Programming
•If stoppage is required during programming, the control panel exists programming automatically for safety reasons.
•Before starting any type of operation programming, the corresponding options must be correctly selected (option switch, input
switch and option switch bridging) and the safety elements must be connected, where applicable.
•Operations can be programmed indifferently using the TEST / START button or through a previously programmed transmitter.
•If in programming mode for 30 seconds without programming, the equipment will exit programming mode and the TIMER
PROG. led will switch off.
Self-prgramming
Press the TIMER PROG button to enter programming. The TIMER PROG. led with light up. Use the TEST or the START but-
ton or a transmitter to start programming the run. After the button is pressed for the first time, the door will open slowly (if
option 4 of the options switch is turned to ON) until a mechanical stop is reached or the Open limit switch is enabled. It will then
close until it reaches a mechanical stop or the Close limit switch is enabled. Immediately afterwards, the panel begins to oper-
ate, carrying out all of the operations programmed and memorising the consumption of the runs. Once consumption mem-
orising is complete, the TIMER PROG led will switch off.
The panel is programmed with the following fixed parameters: Slow-speed operations are 15 % of total operations, partial open-
ing is equivalent to 2/3 total opening and the automatic closure standby time is 30 seconds (total opening and partial opening).
Where limit switches or mechanical stops are not used on either of the two ends of the door, the
START button must be pressed to indicate the limit of the run at the end of the door without the
limit switch or mechanical stop.
Manual programming
Press the TIMER PROG button to enter programming. The TIMER PROG. led with light up. Use the TEST or the START but-
ton or a transmitter to programme the run. The first time the button is pressed, it opens. After the button is pressed for the
second time, the opening movement will slow down (if option 4 of the options switch is turned to ON) until a mechanical stop is
reached or the Open limit switch is enabled and the automatic standby timer will begin. The third time it is pressed, it stops the
automatic standby timer and closes. After the button is pressed for the fourth time, the closure movement will slow down (if
option 4 of the options switch is turned to ON) until a mechanical stop is reached or the Open limit switch is enabled. Imme-
diately afterwards, the panel then begins to operate, carrying out all of the operations programmed and memorising the con-
sumption of the runs. Once consumption memorising is complete, the TIMER PROG led will switch off.
Where limit switches or mechanical stops are not used on either of the two ends of the door, the
START button must be pressed to indicate the limit of the run at the end of the door without the
limit switch or mechanical stop.
Partial opening programming
In programming, use the second recorded transmitter channel button to programme partial opening. Then programme as
required using the steps described above.
Sensivity programming
The control panel must be installed on the door and the operation programmed correctly to programme sensitivity. Follow the
steps below: