IQRF VCP-01B User manual

VCP-01B
IQVCP Visual Control Panel with Ethernet
HW version 1.01
User's Guide
© 2018 IQRF Tech s.r.o. www.iqrf.org User_Guide_VCP 01B_180118 Page 1

VCP-01B
Block schematics
© 2015 IQRF Tech s.r.o. www.iqrf.org User_Guide_VCP 01B_180118 Page 2
Description
VCP 01B is a visual control panel with touchscreen,
Ethernet and wireless connectivity and other features.
It is a generic equipment, i.e. the hardware is fixed and the
user can realize specific functionality by software only.
VCP 01B is intended for final production while the DS
VCP 01B should be used for application development.
Applications
• Solutions tailored to user's needs
• Control panel for arbitrary use (not for IQRF only)
• Home automation
• Access control
• Security systems
• Heating systems
• Wireless control panel
Key features
• Display/touchscreen 3.2“, 320 x 240 pixels, 65535 colors
• RTCC (real time clock/calendar)
• Main MCU PIC32MX7
• Secondary MCU for power management
• Micro SD card interface
• Ethernet, USB and RS485 interface
• Backup accumulator
• Internal antenna
• Very low power consumption in Sleep mode
• Wall assembly option

VCP-01B
Device differences
VCP 01B differs from VCP 01 in the following:
•RS 485 interface added, 3.3V or 5V levels selectable
•Graphic library extended by a set of MICRORISC functions
•Console CCP command interpreter added
•Tilt sensor LIS33DE and LIS2DH can alternatively be used
Electrical specifications (typical values unless otherwise stated)
Power supply 7 – 20V DC (terminal clamp) / 5.0 ± 0.35 V DC (micro USB)
Accumulator LI14500 700 1L, 3.7 V, 700 mAh, Li Ion, AA
Display DI QVGA 3.2 03 TFT LCD 3.2“, 320 x 240 pixels, 256 K colors
Supply current
operational 160 mA 1 (display backlight off)
280 mA 1 (display backlight on)
sleep mode 80 µA to 110 µA 2
power down mode 8 µA 2
accumulator charging 450 mA max.
Temperature range
operational 0 °C to +60 °C
accumulator charging 0 °C to +45 °C
Frequency range 868 MHz or 916 MHz (according to the TR module)
RF output power 3.5 mW
Supported TR modules TR 52BA (with on board PCB antenna)
Temperature sensor accuracy ±0.5 °C typ., ±3 °C max.
Dimensions 120 mm x 80 mm x 28 mm
Display size 8.1 mm (diagonal)
Weight: 143 g 3
Note 1: This current is increased due to charging in case of external supply (depended on the accumulator state).
Note 2: All peripherals shut down.
Note : Including accumulator and TR module, without micro SD card.
Absolute maximum ratings
Stresses above those values may cause permanent damage to the device. Exposure to maximum rating conditions
for extended periods may affect device reliability.
Supply voltage (VCC): 20.5 V DC (terminal clamp) / 5.5 V DC (micro USB)
Storage temperature: 30 °C to +80 °C
© 2015 IQRF Tech s.r.o. www.iqrf.org User_Guide_VCP 01B_180118 Page 3

