Upper Arm Type
Blood Pressure Monitor
Model Number: B06T
--------------------------------------------------------------------------
USER MANUAL
CONTENTS

3
1. Introduction and Intended Use.............................................................................................. 3
2. Important Information on Blood Pressure and its Measurement...........................................5
3. Components of your blood pressure monitor.........................................................................7
4. Using your Monitor for the First Time.....................................................................................8
5. Measurement Procedure..................................................................................................... 9
6. Care and Maintenance........................................................................................................ 18
7. Warranty............................................................................................................................... 18
8. Certifications........................................................................................................................ 18
9. Technical Specifications.................................................................................................. 19-20
10. EMC Declaration.......................................................................................................... 21-25
10. Warranty Card.............................................................................................................. .....26

4
1.Introduction and Intended Use
The device is intended to measure systolic and diastolic blood pressure as well as the
pulse by wrapping around the upper arm with cuff circumference ranging from 22cm to
40cm .
The device is used for adult that age is more than 12 years old ,and the intended
populations are the patients with hypertension or need blood pressure monitoring.The
device is not used for patients under dialysis therapy or on anticoagulant, antiplatelets, or
steroids.
The device can be used in medical facilities or at home.
Before using, please read this instruction manual carefully and then keep it in a safe place.
Please contact your doctor for further questions on the subject of blood pressure and its
measurement.
Warning:Not suitable for neonatal and infants.
Warning: Not suitable for pregnant, including pre-eclamptic patients, not suitable for self-use
in public areas, Not intended for use in the emergency medical services environment.
Warning:This device can not be used together with hf surgical equipment.
1.1. Remember…
• Only a health-care professional is qualified to interpret blood pressure measurements.
• This device is NOT intended to replace regular medical checkups.
• It is recommended that your physician review your procedure for using this device.
• Blood pressure readings obtained by this device should be verified before prescribing or
making adjustments to any medications used to control hypertension. Under no circumstances
should YOU alter the dosages of any drugs prescribed by your doctor.
• This monitor is intended for use by adults only. Consult with a physician before using this
instrument on a child.
•In cases of irregular heartbeat (Arrhythmia), measurements made with this instrument should
only be evaluated after consultation with your doctor.
• Familiarize yourself with the section titled "Important Information on Blood Pressure and its
Measurement". It contains important information on the dynamics of blood pressure readings
and will help you to obtain the best results.
• Host products, including accessories, shall be processed in accordance with local regulations
after reaching the life cycle.
NOTE!
• This device contains sensitive electronic components. Avoid strong electrical or
electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave
ovens) during use. These can lead to erratic results.
• Do not attempt to service or repair this device yourself. Should a malfunction occur, refer to
local distributor or the manufacturer.
Warning:
• Too frequent measurements can cause injury to the PATIENT due to blood flow interference

5
• Don’t place the cuff over wound part.
• Pressurization of the CUFF can temporarily cause loss of function of simultaneously used
monitoring ME EQUIPMENT on the same limb.
• Apply CUFF and its pressurization to any limb where intravascular access or arteriovenous
(A-V) shunts exist, can temporarily interfere with blood flow and may cause injury to the patient
• Apply CUFF and its pressurization on the side of the patient's mastectomy or lymph node
removal can cause injury.
Contraindication
Use of this instrument on patients under dialysis therapy or on anticoagulant, antiplatelets, or
steroids could cause internal bleeding.
1.2 Warnings and Precautions
Warning: Do not use cuffs, AC adapters or batteries other than those included with this
product or replacement parts supplied by the manufacturer.
Warning: Do not use the batteries and the AC adapter to provide power at the same time.
Warning: This system may fail to yield specified measurement accuracy if operated or stored
in temperature or humidity conditions outside the limits stated in the specifications section of
this manual.
Warning: The separate ac adapter which is intended to connect USB interface of Blood
Pressure Monitor has not been evaluated according to IEC 60601-1. The safety of the product
shall be reappraised when it power supply by a separate ac adapter.
Warning: The user must check that the equipment functions safely and see that it is in proper
working condition before being used.
Warning: No modification of this equipment is allowed.
Warning: The device is not suitable for use in the presence of flammable anesthetic mixtures
with air or with oxygen or nitrous oxide.
Warning: Not suitable for use in the presence of flammable agents.
Warning: If having a potential allergic reaction when using the cuff of the device, the user
should immediately remove it and contact the manufacturer or local distributor
Warning:Regularly checking the operation of the blood pressure monitor to ensure that it does
not cause long-term damage to the patient's blood circulation.
Warning:The performance of the blood pressure monitor could be affected by extreme
temperatures, humidity and altitude.
Warning:The hose of the cuff can only be connected with the manufacturer's blood pressure
monitor,and used in other equipment may cause malfunction.
Warning:Do not bend, squeeze or restrict the connecting hose of cuff during the storage or
operation,, otherwise it will cause injury.
Warning: This equipment shall not be serviced or maintained while in use with the patient
Warning: The patient is an intended operator, the functions of monitoring blood pressure and
pulse rate can be safely used by patient. The routine clean and disinfect can be performed by
the patient.
Warning: Use of power adapter
1.Adapter: input 100-240V, 50/60Hz output DC 5V 1A

