ISHTAA ITA SERIES (J) User manual

Scale Users Guide
ISHTAA SCALES INC., INDIA
www.ishtaascales.com
ITA SERIES (J)
Precision Table Top Weighing Balance
ITA Series – Table Top Precision Weighing Balance ITA Series – Table Top Precision Weighing Balance
TM
WARRANTY CERTIFICATE
Customer Name :______________________________________________
_____________________________________________________________
_____________________________________________________________
Phone:_______________________ Mobile:_________________________
Date of Purchase :______________ Invoice / DC No:__________________
Model :______________________ Sl.No : __________________________
Dealers / Agent Name : __________________________________________
______________________________________________________________
______________________________________________________________
The manufacturer warrants all products shipped from India against defects
in MATERIAL and WORKMANSHIP for a period of One (1) year for standard
line of products. All OEM and custom built orders carry (1) year warranty for
MATERIAL and WORKMANSHIP. Warranty will not be applicable for Battery
and adaptors. Normal wear and tear, injury by natural forces, user neglect
and purposeful destruction are NOT covered by this warranty. Technical
Service MUST be performed by authorised staff or factory authorized
personnel. Manufacturer’s obligation is limited to replacement of parts that
have been so returned and are disclosed to Manufacturer’s satisfaction to
be defective. The provisions of these warranty clauses are lieu of all other
warranties, expressed or implied, and of all obligations or liability in
connection with sale of said articles. ISHTAA makes no warranty of
merchantability or fitness for a particular purpose. By accepting the goods,
the buyer acknowledges that the buyer has determined that the goods are
suitable for the buyer’s purposes. In no event shall the Manufacturer be
liable for any subsequential or special damages. Any misuse, improper
installation or tampering shall VOID this warranty.
Product that is malfunctioning within the 1-year warranty period for scale
line and 1-year warranty period for OEM products may be returned to
Manufacturer for Warranty Evaluation at the customers’ expense.
Manufacturer reserves the right to repair OR replace the components free of
charge as may qualify under this warranty.
REMINDER!! WARRANTY DOES NOT COVER USER DAMAGE AND ABUSE. In
addition to a listing of the repairs covered under warranty, if any, the
customer will be billed accordingly for all parts and labour associated with
any NON-WARRANTY repairs made to the product.
14

Content
1. Technical Data ... 1
2. Installation ... 2
3. Controls & Functions ... 3
4. User Operation ... 4
5. Scale Settings ... 8
6. Calibration ... 11
7. Error Codes ... 13
8. Trouble Shooting ... 13
Warranty 14
ITA Series – Table Top Precision Weighing Balance ITA Series – Table Top Precision Weighing Balance
SOLUTIONERROR DISPLAY ERROR
8. ERROR CODES
·Zero not in range
·Weight not enough for
the selected setting
·LOW Battery. Machine
displays message and
turns off
Remove weight from pan
and restart the machine. If
the problem persists, the
machine may have been
overloaded.
Keep weight or Add more
weight on pan for correct
results.
Battery is low. Connect
scale to power so that the
battery can be charged.
REMEDYSYMPTOM POSSIBLE CAUSE
9. TROUBLE SHOOTING
Scale will not
power on
Battery does not
give enough
backup
Weight reading on
scale does not
stabilize
Scale does not
show weight
accurately
External calibration
is not stored after
switch on / off the
machine
If running on batteries, the battery
may have fully discharged. AC Power
cord not connected.
The battery is defective. The battery
may have past its useful life.
Improper calibration.
This happens when the Internal to
External calibration variance larger
than 2%. The cause could be that the
user is not using correct weight.
External Rubbing / Friction. A scale
cannot measure accurately if an object
is rubbing or pressing against the
scale platform. Mobile interference,
Vibration or wind could be other
possible reasons.
Connect scale to
p o w e r s o u r c e .
Recharge battery.
Change the battery.
Move the scale away
from mobile signal,
breeze or vibration
areas.
Calibrate the scale
again to and check
for the proble m
again.
