jcm-tech CONT-R15 User manual

CONT-R15
User Manual

Table of contents
General description 3
Connection 3
Technical characteristics 4
Installation 4
Fitting the casing (only box version) 4
Important considerations for start-up 4
Operating 5
Reference search function 5
Door operation control function with external clock 5
Back Jump Function 5
Option switch 6
Input switch 6
Light indicators 6
Option switch bridging 7
Current limit level switch jumpers 7
Buttons 7
Times 7
Programming 8
Self-prgramming 8
Manual programming 8
Partial opening programming 8
Sensivity programming 8
Parameter configuration from programmer 9
Receiver operations 10
Manual programming 10
Normal programming 10
Programming for pedestrian function 10
Programming by radio 10
Code cancellation (Total reset) 11
Optional cards 11
Receiver card 433MHz / 868 MHz 11
Traffic light card / Flash card (TL-CARD) 11
Traffic light card 11
Flash card 11
Troubleshooting 12
Use of the equipment 12
Regulatory Data 12
EU Declaration of conformity 12
jcmtechnologies
2

General description
Control panel for 24 Vdc motors on sectional, swing, folding and sliding doors for residential and communal use.
Basic features:
Self-programming, stoppage by consumption, receiver incorporated pluggable, resistive safety edge input, encoder input
(sensor hall), slow-speed start of operations, slow-speed end of operations, connection to portable programmer.
Connection
1Primary 230V ac Transformer +
230Vac power supply (L)
924V dc motor 17 Open (OPEN) (NO)
2Primary 230V ac Transformer +
230Vac power supply (N)
10 Encoder (+) 18 Close (CLOSE) (NO)
3Secondary 0V ac Transformer 11 Encoder (S.H.) 19 Common securities
4Secondary 12V ac Transformer 12 Encoder (-) 20 Close security contact (NC)
(SEC.CL)
5Secondary 24V ac Transformer 13 Common buttons 21 Resistive security edge 8K2
(S.EDGE)
624V ac output 14 Stop (STOP) (NC) 22 Common ends of run
724V ac output 15 Start (START) (NO) 23 End of run close (NC) (FC.CL)
824V dc motor 16 Common buttons 24 End of run open (NC)
(FC.OP)
jcmtechnologies
3

Technical characteristics
Parameter Value
Panel supply 0-12-24Vac
Transformer 0-12-24Vac / 100VA or 150VA
Receiver 868,35MHz incorporated 15 codes / 433.92 / 868.35 MHz pluggable
(depending on version)
Optional cards Pluggable receiver card (433,92 (bi-channel) / 868,35 MHz) and traffic
light card (TL-CARD)
Security device output 24V ac / 400mA
Operating temperature -20ºC to +85ºC
Watertightness IP54
Equipment category Class II
Base plate size 160x83x27 mm
Box size 225x195x85 mm
Installation
Disconnect the power supply whenever you proceed to the installation, main-
tenance or repair of the equipment.
Fitting the casing (only box version)
•Parts: front casing and container box.
•Unscrew the securing points. Insert the cables through the lower holes.
Important considerations for start-up
Where inversions are made, the panel adds time to ensure the door closes.
Any optional cards must be connected to the panel with the power supply disconnected.
jcmtechnologies
4

Operating
Start
Contact normally open to open and close. First time the button is pressed, it
opens; the second time (if it has not reached the end of the run), it stops and
the third time it closes. If it is pressed while the door is closing, it will stop and
invert the operation
Stop (STOP) Contact normally closed. This detains the operation on standby for a new
order. Where not used, turn option 1 on the input switch to ON
Open (ABR.) Contact normally open to open. If it is pressed while the door is closing, it will
stop and open
Close (CER.) Contact normally open to close. If it is pressed while the door is closing, it will
stop and close
Security contact (SEC.CL)
Contact normally closed, photocell or magnetic detector type. This acts on
opening and closing, causing stoppage and inversion. Where not used, turn
option 2 on the input switch to ON
Security edges (S.EDGE)
Resistive contact for two parallel resistive security edges. This acts on clos-
ing, causing stoppage and inversion. Where not used, turn option 3 on the
input switch to ON. Where option 6 of the options switch is turned to ON, the
band is inhibited during the last 4 cm of door closure
Ends of run (FC.CL/FC.OP) Contacts normally closed to mechanically indicate the open and closed end
of run. Where not used, turn option 4 or 5 on the input switch to ON
24 Vac output To power any equipment at a voltage of 24 Vac with a maximum con-
sumption of 400 mA
Encoder input (+, S.H., -) Allows for an NPN-type encoder (or sensor hall) to be connected at 5 Vdc,
necessary for the operation by pulses.necessary for the operation by pulses
Reference search function
If the panel loses power halfway through the operation, on receiving power it goes into reference search mode, in such a way
that the door will move until a mechanical stop or the end of the run is reached, with preference given to the opening reference,
if it exists. Reference search is indicated by the corresponding flashing of the SAFETY light (see table).
The Aut ref Search parameter (configurable by means of programmer) is selected if the user requires this automatic search or
wishes to wait for the START button to be pressed for the reference search.
The panel may lose the reference if the power is disconnected halfway
through the operation.
Door operation control function with external clock
By connecting an external clock or timer (normally open) between the common push button terminal (16) and the bridged Open
and Close terminals (17 and 18), it is possible to temporize the opening and closing of the door.
Back Jump Function
With this function, the panel causes a small delay in the door at the end of the operation to prevent voltage in the mechanism
or to avoid pressure on the safety edge, where applicable. The time of the delay can be defined using advanced programmer
parameters.
jcmtechnologies
5

