Invixium IXM TITAN User manual

IXM TITAN Installation Guide

Glossary
Earth Ground
Device Handling and Cleaning
IXM Install Kit for TITAN
TITAN
I/O Cable: Top Connector Pin Out
I/O Cable: Bottom Connector Pin Out
Hardware Tools Required For Installation
Hardware Installation Steps
Connections for Power
Connections for Communication
Connections for Operation
Connections for HDMI Out
Software Installation System Requirements
Software Installation Steps
Notices
Support
3
4
5
6
7
10
11
12
13
17
19
23
26
27
28
30
34
Table of Contents
Copyright 2019
INVIXIUM

ACP Access Control Panel
COM Common
DAC Door Access Control
DOS Door Open Schedule
DSP Door Strike Power
EGND Earth Ground
ESD Electrostatic Discharge
GND Ground
IXM INVIXIUM
LED Light Emitting Diode
NC Normally Closed
NO Normally Open
OTG On-the-Go
RLY Relay
RX Receive
SGND Signal Ground
SPI Specific Purpose Input
SPO Specific Purpose Output
TX Transmit
USB Universal Serial Bus
WDATA Wiegand Data
WGND Wiegand Ground
VDC Volts Direct Current
VIN+ Power Positive (12-24 VDC)
VIN- Power Return
Glossary
3
Metal Mounting
Plate
Wired Back
Cover
Temporary Back
Cover
Copyright 2019
INVIXIUM

For protection against ESD, which may cause damage or malfunction to the IXM device, Invixium recommends the use of the ground
connections between each IXM device and a high quality Earth Ground available at the install site. Please note that installation of any
IXM device should be performed by licensed electricians.
An Earth Ground wire with lug is provided in the IXM Install Kit. The lug of the Earth Ground wire should be fastened with a screw to the front
of the mounting plate. The other end of the Earth Ground wire should be connected to the high quality Earth Ground connection on site. When
the IXM device is installed onto the mounting plate, this Earth Ground lug will make direct contact with the Metal Back plate of the IXM device,
thus allowing for proper grounding.
Please refer to page 12 onwards for step-by-step instructions for mounting plate, device and Earth Ground wire installation.
Earth Ground
Earth Ground WireEarth Ground
4
Copyright 2019
INVIXIUM

Handle with care, ensure not to drop or step on the device.
Perform occassional cleaning to eliminate a build-up of dust, dirt, oil and residual grime.
Do not use harsh or abrasive chemicals to clean the surface of the sensor, as this may cause permanent damage to the device.
Do not use sandpaper, steel wool, scouring pads, chlorine, ammonia, bleach, or any inappropriate products for cleaning.
Device Handling Do's
Do not install in areas with direct sunlight, high levels of humidity, extreme dust or flammable vapours.
Do not allow magnetic objects to come in close contact to any device.
Do not install near any heating elements or equipment.
Do not attempt to open or disassemble the device, as this will void the product warranty.
Do not deploy for any use other than its intended purpose.
Do not insert anything other than the correct fitting USB plug into the USB port, located at the bottom of the device.
Device Handling Don'ts
The component that will require most frequent cleaning is the sensor, as it experiences the most contact. The cleaning should be performed
with care and attention, as improper cleaning may damage the sensor or surrounding components.
Follow the steps below for proper sensor cleaning procedure:
1. Lightly moisten a new cotton swab or lint free polishing cloth with water or isopropyl alcohol.
2. Gently wipe the surface of the sensor with the moistened cotton swab or cloth.
3. Finish wiping the sensor again with a dry cotton swab or cloth.
Device Cleaning
WARNING
Copyright 2019
INVIXIUM 5

The IXM Install Kit for TITAN includes:
Copyright 2019
INVIXIUM 6
IXM INSTALL KIT
Metal Mounting
Plate
Wired Back
Cover
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
Dolphin Crimps
(qty 12)
Hex Key
Earth Ground Wire
Metal Mounting
Plate Screw
(qty 2)
Wall Mounting Screws
(qty 6)
INVIX
-
Micro USB Extension Cable