Use correct weights
to calibrate. If the
problem persists,
calibrate the scale
u s i n g i n t e r n a l
13

Other Parameters
Application Modes
Product Features
Keyboard
Display Indicators
**Weighing Units
Calibration
Weight
Pan Size
Front Display Type
Remote Display
Communication
2 seconds
Power
Operating Temp.
Dimensions
* all in one models only. ** specific to country restrictions.
Weighing, Counting, Price / User Calculation
Auto Sleep, 100% Tare Range, Piece Counting, Glow
Control, Direct Printer Output
6 membrane keys (On/off, Counting, F, Mode, Tare and Zero)
Stability, Zero Position, Tare, Charging Status,
Percentage mode, function active, d = e / 10 mode*
g, carat, t**
Digital with external weight.
4kg Approx
120mm dia
0.56" Bright red LED display
Optional, Available with 0.56" LED Display
Optional RS232C for PC communication
2 seconds
9V AC Adaptor / built in battery for backup to 50hrs. / 70 hrs
with sleep mode active
50° to 98° F / 10° to 35° C
164.5 x 232.5 x 164.5 (w x d x h) – including shield.
1. About ITA Series - (J) Precision Balance
We would like to thank you for choosing ISHTAA as your preferred choice for your
weighing requirements.
The ITA series - J weighing scale is an accurate, fast and versatile series of precision
scales, loaded with time saving features and ease of customer use.
The scale is equipped with a 0.56” LED display to show weight for the user, and an
option of remote display for the customer.
There are different models in this series, with capacities ranging from 50g up to 2 kg
and with least count from 1mg up to 20mg.
They all have stainless steel weighing platforms on an special grade ABS pan assembly.
The loadcell is mounted on a special mounting providing precise centering of load and
overload protection of up to 150% FS load capacity.
The soft touch keypad buttons are ideally sized, color coded, and bear symbolic tags
for easy recalling scale functions. The displays are large easy to read LED type displays
for easy view in different lighting conditions.
The scale is loaded with features like, automatic zero tracking, overload alarm, low
battery protection, Special Weighing mode to filter stable results, full capacity tare ,
multiple units of measure, piece counting and price computing function to calculate
gold rate with a press of a button.
The scales feature auto zero tracking to automatically compensate for small
fluctuations in zero such as a build up of material on the platform.
ITA Series – Table Top Precision Weighing Balance ITA Series – Table Top Precision Weighing Balance
2. TECHNICAL DATA
High Precision Balances
ITA-305-J
300g
5mg
300g
±1d
1:60000
ITA-310-J
300g
10mg
300g
±1d
1:30000
ITA-610-J
600g
10mg
600g
±1d
1:60000
ITA-1010-J
1000g
10mg
1000g
±1d
1:100000
Measurement Data
Capacity
Read out / Interval
Tare range Subtractive
Repeatability
Display Resolution
7.3 INTERNAL SERVICE CALIBRATION
Internal calibration also referred as service calibration requires opening
the machine and changing the jumpers. It is advisable to do this step only
if you have required assistance or the service personnel assisting you to
do this.
Open the 4 screws from the bottom of the
machine and 1 from the ABS pan top
change the calibration jumper marked
CAL. Now place back the cover, ABS pan
and the SS pan and switch on the machine.
Make sure there is nothing kept on the
weighing pan. At this moment do not put
back the screws, simply place the cover on
the machine.
To Start Calibration switch ON the scale
and the count down will begin. Wait for a
few seconds until the display shows “CAL”.
Make sure there is no weight on the pan.
Press Zero / Enter key and the display
shows “CAL3PT” this is 3 point calibration,
you can change this setting to 1 point
calibration by pressing the Mode button
and the display will show “CAL1PT”.
Assuming you selected the 3 point
calibration, Press the Zero / Enter button
once and the display shows “0.00” for 2
seconds and then the display will show
“200.00” blinking now place the 200g of
weight on the pan and the display will stop
blinking and after 4 seconds display will
show “400.00” blinking with weight still
on the pan put another 200g of weight to
make the total weight 400g, now again
the display will stop blinking and after 4
seconds display will show “600.00”
blinking, with weight still on the pan place
another 200g 50 make a total of 600g and
the display will stop blinking. Now the
display will show “J-OFF”, lift all the
weight from the pan and change the
calibration jumper, place both the pans
and tighten all the screws and press the
Zero/Enter button once. Check calibration
to ensure the scale is reading correct.