Option switch
Option No. Upper position – ON Lower position - OFF
1 (AUTO PROG) Self-programming Manual programming (default
option)
2 (AUTO CLOSE.) Automatic closure Does not close automatically
(default option)
3 (NON STOP ON OPENING) Does not allow for radio reverse on
opening
Allows for radio reverse on opening
(default option)
4 (SLOW) Allows for slow speed (default
option) Does not allow for slow speed
5 (COURTESY L / ELECT)
Garage light comes on (default
option). Garage light contact time =
Operating time + 30 seconds.
Works like an electro-lock (1.5
seconds before opening)
6 (INH.SEC.EDGE 4cm) Inhibits the security edge for the last
4 cm of the run
Does not inhibit the security edge
(default option)
7 (DEAD MAN) Dead-man operations Semi-automatic or automatic oper-
ations (default option)
Input switch
Option No.
Upper position – ON (default
option) Lower position - OFF
1 (STOP) Stop button not connected Stop button connected
2 (SEC.CL.) Security Close contact not con-
nected Security Close contact connected
3 (S.EDGE) Security edge not connected Security edge connected
4 (FC.CL.) End of run close not connected End of run close connected
5 (FC.OP.) End of run open not connected End of run open connected
Light indicators
Function Indicates Default status
POWER Power Normally on
SAFETY Operating alert (see table) Normally off
ERROR Operating fault (see table) Normally off
TIMER PROG. Operation programming mode Normally off
RADIO PROG. Radio programming mode Normally flashing
jcmtechnologies
6

Option switch bridging
JP1 Integrated radio disconnection (where a pluggable receiver card is used, the cut bridge provides
greater range)
JP2 Pedestrian channel disconnection of the pluggable receiver card (where a single-channel
RACK+DCS is used, this bridge must be cut)
JP3 Select if the programming is carried out by pulses or by time. With the jumper at ON the panel will be
programmed by pulses and with the jumper removed it will be programmed by time.
Current limit level switch jumpers
JP4 at ON Normal level of current limit
JP4 cut off High level of current limit
Buttons
START Start
TIMER PROG. Start pulse or time programming
RADIO PROG. Start transmitter programming
Times
Controlling Minimum Maximum
Motor operating 3s 10min
Wait for automatic close 3s 10min
jcmtechnologies
7

