Iseo Zero1 Atlas Plus User manual

Atlas Plus
INSTALLATION GUIDE (EN)
ELECTRONIC SUPPORT SERVICE
iseozero1.com
®
i s e o .co m
Iseo Serrature s.p.a
Via San Girolamo 13
25055 Pisogne (BS)
ITALIA
Tel. +39 0364 8821
Non contractual document. Subjecet to change. Cod. 6000005E00013.1 - 07/09/2020
Atlas PLUS Installation Guide (EN) - © 2020 Iseo Serrature S.p.a. - www.iseo.com
Cod.5E002012
WARNINGS
https://www.iseo.com/it/en/download
Read this manual prior to use the devicein order to ensure a safe and proper use.
Preserve this manual as future reference.
The installation and maintanance of the devicemust be carried out by qualified technical staff, adequately trained by ISEO.
The instructions should be carefully followed during installation. These instructions and any maintenance instructions should be passed on by the installer to
the user.
No modifications of any kind are permitted, except for those described in these instructions.
The product must be destined only for the use for which it is expressly designed and therefore as web server controller for civil and industrial locations.
Any other use is considered improper and dangerous.
The electrical connection must bemade accordingtotheconstructor's instructions and respecting the regulations in force.
For all repairs, exclusively contact atechnical assistance center authorizedby the constructor.
Disconnect the power supply before carrying out any technical service that involves opening or accessing the internal parts of the product.
Dispose of the product separately from household waste, in accordance withlocal laws and regulations.
Ensure full recharge of the Atlas internal battery by running a full recharge cycle (24 hours), minimum every 6 months.
The calculation of the cables section must be performed by qualified staff.
Max cable length of LOCKBUS channel is 100 mt (sum of all branches).
Recommended voltage for LOCKBUS channel is 24 VDC.
In case of power failure the rechargeable battery inside the Atlas ensures power for 30 minutes max.
It is advisable to provide for an appropriate sectioning, aprotection switch upstream of the transformer.
For any technical assistance or repairs, contact only Iseo Serrature or an Iseo Zero1 authorised technical centre.
Iseo Zero1 reserves the right, without prior notice, to make all the necessary modifications to the product and to the instruction manual, for quality
improvements or manufacturing or marketing needs.
Atlas earth connection is mandatory.
Add Surge Protection Devices (SPD) to the mains, upstream the Atlas Master, when connected to Atlas Slaves, Actuators and Readers placed in outside
areas of the builing (not equipotential zones), according to the Lightning Protection Risk Assessment of your building and current legislations.
Riskof explosion if the battery is replaced with an incorrect type. Dispose of used battery accordingto your local environmental laws and rules.
ATTENTION
NiMH 7,2V 1500mA
NiMH battery pack
7,2 V - 1500 mAh

2. ATLAS OVERVIEW Connect to 192.168.0.184 from Google Chrome,
Microsoft Edge or Apple Safari Internet browser.
ATLAS
R
G
TX RX
CH
0
TX RX
CH
1
TX RX
CH
2
ATLAS
S1S3
J7
J17
J14
J4J5J11J6
FRONT SIDE BACK SIDE
S1
Reset
button
Ethernet
port
USB
ports
Power
supply
Lockbus
Channel
CH0
RS485
Channel
CH1
RS485
Channel
CH2
S3
Switch off
button
Serial
interface
(debug port)
TX/RX
Channels LED
Ethernet
activity LED
Red LED
(start and
switch off)
Green LED
(start)
Battery
operation LED
Power Supply
LED
S2
Wake-up
button
1. TECHNICAL FEATURES
Communication interfaces:
- 1 Ethernet interface TCP/IP 10/100 base T
- 1 LOCKBUS channel (CH0) to connect Stylos online readers and Actuators
(max 8 readers and 8 actuators).
- 2 RS485 channels (CH1/CH2) to connect F9000 online readers (max 1 per
channel)
- 1 USB 2.0 Type A
- 1 serial interface (debug)
Power supply:
- 12÷24 Vdc
- Maximum power consumption 10W (with no connected devices)
Internal Backup battery:
- 1500mAh (7,2Vdc) NiMH battery pack
- Estimated backup time: 30 minutes
CPU and memory:
- ARM 9 based CPU module
- 800MHz CPU clock
- 512MB Flash memory
- 64MB SDRAM
- 8GB Micro-SD
Operative system:
- Linux
Push buttons:
- S1 Reset (to manually reboot the Atlas)
- S2 Wake-up (to manually start the Atlas when OFF)
- S3 Switch off (to manually switch off the Atlas)
Housing:
- Desktop housing (black color)
- L x W x H = 167 x 110 x 53 mm
Environmental characteristics:
- Operating temperature: 0°C ÷ +50°C
- Storage temperature: -25°C ÷ +75°C
Conformity certifications:
- 2014/53/EU RED
- RoHS (electrical and electronic equipment).
- References standards: EN301 489-1, EN301 489-17, EN330 440,
EN60950-1, EN62209-2.
- For details see Declarations of Conformity available at iseo.com website
(download area).
Package contents:
- 1 Atlas Server for RFID and F9000 ON-LINE and OFF-LINE devices, with
connectors.
- 1 Power supply unit 230Vac/24Vdc - 1,65A (35W)
- Installation guide.