6
2.Do not to position the device to make it difficult to operate the disconnection device while
using adaptor.
3.Do not be prone to water leakage, high temperature, moisture, direct sunlight and more or
more corrosive gas environment. And Do not use this product in the above environment.
Caution: To avoid any possibility of accidental strangulation, keep this unit away from children
and do not drape tubing around your neck.
Caution: To avoid damaging the device, keep this unit away from children and pets.
Caution: The standard material used for the bladder and tubing is latex-free.
Attention: Self-measurement means control, not diagnosis or treatment. Unusual values must
always be discussed with your doctor. Under no circumstances should you alter the dosages
of any drugs prescribed by your doctor.
Attention: The pulse display is not suitable for checking the frequency of heart pacemakers!
Attention: In cases of irregular heartbeat, measurements made with this instrument should
only be evaluated after consultation with your doctor.
Note: To obtain the greatest accuracy from your blood pressure instrument, it is recommended
that the instrument be used within the specified temperature and the relative humidity, please
see the Technical Specifications
Note: The cuff is treated as the applied part.The user should contact the manufacturer for
assistance, if needed, in setting up, using or maintaining the device.
2. Important Information on Blood Pressure and its Measurement
2.1. How does high or low blood pressure arise?
Your level of blood pressure is determined in the circulatory center of the brain and adjusts to a
variety of situations through feedback from the nervous system. To adjust blood pressure, the
strength and speed of the heart (Pulse), as well as the width of circulatory blood vessels is
altered.Blood vessel width is controlled by fine muscles in the blood vessel walls.
Your level of arterial blood pressure changes periodically during heart activity: During the
“blood ejection” (Systole) the value is highest (systolic blood pressure value). At the end of the
heart’s “rest period” (Diastole) pressure is lowest (diastolic blood pressure value).
Blood pressure values must lie within certain normal ranges in order to prevent particular
diseases.
2.2. Which values are normal?
Please refer to the diagram below(Picture-01)

7
Picture-01
Blood pressure is very high if your diastolic pressure is above 90 mmHg and/or your systolic
blood pressure is over 160 mmHg, while at rest. In this case, please consult your physician
immediately. Long-term values at this level endanger your health due to continual damage to
the blood vessels in your body. If your systolic blood pressure values are between 140 mmHg
and 159mmHg and/or the diastolic blood pressure values between 90 mmHg and 99mmHg,
consult your physician. Regular self-checks are necessary. If you have blood pressure values
that are too low, (i.e., systolic values under 105mmHg and/or diastolic values under 60 mmHg),
consult your physician. Even with normal blood pressure values, a regular self-check with your
blood pressure monitor is recommended. You can detect possible changes in your values
early and react appropriately. If you are undergoing medical treatment to control your blood
pressure, keep a record of values along with time of day and date. Show these values to your
physician. Never use the results of your measurements to independently alter the drug doses
prescribed by your physician.
Further information
• If your values are mostly normal under resting conditions but exceptionally high under
conditions of physical or psychological stress, it is possible that you are suffering from
so-called “labile hypertension.” Consult your doctor.
• Correctly measured diastolic blood pressure values above 120mmHg require immediate
medical treatment.
2.3. What can be done if regular high or low values are obtained?
1) Consult your doctor.
2) Increased blood pressure values (various forms of hypertension) are associated with
considerable health risks over time. Arterial blood vessels in your body are endangered due to
constriction caused by deposits in the vessel walls (Arteriosclerosis). A deficient supply of
blood to important organs (heart, brain, muscles) can result from arteriosclerosis. Furthermore,
the heart will become structurally damaged with increased blood pressure values.
3) There are many different causes of high blood pressure. We differentiate between the
common primary (essential) hypertension, and secondary hypertension. The latter group can

