jbc TID User manual

TID
Digital Thermometer
INSTRUCTION MANUAL

2
Manual ....................................................... 1 unit
Ref. 0028993
Case ........................................................... 1 unit
Ref. 0014853
Packing List
The following items are included:
This manual corresponds to the following reference:
TID-B
TID Console ............. 1 unit Thermocouple
Cable ......................... 1 unit
Ref. 0014848
TID Sensor ............... 1 unit
includes:
TID Thermocouple Sensor Type K
Ref. STD-A
TID Sensor Stand
Ref. 0014847

3
Features and Connections
Thermocouple Cable
Ref. 0014848
Thermocouple
Sensor Type K
Ref. STD-A
Sensor Stand
Ref. 0014847
LCD Display
Operating
Buttons
On / Off
Button
TID Digital Thermometer comes with a handy case. The case is designed to be used with TID inside.
There is no need to take the console and the sensor out to work with, but it is possible if desired.
Menu
Button
TID Sensor
TID Console
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

ºC
STD
4
Main Display:
Measurement of the current temperature
or value for min/max/hold.
Auxiliary Display:
Measurement of the current temperature.
Battery Indicator:
Indicates battery status.
Unit Display:
Display of units or min/max/hold.
Operating Buttons
On / Off Button
One-click: Switch on the device or Activate / deactivate lighting
Long press: Switch off the device
Up / Down Buttons
One-click: Display of the min/max value
Long press: Reset the min/max value of the current measure-ment
Both simultaneously:Rotate display, overhead display
Function Button
One-click: Hold measurement function
Long press, 2s: Open configuration menu (ONF appears in the display)
LCD Display

5
PoFF
LitE
Unit
Shut-off time
Backlight
Display unit
No automatic shut-off; indicated by “oFF”.
Automatic shut-off after a selected time in
hours:minutes, during which no buttons have been
pressed. For example 1:15 (1 hour, 15 minutes).
Backlight deactivated; indicated by “oFF”.
Automatic shut-off of the backlight after a selected
time in minutes:seconds, during which no buttons
have been pressed. For example 0:30 (0 hour, 30
minutes).
No automatic shut off of the backlight; enter value
“on”.
Temperature display in °C; enter value “ºC”.
Temperature display in °F; enter value “ºF”.
Parameter Description Details
Init Factory settings
Use current configuration; enter value “no”.
Reset device to factory settings; enter value “YES”.
After confirming with the menu button, the display
shows: “Init donE”.
Configuration Menu
Press the button for 2 seconds to open the configuration menu, when “ConF” appears in the
display release the menu button. Use and buttons to change between the different
values.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

ºC
STD
ºC
STD
ºC
STD
6
1
2
3
4
Battery
Battery Indicator
If emty battery blinks in the display, the batteries must be replaced. However, the device will still
operate for a certain length of time.
If the BAT display text appears in the main display, the battery voltage is no longer adequate for device
operation. The battery has to be cahnged to use the device.
Changing Battery
Unscrews the Phillips screws (1) and remove the cover.
Replace the two AA batteries (2). Ensure that the
polarity is correct. It must be possible to insert the
batteries in the correct position without using force.
The O-ring (3) must be undamaged, clean and
positioned at the intended depth.
Fit the cover (4) on evenly. The O-ring must remain at
the intended depth!
Tighten the Phillips screws (1).
Note: If TID is not used for an extended period of time, the batteries must be removed. This will
prevent the batteries from leaking.
Operation
The soldering tip must be properly tinned
before taking a measurement.
Measure Tip Temperature
Solder Aplication
Place the soldering tip in the centre of the
sensor as when soldering. Wait until the
temperature measurement stabilizes.