3. V364 RFID SYSTEM WIRING:
2 DOORS CONTROLLER CONNECTION EXAMPLE
ATLAS
S1S3
J7
J17
J14
J4J5J11J6
BACK SIDE
Devices consumption:
- ATLAS = 10 W
- Stylos = 3W
- Actuator = 3W
Suggested configuration for 2 doors
controller: max 4 Stylos readers.
12 VAC
S1
L 2L 1
P1 P2 LRL
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
LPW
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
DOOR 2
DOOR 2
(Actuator
cod.5E2501)
DOOR 2
(Stylos cod.5E1310126)
Back side view
circuit board
12 VAC
S1
L 2L 1
P1 P2 LRL
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
LPW
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
DOOR 1
DOOR 1
(Actuator
cod.5E2501)
DOOR 1
(Stylos cod.5E1310126)
Back side view
circuit board
Power supply unit:
24 VDC - 1,65 A (35 W)
For the Stylos address configuration
refer to the Stylos Installation Guide,
available at: iseo.com.
Wirings also applies to Atlas Standard
Total LOCKBUS channel cable length (sum of all
branches): MAX 100mt.
Conductor capacitance < 100pF/m.
Conductors electrical resistance max 90 ohm/Km.
Cable 3 x 0,75mm - AWG 18 NOT shielded
(the
calculation of the cables section must be verified
by qualified staff).
WIRING SPECIFICATIONS
LOCKBUS
(+) V ALIM
( ) GND
2
Wires colors reported in the wiring diagrams are just an example.
NOT
shielded

WIRING SPECIFICATION
Maximum Ethernet cable length between Atlas and F9000 Reder: 500mt.
Use an Ethernet cable FTP AWG24 CAT5E (and above).
Connect a resistance value of 120 ohm (1/4W), on both Atlas and F9000
Reader sides, as shown in the scheme.
Conductor capacitance < 100pF/m.
Conductors electrical resistance max 90 ohm/Km.
SER.A/B
SER.A/B
+ V Power
GND
Schield
S1S3
J7
J17
J14
J4J5J11J6
BACK SIDE
L 2L 1
P1 P2 LRL
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
LPW
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
DOOR 2
(Actuator cod.5E2501)
12 VAC
DOOR 2
DOOR 2
(F9000 reader
cod.E032**)
DOOR 1
(F9000 Reader
cod.E032**)
4. V364 F9000 SYSTEM WIRING:
2 DOORS CONTROLLER CONNECTION EXAMPLE
Devices consumption:
- ATLAS = 10 W
- F9000 reader= 1W
- Actuator = 3W
Maximum number of devices
that can be connected to the
RS485 channel = 1 (per
channel).
Power supply unit:
24 VDC - 1,65 A
(35 W)
L 2L 1
P1 P2 LRL
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
LPW
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
DOOR 1
(Actuator cod.5E2501)
12 VAC
DOOR 1
Wirings also applies to Atlas
Standard

AVVERTENZE
Si prega di leggere questo manuale prima di utilizzare il dispositivo per garantire un uso sicuro e corretto.
Conserva questo manuale come riferimento futuro.
L’installazione e la manutenzione di questo dispositivo deve essere effettuata da personale tecnico qualificato, adeguatamente formato da ISEO.
Le istruzioni devono essere attentamente seguite durante l’installazione. Queste istruzioni e qualsiasi altra istruzione di manutenzione deve essere
trasferita dall’installatore all’utilizzatore.
Nessuna modifica di alcun tipo è permessa, ad eccezione di quelle descritte in queste istruzioni.
Il prodotto deve essere destinato esclusivamente all'uso per il quale è espressamente progettato e quindi come controller di server Web per sedi civili
e industriali. Ogni altro uso è considerato improprio e pericoloso.
Il collegamento elettrico deve essere eseguito secondo le leggi vigenti da personale qualificato.
Per tutte le riparazioni contattare esclusivamente i centri di assistenza tecnica autorizzati dal costruttore.
Scollegare l'alimentazione prima di eseguire qualsiasi servizio tecnico che comporti l'apertura o l'accesso alle parti interne del prodotto.
Smaltire il prodotto separatamente dai rifiuti domestici, in conformità con le leggi e i regolamenti locali.
Garantire la ricarica completa della batteria interna dell’Atlas eseguendo un ciclo di ricarica completo (24 ore), minimo ogni 6 mesi.
Il calcolo della sezione dei cavi deve essere effettuato da personale qualificato.
La massima lunghezza del cavo del canale LOCKBUS è 100 mt (somma di tutti i rami).
Il voltaggio consigliato per il canale LOCKBUS è 24 VDC.
In caso di interruzione di corrente la batteria ricaricabile all’interno dell’Atlas garantisce l’alimentazione per massimo 30 minuti.
Per una corretta protezione dell’impianto elettrico, è consigliabile prevedere un interruttore di protezione a monte del trasformatore.
Per assistenza tecnica o riparazioni, contatta esclusivamente Iseo Serrature o un centro tecnico autorizzato Iseo Zero1.
Iseo Zero1 si riserva il diritto, senza preavviso, di apportare tutte le modifiche necessarie al prodotto e al manuale di istruzioni, per miglioramenti di qualità o
necessità di produzione o di marketing.
La connessione a terra dell’Atlas è obbligatoria.
Se l’Atlas Master è collegato ad Altas Slave, Attuatori e Lettori, collocati in aree esterne all’edificio principale (zone non equipotenziali), aggiungere alla rete
elettrica, a monte dell'Atlas Master, dei Dispositivi di Protezione da Sovratensioni (Surge Protection Devices - SPD). Questo in ottemperanza alla Valutazione del
Rischio di Protezione contro i Fulmini del tuo edificio secondo le legislazioni vigenti.
https://www.iseo.com/it/it/download
Atlas Plus
INSTALLATION GUIDE (IT)
ELECTRONIC SUPPORT SERVICE
iseozero1.com
®
i s e o .co m
Iseo Serrature s.p.a
Via San Girolamo 13
25055 Pisogne (BS)
ITALIA
Tel. +39 0364 8821
Non contractual document. Subjecet to change. Cod. 6000005E00013.1 - 07/09/2020
Atlas PLUS Installation Guide (IT) - © 2020 Iseo Serrature S.p.a. - www.iseo.com
Cod.5E002012
ATTENTION
NiMH 7,2V 1500mA
NiMH battery pack
7,2 V - 1500 mAh
Pericolo d’esplosione sela batteriaèsostituita con altra di tipo errato. Smaltire le batterie esauritein basealle leggi e alle norme ambientali locali.