8
be ascribed to specific organ malfunctions. Please consult your doctor for information about
the possible origins of your own increased blood pressure values.
4) There are measures which you can take to reduce and even prevent high blood pressure.
3. Components of your blood pressure monitor
3.1. Measuring unit
Picture-02
Picture-03
3.2 Features of Model B06T
1. Talking function 2. Data storage: 99 sets memory
3. Average value function 4. Low battery display 5. WHO function

9
6. Auto power-off 7.Volume adjustment
4. Functions Introduction
4.1. Volume setting
Short-Press “MEM/VOL+" or “MEM/VOL-" button for volume setting. The volume is a total of 3
levels with broadcast sound of “minimum volume”(level 1) - “volume down / volume up"(level 2,
middle volume) - “maximum volume”(level 3), the default is level 2 (middle volume).
1) When Short Press “MEM/VOL+”, the voice says “volume up - maximum volume”;
2) When Short Press "MEM/VOL-", the voice say “volume down - minimum volume”;
3) After restarting, resetting or replacing the battery, the device volume is restored to the
default level 2 (middle volume).
4.2. Memory mode
Long Press the “MEM/VOL+” button to enter the device memory mode. If the total memory
value is ≥3, then broadcast the average value of the latest three values in default; if<3, then
broadcast the latest value only,
Short Press the “MEM/VOL+" or "MEM/VOL-" button again to broadcast the other records in
time order, return back to the latest memory value after reach the end of all records, broadcast
in cycling.The device has max 99 groups of memories (measurement values).
In the state of memory mode, Long Press the “MEM/VOL+” and “MEM/VOL-” buttons at the
same time for 3 seconds to delete all memories; Short Press the “MEM/VOL+” to broadcast
the latest value, and then to the historical records; Short Press the "MEM/VOL-" to broadcast
the most historical value, and then back to the latest record.
•Note: In Mute mode, the memory value cannot be broadcasted out by voice.
4.3. Device broadcast language select
Long Press the "MEM/VOL-", after sound“DI”, it means the device successes to switch into
another broadcast language;Also can select the broadcast language through APP. In the
standby, connect and open the APP, go to the “START" main interface, click “Device Voice"
button for the language settings.
During the blood pressure measuring, language switching is not possible; after resetting or
replacing the battery, the default settings are restored.
4.4. Low Power reminder
when the power is 3.5V +/- 0.2V, the device broadcasts “Battery low power"; when lower than
3.3V +/- 0.2V, the device will automatically shut down.
5. Measurement Procedure
Note: You should always be seated and calm before and during measurement.
5.1. Before measurement:
• Avoid eating and smoking as well as all forms of exertion directly before measurement. These

10
factors influence the measurement result. Find time to relax by sitting in an armchair in a quiet
atmosphere for about ten minutes before taking a measurement.
• Remove any garment that fits closely to your upper arm.
• Always measure on the same arm (normally left).
• Always compare measurements taken at the same time of day, since blood pressure
changes during the course of the day, as much as 23-36mmHg.
5.2. Common sources of error:
Note: Comparable blood pressure measurements always require the same conditions!
•Conditions should always be quiet.
•All efforts by the user to support the arm can increase blood pressure. Make sure you are in a
comfortable, relaxed position and do not flex any of the muscles in the measurement arm
during the measurement. Use a cushion for support if necessary.
• If the arm artery lies considerably lower or higher than the heart, an erroneously high or low
blood pressure will be measured! Each 25-30cm difference in height between your heart and
the cuff results in a measurement error of 10mmHg!
Note: Only use approved cuffs!
• A loose cuff or a sideways protruding air pocket causes false measurement values.
• With repeated measurements, blood accumulates in the arm, which can lead to false results.
Consecutive blood pressure measurements should be repeated after a 1 minute pause or after
your arm has been held up in order to allow the accumulated blood to flow away. If you decide
to take your Averaging Mode measurement again, be sure to wait at least one minute
beforehand.
5.3. Fitting the Cuff
Please refer to picture-04
a) The cuff is preformed for easier use. Remove tight or bulky clothing from your upper arm.
b) Wrap the cuff around your upper left arm. Make certain the cuff lies approximately 1/2” to
3/4” (1 to 2 cm) above the elbow. Important ! The on the edge of the cuff (Artery Mark) must lie
over the artery which runs down the inner side of the arm.
c) To secure the cuff, wrap it around your arm and press the hook and loop closure together.
d) There should be little free space between your arm and the cuff. You should be able to fit 2
fingers between your arm and the cuff. Cuffs that don’t fit properly result in false measurement
values. Measure your arm circumference if you are not sure of proper fit.
e) Lay your arm on a table (palm upward) so the cuff is at the same height as your heart. Make
sure the tube is not kinked.
f)Remain seated quietly for at least two minutes before you begin the measurement.