STEP DISPLAY
PROCEDURE
1
2
3
4
12 1

3. INSTALLATION
3.1 Unpacking
Unpack and verify that the following components have been
included:
a) ITA (J) Precision Scale
b) Instruction Manual
c) AC Adapter
d) Draft Shield with cover - mounted on ITA - (J) scale
e) SS Pan on top.
ITA Series – Table Top Precision Weighing Balance ITA Series – Table Top Precision Weighing Balance
Save the packaging material. This packaging ensures the best
possible protection for the storage or transport of the product.
3.2 Placing your scale
3.3 Leveling the scale
3.4 Power Source
Before you install the scale, identify the best location for the
equipment. The proper environment enhances its operation and
longevity. Keep in mind the following factors, which might have a
negative influence on the scale's operation:
a) Vibration: Vibration diminishes the scale's ability to measure
accurately. Electrical machinery such as conveyors and drill
presses can cause inaccurate and non-repeatable readings. The
scale may also read inaccurately if it is not leveled properly. The
scale incorporates a special weighing mode where the scale can
reject readings with vibration up to some extent.
b) Drafts / Air currents: Moving air can cause the scale to read wind
movement as an additional force and cause inconsistency in the
weighing results.
c) External Rubbing / Friction: A scale cannot measure accurately if
an object is rubbing or pressing against the scale platform.
Level the scale by turning the adjustable feet. It is leveled correctly
when the bubble indicator is in the center of the circle.
The unit works on 220V AC Level.
The scale is fitted with a built in 6V 4Ah battery which provides backup
of more than 45 – 70 hours depending on glow setting and sleep
mode setting.
7. CALIBRATION
All ISHTAA weighing scales come pre-calibrated from the factory.
However the scale may require re-calibration. Temperature changes,
geographic gravity variations, altitude changes and abuse are few
reasons why a scale may need recalibration. The scales can be
calibrated using a known external weight.
7.1 CALIBRATION CHECK :
make sure that the scale reads the correct weight on the display. In
case of a variation in the display reading, it is recommended to calibrate
the scale again with the procedure explained below in section 7.2.
7.2. EXTERNAL USER CALIBRATION
To start the calibration switch on
the scale and make sure there is no
weight on the pan and the display
shows “0.000”. Now put a known
weight on the pan for eg. 200g and
the display will show “200.000”
and the display will glow. If the display
does not show the correct weight,
press and hold the ZERO button for 5
seconds till the display will show
“CALIBRATING”. With the weight still
on the pan, the display w i l l n o w
show the weight that is calibrated.
Check calibration to ensure the scale is
reading correct.
Put a known weight on the machine and
211

ITA Series – Table Top Precision Weighing Balance ITA Series – Table Top Precision Weighing Balance
4. CONTROLS & FUNCTIONS
SYMBOL NAME FUNCTION
· To power on and off the machine.
· Switch to piece counting mode .
· Long Press – Initiate the Print Command.
· Auto zero setting - Pre ss, Hold the
Counting bu t t o n and sw i t c h o n t h e
machine.
· Call Price Calculation function.
· Switch to scroll & sleep mode setting- press
Hold the Price button and switch on the scale.
· Long Pre ss – Ent er pri ce of current
gold rate to use for price calculation .
· Switch between weighing units.
· Up Shift to change option of selected digit.
Ex change 0 to 1 to 2 to 3 etc.
· Switch to Internal Count Mode. Hold the
M button and switch on the machine.
· Tare the weight kept on the pan.
· Right, Left shift the selected digits during cal
or other setup modes.
· Manual Accumulation.
· Auto Zero Setting – Press, Hold the Tare
button and switch on the machine.
· Zero the weight kept on the pan.
· Enter Key – Accept the selected setting and
exit from setting mode.
· Press and hold the ZERO button after keeping a
known weight calibrates the scale.
Power Key
Counting /
Print Key
Function /
Left Shift Key
Mode /
Up Shift Key
Tare /
Right Shift Key
Zero /
Enter Key
6.5 RANGE SELECTING : This
function can enable or disable the
dual range setting of your scale
that is you can select the range of
the scale as DOUBLE or SINGLE.