2. ATLAS VISTA GENERALE
ATLAS
R
G
TX RX
CH
0
TX RX
CH
1
TX RX
CH
2
ATLA S
S1S3
J7
J17
J14
J4J5J11J6
LATO ANTERIORE LATO POSTERIORE
S1
Pulsante
reset
Porta
Ethernet
Porte
USB
Alimentazione
Canale
Lockbus
CH0
Canale CH2
RS485
S3
Pulsante
spegnimento
Interfaccia seriale
(porta debug)
LED
canali TX/RX
LED
attività
ethernet
LED rosso
(avvio e
spegnimento)
LED verde
(avvio)
LED
funzionamento
batteria
LED
alimentazione
S2
Pulsante
Wake-up
Connettersi a 192.168.0.184 da browser Internet
Google Chrome, Microsoft Edge o Apple Safari.
Canale CH1
RS485
1. CARATTERISTICHE TECNICHE
Interfacce di comunicazione:
- 1 interfaccia Ethernet TCP/IP 10/100 base T
- 1 canale LOCKBUS (CH0) per connettere lettori Stylos online e Attuatori (max
8 lettori e 8 lettori).
- 2 canali RS485 (CH1/CH2) per connettere i lettori F9000 online (max 1 per
canale)
- 2 USB 2.0 Tipo A
- 1 interfaccia seriale (debug)
Alimentazione:
- 12÷24 Vdc
- Potenza massima assorbita 10W (senza dispositivi collegati).
Batteria di backup interna:
- Pacco batterie 1500mAh (7,2Vdc) NiMH
- Tempo di backup stimato: 30 minuti
CPU e memoria:
- Modulo CPU ARM 9
- Orologio 800MHz CPU
- Flash memory 512MB
- 64MB SDRAM
- 8GB Micro-SD
Sistema operativo:
- Linux
Pulsanti:
- S1 Reset (per effettuare manualmente il reboot dell’Atlas)
- S2 Wake-up (per accendere manualmente l’Atlas quando è spento)
- S3 Switch off (per spegnere manualmente l’Atlas)
Scatola:
- Scatola per appoggio a banco (colore nero)
- L x L x A = 167 x 110 x 53 mm
Caratteristiche ambientali:
- Temperatura di operatività: 0°C ÷ +50°C
- Temperatura di stoccaggio: -25°C ÷ +75°C
Certificazioni di conformità:
- 2014/53/EU RED
- RoHS (apparecchiature elettriche ed elettroniche).
- Standard di riferimento: EN301 489-1, EN301 489-17, EN330 440,
EN60950-1, EN62209-2.
- Per dettagli consulta le Dichiarazioni di Conformità disponibili sul sito web
iseo.com (area download).
Contenuto della confezione:
- 1 Atlas Plus server per dispositivi RFID e F9000 ON-LINE e OFF-LINE, con i
connettori.
- Alimentatore 230Vac/24 Vdc - 1,65A (35W)
- Guida Installazione.

3.
ATLAS
S1S3
J7
J17
J14
J4J5J11J6
LATO POSTERIORE
Consumi dispositivi:
- ATLAS = 10 W
- Stylos = 3W
- Attuatore = 3W
Configurazione suggerita per la gestione
di 2 porte: max 4 lettori Stylos.
12 VAC
S1
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PORTA 2
PORTA 2
(Attuatore
cod.5E2501)
PORTA 2
(Stylos cod.5E1310126)
12 VAC
S1
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PORTA 1
PORTA 1
(Attuatore
cod.5E2501)
PORTA 1
(Stylos cod.5E1310126)
Unitàdi alimentazione:
24 VDC - 1,65 A(35 W)
CABLAGGIO SISTEMA V364 RFID:
ESEMPIO DI CONNESSIONE PER LA GESTIONE DI 2 PORTE
Vistaretroscheda
elettronica
Lunghezza totale dei cavi collegati al canale LOCKBUS
(somma di tutti i rami): MAX 100 mt.
Capacità conduttore < 100 pF/m.
Resistenza elettrica del conduttoremax 90 ohm/Km.
Cavo allarme 3 x 0,75mm - AWG 18 NON schermato (il
calcolo della sezione dei cavi deve essere verificato da
personale qualificato).
SPECIFICHE CABLAGGI
LOCKBUS
(+) V ALIM
( ) GND
2
I colori dei cablaggi riportati negli schemi elettrici sono solo
un esempio.
Per la configurazione degli indirizzi
dello Stylos, consultare la Guida
Installazione Stylos al sito: iseo.com.
I cablaggi si applicano anche all’Atlas
Standard
Vista retro scheda
elettronica
NON
schermato

SPECIFICHE CABLAGGI
S1S3
J7
J17
J14
J4J5J11J6
LATO POSTERIORE
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PORTA 2
(Attuatore cod.5E2501)
12 VAC
PORTA 2
PORTA 2
(Lettore F9000
cod.E032**)
PORTA 1
(Lettore F9000
cod.E032**)
4.
Consumi dispositivi:
- ATLAS = 10 W
- Lettore F9000 = 1W
- Attuatore = 3W
Numero massimo di dispositivi
collegabili ai canali RS485 = 1
(per canale).
Unità di
alimentazione:
24 VDC - 1,65 A
(35 W)
CABLAGGIO SISTEMA V364 F9000:
ESEMPIO DI CONNESSIONE PER LA GESTIONE DI 2 PORTE
SER.A/B
SER.A/B
+ V Power
GND
Schermo
Massima lunghezza del cavo Ethernet tra Atlas e Lettore F9000: 500 mt.
Cavo Ethernet FTP AWG24 CAT5E (o superiore).
Collegare una resistenza da 120 ohm (1/4 W), sia lato Atlas che lato Lettore
F9000, come mostrato nello schema.
Capacità conduttore < 100 pF/m.
Resistenza elettrica del conduttore max 90 ohm/Km.
I colori dei cablaggi riportati negli schemi elettrici sono solo un esempio.
L 2L 1
P1 P2 LRL
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
LPW
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PORTA 1
(Attuatore cod.5E2501)
12 VAC
PORTA 1
I cablaggi si applicano anche
all’Atlas Standard