Programming
•If stoppage is required during programming, the control panel exists programming automatically for safety reasons.
•Before starting any type of operation programming, the corresponding options must be correctly selected (option switch, input
switch and option switch bridging) and the safety elements must be connected, where applicable.
•Operations can be programmed indifferently using the TEST / START button or through a previously programmed transmitter.
•If in programming mode for 30 seconds without programming, the equipment will exit programming mode and the TIMER
PROG. led will switch off.
Self-prgramming
Press the TIMER PROG button to enter programming. The TIMER PROG. led with light up. Use the TEST or the START but-
ton or a transmitter to start programming the run. After the button is pressed for the first time, the door will open slowly (if
option 4 of the options switch is turned to ON) until a mechanical stop is reached or the Open limit switch is enabled. It will then
close until it reaches a mechanical stop or the Close limit switch is enabled. Immediately afterwards, the panel begins to oper-
ate, carrying out all of the operations programmed and memorising the consumption of the runs. Once consumption mem-
orising is complete, the TIMER PROG led will switch off.
The panel is programmed with the following fixed parameters: Slow-speed operations are 15 % of total operations, partial open-
ing is equivalent to 2/3 total opening and the automatic closure standby time is 30 seconds (total opening and partial opening).
Where limit switches or mechanical stops are not used on either of the two ends of the door, the
START button must be pressed to indicate the limit of the run at the end of the door without the
limit switch or mechanical stop.
Manual programming
Press the TIMER PROG button to enter programming. The TIMER PROG. led with light up. Use the TEST or the START but-
ton or a transmitter to programme the run. The first time the button is pressed, it opens. After the button is pressed for the
second time, the opening movement will slow down (if option 4 of the options switch is turned to ON) until a mechanical stop is
reached or the Open limit switch is enabled and the automatic standby timer will begin. The third time it is pressed, it stops the
automatic standby timer and closes. After the button is pressed for the fourth time, the closure movement will slow down (if
option 4 of the options switch is turned to ON) until a mechanical stop is reached or the Open limit switch is enabled. Imme-
diately afterwards, the panel then begins to operate, carrying out all of the operations programmed and memorising the con-
sumption of the runs. Once consumption memorising is complete, the TIMER PROG led will switch off.
Where limit switches or mechanical stops are not used on either of the two ends of the door, the
START button must be pressed to indicate the limit of the run at the end of the door without the
limit switch or mechanical stop.
Partial opening programming
In programming, use the second recorded transmitter channel button to programme partial opening. Then programme as
required using the steps described above.
Sensivity programming
The control panel must be installed on the door and the operation programmed correctly to programme sensitivity. Follow the
steps below:
jcmtechnologies
8

1. Press the programming button for more than 10 seconds until the safety led (or error led, depending on the model)
flashes.
2. Release the programming button. The safety (or error) led will flash between 1 and 10 times. This is the sensitivity level
selected (crush prevention). 1 indicates very sensitive (little crushing force) and 10 indicates very insensitive (a lot of crush-
ing force). See table.
3. On pressing the START button, the sensitivity level will increase by one to give a stronger crushing force. If pressed again on
reaching level 10, it will return to level 1.
4. Press the PROG button to exit sensitivity level programming mode.
No. of flashes Crushing force (sensitivity margin) (approx. percentage)
1 10% (minimum)
2 20%
3 30%
4 40%
5 50%
6 60%
7 70%
8 80%
9 90%
10 100% (maximum)*
* Attention! It may not detect obstacles in some cases
Parameter configuration from programmer
There are different parameters that can be configured by portable programmer. Below is a description of the most basic. Refer
to the programmer instruction manual for further information.
Operation by Time Indicates if the panel is programmed to operate by time
Operation by Pulses Indicates if the panel is programmed to operate by pulses
Oper. counter limit Indicates / selects the limit number of operations for the panel
Operation counter Indicates the number of operations made to date
Autoclosing time Indicates / selects the seconds of automatic standby time
Equip. Shows an equipment identifier
Low speed starting
open Indicates / selects slow speed at start of opening operation
Low speed starting
clos. Indicates / selects slow speed at start of closing operation
BackJump Open Indicates / Selects the back jump function for the opening operation
BackJump Close Indicates / Selects the back jump function for the closing operation
Last 4cm inh. space Indicates / selects the seconds or pulses equivalent to 4cm of distance for the disa bling
of the security band
Sec. C. Close Indicates whether the panel allows for security contact closure
Time-only close Indicate / select if the door can be time-closed. If the Sec. C. Close parameter is
enabled, closure through activation of the security contact is also possible
jcmtechnologies
9

