Jinko JK3000-8 User manual

1

2
Multicahnnel temperature
recording (test) instrument
An instruction manual
Vear1.0

1
Catalog
Chapter one
Safety and warranty...................................
Introduction of instrument ...........................
Application ..........................................
Chapter two General overview of temperature recorder .............
Difference of temperature recorder ...................
Chapter three fast introduction.....................................
Introduction of product front panel...................
Display and function key introduction.................
Product rear panel introduction.......................
Parameters setting....................................
Chapter four Installation and accessories..........................
Chapter five communication.........................................
Communication protocol................................
Software operation interface..........................
Chapter six verification or calibration...........................

2
Preface
Summary
The new multi-channel temperature recorder has ultra-thin chassis, light weight, small volume
and easy to carry.
At the same time, the digital synchronous sampling technology has the advantages
of fast measuring speed, high precision, easy to use, light and beautiful and so on. The instrument test
precision is 0.5. This product is widely used in scientific research colleges and universities, electric
power, chemical industry, petroleum, steelmaking, glass, ceramics, heat treatment and plastic, rubber,
printing and dyeing, packaging and food machines. Temperature measurement and temperature
control in the machinery industry.
The disposal of old packaging boxes and the disposal of old packaging boxes should be
carried out in accordance with relevant national environmental regulations.
Please pay attention to separate the plastic and paper packaging products.
Maintenance of the instrument
◆The surface of instrument should be dust in time,The interior of the instrument is best not to
accumulate dust.
◆The instrument should be calibrated once a year, so as to ensure the accuracy of the
instrument, so that it can be used normally.
Warning: be sure to disconnect the power before cleaning.
Announcement
The contents of this manual are subject to change without notice. Excuse me!

3
Chapter one
Security
Do not install on your instrument instead of parts, or execute any unauthorized
modification.Please send the instrument to the maintenance department of the company to
maintain it, so as to ensure its safety characteristics.
Security rules
In order to prevent electric shock, not authorized personnel of the company, it is strictly
forbidden to disassemble the instrument and strictly prohibit the use of the equipment on the
life maintenance system or any other equipment with safety requirements.We are not
responsible for direct or indirect financial losses that may occur when using this product.
Certification and quality assurance
The multichannel temperature recorder has achieved all the technical indicators mentioned
in the manual.
warranty
The company of materials and manufacturing of this product, from the date of shipment to
the quality warranty for one year.
Warranty service
If you need the product warranty service or repair, must be the product to the maintenance
unit. The customer must pay the one-way freight to the maintenance department, and the
company will be responsible for paying the return freight. If the product is returned to factory
maintenance from other countries, all freight, duties and other taxes shall be borne by the
customer.
Guarantee restriction
The warranty does not apply to the damage caused by the following circumstances:
The customer is incorrect or improper in repairing products.
Customers use their own software or interface;
Unauthorized modification or misuse;
Operating this product or not in the specified environment or repair and repair at unsuitable
places,Damage caused by the circuit of the customer's own installation.Or a defect caused by
a customer's use of its own product.

4
Brief introduction
JK3000 is a high performance, low price temperature recorder. It can watch multi-channel
temperature changes at the same time.It is very suitable for application of temperature
acquisition and temperature recording.It has the RS232 interface to upload data directly to the
PC, and also has the USB interface to save the measured data directly to the U disk when it is
inconvenient to connect to the PC, and then transfer the data to the PC when needed.It is a half
frame wide host with a top 64 channel direct slot on the back of which can be measured with a
thermocouple, and 1 infinite expansion slots, which can be assembled by a module.Whether
you need only a few simple data recording channels or hundreds of thousands of performance
channels, you can meet your temperature collection at a reasonable price.
3 different types of thermocouple measurement
Measurements that can be dependent on the temperature recording software
The unique design allows every 8 channels to be configured for a single unit, so as to
achieve maximum flexibility and quick and convenient setting of automatic range conversion
inside. That is to say, choose 1-8 as K type thermocouple, 9-16 as J type thermocouple, and
change configuration according to needs.
Here are 64 direct access slots and 1 infinite expansion slots on the back to meet your
unique needs. You can only buy the parts you need at that time, and then add more modules
as your application develops. 1.5 rack units can be used to measure up to hundreds of
thousands of inputs.
Free software simplifies data acquisition
If we require data recording capability based on PC, but we don't want to spend time
programming, software can solve this problem. With this software, you can set up your test,
collect and archive, manage and measure data, and display and analyze the data and curves in
real time. The familiar electronic table environment can be easily configured and controlled for
testing. Rich color graphics provide many options for displaying your data. In addition, using
software can easily send data to other applications for further analysis, or include it in your
display and report.
A brief introduction to the module
The module can be directly used to connect the infinite expansion slot to the back of the
instrument and connect the thermocouple line.
When you need more modules, you only need to connect to the reserved slot of the first
module.(this function is especially practical when the instrument and the need to be far away
from the measured point, not only can reduce the measurement accuracy caused by too long
thermocouples, but also save the large amount of money cost needed for the purchase of
thermocouples).