HINWEISE
https://www.iseo.com/it/de/download
Lesen Sie diese Anleitung vor Benutzung des Gerätes, um den sachgemäßen Umgang zu gewährleisten.
Bewahren Sie diese Anleitung als künftige Referenz auf.
Die Installation und Wartung des Geräts muss durch qualifiziertes, von ISEO entsprechend geschultes technisches Personal erfolgen.
Folgen sie bei der Installation sorgfältig der Anleitung. Anleitung und ggf. Wartungsanweisungen sollten vom Installateur an den Nutzer weitergegeben
werden.
Änderungen jeglicher Art, außer der in deiser Anleitung beschriebener, sind nicht erlaubt.
Das Produkt darf nur zu dem Zweck verwendet werden, für den es konzipiert wurde, anderweitiger Gebrauch gilt als unsachgemäß und ist gefährlich.
Die elektrischen Anschlüsse sind entsprechend den Anweisungen in dieser Anleitung vorzunehmen und müssen den geltenden Vorschriften entsprechen.
Wenden Sie sich für alle Reparaturen ausschließlich an einen vom Hersteller autorisierten technischen Fachhändler.
Unterbrechen Sie die Stromzufuhr, bevor Sie technische Services durchführen, der das Öffnen oder den Zugang zu den inneren Teilen des Produkts beinhaltet.
Entsorgen Sie das Produkt getrennt vom Hausmüll, in Übereinstimmung mit den örtlichen Gesetzen und Vorschriften.
Stellen Sie sicher, dass der interne Akku des Atlas mindestens alle 6 Monate durch einen vollständigen Ladezyklus (24 Stunden) aufgeladen wird.
Die Berechnung des Kabelquerschnitts muss von qualifiziertem Personal durchgeführt werden.
Gesamte LOCKBUS Kanal Kabellänge beträgt 100 Meter (Summe aller Zweige).
Die empfohlene Spannung für den LOCKBUS-Kanal beträgt 24 VDC.
Im Falle eines Stromausfalls gewährleisten der Stützakku im Inneren des Atlas die Stromversorgung für maximal 30 Minuten.
Es ist ratsam, für eine entsprechende Trennung, einen Schutzschalter vor der Spannungsversorgung zu verbauen.
Für technische Unterstützung oder Reparaturen wenden Sie sich nur an Iseo Serrature oder an einen von Iseo Zero1 autorisierten Fachhändler.
Iseo Zero1 behält sich das Recht vor, ohne Vorankündigung alle notwendigen Änderungen am Produkt und an der Installationsanleitung vorzunehmen,
um Qualitätsverbesserungen oder Herstellungs- oder Marketinganforderungen zu erfüllen.
Eine Atlas-Erdungsverbindung ist unbedingt erforderlich.
Verwenden Sie vor dem Atlas Master Überspannungsschutzgeräte (SPD), wenn dieser mit Atlas Slaves, Aktuatoren und Lesern verbunden wird, die im
Außenbereich (mit Potentialdifferenz) platziert sind, entsprechend der Blitzschutz-Risikobewertung Ihres Gebäudes und der aktuellen Gesetzgebung.
Es besteht Explosionsgefahr, wenn die Batterie mit einem falschen Typersetzt wird. Entsorgen Sie verbrauchte Batterien umgehend und im Einklang mit den
örtlichen Umweltgesetzen und Richtlinien.
AUFMERKSAMKEIT
NiMH 7,2V 1500mA
NiMH battery pack
7,2 V - 1500 mAh
Atlas Plus
INSTALLATIONSANLEITUNG (DE)
ELECTRONIC SUPPORT SERVICE
iseozero1.com
®
i s e o .co m
Iseo Serrature s.p.a
Via San Girolamo 13
25055 Pisogne (BS)
ITALIA
Tel. +39 0364 8821
Kein rechtsverbindliches Dokument. Änderungen und Irrtümer vorbehalten. Cod. 6000005E00013.1 - 07/09/2020
Atlas PLUS Installationsanleitung (DE) - © 2020 Iseo Serrature S.p.a. - www.iseo.com
Cod.5E002012

1. TECHNISCHE DATEN
Kommunikationsschnittstellen:
- 1 Ethernet Schnittstelle TCP/IP 10/100 base T
- 1 LOCKBUS Kanal (CH0) zum Anschluss von Stylos Online Lesern und
Aktuatoren (max. 8 Lesern und 8 Atktuatoren).
- 2 RS485 Kanäle (CH1/CH2) zum Anschluss von F9000 Online Lesern (max 1
pro Kanal)
- 1 USB 2.0 Typ A
- 1 Serielle Schnittstelle (debug)
Spannungsversorgung:
- 12 bis 24 V DC
- Maximaler Verbrauch 10 W (wenn keine weiteren Geräte angeschlossen sind)
Interne Stützbatterie:
- 1500mAh (7,2Vdc) NiMH Batterie
- Geschätzte Überbrückungszeit: 30 Minuten
CPU and Speicher:
- ARM 9 basierendes CPU Modul
- 800MHz CPU Takt
- 512MB Flash Speicher
- 64MB SDRAM
- 8GB Micro-SD
Betriebssystem:
- Linux
Funktionstasten:
- S1 Neustart (zum manuellen neu starten des Atlas)
- S2 Einschalten (zum manuellen Einschalten des Atlas)
- S3 Ausschalten (zum manuellen Einschalten des Atlas)
Gehäuse:
- Tischgehäuse (schwarz)
- L x B x H = 167 x 53 x 110 mm
Umweltbedingungen:
- Betriebstemperatur: 0 °C ÷ +50 °C;
- Lagertemperatur: -25 °C ÷ +75 °C.
Konformitätserklärungen:
- 2014/53/EU RED
- RoHS (elektrische und elektronische Geräte).
- Normen: EN301 489-1, EN301 489-17, EN330 440, EN60950-1,
EN62209-2.
- Weitere Details zu Konformitätserklärungen sind unter www.iseo.com
verfügbar.
Verpackungsinhalt:
- 1 Atlas Plus Controller für RFID und F9000 ONLINE und OFFLINE Geräte, inkl.
Steckverbindern.
- 1 Netzteil 230Vac/24Vdc - 1,65A (35W).
- Installationsanleitung.
2. ÜBERSICHT Verbinden zu 192.168.0.184 mit Google Chrome,
Microsoft Edge oder Apple Safari Internet Browser.
ATLAS
R
G
TX RX
CH
0
TX RX
CH
1
TX RX
CH
2
ATLAS
S1S3
J7
J17
J14
J4J5J11J6
VORDERSEITET RÜCKSEITE
S1
Neustart
Ethernet
USB
Netzteil
Lockbus
Kanal
CH0
RS485
Kanal
CH1
RS485
Kanal
CH2
S3
Ausschalten
Serielle
Schnittstelle
(debug)
TX/RX
Kanäle LED
Ethernet
LED
Rot LED
(starten und
ausschalten)
Grün LED
(starten)
Batterie
LED
Netzteil
LED
S2
Einschalten