For e.g. If the sale’s Capacity is
600g with Accuracy of 10mg and
the range is selected as Double
then the scale will show the
Accuracy of 5mg upto half the
original capacity. i.e. 300g and
above that it will show the
Accuracy of 10mg upto 600mg.
And if the range is selected as
SINGLE then the scale will show
its original Accuracy i.e., 10mg from 0 to 600g. For selecting a
particular range, Press and Hold the MODE button and switch on the
scale display will show “CAP” press the Zero button 6 times and the
display shows “RANGE” now press the Zero button once and select
between single (SIN) or Double (DBL) range by pressing the Tare button
and then press the Zero button once to accept the range selected.
6.6 DUMMY ZERO SETTING : Press
and hold the Tare button and
switch on the sale. Display shows
“DUMMY 0”. Now press the Zero
button once and the display
shows the pre selected option
i.e., YES or NO, Now you can
select between the YES or NO option by pressing the TARE button and
press the Zero button to make your option accepted.
10 3

5. USER OPERATION
5.1 SWITCHING SCALE - ON / OFF
The scale is switched ON / OFF by pressing
the Power BUTTON: This button is used to
switch on and switch off the scale. It is a real
ON/OF which is implemented using the
latest technology so that there is absolutely no power consumption when the
scale is switched off.
USAGE :
a) SWITCH ON: Press the button once, the scale will switch on.
b) If the scale is already switched on, press the button again,
display will show “SEE YOU SOON” and switch off after
sounding a beep.
Note : Make sure the weighing pan is empty before turning on the scale.
5.
5.2.1 TARE BUTTON This button is
used for taring a weight to
display 0.00. A Tare value is
indicated by the “t” LED on the
panel.
Place a container on the
weighing pan (say 200g), then
press the TARE button. The
weight is tared and the
machine will display zero and
the tare LED will be ON. To
recall the tared weight, simply
press the TARE button again. To
TARE the value, again press the
TARE button.
5.2.2 RIGHT ARROW KEY : This is used to shift selected digit on right side
while entering settable values or calibration weight or any other user
parameter etc.,
2 MANUAL TARE
ITA Series – Table Top Precision Weighing Balance ITA Series – Table Top Precision Weighing Balance
6.3 CAPACITY DISPLAY SETTING :
When the scale is switched on, the
display shows the Capacity and
Accuracy of your scale scrolling,
you can change this setting
through this function that the
Capacity and Accuracy of your
scale should be shown or not at the
time of switching on the scale. Press and Hold the “MODE” button and
switch on the scale, display shows “CAP”. Now press the enter / zero
button and the display shows “YES”. Now select between “YES” or
“NO” option by pressing the TARE button and then press the zero
button 7 times to accept it, if you select “YES” the capacity & accuracy
of the scale will be displayed if “NO” it will not be displayed.
6.4 UNIT MODE DISPLAY SETTING :
This function helps you to access
the two different weighing modes
that is CARAT & TOLA. You can
deactivate any I or both of the
above mode in which you do no
want to weigh and carry on with
gram mode only. Press and Hold
the “MODE” button and switch on the scale display will show “CAP”
now press ZERO button 2 times and the display shows “CARAT”. Press
the Zero button once and select between “YES” or “NO” bu pressing
the TARE button and press the Zero button 3 times to accept it. By
selecting “YES” the weight will be displayed in that particular mode
which you have selected as yes by pressing the mode button while
weighing and if selected as no the weight will not be displayed in that
particular mode.
49

6. SCALE SETTINGS
This menu allows you to do various setting related to scale like auto zero,
scroll mode, dummy zero setting, dual range, auto sleep etc.
6.1 AUTO ZERO SETTING :
Press and hold the COUNTING button
and then switch on the scale. The
display will show “Auto 0” (Valid
Values are 0.0, 0.5, 1.0, 2.0 and 3.0d).
This is the auto zero setting. Press the
ZERO button. You can now select the
value using the TARE (T) button. 3.0d
means 3 divisions. Default setting of
Auto-Zero mode is 3d.
