IMPORTANT SAFETY INFORMATION
READ ALL INSTALLATION INSTRUCTIONS
Warning — Risk of injury: Children, the elderly, and the
infirmshouldnotusethespaunlesstheyaresupervisedatall
times. Infants should not be permitted in the spa at water
temperatures over 100°F (38°C).
Spa water temperatures in excess of 104°F are not
recommended. High water temperatures in excess of 104°F
(40°C)and prolongedperiodsofusecanraiseinternalhuman
body temperature excessively and impair the body’s ability to
regulate its internal temperature.
Pregnant women and people with heart circulatory prob-
lems,ordiabetes,shouldconsulttheirphysiciansbeforeusing
the spa at water temperatures over 100°F (38°C).
Limit your initial use of the spa to 10 –15 minutes. High
body temperatures affect people differently; consult your
physicianaboutyour safetyandcomfortbefore usingthespa.
If your spa product does not have a thermometer, we
recommend that you use a medical (clinical) thermometer for
an accurate measurement of spa water temperatures. Other
types of thermometers generally available, such as those
used for swimming pools, are not sufficiently accurate to
determine spa water temperatures.
Extra care should be taken when using the spa and
consuming alcoholic beverages. Alcohol, drugs, or certain
medications, such as tranquilizers, affect a person’s ability to
withstand high temperatures and may produce dangerous
effects,includingdrowning. Personsusingmedicationshould
consult with a physician before using a spa.
Danger — Risk of injury: Do not remove the suction grille!
Itisasafetydeviceandmustalwaysbeinplaceonthesuction
fittingto minimizethepotentialhazardof hairentanglementor
body entrapment.
Keep body, hair, and clothing a minimum of 12 inches
away from suction fitting and skimmers at all times when the
spa is operating. Hair longer than shoulder length should be
secured close to the head, or a bathing cap should be worn.
Do not operate the spa if the suction cover is broken or
missing. Contactyour Dealer for replacement cover if broken
or missing.
The wet surface of the spa is slippery. Use care when
entering and exiting.
DANGER — Risk of child drowning: Do not permit children
to use this product unless they are closely supervised. Use a
locked cover to prevent unattended access.
DANGER — RISK OF ELECTRICAL SHOCK: When install-
ing and operating this electrical equipment, always follow
basic safety precautions including the following.
Warning: Awireconnectorisprovidedattheelectricalcabinet
on this spa to connect a minimum No. 8 AWG (8.4 MM2) solid
copperconductorbetween this spa andanymetalequipment,
metal enclosures of electrical equipment, metal water pipe, or
conduit within 5 feet (1.5 m) of the spa.
Do not use electrically connected devices such as televi-
sion, radio, or stereo speakers, lights, cooking devices, or
telephoneswithin5feet(1.5m)ofthespawhilethespaisbeing
used. Lighting fixtures must not be located directly above or
within5 feet(1.5m) ofthespa. If locatedwithin10 feet(3.0m)
of the spa, they must be on a circuit protected by a Ground
Fault Circuit Interrupter (GFCI).
Allfixedmetalobjectslocatedwithin5feetofthespa,such
as fence posts, railings, door frames, greenhouse structures,
gutters, etc., must be attached to the bonding bar on the
outsideofthespaelectricalcabinetusing#8solidcopperwire.
With #8 solid copper wire, bond the spa to the house
electrical panel or approved local bond.
The spa must be installed so that its components and
equipment are accessible and its water drainage system is
adequate to drain water away from electrical components.
Refer to Installation Instructions.
CAUTION: Do not turn power ON to the spa unless it is filled
withwaterto the normalwaterlevel,which is tothewaterlevel
indicator mark on the skimmer frame. Activating the spa
without sufficient water can damage the circulation pump and
may cause a fire.
Read manufacturer’s safety information provided with all optional equipment.
Your spa must be installed in a 115VAC, 20 AMP circuit:
1. The spa is supplied with a 15 foot line cord which
terminates with an integral GFCI plug. Locate the spa near to
aweather-protectedoutlet,butnocloserthan10feet. DONOT
USE AN EXTENSION CORD! Using an extension cord is
hazardous and will decrease the amount of power to the unit,
causing slow heating, poor whirlpool performance, or system
malfunction.
2. Replacedamagedlinecord immediately. Donotbury
line cord. Connect only to a properly grounded receptacle.
3. Bring the line cord out from under the skirt. Remove
skirt screws as required to gain access. Make sure the line
corddoesnotlieacrossawalkwayorinaheavilytraveledarea
where it may be a safety hazard or become damaged.
4. At initial start-up and before each use thereafter with
powerON,pushtheGFCItestbutton. Theresetbuttonshould
pop out. Push this button in to reset. If the interrupter fails to
operate in this manner, there is a ground current flowing or a
device malfunctioning, indicating the possibility of electrical
shock. Turn off power and do not use the spa until the
source of the problem has been identified and corrected.
20 AMP RECEPTACLE
GFCI