3.
ATLAS
S1S3
J7
J17
J14
J4J5J11J6
RÜCKSEITE
Geräte-Verbrauch:
- ATLAS = 10 W
- Stylos = 3W
- Aktuator= 3W
12 VAC
S1
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
TÜR 2
TÜR 2
(Aktuator
cod.5E2501)
TÜR 2
(Stylos cod.5E1310126)
12 VAC
S1
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
TÜR 1
TÜR 1
(Aktuator
cod.5E2501)
TÜR 1
(Stylos cod.5E1310126)
Spannungsversorgung:
24 VDC - 1,65 A(35 W)
V364 RFID SYSTEM VERKABELUNG:
2 TÜREN VERSCHALTUNGSBEISPIEL
Die Stylos-Adresskonfiguration finden
Sie im Stylos-Installationshandbuch,
verfügbar unter: iseo.com.
Die Verkabelung gilt auch für Atlas
Standard
Empfohlene Konfiguration für 2 Türen
Controller: max. 4 Stylos Leser.
Gesamte LOCKBUS Kanal Kabellänge (Summe aller Zweige):
Maximal 100 Meter
Leitungskapazität < 100pF/m.
Elektrischer Leitungswiderstand max. 90 Ohm/Km.
Kabel 3 x 0,75mm - AWG 18 UNGESCHIRMT (die
Berechnung des Kabel querschnitts muss durch
qualifziertes Personal erfolgen).
KABEL-SPEZIFIKATIONEN
LOCKBUS
(+) V ALIM
( ) GND
2
In Schaltplänen dargestellte Farben der Drähte sind nur ein Beispiel.
Rückansicht
Leiterplatte
Rückansicht
Leiterplatte
UNGES-
CHIRMT

KABEL-SPEZIFIKATIONEN
S1S3
J7
J17
J14
J4J5J11J6
RÜCKSEITE
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
TÜR 2
(Aktuatorcod.5E2501)
12 VAC
TÜR 2
TÜR 2
(F9000 Leser
cod.E032**)
TÜR 1
(F9000 Leser
cod.E032**)
4.
Geräte-Verbrauch:
- ATLAS = 10 W
- F9000 Leser = 1W
- Aktuator = 3W
Spannungsversorgung:
24 VDC - 1,65 A
(35 W)
V364 F9000 SYSTEM VERKABELUNG:
2 TÜREN VERSCHALTUNGSBEISPIEL
SER.A/B
SER.A/B
+ V Power
GND
Schirm
Maximale Netzwerkkabel-Länge zwischen Atlas and F9000 Leser: 500 Meter.
Netzwerkkabel FTP AWG24 CAT5E (und höher).
Verwenden Sie 120 Ohm (1/4W) Widerstände am Atlas und F9000 Leser,
wie im Schema dargestellt.
Leitungskapazität < 100pF/m.
Elektrischer Leitungswiderstand max. 90 Ohm/Km.
In Schaltplänen dargestellte Farben der Drähte sind nur ein Beispiel.
L 2L 1
P1 P2 LRL
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
LPW
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
TÜR 1
(Aktuator cod.5E2501)
12 VAC
TÜR 1
Die Verkabelung gilt auch für
Atlas Standard
Maximale Anzahl von Geräten,
die an den RS485-Kanal anges-
chlossen werden können = 1
(pro Kanal).

Risque d'explosion si la batterie est remplacée par un type incorrect. Eliminez les batteries usagées conformément aux règles et lois environnementales locales
en vigueur.
NiMH 7,2V 1500mA
NiMH battery pack
7,2 V - 1500 mAh
AVERTISSEMENTS
https://www.iseo.com/it/fr/download
Lire ce manuel avant d'utiliser l'appareil afin d’en garantir une utilisation sûre et appropriée.
Conserver ce manuel comme référence pour la prochaine fois.
L'installation et la maintenance de l'appareil doivent être effectuées par un personnel technique qualifié, formé de manière spécifique par l'ISEO.
Les instructions doivent être soigneusement suivies lors de l'installation. Ces instructions et toute instruction d'entretien doivent être transmises
par l'installateur à l'utilisateur.
Aucune modification de quelque nature que ce soit n'est autorisée, à l'exception de celles décrites dans les présentes instructions.
Le produit doit être destiné uniquement à l'usage pour lequel il est conçu et donc comme contrôleur de serveur web pour des sites publics et industriels.
Toute autre utilisation est considérée comme inappropriée et dangereuse.
Le raccordement électrique doit être effectué conformément aux instructions du constructeur et dans le respect de la réglementation en vigueur.
Pour toute réparation, adressez-vous exclusivement à un centre d'assistance technique agréé par le constructeur.
Débrancher l'alimentation électrique avant d'effectuer une maintenance technique qui implique l'ouverture ou l'accès aux parties internes du produit.
Jeter le produit séparément des déchets ménagers, conformément aux lois et règlements locaux.
Assurer la recharge complète de la batterie interne de l'Atlas en effectuant un cycle de recharge complet (24 heures), au minimum tous les 6 mois.
Le calcul de la longueur des câbles doit être effectué par un personnel qualifié.
La longueur maximale du câble du circuit LOCKBUS est de 100 mt
(somme de tous les câbles)
.
La tension recommandée pour le circuit LOCKBUS est de 24 VDC.
En cas de panne de courant, la batterie rechargeable à l'intérieur de l'Atlas assure une alimentation électrique pendant 30 minutes maximum.
Il est conseillé de prévoir un disjoncteur approprié, un interrupteur de sécurité en amont du transformateur.
Pour toute assistance technique ou réparation, contacter uniquement Iseo Serrature ou un technicien agréé Iseo Zero1 .
Iseo Zero1 se réserve le droit, sans préavis, d'apporter toutes les modifications nécessaires au produit et au manuel d'instructions, pour des
améliorations de la qualité ou des besoins de fabrication ou de commercialisation.
La connexion à la terre de l'Atlas est obligatoire.
Ajoutez des dispositifs de sécurité contre les surtensions (SPD) au réseau, en amont de l'Atlas Master, lorsqu'il est connecté à des Atlas Esclaves,
des activateurs et des lecteurs placés dans des zones extérieures au bâtiment (zones non équipées), selon l'évaluation des risques
de protection contre la foudre de votre bâtiment et les législations en vigueur.
ATTENTION
Atlas Plus
GUIDE D’INSTALLATION (FR)
ELECTRONIC SUPPORT SERVICE
iseozero1.com
®
i s e o .co m
Iseo Serrature s.p.a
Via San Girolamo 13
25055 Pisogne (BS)
ITALIA
Tel. +39 0364 8821
Document non contractuel. Sous réserve de modification. Cod. 6000005E00013.1 - 07/09/2020
Atlas PLUS Guide d’Installation Guide (FR) - © 2020 Iseo Serrature S.p.a. - www.iseo.com
Cod.5E002012