ºC
STD
7
Note:
If problem is not solved, contact with JBC’s Technical Support at: www.jbctools.com/contact-us
Changing the Sensor
To replace the STD sensor, pull it vertically
out of the sensor stand and replace it with a
new one.
Replacement
Sensor Stand
Ref. 0014847
Sensor
Ref. STD-A
Error Messages
bAt
Display Meaning Possible Causes
Err.1
Remedy
Battery empty. Battery empty. Replace battery.
Measuring range
exceeded.
Measurement too high.
Incorrect measuring probe
connected.
Measuring probe or device
defect.
Stay within allowable
measurement range.
Check TC type.
Contact with technical
service.
Err.2 Measuring range
is undercut.
Measurement too low.
Incorrect measuring probe
connected.
Measuring probe or device
defect.
Stay within allowable
measurement range.
Check TC type.
Contact with technical
service.
SYS Err System error. Error in the device.
Switch device on/off.
Replace batteries and
restart the device.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

8
Maintanance
- Before carrying out maintenance or storage, always allow the equipment to cool down.
- Check periodically that the sensor is clean.
- Use a damp cloth when cleaning. Alcohol can only be used to clean the metal parts.
- Unnecessary unscrewing endangers the protection against moisture and should therefore be
avoided.
- Replace any defective or damaged parts. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
Batteries
- If the device ist not used for a longer periode of time, the batteries must be removed to avoid
leaks of the batteries.
- If the batteries have different charge levels, they may leak and damage the device.
- Do not use different types of batteries.
- Only use high-quality and suitable alkaline batteries.
– Remove depleted batteries immediately and dispose of them at a suitable collection
- Using damaged or unsuitable batteries can generate heat, which can cause the batteries to
crack and possibly explode. Danger of explosion!

9
This device has been designed and tested in accordance with the safety regulations for electronic
devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety
measures and special safety advice in this manual is complied with during use.
- Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected to
any other climatic conditions than those stated under “Specification”.
If the device is transported from a cold to a warm environment, condensation may result in
failure. Should this occur, make sure the temperature of the device has readjusted to the ambient
temperature before trying a new start-up.
- If the digital thermometer is connected to other devices, the circuitry must be carefully designed.
Internal connection to other apparatus (e.g. connection GND/earth) may result in high voltages
which will damage the device(s).
- If there is any risk during use, the device must be switched off immediately and marked
accordingly to avoid being used again.
- Operator safety may be at risk if there is visible damage to the device, the device is not working
as specified or the device has been stored under unsuitable conditions for a long time.
If in doubt, please return the device to the manufacturer for repair or maintenance.
-For professional use. Only used by authorised personnel.
Warning
- Do not use this product as a safety or emergency stop device, or in any other application where
failure of the product could result in personal injury or material damage.
- Do not use the units for any purpose other than measuring cartridge tip temperature.
Working recommendations
- Use a “non residue” classified flux and avoid contact with skin or eyes to prevent irritation.
- Be careful with the remains of liquid tin. In contact with skin, it can cause burns.
- Be careful with the fumes produced when melting soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when
working to avoid personal harm.
Safety
It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

Notes
10

11
Specifications
TID
Digital Thermometer
Ref. TID-B
- Measuring
- Measuring Range: -65 to +1200 °C / -85 to +2192 °F
- Accuracy: ±0.1 % of measuring value
±1 ºC / ±1 º F
- Cold Junction Compensation: ±0.3 °C
- Temperature Drift: ±0.01 % of measuring value/K
±0.025 ºC/K
- Measuring Frequency: 3 measurings per second
- Probe Connection: Type K Thermocouple
- Operating Conditions: -25 to 50 °C / -13 to 122 ºF
0 to 80 %RH (non-condensing)
- Storage Temperature: -25 to 70 °C / -13 to 158 ºF
- Power Supply
- Batteries: 2x AA (mignon)
- Power Requirements: approx. 1mA, approx. 3mA with backlight
- Battery Life: Service life > 2500h with alkaline batteries
(without backlight)
- Battery Indicator: 4-stage battery status indicator
Repalcement idicator “BAT”
- Console Dimensions / Weight: 125 g / 0.28 lb (incl. batteries)
(L x W x H) 108 x 54 x 28 mm / 4.25 x 2.13 x 1.10 in
- Total Net Weight: 766 g / 1.69 lb
- Package Dimensions / Weight: 1276 g / 2.81 lb
(L x W x H) 280 x 280 x 164 mm / 11.02 x 11.02 x 6.46 in
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
be collected and returned to an authorized recycling facility.
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/
within 30 days of purchase.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
0028993-0322
This manual suits for next models
1
Table of contents
Other jbc Thermometer manuals