11
Picture-04
Change the cuff may result in unacceptable risks,the operator should pay attention to the
following:
• Only use Jamr authorized cuffs, as those not approved for use with the device may provide
inaccurate measurements, injury, and/or damage the device.
• Do not force cuff connection into the opening.
• Do not forcefully bend the arm cuff or air tube. Do not fold tightly.
5.4. Measure Procedure
Refer to picture-17
The monitor is designed to take measurements and store the measurement values in
Memory.
1. Sit comfortably in a chair with your feet flat on the floor.
2. Under the power off, short press the”START/STOP" to start the measurement, the voice
broadcast starts, the background music sounds up while during measuring; when the
measurement ends, the device broadcasts the measurement result, and then the button
indicator will display blue or yellow or red LED lights for 60 seconds. The device will
automatically shut down if there is no operation within 60 seconds (when APP disconnected).
Stretch your arm forward on the desk and keep relaxing, make sure the palm of hand is
upturned. Make sure arm is in correct position, to avoid body movement. Sit still and do not
talk or move during the measurement.
After the cuff has been appropriately positioned on the arm and connected to the blood
pressure monitor, the measurement can begin:
1 ) Operate via the App on smart phone with Bluetooth
STEP 1- Install the Health Care BLE from google play store or Apple app store.See the
Picture-05

12
Health care BLE
NMT Co
Picture-05 Data transmit APP
STEP2- Press the Power on/off button to open the Bluetooth of B06T unit
STEP3- Open the Bluetooth of receiving end (smart phone,IPad)
STEP4- Register the user’s information (name,age,gender,height&weight and so on). See the
Picture-06 user registering interface.
Picture-06 User registering interface
STEP5- Select Device
After filling out the user information, user can see the Picture-07 interface. Please choose the
Blood Pressure Monitor,User can see the Picture-08 connecting interface.

13
Picture-07 Device selecting interface Picture-08 Device connect interface
STEP6-User Setting
6.1Pressthe“ ”, user can see the Picture-09 ,and then user edit information or add new
Users.
6.2 Voice Language Setting:User can choose the appropriate voice language, see the
Picture-10.
Picture-09 user setting interface Picture-10 voice language setting
STEP7-Device connecting
Press “connect” icon, the pressure monitor will successfully connect the Health Care BLE in
receiving end, If the Health Care BLE display “Connected” as show Picture-11&12,user can
start measuring,if display “try again” as show Picture-13,user should check the pressure
monitor power on or off and the Bluetooth of receiving end is on or off.

14
Picture-11 connecting Picture-12 Connecting Picture-13 Connecting
Interface successfully unsuccessfully
STEP8-Taking measurement
Once the pressure monitor is connect with receiving end with Bluetooth, user can start
measurement on the Health Care BLE . Press the “START”button and start the testing as
shownPicture-14. When measuring is completed, the pressure monitor will voice
measurement result, user can see the Picture-15 display.
Picture-14 Starting Measurement Picture-15 Completing measurement
STEP9-open and display the measurement data
Press the ,user can see the measurement result as show Picture-15.If user press
the , the historical measurement result displays with chart as show Picture-16.

