manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. iWiscloud
  6. •
  7. Accessories
  8. •
  9. iWiscloud Wis-S-O2 User manual

iWiscloud Wis-S-O2 User manual

P a g e 1 | 9
iWiscloud Smart Sensor version
Product Operating Manual
http://www.iwiscloud.com
【Warning】
Please do not attempt to dismantle this delicate product, willful manipulation
might lead to electrical failure. Warranty will be void if product is found to be
tampered with.
【Notice 】: As this product constantly improve, the pictorial diagram might be an
indication of the actual product delivered. Wiscloud is grateful for your choice to
purchase our iWiscloud smart sensors. For your safety and maximizing our product
capabilities, we would highly encourage you to study this operation manual in details.
Please safe keep this operation manual for future references.
P a g e 2 | 9
1. Product Introduction
This product had been designed and manufactured in accordance to strict
International safety standards and achieved CE certifications.
Side view
Back view
1.1. Product specifications
Smart Sensor
Model No.
Detection range
Accuracy
Oxygen
Wis-S-O2
0 – 25%
±0.3%
Formaldehyde
Wis-S-CH
0 – 0.3mg/m3
±0.002mg/m3
PM2.5
Wis-S-PM2.5
0 – 500µg/m3
±2µg/m3
Carbon Monoxide
Wis-S-CO
0 – 600ppm
±0.3ppm
Carbon Dioxide
Wis-S-CO2
350 – 6000ppm
±3ppm
P a g e 3 | 9
Humidity/Temperatu
re
Wis-S-TH
20-90%RH / 0-50°C
±2%RH / ±1°C
Other features
Luminosity, Sound level detection
Operating voltage
AC 100-200V / 50-60Hz
Energy consumption
1 – 2 W
Display panel
LED display or Without display panel
Dimension
Square (100mm*100mm*30mm) or Round (XX*XX*30mm)
1.2. Deployment
iWiscloud smart sensor can be deployed individually or paired together with other
iWiscloud smart home solution suite. If Wiscloud control center is deployed together,
user can do remote monitoring and alert via the Internet cloud.
1.3. Proposed deployed locations
Home, Office, Luxury Hotel, Industrial buildings, Precise engineering / clean rooms or
high-tech farms. Anywhere that you may require to monitor & alert or obtain precise
information of the environment.
1.4. Exterior design
Our smart sensors (square or circular) shaped exterior shells are made up from
Acrylonitrile-Butadiene-Styrene (ABS) plastic. It is strong, stable, durable, safe and
resistant to heat and corrosion. The hive inspired air vents enhances aerodynamic
flow and increases reading accuracy.
1.5. Color Options
Black, Silver, Pure White
1.6. Display Panel Standby
1. When the smart sensor detects continuous 5 minutes of low light (dark or
darkness), it automatically goes into display panel standby mode. The display
panel will emerge again when it detects visible light.
2. While in standby mode, if the smart sensor detects a quantitative change in
noise or sensatory value, the display panel will also emerge.
1.7. Product Feature Expansion
1. Each smart sensor carries one RS-485 port interface, used commonly for
industrial communication.
P a g e 4 | 9
2. Each smart sensor is designed with two optional power relays [see section
2.13 for details] which can be used to power control other electronic products.
These relays are activated whenever the smart sensor defined upper limit is
exceeded.
3. Each smart sensor (other than the PM2.5 model) also has an option to
provide a 4-20mA varying electric power source to a single target.
4. For the advanced smart sensor model, each smart sensor can also capture
and perform relay of 315/433Mhz control signals.
2. Configuring iWiscloud Smart Sensor
In this section, we would explain on the configuration options, following settings ->
configuration in chronological order.
2.1. Main display screen
1. The top value indicates the reading of the smart sensor detection attribute
(depending on smart sensor model)
2. The next row with a loud speaker icon indicates the detected sound level.
The higher the sound level detected, the more “_”would appear.
3. The last row indicates the luminosity level detected.
4. If the smart sensors are paired with iWiscloud control centre, the sensor
exact readings can be obtained from the cloud as seen in below diagram.
P a g e 5 | 9
5. The smart sensor will be occasionally blink in blue which indicate that it is
operational.
2.2. Version
In this section, the smart sensor installed firmware version is displayed.
2.3. Address Setting (Nebula)
In this section, the smart sensor can be configured to communicate with iWiscloud
control center. Each control center has its unique Nebula address value and the
iWiscloud smart sensor MUST configure MATCHING Nebula address value for linkage.
Please refer to iWiscloud control center operation manual in finding out the
iWiscloud control center’s unique Nebula address.
2.4. Room Setting
In this section, the smart sensor can be configured to be operating in one of the
default location zone (within home). This is to facilitate for the iWiscloud control
center in identifying the different smart sensors deployed in the different location
within the home. By default, all smart sensors are set as room ID zero (0). Refer to
below table for the other pre-defined zones.
Room ID (Default value from 0 to 7):
0
1
2
3
4
5
6
7
Living
room
Dining
area
Kitchen
Main
bedroom
Child
room
Guest
room
Study
room
Toilet
2.5. Warning audio
In this section, the smart sensor can be configured to sound a warning audio when
