manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. IONZA
  6. •
  7. Dispenser
  8. •
  9. IONZA Alka Jug User manual

IONZA Alka Jug User manual

BPA-free
Unscrew the lter cartridge from the funnel reservoir
Screw the new cartridge into the funnel reservoir and
repeat steps 2) to 5) under Before Using.
Re-set and re-activate the indicator as before.
• You can easily change the number of users by
entering the users’ setting mode: quickly double
press the button, then repeat steps 5b and 5c. When
the number of users is changed, the cartridge life is
recalculated automatically.
• Keep replacement cartridge in the original sealed
wrapper while not in use and store in a dry cool
place.
• When lling the funnel reservoir, do not place lter
cartridge opening directly under the running water.
NOTE:
REPLACING THE FILTER CARTRIDGE:
When the blinking warning symbol (‘X’) appears on the
cartridge image in the display, it means that the lter cartridge
should be replaced within one week. As the
week passes, all symbols on the screen start
blinking reminding you that lter cartridge life
has expired. Replace the lter cartridge.
1
2
3
4
5
enjoy !
1
2
3
BEFORE USING:
Clean all components of the Alka Jug. All parts can
be washed in dishwasher except lid - clean the lid by
hand.
Clean surface of lter cartridge, then screw it rmly into
the bottom of the funnel reservoir of the jug. Place the
unit into the jug.
Fill the funnel reservoir with water and let the water
lter into the jug. Discard the water and repeat the
entire process. This will rinse away any loose activated
carbon particles and prepare the lter cartridge for use.
NOTE: Carbon particles are not harmful to consume.
The jug can be lled with 1.5 litres of water at a time.
When this has passed through the cartridge into the
jug it is possible to ll the reservoir more as the jug
itself has a capacity of up to 2.5 litres. (Do not overll
the reservoir or water will ow out into the handle.
overow
outlet
water
level
CARTRIDGE MEDIA:
Negative ion ceramic balls: alkaline
ionized water with pH 9.5, –150mv
ORP;
Activated Carbon: removes chlorine,
odour, colour, puries water
Ion exchange resin: softens water for
better taste.
FIR beads: for smaller cluster size
Natural Bio minerals: up to 90 different
minerals and trace elements
Acidic Neutral Alkaline
pH 3 pH 7 pH 10
Set up the electronic cartridge life indicator:
5a Press the button and hold it down for a few seconds
until symbols appear on the screen. Release the
button and the blinking symbol for users appears on
the screen.
5b Case 1: Four faces and cartridge icon (with cross
through) are blinking: double click button (a fast
double click), in order to nd one user (smiley face)
blinking, this allows you to change the number of
users. Go to 5c
Case 2: One user is blinking. Go to 5c
pH TESTING: The cartridge life is accurately tested by using
pH drops (Ionza pH test bottle): pour 20ml of Alka Jug water into
a glass, add 2 drops of testing liquid, and mix. The resulting colour
should be blue or purple, indicating an alkaline reading of pH9 to
9.5. When the colour becomes turquoise, the cartridge is exhausted,
and needs replacing. Testing means you will get the most life from
your cartridge. Please note: if your water source is acidic, water
from the Alka Jug won’t be as alkaline. It is possible to put the water
through the Alka Jug twice to achieve higher alkaline levels. Test
your source water for pH to see the difference.
COOKING: You can also use the
alkaline water for cooking wonderful
soups, stocks, rice and pasta.
5c Set the number of users by pressing the button
again until the desired number of users is displayed.
(Maximum is 4).
5d Next, press the button and hold it down for a few
seconds until symbols appear on the screen. The
indicator is activated. NOTE: The indicator will cut
off if the button is not pressed within 30 seconds of
programming the timer. If this happens, repeat the steps
avove.
To turn off the LCD display:
Press the button and hold it
for 20-30 seconds until the
LCD display turns off.
Users
symbols
Button
Cartridge
symbol
To get optimal benet we recommend drinking 1.5 -2L/day.
You get the most benet when you drink the water fresh. Fill
bottles to support you throughout the day. To preserve the
health properties best, use a vessel that you can cap.
5
DRINKING IONISED ALKALINE WATER:
Wash your jug and funnel reservoir regularly with soapy
water, rinse, and dry with a soft cloth.
For the lid to hold well on the jug, the reservoir needs to
be aligned with the jug’s top edge
HEALTH: Alkaline Ionised water supports the body in a variety
of ways to achieve good health. The alkaline minerals are used
to create alkaline buffers, the body’s natural process for buffering
and eliminating acidity from the tissues. Accumulation of acidity
encourages the development of inammation which underlies
the majority of adult illnesses. Water from your jug also offers you
antioxidants as well as better hydration. Water is best drunk at room
temperature rather than refridgerated as this cools down the digestive
system. There may be detox symptoms when drinking the water in
the rst few days.
CONGRATULATIONS on the purchase of your Alka
Jug.The jug is designed to offer you properties that help
the body detox, eliminate acidity and reduce the chance of
inammation in the body.

Popular Dispenser manuals by other brands

DeWalt DCE570 instruction manual

DeWalt

DeWalt DCE570 instruction manual

Franke STRX635B Installation and operating instructions

Franke

Franke STRX635B Installation and operating instructions

ViscoTec Preeflow eco-CONTROL EC200-K Operation and maintenance instructions

ViscoTec

ViscoTec Preeflow eco-CONTROL EC200-K Operation and maintenance instructions

U-Line H-2557 quick start guide

U-Line

U-Line H-2557 quick start guide

San Jamar Venue instructions

San Jamar

San Jamar Venue instructions

lancer Bar Bridge Operation manual

lancer

lancer Bar Bridge Operation manual

Greenway Home Products GWF8 Use & care guide

Greenway Home Products

Greenway Home Products GWF8 Use & care guide

Dover Wayne Helix WM048523 Service manual

Dover

Dover Wayne Helix WM048523 Service manual

Cornelius 2232 installation instructions

Cornelius

Cornelius 2232 installation instructions

Hampton Research HR8-165 user guide

Hampton Research

Hampton Research HR8-165 user guide

Bennett 3000 Series installation manual

Bennett

Bennett 3000 Series installation manual

Cornelius VIPER Service manual

Cornelius

Cornelius VIPER Service manual

MARPLAST 770 Use and maintenance manual

MARPLAST

MARPLAST 770 Use and maintenance manual

FISNAR DC50 operating manual

FISNAR

FISNAR DC50 operating manual

BOWMAN GN401-0111 manual

BOWMAN

BOWMAN GN401-0111 manual

Royal Catering RCCS-10 user manual

Royal Catering

Royal Catering RCCS-10 user manual

Nordson EFD 1500 Series operating guide

Nordson

Nordson EFD 1500 Series operating guide

Graco PrecisionSwirl 243402 Instructions-parts list

Graco

Graco PrecisionSwirl 243402 Instructions-parts list

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.