IT Concepts iRis DVR X User manual

1
Operation Manual
iRis
X
iRis
Videoendoskop
iRis
X
The innovative Videoscope
U
D
R
L
EG Konformitätserklärung
EC Declaration of Confi rmity
iRis DVR
5
Electromagnetic compatibility directive
2004/108/EC with reference to the
harmonized standards EN61326-1 (2006)
Emission and Immunity.
Elektromagnetische Verträglichkeit Richt-
linie 2004/108/EG unter Bezugnahme der
harmonisierten Norm EN61326-1 (2006)
Emission- und Störfestigkeit.
Lahnau, 31. Januar 2011
Frank Schlagenhauf
Manager Product Development
IT Concepts GmbH
Gewerbestrasse 17 www.itcworld.com
The iRis DVR 360° is the world‘s fi rst
compact video-endoscope with a 180°
rotating handle and a rotatable 180° screen.
Art. Nr.: 269-46015-0000-I
269-46020-0000-I
269-46030-0000-I
269-46040-0000-I
269-48015-0000-I
269-48020-0000-I
269-48030-0000-I
269-48040-0000-I
U
D
R
L
5
iRis
5
The Videoscope
Operation Manual
Videoendoskop
Videoendoskop
5

2

3
3

4
Content
Introduction
........................................... 5
Warning Notices and Precautions ......... 6
Scope of Delivery ................................... 8
System Presentation
Overview iRis ........................................................... 9
The Control Panel .................................................. 11
Preparing the iRis
Charging the Battery .............................................. 12
Working with Mains Supply .................................... 13
Inserting the SD Card ............................................. 14
Starting Inspection
Switching-on the iRis ............................................. 15
Status Indicator Line .............................................. 15
Switching-On the LED Light Source ....................... 15
Language Selection ............................................... 16
Format SD Card ..................................................... 17
Setting Time and Date ........................................... 18
Resetting to Default Settings .................................. 19
Image Control ........................................................ 20
Turning the Display ................................................. 21
Controlling the Articulation ..................................... 21
Passing Covings .................................................... 22
Retracting the Endoscope ...................................... 23
Creating and saving Image Captures
Choosing a Standard Setting ................................. 24
Inserting Text ......................................................... 25
Image Capture and Video Recording
in Mode „OFF“ ....................................................... 26
Image Capture and Video Recording
in Mode „ON“ ........................................................ 27
Comparative Measuring with the iRis .....29
Playback of saved Images and
Video Recordings ....................................30
Optimising Camera Settings
Camera Setting ...................................................... 33
Camera Setting Standard ....................................... 34
Camera Setting Manual .......................................... 35
Cleaning and Care ............................... 36
Transport and Storage ......................... 38
Spare Parts and Accessories .............. 39
Service ................................................. 40
Technical Specifications ....................... 40

5
We congratulate you on buying your iRis DVR
X
Industrial Videoscope, in the following just named iRis.
It unites Light Source, TFT Display plus Image Storage and Video Recording Device.
The diversity of inspection objects, materials and lightning conditions often makes it difficult to get
high-quality images. It is easy to adjust the iRis to your application to receive optimal inspection images
even in extreme situations.
Always keep the Operation Manual with the iRis. It contains all information for safe and efficient operation.
However, should you have further questions, feel free to contact our Service Team.
Introduction

6
Read the Operation Manual care-
fully before using the iRis.
Caution! The iRis has to be employed by
skilled and qualifi ed personnel appropriate
to the application. The iRis is designed for
a diversifi ed fi eld of applications in Industry,
Building and Science. Only use the iRis as
intended.
Caution! Never use the iRis in running
machines.
Caution! The iTool has not to be used in
specially designated or prohibited areas
(e.g. Explosion Prevention).
Electric Shock! No unauthorised opening
of the casing. There is high danger of electric
shock due to parts being under voltage. For
higher abrasion resistance the fl exible and
bendable probe is sheathed with tungsten.
This can lead to electric shock at contact with
live parts. Therefore the iRis is never to be
used in or at objects under tension.
Caution! Never look directly into the light
emitting part of the iRis. It can cause injuries
of eyes. Always switch off the Light Source
before changing, controlling or cleaning the
objective or the distal end of the Videoscope.
Caution! Use the iRis in dry environments
only. According IP53 the housing is protected
against splash water. The housing if the iRis
is never to be immerged in water or cleaned
directly under running water.
Caution! Using mains adapter without earth
conducter and without galvanic isolation can
lead to a tungsten braid being under electric
tension. Therefore only use mains supplies
delivered with the iRis.
Caution! If the objective is dirty the distal
end may heathen up. This can lead to ignition
of highly combustible materials. Furthermore
it can lead to burns at direct contact. Regular
cleaning should be made.
Warning Notices and Precautions