the defined limits are breached. Default value is off, which meant warning audio is
off. Note: Regardless of the warning audio settings, the smart sensor will be blinking
P a g e 6 | 9
in red light when the defined limits are breached, assuming the Warning status is
turned on [see section 2.7].
2.6. 4-20mA output
In this section, the smart sensor can be configured for direct proportion or inverse
proportion for the 4-20mA output. For direct proportional, the constant power
provided is proportional to the smart sensor reading, starting with 4mA at zero
reading and 20mA at reading above the user defined threshold upper limit.
2.7. Warning
In this section, the smart sensor can be configured whether warning is activated
when defined limits are breached. Default value is “on”, which meant the smart
sensor will blink in red light when defined limits are breached. However, when this
setting is turned “off”, regardless if the warning audio selection, the smart sensor
will not indicate alert status. Also, when this setting is turned “off”, all the power
relays option will never be activated.
2.8. Relay 315M/415M
This option is only available for the advanced model. In this section, the smart sensor
can be configured to do mess network relays for 315/415Mhz control signals.
2.9. Exit
This option exits from the configuration menu.
2.10. Reset
When this option is selected, the smart sensor performs a factory reset and restore
all values to default.
2.11. Calibration
When this option is selected, the smart sensor performs an automated calibration of
measured value.
P a g e 7 | 9
2.12. Upper / Lower Limit settings
Depending on the smart sensor model, the upper / lower limit can be configured.
Please see below table for the summary.
Smart Sensor
Model No.
Upper limit
Lower
Limit
Ideal value
Oxygen
Wis-S-O2
Y
N
N
Formaldehyde
Wis-S-CH
Y
N
N
PM2.5
Wis-S-PM2.5
Y
N
N
Carbon Monoxide
Wis-S-CO
Y
N
N
Carbon Dioxide
Wis-S-CO2
Y
N
N
Humidity/Temperatu
re
Wis-S-TH
Y
Y
Y
2.13. Setting up the electrical relays
Please note that the electronic relays only support up to ≤500W and it should be
installed only by qualified trained electrician. The electrical relays are only activated
when the user defined upper limit are met. (For the humiture model, the relays are
activated when either the upper or lower limit threshold are breached). Do note that
the warning option must be “ON”for this relay to be functional.
For power wiring connectivity, please connect up the devices with reference to the
diagram below.
3. Points to note
P a g e 8 | 9
For accurate readings, please avoid install smart sensor in enclosed area.
Please ensure the operating environment is between 0℃to 50℃
Please do not deploy the smart sensor within an enclosed metal cover as this
will affect its wireless communication capabilities
If multiple smart sensors are installed, please install them each at least 2cm
apart.
For best results, please install smart sensor 1.2m above floor level.
Avoid exposing the smart sensor in highly corrosive environment (e.g.
hydrosulfide, hydrochloric, alkali, halogenic, etc..)
Avoid wetting the smart sensor hive surface area as it will reduce in device
detection accuracy
Avoid frosting the smart sensor hive surface area as it would damage the hive
structure and permanently damage device capabilities.
4. Product listing
4.1. iWiscloud smart sensor x 1
4.2. Operating manual x 1
4.3. Wall fixture bracket x 1
4.4. Wall fixture screws x 2
4.5. Warranty card x 1
4.6. Product certification card x1
5. Warranty coverage
Wiscloud Singapore PTE LTD provides the following International warranty coverage
for iWiscloud smart sensor:
Warranty Period
18 months
Scope of Warranty
Electronic parts & sensory module
Warranty Service
Carry in - one to one product exchange
iWiscloud smart sensor is warranted for the specified Warranty Period from
the date of original retail purchase (proof of receipt required) against
defects in quality and materials under normal, non-commercial use.
P a g e 9 | 9
Abnormal usage caused damage is not warranty covered. Wear and tear
damage is also not warranty covered.
Abnormal usage includes (force majeure), but limited to, deliberate
damaging, disassembling, dismantle, manipulating warranty sticker, power
overloading, water damaging or other man-made caused product damages.
Wear and tear damage includes, but not limited to, exterior surface defects
due to natural environmental cause and mishandling.
This warranty does not cover missing accessories or external parts of the
product. Such claim should be made within 3 days from the date of original
retail purchase with the supplying agent.
For the avoidance of doubt, minor imperfections within design
specifications and that do not materially alter functionality of the product
are not considered a defect under this warranty.
6. Company Information
Wiscloud Singapore PTE LTD
Address: 62 Ubi Road 1, Oxley Bizhub 2 #08-13, Singapore 408734
Website: http://www.iwiscloud.com
Email: support@iwiscloud.com
Wiscloud Singapore PTE LTD reserves its right in the terms and conditions
interpretation found within this operational manual.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment should be installed and operated with a minimum distance of 20cm between the
radiator and your body.