1. CARACTÉRISTIQUES TECHNIQUES
Interfaces de communication :
- 1 Interface Ethernet TCP/IP 10/100 base T
- 1 entrée LOCKBUS (CH0) pour connecter lecteurs Stylos et Activateur (max
8 lecteurs et 8 Activateur)
- 2 entrées RS485 (CH1/CH2) pour connecter le lecteur F9000 en ligne (max
1 par canal)
- 1 USB 2.0 Type A
- 1 interface série (débogage)
Alimentation électrique :
- 12 -24 V D
- Consommation électrique maximale de 10W (sans appareil connecté)
Batterie de secours interne :
- Batterie NiMH 1500mAh (7,2Vdc)
- Autonomie estimée : 30 min sans alimentation
CPU et mémoire :
- Module CPU basé sur ARM 9
- Horloge CPU 800MHz
- 512 Mo de mémoire Flash
- 64MB SDRAM
- Micro-SD 8GB
Système d’exploitation :
- Linux (Kernel 2.6.28)
Boutons de commande :
- Reset (pour redémarrer manuellement l’Atlas)
- Wake-up (pour redémarrer manuellement l’Atlas lorsqu’il est éteint)
- Switch-OFF (pour éteindre manuellement l’Atlas)
Boîtier :
- Boîtier d’installation (couleur noire)
- L x Lg x H = 167 x 110 x 53 mm
Caractéristiques environnementales :
- Température de fonctionnement : 0°C ÷ +50°C
- Température de stockage : -25°C ÷ +75°C
Certificats de conformité :
- 2014/53/EU RED
- RoHS (electrical and electronic equipment).
- Références standards : EN301 489-1, EN301 489-17, EN330 440,
EN60950-1, EN62209-2.
- Pour plus de détails, voir les certificats de conformité disponible sur le site
iseo.com (dans téléchargement).
Contenu de l’emballage :
- 1 serveur Atlas Plus pour les appareils RFID, F9000 ON-LINE et OFF-LINE,
avec connecteurs.
- Alimentation électrique
- Guide d’Installation.
2. ATLAS VUE GÉNÉRALE
ATLAS
R
G
TX RX
CH
0
TX RX
CH
1
TX RX
CH
2
ATLA S
S1S3
J7
J17
J14
J4J5J11J6
FACE AVANT CÔTÉ ARRIÈRE
S1
Reset
Ethernet
USB
Alimentation
Canal
Lockbus
CH0
Canal CH2
RS485
S3
Switch off
Interface série
(débogage)
LED
canal TX/RX
LED
ethernet
LED Rouge
(démarrage et
arrêt)
LED vert
(démarrage)
LED
batterie
LED
alimentation
S2
Wake-up
Canal CH1
RS485
Connectez-vous au 192.168.0.184 depuis
Google Chrome, Microsoft Edge ou Apple Safari.

3.
ATLAS
S1S3
J7
J17
J14
J4J5J11J6
CÔTÉ ARRIÈRE
Consommation des appareils :
- ATLAS = 10 W
- Stylos = 3W
- Activateur = 3W
12 VAC
S1
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PORTE 2
PORTE 2
(Activateur
cod.5E2501)
PORTE 2
(Stylos cod.5E1310126)
12 VAC
S1
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PORTE 1
PORTE 1
(Activateur
cod.5E2501)
PORTE 1
(Stylos cod.5E1310126)
Alimentation électrique :
24 VDC - 1,65 A(35 W)
Capacité des câbles < 100pF/m.
Résistance électrique des câbles max 90 ohm/Km.
SPÉCIFICATIONS DE CÂBLAGE
LOCKBUS
(+) V ALIM
( ) GND
Pour la configuration des lecteurs
Stylos consultez le guide d’Installa-
tion, disponible à l’adresse
suivante : iseo.com.
Le câblage s'applique également à la
norme Atlas
CÂBLAGE DU SYSTÈME RFID V364 :
EXEMPLE DE CONNEXION D’UN CONTRÔLEUR POUR 2 PORTES
Configuration conseillée pour le contrôleur
2 portes max 4 lecteurs Stylos.
Vue arrière de la
plaque de câblage
intégrée
Vue arrière de la
plaque de câblage
intégrée
Câble 3 x 0,75mm - AWG 18 NON blindée (le calcul de
la longueur doit être vérifié par du personnel qualifié.
Longueur totale du câble du circuit LOCKBUS (somme
de tous les câbles) : MAX 100mt.
Les couleurs des fils indiquées dans les schémas de
câblage ne sont qu'un exemple.
NON
blindée
2