VCP-01B
Hardware
VCP 01B is a generic equipment, i.e. the hardware is fixed and the user can realize specific functionality by software
only.
Power supply
VCP 01B is intended to be supplied by external stabilized 7 20 V DC connected to clamp or 5 V DC to micro USB
connector. If both are connected, the internal logic gives priority to the supply from the clamp. Accumulator serves as a
backup for external power source and should be charged from it. Input of external power (5V or up to 20V) is configured by
jumpers. See DS VCP 01 User's guide for settings. VCP 01B power is not switched off, deactivation is realized by Sleep or
Power down mode instead (see below).
MCUs
VCP 01B is controlled by main 32b microcontroller PIC32MX695F512L, up to 80 MHz, 121 pins. For power management
the 8b secondary microcontroller PIC12F615MF, 4 MHz, 8 pins is added.
Reset
VCP 01B reset (initialization/starting up) can be invoked by the pushbutton on the side of the case or by software. Software
has no influence upon the functionality of the pushbutton. However the secondary MCU might disconnect the main MCU
from its power source completely and thus preventing of normal functionality of the pushbutton.
Sleep mode
This is intended for current consumption minimizing, especially in idle or while supplied from the accumulator. It is possible
to switch off all functions and peripherals by software. Sleep can be invoked by the program and terminated e.g. by the
reset pushbutton.
Power-down mode
This is intended to further minimize current consumption by disconnecting main MCU completely. It is possible to instruct
secondary MCU to cut main MCU from its power source. If the main MCU is disconnected it is possible to connect back
main MCU power source by pressing user pushbutton. Then the main MCU is powered up and follows usual reset
procedure (initialization/starting up).
The secondary MCU also periodically checks the battery voltage level and cuts the main MCU from its power source if the
voltage level drops below a threshold of 3.00 V. The main MCU power source is connected back once the volatage level
rises above the specified threshold.
QVGA display
Display / touchscreen 3.2“ diagonal, 320x240 pixels RGB, 262144 colors (graphic library uses 65535 colors only), QVGA
TFT LCD, transmissive, with LED backlight and 16b data bus.
Proper display functionality requires a calibration (setting the touch sensors in accordance to display pixels) to compensate
variations in parameters due to temperature, tolerance of parts and so on. VCP 01 has the display factory calibrated and
this can also be done in application software whenever needed (3x3 touches in places indicated by an arrow). The
calibration is stored to the EEPROM.
LED backlight can be switched on/off by the software.
EEPROM memory
Capacity: 64 kb, serial interface SPI (shared with the TR module) 1 000 000 erase/write cycles (typ.).
Micro SD interface
VCP 01B has the SPI interface to standard Flash memory micro SD card. The memory can be put to the standby mode (by
the PWR_SD signal). VCP 01B is delivered without an SD card.
RS-485 interface
The RS 485 circuitry is supplied directly from external source. Thus, it works with external supply only. Default voltage level
is 5 V, alternatively 3.3 V is available on request.
Temperature sensor
Temperature can be measured by external sensor MCP9802 with I2C interface. It is not assembled in standard delivery.
© 2015 IQRF Tech s.r.o. www.iqrf.org User_Guide_VCP 01B_180118 Page 4

VCP-01B
Tilt sensor
3 axis linear accelerometer can be used e.g. for portrait/landscape view switching.
User pushbutton
The pushbutton functionality is fully under the user's control.
User LED
Dual color (red/green) inside the case. It is fully under the user's control, especially intended for service and debug.
Beeper
Beeper can be driven from the PWM module output or by software. The functionality is fully under the user's control.
TR module and antenna
Wireless IQRF transceiver module in SIM card format with built in PCB antenna, e.g. TR 52DA. Optional.
Ethernet
The ENC424J600 I/ML Ethernet controller by Microchip is used. The ENC424J600 is stand alone 10/100 Base T Ethernet
interface controller with integrated MAC & PHY, hardware cryptographic security engines and factory preprogrammed
unique MAC address. A 24 Kbyte on chip RAM buffer is available for TX and RX operations. The ENC424J600 have an
industry standard Serial Peripheral Interface .
CAN
Either 5 V level MCP2551 or 3.3 V level SN65HVD231 can be used.
The MCP2551 is a high speed CAN transceiver, fault tolerant device that serves as the interface between a CAN protocol
controller and the physical bus. The MCP2551 provides differential transmit and receive capability for the CAN protocol
controller and is fully compatible with the ISO 11898 standard, including 24V requirements. It will operate at speeds of up to
1 Mb/s.
The SN65HVD231 with sleep mode is intended for use in applications employing the CAN serial communication physical
layer in accordance with the ISO 11898 standard. The CAN controlled is designed to provide differential transmit capability
to the bus and differential receive capability at speeds up to 1 Mbps.
The CAN circuitry is assembled on request only.
Connections
Connection Pins Type
External power 2 Micro USB connector or alternatively Clamp connector
Accumulator 2 Soldering stripes
TR module 8 + 1 SIM connector + through hole soldering for possible mechanical fixation
RS 485 2 Clamp connector
USB 5 Micro USB connector
MCU programming (ICSP) and debugging (ICD) 5 Cable connector (assembled in DS VCP 01B only)
Micro SD card DM3AT SF PEJ (Hirose) connector
Temperature 5 Cable connector
Ethernet 8 RJ45 Hirose connector
JTAG 6 Soldering holes
The cable to the clamp connector can be connected after breaking the molded cover at the bottom of the case.
© 2015 IQRF Tech s.r.o. www.iqrf.org User_Guide_VCP 01B_180118 Page 5