This manual suits for next models

5

Popular Accessories manuals by other brands

B.E.G. LUXOMAT PD2 MAX AP Slave quick start guide

B.E.G.

B.E.G. LUXOMAT PD2 MAX AP Slave quick start guide

Walchem WebMaster instruction manual

Walchem

Walchem WebMaster instruction manual

Sensata IWR USB Series quick start guide

Sensata

Sensata IWR USB Series quick start guide

Scame electrical solutions Advance-GRP installation manual

Scame electrical solutions

Scame electrical solutions Advance-GRP installation manual

Panasonic NN-TK922SS installation instructions

Panasonic

Panasonic NN-TK922SS installation instructions

Melissa Electric Heating Sheet 631-087 Specification sheet

Melissa

Melissa Electric Heating Sheet 631-087 Specification sheet

Orion TeleTrack 9441 instruction manual

Orion

Orion TeleTrack 9441 instruction manual

AMIX PBW-3U user manual

AMIX

AMIX PBW-3U user manual

STEINEL IS 1 user manual

STEINEL

STEINEL IS 1 user manual

Honeywell SIXMINICT Installation instructions manual

Honeywell

Honeywell SIXMINICT Installation instructions manual

Extron electronics Architectural Adapter Plate AAP 301 installation instructions

Extron electronics

Extron electronics Architectural Adapter Plate AAP 301 installation instructions

Fenix Watts V25 PLUG-IN Quick installation manual

Fenix

Fenix Watts V25 PLUG-IN Quick installation manual

Livoo TEA304 user manual

Livoo

Livoo TEA304 user manual

Panasonic MA2J1120G Specification sheet

Panasonic

Panasonic MA2J1120G Specification sheet

Audio Technica UniMix AT8681 Product information

Audio Technica

Audio Technica UniMix AT8681 Product information

Qimarox PALLETDISPENSER PD1 manual

Qimarox

Qimarox PALLETDISPENSER PD1 manual

INNOBIZ musilia Instructions for use

INNOBIZ

INNOBIZ musilia Instructions for use

Heat Controller Flow Controllers Installation, operation & maintenance manual

Heat Controller

Heat Controller Flow Controllers Installation, operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.