JNF IN.21.900 User manual

MANUAL DE INSTALAÇÃO / INSTALLATION MANUAL / MANUAL DE INSTALACION
IN.21.900
LOCKING SYSTEMS
AUTOMATIC OVERHEAD DOOR CLOSER
MOLA DE PORTA AEREA AUTOMATICA
CIERRA PUERTAS AEREO AUTOMATICO

WARNING
IT MIGHT CAUSE DAMAGE TO THE PROPERTY OR INJURY TO THE USER UNDER THE INCORRECT USAGE.
IT MIGHT CAUSE A SERIES INQUIRY OR DEATH UNDER INCORRECT USAGE.

INSTALLATION MANUAL / MI0315.1 www.jnf.pt 3/72
1. GENERAL SAFETY INSTRUCTION
1.1. INTRODUCTION
1.2. OVERVIEW
1.3. GENERAL NORMS
1.4. WARRANTY
1.5. DISPOSAL AND RECYCLING
2. PRE-INSTALLATION
2.1. INSTALLATION REQUIREMENTS
3. TECHNICAL DATA
3.1. FEATURES
3.2. TECHNICAL DATA
3.3. DIMENSIONS
3.4. COMPONENTS
3.5. OPTIONAL ACCESSORIES
3.6. MECHANISM COMPONENTS
4. MECHANICAL INSTALLATION
4.1. BAR TYPE
4.1.1.
4.1.2.
4.2. INSTALLATION OF BOTTOM PLATE
4.2.1. PULL BAR
4.2.2. PUSH BAR
4.3. INSTALLATION OF SLIDING ARM
4.3.1. PULL BAR
4.3.2. PULL BAR FOR GLASS DOOR
4.3.3. PUSH BAR
4.3.4. PUSH BAR FOR GLASS DOOR
4.4. MECHANISM INSTALLATION
4.5. ASSEMBLE AND DISASSEMBLE OF THE MECHANISM UP COVER
5. WIRED DIAGRAM
5.1. TERMINAL DETAILS
5.2. INTERLOCK
5.3.
5.4. DIFFERENT SENSOR EXAMPLE
5.5.
5.6. MAGNETIC LOCK
5.7.
5.8.
6. REMOTE CONTROL
6.1. OPERATION OF THE REMOTE CONTROL
7. DATA SETTING
8. LED DISPLAY FEEDBACK
8.1. SINGLE OPENING
8.2. DOUBLE OPENING
9. TROUBLESHOOTING
04
04
04
04
04
05
05
06
06
07
07
08
09
09
09
10
10
11
12
12
13
13
14
16
16
17
18
18
19
19
19
20
20
21
22
22
22
23
CONTENTS EN

INSTALLATION MANUAL / MI0315.1 www.jnf.pt 4/72
1.1. INTRODUCTION
1.2. OVERVIEW
1.3. GENERAL NORMS
A.
B.
C.
D.
E.
1.4. WARRANTY
VOID
A.
B.
1.5. DISPOSAL AND RECYCLING
A.
B.
DO NOT THROW AWAY THE PACKAGING OR PRODUCT MATERIALS ANYWHERE. RECYCLE!!
1. GENERAL SAFETY INSTRUCTIONS EN

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
2.1. INSTALLATION REQUIREMENTS
90º
WALL SIDE VIEW WALL TOP VIEW
2. PRE INSTALLATION EN
3. TECHNICAL DATA EN
3.1. FEATURES
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
AB
D
C
1
4
5
6
7
2
1 - Swing door mechanism
2 - Microwave sensor
3 - E-lock
4 - Keypad acess control
5 - Wireless push button
6 - Touchless sensor
7 - Remote control
8 - Push button
9 - Top scan
3
9
8
CAPTION
1. SWING DOOR MECHANISM
2. MICROWAVE SENSOR
3.
4. NUMBER KEYPAD
5.
6. TOUCHLESS SENSOR
7. REMOTE CONTROL
8. PUSH BUTTON
9. TOP SENSOR

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
SIZE 515x80x115mm
WEIGHT 8kg
WORKING TEMPERATURE -20 ºC ~ +50 ºC
INPUT VOLTAGE AC 200 -250V
OUTPUT VOLTAGE 24V DC (+/- 10%), 3A
OPEN DEGREE Max 115º
OPEN SPEED 45º/s
CLOSE SPEED 45º/s
OPENING TIME 0-60 s (adjustable)
PROTECTION CLASS IP21
3. TECHNICAL DATA
515
80
153
80
28,5
115
500
230 23020
639,5
EN
NOTES:
3.3. DIMENSIONS
3.2. TECHNICAL DATA

INSTALLATION MANUAL / MI0315.1 www.jnf.pt 7/72
3. TECHNICAL DATA EN
3.4. INCLUDED COMPONENTS
DOOR CLOSER MECHANISM REMOTE CONTROL
3.5. OPTIONAL ACESSORIES
MICROWAVE SENSOR
IN.15.731 TOP SCAN
IN.15.737
WIRELESS PUSH BUTTON
IN.15.732
SLIDING ARM FOR GLASS
IN.21.902.C
STANDARD ARM
IN.21.902.B
SLIDING ARM
IN.21.902.A
GLASS CLAMP FOR PUSH ARM
IN.21.903 TOUCH SWITCH
IN.24.207
E-LOCK
IN.28.501
NUMERIC KEYBOARD
IN.28.108 NUMERIC KEYBOARD
IN.28.109
TOUCHLESS SWITCH
IN.21.910
DOUBLE ACTION SENSOR
IN.15.730
WIRELESS TOUCHLESS SWITCH
IN.21.910.WL
(*)
(*) WIRELESS RECEIVER
(*) (OPTIONAL / NOT NEEDED FOR THIS SYSTEM
(*) IN.21.910.RC