VCP-01B
Software
Demo application
Sample programs for the main MCU inside the VCP 01B, for TR modules to demonstrate wireless connectivity and PC
demo for USB communication are available in the DS VCP 01B development set. Firmware of the secondary MCU is fixed.
Product information
Pack list
•VCP 01B without CAN circuitry and temperature sensor, with Demo application programmed, in Power down mode
•No TR module included
•Accumulator (soldered)
•Power source TY A6 microUSB ( 5V DC, 500 mA, stabilized, with micro USB connector)
Ordering codes
•VCP 01B Visual control panel
•DS VCP 01B Developemnt set for VCP 01B
Recommended options
•CAN circuitry Assembled on request only
•TR 52BA TR module with integrated antenna (other suitable types are also supported)
•Micro SD card
•CABUSBABMICRO 100 Micro USB cable
Document history
•180118 Bugs in operational supply current and MCU type fixed. Page Sales and service
updated.
•150219 Updated for VCP 01B.
•120328 Renamed from from GW QVGE 01A to VCP 01 and DS QVGA 03 to DS VCP 01.
•111010 Device differences added (page 3).
•110916 First release (for VCP 01 with secondary MCU).
© 2015 IQRF Tech s.r.o. www.iqrf.org User_Guide_VCP 01B_180118 Page 6

VCP-01B
Sales and Service
Corporate office
IQRF Tech s.r.o., Prumyslova 1275, 506 01 Jicin, Czech Republic, EU
Tel: +420 493 538 125, Fax: +420 493 538 126, www.iqrf.tech
E mail (commercial matters): [email protected]
Technology and development
www.iqrf.org
E mail (technical matters): [email protected]
Partners and distribution
www.iqrf.org/partners
Quality management
ISO 9001 : 2009 certified
Trademarks
The IQRF name and logo are registered trademarks of IQRF Tech s.r.o.
IC, S I, Microchip and all other trademarks mentioned herein are a property of their respective owners.
Legal
All information contained in this publication is intended through suggestion only and may be superseded by updates
without prior notice. No representation or warranty is given and no liability is assumed by IQRF Tech s.r.o. with respect to
the accuracy or use of such information.
Without written permission, it is not allowed to copy or reproduce this information, even partially.
No licenses are conveyed, implicitly or otherwise, under any intellectual property rights.
The IQRF ® products utilize several patents (CZ, EU, US)
On-line support: [email protected]
© 2015 IQRF Tech s.r.o. www.iqrf.org User_Guide_VCP 01B_180118 Page 7
Table of contents
Other IQRF Control Panel manuals
Popular Control Panel manuals by other brands

Dwyer Instruments
Dwyer Instruments Magnehelic A-286 Series Specifications-installation and operating instructions

Siemens
Siemens SINUMERIK MCP-S Series Equipment manual

Flybox
Flybox Vigilus Series installation manual

Telex
Telex LCP-16 installation guide

Mitsubishi
Mitsubishi FX-20P-E Operation manual

Schaudt
Schaudt DT 220 B instruction manual

Bentel
Bentel FireClass FC500 user manual

Haes
Haes MZAOV-1001 Installation, commissioning & operating manual

Intermatic
Intermatic P1353ME Installation, operation & service manual

OGI
OGI TotalArc BMS 460246 SOLAR POWER Operator's manual

Sonetonix
Sonetonix CS-BP8-B user manual

DeDietrich
DeDietrich MIT/E iSystem user guide