7
Caution! When inspecting hot objects the
probe may heat up according ambient tempe-
rature. Avoid direct contact to the probe after
such applications – High risk of burns.
Do not throw battery into fi re.
Do not recharge defect battery, but replace it
immediately.
The iRis is an electric device and must not
be disposed in domestic waste. Pursuant to
European Directive 2002/96/EG on waste
electrical and electronic equipment (WEEE)
and its transposition to national law used up
power tools have to be collected separately and
returned to environmentally compatible
recycling.
Recycling. Withdrawal of batteries
pursuant to the Battery Policy: According
to the German Battery Policy (BattV) we are
obliged to inform you about the rules and
liabilities for disposal and withdrawal of used
batteries and accumulators. According to
§7 German Battery Policy the end-user is
obliged to return used batteries and accu-
mulators. Contaminant-laden batteries and
accumulators are marked with a crossed
dustbin with the chemical symbol of the
contained heavy metal under it (Cd for
cadmium, Hg for mercury, Pb for lead). Batte-
ries and accumulators must not be disposed
in domestic waste and can be handed free
of charge to any designated collection and
withdrawal point. Of course batteries and ac-
cumulators you got from IT Concepts can be
handed or sent to us.
Warning Notices and Precautions

8
The iRis is delivered with the components
shown in adjacent images.
Further interchangeable objectives or additional acces-
sories are not included. These items you will fi nd in this
manual on page 42ff., in our accessories catalogue or
on our homepage www.itcworld.com. We are certainly
pleased being at your disposal for personal consulting as
well.
Scope of Delivery
1
Bedienungsanleitung
iRis
5
iRis
Videoendoskop
U
D
R
L
iRis
X
The innovative Videoscope
U
D
R
L
EG Konformitätserklärung
EC Declaration of Confi rmity
iRis DVR
5
Electromagnetic compatibility directive
2004/108/EC with reference to the
harmonized standards EN61326-1 (2006)
Emission and Immunity.
Elektromagnetische Verträglichkeit Richt-
linie 2004/108/EG unter Bezugnahme der
harmonisierten Norm EN61326-1 (2006)
Emission- und Störfestigkeit.
Lahnau, 31. Januar 2011
Frank Schlagenhauf
Manager Product Development
IT Concepts GmbH
Gewerbestrasse 17 www.itcworld.com
The iRis DVR 360° is the world‘s fi rst
compact video-endoscope with a 180°
rotating handle and a rotatable 180° screen.
Art. Nr.: 269-46015-0000-I
269-46020-0000-I
269-46030-0000-I
269-46040-0000-I
269-48015-0000-I
269-48020-0000-I
269-48030-0000-I
269-48040-0000-I
U
D
R
L
5
iRis
5
The Videoscope
Rechargeable Battery
(in device when delivered)
Charger Operation Manual
Neck HolderITC Case Pocket
8
well.

9
9
Live and saved images as well as
video recordings are shown on the
TFT Display. Image captures and video
recordings can be marked with a text
line.
The probe can be inserted to a
cavity, e.g. a tube. The user can
lock the articulating head of the
probe in the desired position during
inspections. The articulation can be
moved in four directions (up/down and
left/right) which really facilitates passing
multiple covings.
System Presentation
Edge Protector
Bedienhebel
oben/unten
Pins for
Neck Holder
12,7cm (5“) TFT
VGA Colour Display
Lever (left/right)
Control Panel
Control Panel
SD Card Slot
(under Edge Protector)

10
10
Presentation
Pins fpr sunshield Pins fpr sunshield
Battery
Compartment
Handle
Cinch OUT,
external display, etc. 12V DC Plug
ON/OFF LED
Light Source
Swivel Lock
Mechanism
Capture Button
The region to be inspected has
to be that large that movements
with the diameter and length of the
articulating part are possible and
don’t result in seizing. The shea-
thing of the insertion tube is made
of tungsten netting and particular
increases the durability of the fl exible
probe. The inspection area can be
illuminated with a Light Source
(4 mm-Version integrated Light
Source / 6 mm-Version LED on the
Tip).

11
System Presentation
The Control Panel
Using the control panel you can navigate through the menu structure, select and confirm functions.
Navigation up
Power
Memory (open/close
memory mode)
OK-Button / Enter
Capture / Freeze
Record / Cancel
Navigation down
Menu (open/close
on-screen menu)
Navigation left
Navigation right
Setting Brightness
Setting Brightness
Digital Zoom in
Digital Zoom out

12
System Presentation
Charging the Battery
Before charging please pay attention to the included
manual for the charger. For charging the accumulator
has to be removed from the housing. For this the cover
of the battery compartment has to be detached by
releasing the locking screw. To charge the battery
place it in the charger. Charging process is fi nished
when charge indicator lamp continuously glows green.
Caution! Only use the delivered charger to charge
the battery. Otherwise there is high risk of damages to
the cells.
The operating voltage is shown in the status indicator
line on the iRis display. The fully charged battery is
placed in the device when delivered.
Rechargeable Battery
(in device when delivered)
Charger
Battery
Compartment
Cover Battery
Compartment Battery

13
Preparing the iRis
Working with external Power Supply
As an option the iRis can be powered as follows:
1) AC Adapter + Power Supply Cable
2) PowerBelt
3) Car Battery Cable
4) Cigarette Lighter Cable
Note: The 12V DC plug as well as the socket is
marked with a red dot. Assure that both red dots are
visibly opposed when connecting the 12V DC plug to
the iRis.