Receiver operations
Upon receiving a code, the equipment checks whether it is in its memory, activating the corresponding relay.
Manual programming
Normal programming
Press the RADIO PROG programming button for 1 sec. The programming RADIO PROG pilot light will come on and the equip-
ment will emit an acoustic signal. The equipment will enter normal programming. Send the code and the channel to be pro-
grammed by pressing the transmitter.
Every time a transmitter is programmed, the equipment will issue an acoustic signal for 0.5 sec. After 10 seconds without pro-
gramming or by pressing the programming button, the equipment will exit programming mode, issuing two 1 sec. acoustic sig-
nals. If, on programming a transmitter, the equipment memory is full, it will issue seven 0.5 sec. acoustic signals and exit
programming.
By pressing the transmitter channel, opening and closure is activated in automatic operating mode.
Programming for pedestrian function
In normal programming, press the RADIO PROG programming button again and keep it pressed down until the RADIO PROG
pilot light flashes and the equipment emits a short acoustic signal. The equipment will now have entered programming for ped-
estrian function. Press the required channel of the transmitter to be programmed. The first channel opens and the second
closes (3rd channel opens and 4th channel closes).
Every time a transmitter is programmed, the equipment will issue an acoustic signal for 0.5 sec. After 10 seconds without pro-
gramming or by pressing the programming button, the equipment will exit programming mode, issuing two 1 sec. acoustic sig-
nals. If, on programming a transmitter, the equipment memory is full, it will issue seven 0.5 sec. acoustic signals and exit
programming.
Each transmitter channel can be configured independently on the equip-
ment, occupying only one memory position.
Programming by radio
To enter programming, press the first two buttons on a transmitter that has already been registered on the equipment. The
equipment will issue a 1 sec. acoustic signal. On pressing any button on the new transmitter, the equipment will issue another
1 sec. acoustic signal to indicate that it has been memorised. The new transmitter will maintain the same channel con-
figuration as the transmitter registered.
After 10 seconds without programming or by quickly pressing the programming button or pressing the first two transmitter but-
tons, the equipment will exit programming mode, issuing two 1 sec. acoustic signals.
jcmtechnologies
10

Code cancellation (Total reset)
In programming mode, the programming button is held down and the “MR” reset jumper is bridged for 3 secs. The equipment
will issue 10 short acoustic warning signals followed by others at a faster pace to indicate that the operation has been suc-
cessful. The equipment is now in programming mode. The pilot programming light will also follow the acoustic indications by
flashing.
After 10 seconds without programming or quickly pressing the programming button, the equipment will exit programming
mode, issuing two 1 sec. acoustic signals.
Optional cards
Receiver card 433MHz / 868 MHz
This acts on the panel with transmitters, proximity keys or smart cards in the same way as the start button.
Traffic light card / Flash card (TL-CARD)
Traffic light card
This carries out two different functions according to the outlets:
Outlet 1 signal
Outlet 2 courtesy light contact; it operates during all the operating time plus 30 seconds. If option 5 of
the option switch is turned to OFF, it will carry out the function of an electro-lock
Outlet 3 and 4 traffic lights. Outlet 3 activates the red traffic light that works during door movement. Outlet 4
activates the green traffic light that is only lit when the door is fully open
Flash card
Of door movement through the contact of a relay intermittently activated.
The traffic light selector carries out no function.
jcmtechnologies
11

Troubleshooting
The following table indicates the possible causes of operating failures in the control panel through the ERROR and SAFETY
LEDs.
Code ERROR led SAFETY led Description
255 on on Stop enabled
17 1 flash 1 flash Security band enabled
34 2 flashes 2 flashes Safety contact enabled
16 off 1 flash Excess consumption on closure
32 off 2 flashes Excess consumption on opening
48 off 3 flashes Panel programmed by times
64 off 4 flashes Panel not referenced or waiting to start reference search
1 1 flash off Security band not connected
2 2 flashes off Maximum current limit exceeded
3 3 flashes off End of run or programmed reference not reached
4 4 flashes off No encoder pulses
5 5 flashes off Panel programmed without references
6 6 flashes off Internal error
Use of the equipment
This equipment is designed to automate garage doors following the general description. It is not guaranteed for other uses.
The manufacturer reserves the right to modify equipment specifications without prior notice.
Regulatory Data
EU Declaration of conformity
JCM TECHNOLOGIES, S.A. hereby declares that the product CONT-R15 complies with the relevant fundamental require-
ments of the RED Directive 2014/53/EU, as well as with the Machine Directive 2006/42/EC whenever its usage is foreseen;
and with the 2011/65/EU RoHS Directive.
See website www.jcm-tech.com/declarations/
JCM TECHNOLOGIES, SA
C/COSTA D'EN PARATGE, 6B
08500 VIC (BARCELONA)
SPAIN
jcmtechnologies
12
UM_3201356_CONT-R15_EN_Rev00
Table of contents
Other jcm-tech Control Panel manuals
Popular Control Panel manuals by other brands

Swegon
Swegon CASA Smart Sensor Installation

Honeywell
Honeywell Symphony Frequently asked questions

Victron energy
Victron energy Skylla-i Control GX manual

Beckhoff
Beckhoff CP29xx-0000 Series Installation and operating instructions

RCS
RCS UPM-421 operating instructions

SLEIPNER MOTOR AS
SLEIPNER MOTOR AS 8700 installation guide