6.2 SCROLL & AUTO SLEEP SETTING
When the scale is switched on and it is
idle, there are 2 types of modes which
we can choose from, i.e., (a) The price
value of gold as set explained in 5.4
should keep scrolling or (b) The scale
should go in auto sleep mode and
only decimal point will be displayed.
Press and hold the price button and
then switch on the scale display shows
“SCROLL”. Press the ZERO button and
the display will show “Yes” or “No”.
You can press the TARE button, and
user can choose whether the scrolling
function is required or not. If the price
scrolling function is required user
should select “Yes”, and if it is not
required then the user should select
“No”. Press the ZERO button, and the display will show “AUTO” which is
the auto sleep function. Now press the zero button and the display will
show “YES” or “NO” you can toggle between both the options by pressing
the “TARE” button. After selecting one option press the “ZERO” button to
accept the entry & exit this setting.
ITA Series – Table Top Precision Weighing Balance ITA Series – Table Top Precision Weighing Balance
5.2.3 MANUAL ACCUMULATION : Keep
a weight on the weighing pan(ex
200g). The display will show the
weight. Now press TARE. The
display will show 0.00. Now
keep another weight (ex 100g),
the display will show its weight.
Now press TARE button. The
display will show the total of the
first value tared and the second
weight tared. Press TARE button
again, the display will show 0.00.
Now keep another weight, the
display will show the weight.
Press TARE button, the display will show the total of all the three
weights (300.00g), press TARE button, the display will show 0.00.
5.3 ZERO OPERATION
Center of Zero is indicated by the
annunciator . You can press
the ZERO/ENTER key to set the
zero point from which all other
weighing and counting is
measured. The zero will function
within 5% of the internal zero setting. The scale has an automatic auto-
zeroing function to account for minor drifting or accumulation of material
on the platform. This auto-zero range can be configured in the user setup.
However you may need to press the ZERO/ENTER key to rezero the scale if
small amounts of weight are shown when the platform is empty.
85

5.4 PRICE BUTTON
Price Button : This button is
used to enter and calculate the
total price of the material being
weighed according to the price
entered. This button is also used
to change the settings for rate
scrolling and sleep mode
function..
5.4.1 PRICE ENTRY :
Press and hold the Price button
for 3 seconds. The display will
show the pre-entered value for
eg. “77213” with all the digits
blinking. You can change the
value by pressing the price,
Counting, Mode, Tare & Zero
button one at a time. Assuming
you entered the new value as
“10000” Once the new price
value is entered press and hold
ITA Series – Table Top Precision Weighing Balance ITA Series – Table Top Precision Weighing Balance
5.5 MODE BUTTON /
UP ARROW KEY :
This button is used to select the
different units of weight available
in the scale, that is to choose
between the units of carat, tola,
and gram.
5.6 COUNTING BUTTON / PRINT
BUTTON :
This button is used to put the scale in the counting mode and also for
the printing the weight data on the printer using the RS232serial
output of the scale (optional).
5.6.1 COUNTING FUNCTION : When
the scale is displaying 0.00, press
this button, the display will show
“P 10” which is the number of
pieces. You can select between
values of 10, 20, 50 and 100 using
the mode button. Once the
number of pieces is displayed,
keep the same number of pieces
on the weighing pan and press the
ZERO button and hold it for 2
seconds. The weight of the pieces
kept on the weighing pan is
displayed as the number of pieces
selected. Simply press the counting button once, if the user wants to
exit the counting function to come in to the weighing mode.
5.6.2 PRINT FUNCTION : When a certain weight value or counting value or
percentage value is being displayed, keep this button pressed for three
seconds. The display will now show “PRINT”. Press ZERO button, the
display will show “DONE” and go back to the working mode.
the Price button for 3 seconds to
accept the entry and the scale
will come back in the weighing mode. Now put a weight say 100g on
the pan and press Price button once. The price value of the kept weight
will be calculated that is “100000” assuming the above said rate of
“10000” and will be displayed with blink 3 times.
5.4.2 LEFT ARROW KEY : This is used while entering settable values
or calibration weight etc.
67
Table of contents