TITAN
Copyright 2019
INVIXIUM 7
Multi-color
LEDs
Mic
Corning Gorilla
Glass
Surge
Protection
Proximity
Sensor
5.0” IPS LCD
IP67 & IK10
21 Megapixel
Camera
Aluminium
Enclosure
Industrial Grade
Connectors
High intensity
LED Flash
Fingerprint or
Finger Vein Sensor
Aluminium
5.0” IPS LCD

Copyright 2019
INVIXIUM 8
270.89
93.30
19.50
89.13 81.60

TITAN Product & Mounting Plate Actual Dimensions in mm
INVIXIUM recommends printing this page in Actual Size
Copyright 2019
INVIXIUM 9
Angled
Front View
Side View
9.50
4.20
Front View
110
233
56
76.60
261.42
82.10
B
30

I/O Cable: Top Connector Pin Out
Pin
Wire Wire ColorApplicationLabel ApplicationLabelPin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23-30
RESERVED
RS232_RX
RESERVED
EGND
SGND
RS485_T*
RS485_D+
WDATA_OUT0
V_INPUT+
WDATA_OUT1
V_INPUT-
WGND
RESERVED
RESERVED
TCP/IP
Green
Red
White
Black
Black/Green
Green/Red
Green/Red
RJ45 Receptacle
Wiegand Data Output Line 0
Power (12 to 24 VDC)
Wiegand Data Output Line 1
Power Ground
Ground for Wiegand
Reserved for Future Use
Reserved for Future Use
Ethernet of PoE+
RESERVED
RS485_D-
RLY_NC
WDATA_IN0
RLY_COM
WDATA_IN1
RLY_NO
Reserved for Future Use
RS232 - Data Receive
Reserved for Future Use
Earth Ground
RS232_TX
Green/Red
Orange/White
Green/Red
Green/Yellow
Black/Red
Blue/Red
Blue
Green/Red
Blue/Black
White/Red
Green/White
Grey
White/Black
Grey/Red
Purple/White RS232 - Data Transmit
Signal Ground
RS485 - Terminated (Optional)*
RS485 - Non Inverting Line
Reserved for Future Use
RS485 - Inverting Line
Relay NC
Wiegand Data Input Line 0
Relay Common
Wiegand Data Input Line 1
Relay NO
Wire Wire Color
NOTE
Copyright 2019
INVIXIUM 10
Back View
Wired Back Cover
Front View
7KLVSLQLVRSWLRQDODQGVKRXOGEHXVHGLIWHUPLQDWLRQ
is required. To do this, short the RS485_T wire with
RS485_D+ wire.
RJ45 Receptacle
RESERVED
RESERVED
RESERVED
RLY_NC
RLY_COM
RLY_NO
EGND
RS485_T
WDATA_OUT0
WDATA_IN1
RS485_D+
SGND
RS232_TX
RS232_RX
WDATA_IN0
RS485_D-
RESERVED
V_INPUT-
V_INPUT+
WDATA_OUT1
WGND
RESERVED

