manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. IQ plus
  6. •
  7. Accessories
  8. •
  9. IQ plus 355 User manual

IQ plus 355 User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

September 2002 67970
IQ plus
®
355 Digital Weight Indicator
EMI Suppression Ferrite Installation
To reduce susceptibility to radiated EMI (electromagnetic interference) install a ferrite inside the indicator
enclosure for both load cell and serial cables.
Use the following procedure to install the ferrite (PN 66730) which is included in the IQ plus 355 parts kit.
1. Ensure power to the indicator is disconnected, then place the indicator face-down on an antistatic work
mat.
2. Remove the screws that hold the backplate to the enclosure body, then lift the backplate away from the
enclosure.
3. Strip cable insulation and shielding per cable grounding instructions, Section 2.3.1, PN 66503, I
Q plus
355 Installation
Manual
(and shown in Figure 1). Ensure there is sufficient cable lengths to loop once
around the ferrite, before reaching the cable connectors inside of the indicator (shown in Figure 2).There
should be 14" (36cm) for the load cell cable and 21" (54cm) for the serial communications cable. Tighten
grounding clamp nuts.
Figure 1. Grounding Clamp Attachments
Figure 2. Loop Diagram of Ferrite


Cord grip
Insulated cable
Foil (silver side out) Grounding clamp
Shield wire (cut)


Length of foil before folding
back on cable insulation
Cut insulation here
for foil-shielded cables
Braid
Cut insulation here
for braided cables
NOTE: Install lockwashers
first, against backplate,
under grounding clamp
Ferrite
Enclosure
backplate
Grounding
clamps
Kep nuts
2
IQ plus 355 EMI Suppression Ferrite Installation
4. Loop wires once around the ferrite (see Figure 2 on page 1). This should be done as close to the
enclosure entry as possible. Finish installation using cable mounts and ties to secure cables inside of
indicator enclosure.
5. Once cabling is complete, position the backplate over the enclosure and reinstall the backplate screws.
Use the torque pattern shown in Figure 3 to prevent distorting the backplate gasket. Torque screws to 15
in-lb. (1.7 N-m).
Figure 3. IQ plus 355 Enclosure Backplate
Setup switch access screw
Fillister head screws
10
9
8
7
4
3
1
2
56
Torque backplate screws to 15 in-lb (1.7 N-m)
Torque pattern