5
application
Instrument safety index
◆Insulation resistance: the outer part of the housing and the power input are larger than
20MΩ.
◆Withstand voltage: the power input terminal and the housing are 2 seconds withstanding
voltage 1800V, and the rated current is 10mA.
◆Grounding: the power grounding pole, and the resistance between the outer shells is less
than 0.2Ω。
◆security: conforms to CSA,UL-1244,IEC1010 Cat I regulations RFI and
ESD:CISPR11,IEC801/2/3/4
Precautions before use of the instrument
◆The instrument should be placed smoothly And where the dust is less.
◆The temperature conditions that ensure the accuracy of the test:20℃±5℃。
◆Working temperature range:0~40℃,Air relative humidity:30%~90%。
◆No corrosion, detonable gas in the room.
◆Protect ground.
◆Power supply: AC90-240V/50/60HZ,Power waste ≤15W。
◆Fuse:is 0.5A
◆weight :Net weight 3.6kg
◆accuracy :±0.3%(the highest temperature measured at the time)
When using the "T" thermocouple, the accuracy can reach as high as 0.1%.

6
Chapter two
A list of functional difference of each thermometer
Serial
numbe
r
Model
The largest
number of
channel
temperature
range①
U DISK
②
RS232
communication
interface
1
JK3000-8
8
3 kinds of
thermocouples
yes
yes
2
JK3000-16
16
3 kinds of
thermocouples
yes
yes
3
JK3000-24
24
3 kinds of
thermocouples
yes
yes
4
JK3000-32
32
3 kinds of
thermocouples
yes
yes
5
JK3000-40
40
3 kinds of
thermocouples
yes
yes
6
JK3000-48
48
3 kinds of
thermocouples
yes
yes
7
JK3000-64
64
3 kinds of
thermocouples
yes
yes
The specification and measurement range of the S series input type
Input type
Specifications
measuring range
Thermocouple
J
-200~1200℃
K
-200~1370℃
T
-200~400℃
technical parameter :

7
3 kinds of thermocouples in the table ①,3 different types of thermocouples The range of
temperature is:
Model
multichannel temperature tester
Input type
Thermocouple:J/K/T
measuring
range
Measuring range:-200℃~1760℃J,K,T,
measurement accuracy:0~1000℃:±(reading value×0.5%+1)℃,-100~
0℃:±(reading value×0.5%+2)℃;
Number of
channels
8,16,24,32,40,48,64 channels
Display
480*272 5 inch TFT color screen
Display
resolution
1mV 0.1℃
U disk storage
yes
scanning speed
100ms
Internal storage
yes
Curve portrayal
yes
communication
interface
RS232 or USB
software kit
2015 version of V1.3 software
Alarm mode
One way public alarm (relay output).(selection)
Voltage output
Internal independent power supply output
Anti-
interference
Anti high frequency interference
Single screen
display
32 channel
Temperature
correction
yes
Other functions
Clock function ,calendar function
Terminal type
M3 screw type
Permissible
environmental
conditions
1、Power supply:AC 220V±10%,50Hz±2%;
2、Working environment: working temperature:-20-70℃,relative humidity:20%
-90%;
Measuring
range
J type: -50.0℃~ 1000.0℃
K type: -50.0℃~ 1200.0℃
T type: -50.0℃~ 400.0℃
attachment
Standard: K type thermocouple 8 (2 meters / root) data acquisition software.
Size
Length * width * height: 36cm * 26cm * 16cm weight: About 5kg

8
J thermocouple
0~760℃
K thermocouple
0~1370℃
T thermocouple
-100 ~400℃
U disk: the instrument does not connect to PC. It can store data on the U disk, and save data
permanently in the computer by transferring data.
The 3000-8 in Table 8 is that the acquisition module with 8 channels can be used in conjunction
with each of the above instruments. After the customer has purchased any instrument, if you want
to increase the acquisition channel, the 8 channel can choose 108 modules for one unit.
In table 10, 3000+108 indicates that customers can choose how many channels to collect
temperature according to their needs and choose a 108 acquisition module with 8 channels as a
unit in the case of a host. If you need 80 channels, you can choose a 64 way host and 2 108
acquisition modules.