14
U
D
R
L
Preparing the iRis
Inserting the SD Card
Slightly remove the right edge protector and
put a formatted SD Card (32GB max.) into the
card slot. The SD Card included in the scope
of delivery is already inserted and properly
formatted.
If the SD Card is not formatted you have to
format it as described on page 17.

15
Switching-on the iRis
After having prepared the iRis according this
operation manual switch it on by pressing POWER.
Please inspect the iRis probe as described on page
40 before inserting the endoscope into the inspection
object!
Status Indicator Line
At start-up the iRis always is in Live Mode. At the
bottom of the display the status indicator line can be
seen. It shows the status of zoom, image fl ip, camera,
power supply and light intensity.
Switching-on the LED
The LED is switched on or off by a long push on the
Light Source Button. With short push the intensity of
the LED can be adjusted in three steps.
Starting Inspection
U
D
R
L
U
D
R
L
Integr:Standar d 11.9 100%

16
Language Selection
At delivery status the iRis should already be set to
your language or to English.
At initial operation you should check if the appropriate
language is set and adjust if necessary. The following
languages are available:
– English (default setting)
– German
– French
– Spanish
– Italian
– Polish
– Turkish
If you want to change the language set proceed as
follows:
• MENU
• System Setting - OK
• Select language –
the menu will immediately be shown in the
selected language.
• To quit press MENU again
Starting Inspection
Status Line : ON
Freeze Frame : OFF
Language : English
Date/Time : Press OK
SD info : Press OK
SD format : Press OK
Fabric Settings : Press OK
Software Status : P011 72
Serial Number : 20110815
Language : English
Image Control
Camera Control
Annotation
Dimension
System Setting
Safety remove SD
System Setting

17
Format SD Card
The SD Card delivered with the iRis is already
formatted. To format a SD Card proceed as follows:
Press MENU, select menu item System Setting and
press OK. Using the arrow keys select the menu
item Format SD and press OK. A confirmation
prompt appears on the display. Select via arrow
keys and confirm with OK.
Starting Inspection
Image Control
Camera Control
Annotation
Dimension
System Setting
Safety remove SD
System Setting
Status Line : ON
Freeze Frame : OFF
SD format : Press OK
Date/Time : Press OK
SD info : Press OK
SD format : Press OK
Fabric Settings : Press OK
Software Status : P011 72
Serial Number : 20110815
SD format : Press OK

18
Setting Time and Date
In the delivery status time and date should already
be set.
At initial operation you should check time and date
and set them if necessary.
If you want to change time and/or date proceed as
follows:
Press MENU, select menu item System Setting and
press OK. Using the arrow keys select menu item
Date/Time and press OK. Set the desired time and
date via the arrow keys and then confirm by pressing
OK.
Starting Inspection
Image Control
Camera Control
Annotation
Dimension
System Setting
Safety remove SD
System Setting
Status Line : ON
Freeze Frame : OFF
SD format : Press OK
Date/Time : Press OK
SD info : Press OK
SD format : Press OK
Fabric Settings : Press OK
Software Status : P011 72
Serial Number: 20110815
Date/Time : Press OK

19
Resetting to Default Settings
By selecting the menu item Fabric Settings all
manually changed and adjusted parameters can be
put back to factory setting, except for date, time and
text generator.
– MENU
– System Setting - OK
– Fabric Settings - OK
You are in Live-Mode again afterwards.
Starting Inspection
Image Control
Camera Control
Annotation
Dimension
System Setting
Safety remove SD
System Setting
Status Line : ON
Freeze Frame : OFF
Language : English
Date/Time : Press OK
SD info : Press OK
SD format : Press OK
Fabric Settings : Press OK
Software Status : P011 72
Serial Number : 20110815
Fabric Settings : Press OK

20
Image Control
Image parameter (brightness, contrast and colour as
well as zoom and image flip) can be adjusted under
Image Control in the menu.
Change the select parameter by using the arrow keys.
New settings will immediately be effective. Pressing
OK will reset the marked parameter to default setting.
Using the MENU button will bring you back to Live
Mode.
Caution! The image parameter are effective to the
image displayed as well as to images and videos
being saved. Image captures and video recordings
will be saved as displayed.
Starting Inspection
Image Control
Camera Control
Annotation
Dimension
System Setting
Safety remove SD
Image Control
Brightness |||||||||||||||.............. 50%
Contrast |||||||||||||||.............. 50%
Colour |||||||||||||||.............. 50%
Zoom |............................ 1x
Flip Normal
Dimmen |||||||||||||||.............. 50%
Brightness |||||||||||||||.............. 50%
Table of contents