15
Picture-15 Measurement Picture-16 Measurement data
data display display as chart
Recommended Use Methods
1. recommendation that the PATIENT relax as much as possible and not talk during the
measurement PROCEDURE
2. recommendation that 5 min should elapse before the first reading is taken
3. any reading can be affected by the measurement site, the position of the PATIENT,
exercise, or the PATIENT’S physiologic condition
4. performance of the AUTOMATED SPHYGMOMANOMETER can be affected by extremes
of temperature, humidity and altitude
5. To stop the inflation or measurement, push the START/STOP button. The
monitor will stop inflating, start deflating, and will turn off.
6. After the monitor has detected your blood pressure and pulse rate, the cuff automatically
deflates. Your blood pressure and pulse rate are displayed.
7. If getting a suspicious reading after finishing measurement,you should consult the doctor.
Self-diagnosis of measurement results are dangerous.
8. The monitor will automatically turn off after one minute.

16
Picture-17
5.6. Error Indicates
SYMBOL CAUSE CORRECTION
No air pressuring
After press the
“start/stop”button
Battery lack of power Charge the battery
Er1 Sensor abnormal Check if the pump is working or not. If it is
working, then the problem is sensor
abnormal. Please send it to the local
distributor.
Er2 Monitor could not detect
pulse wave or cannot
calculate the blood
pressure data
Check if the air releasing is too slow or not. If
it is too slow, please check if there is any dust
in the tube plug of the cuff and the cuff port in
the device. If yes, please clean and start the
measurement again. If no, please send the
device back to the local distributor.
Er3 Measurement result is
abnormal
(SYS≦45mmHg,
DIA≦24mmHg)
Occasionally-measure for one more time/
Always - send it to local distributor
Er4 Too loose cuff or air
leakage (Cannot inflate to
30mmHg within 15s)
Tie the cuff correctly and make sure the air
plug is properly inserted in the unit
Er 5 The air tube is crimped Correct it and make the measurement again
Er 6 The sensor is sensing
great fluctuation in the
pressure
Please keep quiet and don’t move
Er 7 The pressure that the
sensor sensing is over the
limit
Please send back to the local distributor
Er 8 The demarcation is
incorrect or the device has
not been demarcated
Please send back to the local distributor

17
5.7 Trouble shooting
5.8 SYMBOL DESCRIPTIONS
The following symbols may appear in this manual, on the Digital Blood Pressure Monitor B06T,
or on it's accessories. Some of the symbols represent standards and compliances associated
with the Digital Blood Pressure Monitor B06T and its use.
Authorized Representative in the European Community
CE Mark: conforms to essential requirements of REGULATION (EU) 2017/745
Date of manufacture.
Manufacturer
SN Specifies serial number
Type BF applied part
Direct current
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
Follow instructions for use
Put up

18
fragile
Keep dry
Avoid the sun
handle gently
temperature range
5.9. Discontinuing a Measurement
If it is necessary to interrupt a blood pressure measurement for any reason (e.g the patient
feels unwell), the Start/Stop button can be pressed at any time. The device then immediately
lowers the cuff pressure automatically.
5.10. Using the AC Adapter
You may also operate this monitor using the AC adapter (output 5V DC/1A).
Use only the approved AC adapter to avoid damaging the unit(class II).
a) Ensure that the AC adapter and cable are not damaged.
b) Plug the adapter cable into the AC adapter port on the right side of the blood pressure
monitor.
c) Plug the adapter into your electrical outlet. When the AC adapter is connected, no battery
current is consumed.
Note: No power is taken from the batteries while the AC adapter is connected to the monitor. If
electrical power is interrupted,
(e.g., by accidental removal of the AC adapter from the outlet) the monitor must be reset
by removing the plug from the socket and reinserting the AC adapter connection.
5.11 Battery Recharging
It can be recharged when it is turned on or off. Blood pressure cannot be measured while
recharging. The red LED light keeps flashing while recharging and the green LED light is
always on when fully recharged.
•If recharging when power-on, it will go directly to the standby state while cannot measure the
blood pressure. If pull out the USB cable while recharging, Short-Press the“Start/Stop" button
to start the blood measuring. During the recharging, the device will shut down automatically if
there is no any operation after one minute, while the recharging continues till fully recharged.
During the recharging, can operate the memory value broadcast, volume adjustment,
and language switching; Short-Press “Start/Stop" button to exit from memory mode to volume
adjustment, language switching.