9
Chapter three
Product introduction
front panel
Introduction of front panel
1:display screen
2:power
3:System function key
4:USB disk interface
5:Qualified / unqualified
6:Lock key
7:Digital keyboard
8:Cursor key
9:show key

10
Display area schematic:
1:Show the temperature of each channel, respectively(001 represents first channels, 002
represents second channels), and so on.
2:Display date / time: as shown in the picture 1th January,2007,At 20:26 00 seconds
3:Thermocouple model
4: Unit of temperature

11
Rear panel schematic:
As shown in the picture.
1:Indicating the interface definition of each channel number and input signal(01 represents 1
channels, 02 represents 2 channels, and so on.)
Signal wiring method:
Thermocouple Thermal resistance voltage current
Signal access Signal access Signal access Signal access
2:The input voltage of the power outlet is AC220V 50Hz 0.5A
3:The USB interface is used for computer USB port connection (RS232 and USB choose one).
4:The RS232 interface can directly upload the data measured to the PC through the RS232
cable line and the host computer software (RS232 and USB choose one).
5:CASCADING: Used for channel expansion and alarm relay contact output terminal, when
alarm relay output, contact signal as shown in the figure:
2,3 are normally closed contacts
3,4 are normally open contacts

12
Contact load capacity is DC 24V/1A
Channel setting :
1、Select the required setup items, press the "parameter settings" key, and use the "up
and down" key to set the value or function.For example, setting the number of channels: after
moving the cursor to the number of channels, press the key of "parameter", change the
parameters with "up and down" key, then press the "set to finish" button.
2、Type setting of thermocouple: move cursor to the type of thermocouple, select
thermocouple type with "up and down" key, and press "set up" to exit.
3、The other projects are like this,
When the settings are completed, press "MENU" to save the settings and exit; press
the exit key, do not save the settings and exit.
Equipment parameter page introduction:
Channel number: number of test instruments
Baud rate: communication rate between instrument and host computer
Device address: the host computer inquires the address of the machine
Sampling time: speed of reading temperature and data
Unit of temperature: a unit of temperature:(℉,℃)
Automatic screen change: when the number of passages exceeds 32, the temperature needs
multi page display.
Multi page automatic rotation display at ON

13
Temperature rise: no function at present
Time setting: instrument clock
Buzzer alarm: the buzzer opens or closes the choice
Power saving: no function at present
Upper limit alarm value: high temperature alarm value. Every 8 channels is an adjustment base,
and can be switched through thermocouple type.
The lower limit alarm value is low temperature alarm value. Every 8 channels are adjusted base
and can be switched through thermocouple type.
Reference value: no function at present
CJC calibration: adjust the channel deviation value, each 8 channels as an adjustment base.
Type of thermoelectric coupler: Type: choose the probe type of the instrument test, each 8
channels as an adjustment base.
Functional selection:
1. When displaying the channel parameters, press the "MENU" button to switch to the
digital bar.Then, through the upper and lower keys to adjust the number you need, and then
switch to the next digit through the left and right keys.When the settings are completed, press
"MENU" to save the settings and exit; press the exit key, do not save the settings and exit.。
2. Baud rate :1200 ,2400 ,4800 ,9600 ,19200 ,38400 According to your different
needs, you can set it on your own. The default is 9600 when you start the machine.
3. Device address: according to the COM port of different PC, that is to choose to several.
The default is 001.
4. Sampling time: how long is it needed to collect, how long it takes to tune up, the
minimum time is 1 second, the maximum is 9999 seconds.
5. Temperature unit:℃/℉Switch.
6. Automatic screen switching:ON/OFF Switch.
7.Time settings: set the year, month, hour, minute and seconds that you need to display.
8. Buzzer alarm: when the temperature is adjusted to "ON", if the temperature exceeds the
upper limit or lower limit set by you, there is a sound of sound. If it is adjusted to "OFF", there is
no sound hint.
9. In the measurement, you can set an upper limit of temperature and a lower limit of a
temperature. When the measured temperature exceeds the range you set, if the buzzer alarm is
in the "ON" state, there will be a sound warning to you. The "+" on the display represents the
positive temperature "-" representing the negative temperature.
10. Type of thermocouple: it can be arranged from 8 to one, and different thermocouple
types are set for a unit.