I/O Cable: Bottom Connector Pin Out
Copyright 2019
INVIXIUM 11
Back View
Front View
Pin
Wire Wire ColorApplicationLabel ApplicationLabelPin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
DAC_SUPPLY
SPO1
RESERVED
SPO2
RESERVED
SPO3
ACP_LED1
SPI_GND
DAC_IN3
DAC_OUT
DAC_IN_GND
RESERVED
RESERVED
RESERVED
Ground for SPI
DAC Input 3
DAC Output
Ground for DAC Inputs
Reserved for Future Use
Reserved for Future Use
Reserved for Future Use
SPO_GND
ACP_LED2
SPI1
ACP_LED_GND
SPI2
DAC_IN1
SPI3
DAC_IN2
Purple
Orange/Yellow
Green/Red
Yellow/Green
Green/Red
Green/Orange
Brown
Black/Orange
Yellow
Yellow/Cyan
Black/Yellow
Cyan/Brown
White/Purple
Brown/Yellow
Purple/Yellow
Door Strike Power
Specific Purpose Output Line 1
Reserved for Future Use
Specific Purpose Output Line 2
Reserved for Future Use
Specific Purpose Output Line 3
ACP LED 1 Feedback
Ground for SPOs
ACP LED 2 Feedback
Specific Purpose Input Line 1
Ground for ACP LED Feedback
Specific Purpose Input Line 2
DAC Input 1
Specific Purpose Input Line 3
DAC Input 2
Wire Wire Color
Wired Back Cover
23
24
25
26
27
28
29
USB0_VBUS
USB1_VBUS
USB0_D-
USB1_D-
USB0_D+
USB1_D+
USB0_GND
USB Line 0 Host interface
USB Line 1 Host interface
USB Line 0 Host interface
USB Line 1 Host interface
USB Line 0 Host interface
USB Line 1 Host interface
USB Line 0 Host interface
30 USB1_GND
Black/Cyan
Blue/White
Orange
Black/White
Green/Red
Green/Red
Green/Red
Red/White
Red/Grey
White/Black
White/Grey
Green/Black
Green/Grey
Black/Red
Black/Red USB Line 1 Host interface
DAC_SUPPLY
RESERVED
ACP_LED2
ACP_LED_GND
DAC_IN1
DAC_IN2
RESERVED
ACP_LED1
USB0_GND
USB0_D+
RESERVED
DAC_IN_GND
DAC_IN3
USB0_D-
USB0_VBUS
SPI_GND
SPI3
SPO_GND
SPO3
SPO2
SPO1
SPI2
SPI1
DAC_OUT
RESERVED
USB1_D-
USB1_D+
USB1_GND
RESERVED
USB1_VBUS

Hardware Tools Required For Installation
*Depending on the mounting surface, the Power Drill and Hammer may not be required.
Installation of any IXM device should be performed by licensed electricians.
NOTE
Pencil
Hammer*
Power Drill*
Ratchet-style Crimping tool
Measuring Tape
Battery powered
Screwdriver
Manual Screwdriver
Copyright 2019
INVIXIUM 12

1Ensure Power is Off
This protects the device being installed.
2 IXM Install Kit
Remove the following items from the kit:
4Drill Holes
If required, drill holes where marked and install the appropriate
wall anchors (not included) using the hammer.
3Mark the Screw Holes
INVIXIUM recommends the use of
all 6 holes for mounting.
Refer to diagrams from page 9
onwards for actual dimensions.
Ideal mounting height is 115-120 cm
from the ground to the bottom
of the device. But also be sure
to align the device in case of
multiple installations.
Copyright 2019
INVIXIUM 13
ON
OFF
Holes for mounting
on Gang box
(Single Gang)
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
INVIX-

6Insert Screws
Align the holes of the mounting plate with the wall anchors
and attach the mounting plate with the screws
provided in the IXM Install Kit.
INVIXIUM recommends
the use of an electric or
battery-powered
screwdriver
for this step.
5 Get Wires
Get access to the installation wires either from
behind the wall or from the wiring conduit.
Feed wires through the
square hole of the
mounting plate.
7Identify the Connections:
DC Power
VIN+
VIN-
EGND
PoE
RJ-45
Receptacle
EGND
Power & Grounding
1
Communications RS-485
SGND
RS-485+
RS-485-
Ethernet
RJ-45
Receptacle
USB
RS-232
RS-232_RX
RS-232_TX
SGND
Operations ACP
ACP_LED1
ACP_LED2
ACP_LED_GND
WDATA_OUT0
WDATA_OUT1
WGND
DAC
RLY_NC
RLY_COM
RLY_NO
DAC_IN1
DAC_IN2
DAC_OUT
DAC_SUPPLY
2
3
OR
OR OR OR
OR Refer to pages 17 & 18 for Power connections,
pages 19-22 for Network or Serial Communication
connections and pages 23-25 for Operation
connections.
Copyright 2019
INVIXIUM 14