19
6. Care and Maintenance
Wash hands after each time measurement.
If one device is used by different patients, wash hands before and after each use.
The device,including cuff should be cleaned every week,and the effective repetitive cleaning
times is 390 times during the shelf life.
a) Do not expose the device to either extreme temperatures, humidity, dust or direct sunlight.
b) The cuff contains a sensitive air-tight bubble. Handle this cuff carefully and avoid all types of
stress through twisting or buckling.
c) Clean the device with a soft, dry cloth. Do not use gas, thinners or similar solvents. Spots on
the cuff can be removed carefully with a damp cloth and soapsuds. The cuff with bladder must
not be washed in a dishwasher, clothes washer, or submerged in water.
d) Handle the tube carefully. Do not pull on it. Do not allow the tubing to kink and keep it away
from sharp edges.
e) Do not drop the monitor or treat it roughly in any way. Avoid strong vibrations.
f) Never open the monitor! This invalidates the manufacturer’s warranty.
g) Batteries and electronic instruments must be disposed of in accordance with the locally
applicable regulations, not with domestic waste.
Accuracy test
Sensitive measuring devices must be checked for accuracy from time to time. We recommend
a periodical inspection of your unit by an authorized dealer every 1 years. Please turn to local
distributor or the manufacturer.
7. Warranty
Your blood pressure monitor is guaranteed for 1 years against manufacturers’ defects for the
original purchaser only, from date of purchase. The warranty does not apply to damage
caused by improper handling, accidents, professional use, not following the operating
instructions or alterations made to the instrument by third parties.
Warranty only applies to the instrument. All accessories including the cuff are guaranteed for
one year, USB charging cable is not included.
There are no user serviceable parts inside. Batteries or damage from old batteries is not
covered by the warranty.
Note: According to international standards, your monitor should be checked for accuracy every
year.
8. Certifications
Device standard:
This device is manufactured to meet the European blood pressure monitors:
IEC 80601-2-30/ISO81060-1/ISO81060-2/IEC60601-1-11/ IEC60601-1
Electromagnetic compatibility:
Device fulfills the stipulations of the International standard
IEC60601-1-2

20
9. Technical Specifications
Model: B06T
Wight: 237g (AC adapter is not included)
Display: None
Size: 120 (W) x 62 (L) x 29(H) mm
Accessories: 1×Main Device, 1×Cuff, 1×Users manual, 1×Warranty card
Operating Conditions: Temperature: 5℃to 40℃;Humidity: 15% to 93% RH;
Pressure altitude:70KPa~ 106Kpa
Storage And Shipping Conditions:Temperature: -25℃to 70℃; Humidity: 10% to 93% RH;
Pressure altitude: 70KPa~ 106Kpa
Measuring method: Oscillometric
Operating method: Continuous operation
Pressure sensor: Resistive
Measuring range: DIA: 40-130mmHg; SYS: 60-230mmHg
Pulse: 40 to 199 per minute
Cuff pressure display range: 0–295 mmHg
Memory: Automatically stores the last 120 measurements for 2 users (total 240)
Measuring resolution: 1 mmHg
Accuracy: Pressure within ± 3 mmHg / pulse ± 5 % of the reading
Power source: a)Lithium battery,3.7V
b) AC adapter INPUT:100-240VAC 50/60HZ OUTPUT:5VDC 1A
Accessories: Wide range rigid cuff 23-36cm
Automatically power off : 60 seconds
Users: Adult
Software Version: V1.1.1
Expected service life of the device and accessories: 5 years
Technical alterations reserved!
10. EMC Declaration
10.1 Wireless Communication
This device uses a 2.4GHz band frequency. Use this device around of the devices which have
the same frequency such as wireless router, electronic microwave oven, or wireless
instrument, this may cause radio interference each other. When radio interference happened,
please turn off the not-in- using device or move the device to the place without radio
interference to use.
Transmission frequency: 2.4GHz
Modulation method: GFSK
Frequency range: 2400 - 2483.5 MHz ( 2MHz)
Transmitting power: s20dBm
Table of contents
Other Jamr Technology Blood Pressure Monitor manuals

Jamr Technology
Jamr Technology B07 User manual

Jamr Technology
Jamr Technology W03 User manual

Jamr Technology
Jamr Technology BC31L User manual

Jamr Technology
Jamr Technology B22 User manual

Jamr Technology
Jamr Technology B02T User manual

Jamr Technology
Jamr Technology W02 User manual

Jamr Technology
Jamr Technology W02 User manual