER, AS CREDIT TO DISTRIBUTORS ACCOUNT WILL BE
PENDING INSPECTION AND VERIFICATION OF ACTUAL DEFECT BY ATMOSPHERE.
THE FOLLOWING WARRANTIES DO NOT APPLY :
• Damages from shipping, either concealed or visible. Claim must be led with freight
company.
• Damages resulting from improper wiring or installation.
• Damages or failure caused by acts of God, or resulting from improper consumer
procedure, such as :
1. Improper installation
2. Improper maintenance.
3. Misuse, abuse, abnormal use, or accident and incorrect electrical connections.
4. Removal or any alteration made on the Atmosphere label control number
or date of manufacture. Any other warranty, expressed, implied or written, and to
any consequential or incidental damages, loss or property, revenues, or prot, or
costs of removal, installation or reinstallation, for any breach of warranty.
Page : 10

Ⓒ 2022 ATMOSPHERE INC.
REV R-1122
WARRANTY INVALIDATION
The user must keep a copy of the purchase invoice to verify purchase date.
This warranty gives you specic legal right and is subject to an applicable consumer protection
legislation. You may have additional rights which vary from state to state.
LIMITATION OF WARRANTY AND LIABILITY
This warranty does not apply to any Atmosphere product or part which has failed as a result of
misinstallation or abuse, incorrect electrical connections or alterations made by others, or use
under abnormal operating conditions or misapplication of the product or parts. Atmosphere will
not approve any payment for any repair not made by us or our authorized agent without prior
written consent. The foregoing shall constitute our sole and exclusive warranty and our sole ex-
clusive liability, and is in lieu of any other warranties, whether written, verbal, implied or statutory.
There are no warranties which extend beyond the description on the page hereof. In no event,
whether as a result of breach of contract, or warranty or alleged negligence, defect incorrect
advice or other causes, shall Atmosphere be liable for special or consequential damages, includ-
ing but not limited to, loss of prots or revenue, loss of use of equipment or any other associated
equipment, cost of capital, cost of substitute equipment, facilities or services, downtime costs or
claims of customers of purchase for such damages. Atmosphere neither assumes or authorizes
any person to assume for it any other liability in connection with the sale of product(s) or part(s).
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damag-
es so the above limitations and exclusions may not apply to you.
WARNING — ATMOSPHERE reserves the right to make technical changes. For up-to-date docu-
mentation, please refer to www.atmosphere.com
Page : 11
Table of contents
Other Vortex Fan manuals
Popular Fan manuals by other brands

Hunter Pacific
Hunter Pacific Concept installation manual

AC Infinity
AC Infinity RAXIAL Series user manual

KLASS Fan
KLASS Fan MODULO P1 Series user manual

Steel City
Steel City 56111CFB-BHL instruction sheet

Tornado
Tornado HI-FAN-16WMPRO-1P instruction manual

Fanimation
Fanimation Treventi FP2500 Series owner's manual