SPÉCIFICATIONS DE CÂBLAGE
S1S3
J7
J17
J14
J4J5J11J6
CÔTÉ ARRIÈRE
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PORTE 2
(Activateur cod.5E2501)
12 VAC
PORTE 2
PORTE 2
(Lecteur F9000
cod.E032**)
PORTE 1
(Lecteur F9000
cod.E032**)
4.
Consommation des appareils :
- ATLAS = 10 W
- Lecteur F9000 = 1W
- Activateur = 3W
Alimentation
électrique :
24 VDC - 1,65 A
(35 W)
SER.A/B
SER.A/B
+ V Power
GND
Schield
Longueur maximale du câble Ethernet entre l'Atlas et le lecteur F9000 : 500mt.
Câble Ethernet FTP AWG24 CAT5E (et supérieur).
Connecter une batterie de 120 ohms (1/4W), du côté du lecteur Atlas et
F9000, comme indiqué dans le schéma.
Capacité des câbles < 100pF/m.
Résistance électrique des câbles max 90 ohm/Km.
Les couleurs des fils indiquées dans les schémas de câblage ne sont qu'un exemple.
L 2L 1
P1 P2 LRL
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
LPW
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PORTE 1
(Activateur cod.5E2501)
12 VAC
PORTE 1
Le câblage s'applique
également à la norme Atlas
CÂBLAGE DU SYSTÈME V364 F9000 :
EXEMPLE DE CONNEXION D’UN CONTRÔLEUR POUR 2 PORTES
Nombre maximum d'appareils
pouvant être connectés au
circuit RS485 : 1 (par circuit)

Riesgo de explosión si la batería es remplazada por una incorrecta. Deseche la batería usada de acuerdo con las leyes y normas ambientales en vigor.
ATENCIÓN
NiMH 7,2V 1500mA
NiMH battery pack
7,2 V - 1500 mAh
ADVERTENCIAS
Lea este manual antes de utilizar el dispositivo para garantizar un uso seguro y adecuado.
Conserve este manual como referencia futura.
La instalación y el mantenimiento del dispositivo deben ser realizados por personal técnico cualificado y debidamente capacitado por ISEO.
Las instrucciones deben ser cuidadosamente seguidas durante la instalación. El instalador debe facilitar estas instrucciones y las indicaciones de mante-
nimiento al usuario.
No se permiten modificaciones de ningún tipo, excepto las descritas en estas instrucciones.
El producto debe estar destinado únicamente para el uso para el que está expresamente diseñado y, por tanto, como controlador de servidor web para
ubicaciones civiles e industriales. Cualquier otro uso se considera impropio y peligroso.
La conexión eléctrica debe ser realizada de acuerdo con las instrucciones del conductor y respetando la normativa vigente.
Para todas las reparaciones, comuníquese exclusivamente con un centro de asistencia técnica autorizado por el constructor.
Desconecte la fuente de alimentación antes de realizar cualquier servicio técnico que implique abrir o acceder a las partes internas del producto.
Deseche el producto por separado de la basura doméstica, de acuerdo con las leyes y regulaciones en vigor.
Garantire la ricarica completa della batteria interna dell’Atlas eseguendo un ciclo di ricarica completo (24 ore), minimo ogni 6 mesi.
El cálculo de la sección del cableado debe ser realizado por personal cualificado.
La longitud máxima del cable del canal LOCKBUS es de 100m. (suma de todos los tramos).
El voltaje recomendado para el canal LOCKBUS es de 24 VCC.
En caso de fallo de alimentación, la batería recargable interna del Atlas garantiza la alimentación durante un máximo de 30 minutos.
Asegúrese de realizar la carga completa de la batería interna del Atlas, ejecutando un ciclo de recarga completo (24 horas), al menos cada 6 meses.
Para cualquier asistencia o reparaciones, contacte solo a Iseo Serrature o un centro técnico autorizado Iseo Zero1.
Iseo Zero1 se reserva el derecho, sin previo aviso, de realizar todas las modificaciones necesarias al producto y al manual de instrucciones, para mejoras de
calidad, necesidades de fabricación o comercialización.
La conexión a tierra del Atlas es obligatoria.
Añada dispositivos de protección contra sobretensiones (SPD) a la red eléctrica, antes del Atlas Master, cuando esté conectado a Atlas Slaves, Actuadores y
Lectores ubicados en áreas externas del edificio (zonas no equipotenciales), de acuerdo con la Evaluación de riesgos de protección contra rayos de su edificio y
las legislaciones vigentes.
https://www.iseo.com/it/es/download
Atlas Plus
GUÍA DE INSTALACIÓN (ES)
ELECTRONIC SUPPORT SERVICE
iseozero1.com
®
i s e o .co m
Iseo Serrature s.p.a
Via San Girolamo 13
25055 Pisogne (BS)
ITALIA
Tel. +39 0364 8821
Documento no contractual. Sujeto a cambios. Cod. 6000005E00013.1 - 07/09/2020
Atlas DIN Guía de Instalación (ES) - © 2020 Iseo Serrature S.p.a. - www.iseo.com
Cod.5E002012