14
11. After all settings are finished, press "set up" to exit the parameter settings.
Curve parameter page introduction:
At any interface, just press the "DISP" button to return to the measurement display interface.
According to the "graph" key, the curve display interface is displayed, as shown in the figure.
According to the "curve setting" key, enter the "curve setting" display interface, as shown in the
figure.
X axis length: X axis time value, 1min~999min can be set freely.
Y axis range: Y axis temperature range, -1999~+1999,If you want to set negative numbers,
you need to make sure that when the number is not 0 Change+/-.
X axis grid number: X axis grid number, 1~9 can be set freely.
Y axis grid number: Y axis grid number, 1~9 can be set freely.
Background color: curve background color value, 000~255 can be set freely.
Raster color: curve grid line color, 000~255 can be set freely.

15
Font color: the color of the word on the curve page, 000~255 can be set freely.
Curve color: set the color value of each channel curve, 000~255 can be set freely.
Channel display: channel curve opening and closing settings, 0 passes, 1 open, every 8 channels
is a set base.
Introduction of function settings interface
At any interface, just press the "DISP" button to return to the measurement display interface.
Press the function setting key to enter the function setting interface, as shown in the figure.
Language: language includes two languages, Chinese and English.
Set steps: the cursor area moves to Chinese and English, click the "parameter setting" key, switch
the language, click "set up" key, if you need to cancel the setting, click "cancel the setting" key.
Storage mode: U disk storage and internal storage of 2.
Introduction of Function setting interface
At any interface, just press the "DISP" button to return to the Function setting interface.
According to the U disk , you can enter the Function setting interface, as shown in the figure.

16
Press the up and down button to select the U save and click Set End .
system information
The system information interface includes:
Instrument model
Software version
Hardware version
Date of manufacture
Instrument number

17
Chapter four
install
Make sure that you receive the following components when you receive multiple
temperature records. If there is any shortage, please contact your dealer as soon as
possible.
Chapter five: instrument communication
Communication interface reference for multichannel temperature recorder
To facilitate users, there are two optional interfaces for instrument communication: RS232
interface (DB9 port) and USB port.
Baud rate: range 1200 - 38400
Instrument communication data format: 1 start bits, 8 data bits, 1 stop bits (corresponding to 8051,
8096 serial mode 1).
Serial connection:Standard RS 232 level, DB9 pin definition,2 - RXD, 3 - TXD, 5 - GND
USB communication interface: the inside is a 232 turn USB module, and the outlet is located on
the back side of the instrument (the front panel is the U disk socket).
Power line (one)
JK-E171
JK-E172
JK-E173
JK-E174
Users can choose different power
lines according to the specifications of
the power outlets in the area.
one
User's Manual
Including the installation of information,
operation information
one
Software CD-
ROM
Software and technical information
one
Test Report
Test report on the instrument before the
factory
one
U disk
RS232 Cable
JK-R1
one

18
USB communication requirements: we need to install USB driver software on the U disk to be
used.
Connect with the computer: connect the USB communication line with the instrument to the
computer USB port. After the USB driver is installed, the computer will detect the USB
communication interface of the instrument. The resource manager can check the port number,
and the port number of the communication software can be communicated to the secondary port
number.
Instrument communication command:
1,Start a real time acquisition handshake :01 11 c0 2c
01 Instrument address,11 command,C02c is the CRC check value.
Instrument return:01 11 0a 49 44 41 51 38 35 31 38 30 30 5b d6
5bd6 is a CRC check value
2,Reading upper and lower limits:01 03 00 50 00 03 05 da
05da is a CRC check value
Instrument return:01 03 06 00 01 00 32 00 0b fc bd
0001 represents the first set of parameters, the upper limit of 0032, and the lower limit of 00
0b.fcbd is a CRC check value
3,Read the data:01 03 00 00 00 50 45 f6
50 Data length,45 f6 is a CRC check value
return:01 03 a0 00b4 00b5 00b3………………CRC
The data is 2 bytes with a symbol number, a decimal point
4,Write set data 01 10 00 50 00 03 06 00 01 00 32 00 0b 38 09(CRC)
The 03 is 3 sets of data, 06 is 6 bytes, 0032 is the upper limit value, the 000b lower limit value.
The data is 2 bytes with symbols, no decimal point.
Software operation interface
1, after ensuring the connection of RS232 communication cables between PC and instruments,
After installing the software provided by our company, click on the JK5080 icon and you will enter
it. In the "File" column, click on the " " Select the save path:
This manual suits for next models
6
Table of contents
Other Jinko Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Signal Hound
Signal Hound SM200C Configuration guide

Flexim
Flexim FLUXUS WD Operating instruction

Geist
Geist Watchdog 15 Series instruction manual

Lovibond
Lovibond TR 515 Operator's instruction manual

Commercial Electric
Commercial Electric MS8301A Use and care guide

Geometrics
Geometrics Memory-Mag G-856AX Operation manual