DOLPHIN
8A Make the Connections
Connect the required wires using the Dolphin crimps provided in the IXM Install Kit (or any similar crimps) and a ratchet style
crimping tool. Insert two wires (no stripping required) into the open end of the crimp and then using the crimping tool, clamp
down on the middle of the crimp.
8B Connect Earth Ground
Connect the lug of the Earth Ground wire directly to the front of the mounting plate using one of the Wall
mounting screws. Ensure that the lug is secured tightly so as to make the necessary contact between the
device and the mounting plate. Connect the other end of the Earth Ground wire to the Earth Ground
connection of the install site with a crimp.
Ensure all required connections are made to each device in the setup prior to turning on the power.
Checklist:
Connections for Power & Ground (DC or PoE+)
Connections for Communications (Ethernet, RS-485, RS-232 or USB)
Connections for Operation (ACP or DAC)
Any other connections that may be required based on the application (SPO or SPI)
Copyright 2019
INVIXIUM 15
Earth Ground
Wire Lug

10 Secure the Device
9Attach the Device
Copyright 2019
INVIXIUM 16
Take the IXM device and unscrew the Temporary Back Cover, keeping
the screws handy. Connect the Wired Back Cover to the back of the
device by lining up the connectors. Secure the Wired Back Cover with
the same screws. Next, hang the IXM device onto the mounting plate as
shown in the series of diagrams below
12
Finally, secure the device on the bottom to the mounting
plate with the Metal Mounting Plate screw provided
in the IXM Install Kit.

Connections for Power
INVIXIUM recommends:
•
12-24 VDC regulated power supply (Safety tested and FCC/IC/CE certified)
• Dedicated Power Supply for IXM TITAN (minimum 2A @ 12 VDC)
•
Use of a battery back-up or UPS with built-in surge protection
•
If sharing power supplies, ensure that each TITAN is supplied with minimum 2A per
device (i.e. Powering 2 devices will require a supply with output current of 4A) Power Connections
VIN+
VIN-
EGND
Product Warranty is void if improper power (under or over) is supplied to the device.
WARNING
TITAN
DC Power Supply
UPS
EGND
VIN+
VIN-
UPS
Copyright 2019
INVIXIUM 17

INVIXIUM recommends:
• A centralized Power Sourcing Equipment (PSE) for full PoE deployments (not included)
• Use of a battery back-up or UPS with built-in surge protection
Available on MERGE, SENSE 2, TOUCH 2 and TITAN
Connections for Power Over Ethernet (PoE+)
Both IEEE 802.3at power transmission modes (A and B) are supported.
NOTE
TITAN FPU
TITAN FV
Ethernet/PoE Connections
TX+
TX-
RJ45_PIN4
RX+
RX-
RJ45_PIN7
Copyright 2019
INVIXIUM 18

Ethernet and Wi-Fi Communication
Ethernet:
• Switch/Router required
• CAT 5 cabling or better
WiFi:
• Wireless router to LAN/WAN
• 802.11ac protocol
• WEP, WPA and WPA2 encryptions supported
• DHCP enabled by default
TITAN FPLV TITAN FPU TITAN FV
Router connected
to LAN/WAN
R
outer connected
to LAN/WAN
IXM WEB
IXM WEB
Copyright 2019
INVIXIUM 19

RS-485 Network Communication
INVIXIUM recommends:
• Daisy chain configuration
• Maximum 31 devices in the network
• Both RS-485 converter and the last device in the chain should be terminated (not included, refer to NOTE below for correct Resistor vaues)
• Connect the IXM device to PC via RS-485-to-Serial (RS-232 or USB) Converter
• Maximum cable length of 1200m (4000 ft.) at 9600 bps baud rate
R = 120 ohms for Standard RS-485 Cabling
R = 100 ohms for CAT5/6 Cabling
NOTE
RS-485 Connections
SGND
RS485_D+
RS485_D-
(6)
(8)
(10)
RS-485 to USB
Converter
IXM WEB
TITAN
Copyright 2019
INVIXIUM 20
Table of contents
Other Invixium Touch Terminal manuals