1. CARACTERÍSTICAS TÉCNICAS
Interfaces de comunicación:
-
1 interfaz Ethernet TCP/IP 10/100 base T
- 1 canal LOCKBUS (CH0) para conectar online lectores Stylos y Actuadores
(máx. 8 lectores y 8 actuadores).
- 2 canales RS485 (CH1/CH2) para conectar online lectores F9000 (máx. 1
por canal)
- 1 USB 2.0 Tipo A
- 1 interfaz en serie (debug)
Fuente de alimentación:
- 12÷24 Vcc
- Consumo máximo 10W (sin dispositivos conectados)
Batería interna de respaldo:
- Paquete de baterías NiMH 1500mAh (7,2Vcc)
- Tiempo estimado de respaldo: 30 minutos
CPU y memoria:
- Módulo de CPU basado en ARM 9
- Reloj CPU 800MHz
- 512MB de memoria Flash
- 64MB de SDRAM
- 8GB Micro-SD
Sistema operativo:
- Linux
Botones:
- S1 Reset (para reiniciar manualmente el Atlas)
- S2 Wake-up (para iniciar manualmente el Atlas cuando está apagado)
- S3 Switch off (para apagar manualmente el Atlas)
Housing:
- Carcasa (color blanco)
- L x W x H = 167 x 110 x 53 mm
Características ambientales:
- Temperatura de funcionamiento: 0°C ÷ +50°C
- Temperatura de almacenamiento: -25°C ÷ +75°C
Certificados de conformidad:
- 2014/53/EU RED
- RoHS (equipos eléctricos y electrónicos).
- Normativa de referencia: EN301 489-1, EN301 489-17, EN330 440,
EN60950-1, EN62209-2.
- Para más detalles vea la Declaración de conformidad disponible en el sitio
web iseo.com (área de descarga).
Contenido del paquete:
- 1 servidor Atlas Plus DIN para dispositivos RFID y F9000 ON-LINE y
OFF-LINE, con conectores.
- 1 fuente de alimentación 230Vca/24Vcc - 1,65A (35W)
- Guía de instalación.
2. DESCRIPCIÓN DEL ATLAS
ATLAS
R
G
TX RX
CH
0
TX RX
CH
1
TX RX
CH
2
ATLA S
S1S3
J7
J17
J14
J4J5J11J6
LADO DELANTERO LADO TRASERO
S1
Botón
Reiniciar
Puerto
Ethernet
Puertos
USB
Fuente de
alimentación
CH2 Canal
RS485
S3
Botón
Apagar
Interfaz serie
(puerto debug)
LED
de canales
TX/RX
LED
de actividad
Ethernet
LED Rojo
(iniciar y
apagar)
LED verde
(iniciar)
LED
Batería en
funcionamiento
LED
Alimentación
S2
Botón
Wake-up
Conéctese a 192.168.0.184 desde los navegadores
Google Chrome, Microsoft Edge o Apple Safari.
CH1 Canal
RS485
CH0 Canal
Lockbus

3.
ATLAS
S1S3
J7
J17
J14
J4J5J11J6
LADO POSTERIOR
Configuración sugerida para el controlador
de 2 puertas: máx. 4 lectores Stylos.
Cableado aplicable también al Atlas
Standard
Consumo de dispositivos:
- ATLAS = 10 W
- Stylos = 3W
- Actuador = 3W
12 VAC
S1
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PUERTA 2
PUERTA 2
(Actuador
cod.5E2501)
PUERTA 2
(Stylos cod.5E1310126)
12 VAC
S1
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PUERTA 1
PUERTA 1
(Actuador
cod.5E2501)
PUERTA 1
(Stylos cod.5E1310126)
Fuente de alimentación:
24 VDC - 1,65 A(35 W)
CABLEADO DEL SISTEMA V364 RFID:
EJEMPLO DE CONEXIÓN DEL CONTROLADOR DE PUERTAS
Para la configuración de la dirección del
Stylos, consulte la Guía de instalación
de Stylos, disponible en: iseo.com.
Vista posterior
del circuito
Vista posterior
del circuito
Longitud total del cable del canal LOCKBUS (suma de
todos los tramos): MÁX. 100m.
Capacitancia del conductor < 100pF/m.
Resistencia eléctrica del conductor máx. 90 ohm/Km.
Cable 3 x 0,75mm - AWG 18 NO blindado (el cálculo
de la sección de cables debe ser verificado por personal
cualificado).
ESPECIFICACIONES DEL CABLEADO
LOCKBUS
(+) V ALIM
( ) GND
2
Los colores de los cables reportados en los diagramas de
cableado son solo un ejemplo.
NO
blindado

ESPECIFICACIONES DEL CABLEADO
S1S3
J7
J17
J14
J4J5J11J6
LADO POSTERIOR
L 2L 1
P1 P2 L R L
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
L P W
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PUERTA 2
(Actuatorcod.5E2501)
12 VAC
PUERTA 2
PUERTA 2
(LectorF9000
cod.E032**)
PUERTA 1
(Lector F9000
cod.E032**)
4.
Consumo de dispositivos::
- ATLAS = 10 W
- Lector F9000 = 1W
- Actuator = 3W
Unidad de fuente de
alimentación:
24 VDC - 1,65 A
(35 W)
SER.A/B
SER.A/B
+ V Power
GND
Pantalla
Longitud máxima del cable Ethernet entre Atlas y lector F9000: 500m.
Cable Ethernet FTP AWG24 CAT5E (y superior).
Conecte una resistencia de 120 ohm (1/4W), en ambos lados, Atlas y lector
F9000, como se muestra en el esquema.
Capacitancia del conductor < 100pF/m.
Resistencia eléctrica del conductor máx. 90 ohm/Km.
Los colores de los cables reportados en los diagramas de cableado son solo un ejemplo.
L 2L 1
P1 P2 LRL
V2 Output
V1 Output
LOCKBUS
V PWR +
GND
EARTH
COM
NO/NC
GND
IN AN
I/O 2
I/O 1
VCC
GND
J P 3
LPW
J P 2L C HJ P 1
LV O
Power supply
8
÷
30VDC 0.5A
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
PUERTA 1
(Actuator cod.5E2501)
12 VAC
PUERTA 1
Cableado aplicable también al
Atlas Standard
CABLEADO DEL SISTEMA V364 F9000:
EJEMPLO DE CONEXIÓN DEL CONTROLADOR DE 2 PUERTAS
Número máximo de dispositivos
que pueden ser conectados al
canal RS485 = 1 (por canal).
Other manuals for Zero1 Atlas Plus
2
Table of contents
Languages:
Other Iseo Controllers manuals
Popular Controllers manuals by other brands

Timotion
Timotion TDH6 user manual

BWT
BWT PLATINE DE SPA SP800 installation instructions

Burkert
Burkert 8756 BATCH operating instructions

Honeywell
Honeywell HercuLine 10260A Installation, operation and maintenance manual

KTE
KTE KT-PPC instruction manual

American DJ
American DJ Light Copilot User instructions