INSTALLATION MANUAL / MI0315.1 www.jnf.pt 8/72
3. TECHNICAL DATA
Power switch
0 = Power off
I = Power on
3.6. MECHANISM COMPONENTS
Leſt side cover
Motor
Transformer
220V input
Pull bar
Controller
Right side cover
BOTTOM PLATE PULL BAR COVER
PULL GUIDER MECHANISM
EN

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
4. MECHANICAL INSTALLATION EN
4.1. BAR TYPE
4.1.1. PULL BAR - OPEN TO INSIDE (MECHANISM INSIDE)
Open direction
Open direction
4.1.2. PUSH BAR - OPEN TO OUTSIDE (MECHANISM INSIDE)
Open direction
Open direction

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
4. MECHANICAL INSTALLATION EN
4.2. INSTALLATION OF BOTTOM PLATE
4.2.1. PULL BAR
31 150 133150 31
52
35
Ø17 Power cable
Ø17 Power cable
Ø17 Controller cable
Ø17 Controller cable
Right side installation
Leſt side installation
31 150133 15031
52
35
495
495
Fix the bottom plate on the door frame with 6 screws
(Steel material M6 x 15 mm Inner hexagonal screw)
Fix the bottom plate on the door frame with 6 screws
(Steel material M6 x 15 mm Inner hexagonal screw)
1
2

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
4. MECHANICAL INSTALLATION EN
4.2.2. PUSH BAR
31 150133 15031
52
495
Fix the bottom plate on to door frame
Ø17 Power cable
Ø17 Controller cable
with 8 screws (Steel material M6*15 - Inner hexagonal screw)
Right side installation
Mechanism position Open direction
Ø17 P
ower cable Ø17 Controller cable
31 150133 15031
52
495
Fix the bottom plate on to door frame
with 8 screws (Steel material M6*15 - Inner hexagonal screw)
Leſt side installation
Mechanism position Open direction
Tip:
For push bar installation, the mechanism and open direction are the same.
For pull bar installation, the mechanism and open direction are opposite.

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
4. MECHANICAL INSTALLATION EN
4.3. INSTALLATION OF SLIDING ARM
4.3.1. PULL BAR
0-30
Wall
Door leaf
Pull bar guide
Track
Open direction
115
52
132,5
43
1. Open the door to 90º. Slide the pull guide
roller into the track
2. Fix the pull bar plate as shown
3. Move the plate ensure the wheel at the middle
position of track as shown
4. Hold the plate position. Fix the first screw near
center of the shaſt
5. Close the door, reapeat step 3 and fix another
screw at the other side
6 Manually move the door to ensure pull bar
works smoothly. Adjustment is requested if any
resistance durig the operating
7. Fix the last screw
Door leaf
0-30
Wall
Door leaf
Pull bar guide
Track
Open direction
115
52
132,5
43
1. Open the door to 90º. Slide the pull guide
roller into the track
2. Fix the pull bar plate as shown
3. Move the plate ensure the wheel at the middle
position of track as shown
4. Hold the plate position. Fix the first screw near
center of the shaſt
5. Close the door, reapeat step 3 and fix another
screw at the other side
6 Manually move the door to ensure pull bar
works smoothly. Adjustment is requested if any
resistance durig the operating
7. Fix the last screw
Door leaf
1.
2.
3.
4.
5.
6.
7.
Installation of sliding arm fix plate
Install the fix plate with 3 self-tapping
YIXK]YGYYNU]T
230 230 17020
position stopper
Automaitc door right installation
Move position limiter to adjust open
degree (Position limiter is at leſt
while leſt installation)
Installation of sliding arm fix plate
Install the fix plate with 3 self-tapping
YIXK]YGYYNU]T
230 230 17020
position stopper
Automaitc door right installation
Move position limiter to adjust open
degree (Position limiter is at leſt
while leſt installation)

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
4. MECHANICAL INSTALLATION EN
500
-RGYYYVGIKX
25
180
Tip: Ensure 25mm space for glass top to door frame bottom (Glass door installation)
4.3.2. PULL BAR FOR GLASS DOOR
500
-RGYYYVGIKX
25
180
Tip: Ensure 25mm space for glass top to door frame bottom (Glass door installation)
Automatic door right installation
Adjust the push bar lenght by two screw
according to the door frame’s depth(L).
The glass clamp of the push arm shall be
fastened on the door wing with 4 plug
screws (M6*12) as shown in the figure
Mechanism Wall
Door leaf
Push bar
L≤250mm
115
103,5
52
20
≤250
18
50 450
4.3.3. PUSH BAR
Automatic door right installation
Adjust the push bar lenght by two screw
according to the door frame’s depth(L).
The glass clamp of the push arm shall be
fastened on the door wing with 4 plug
screws (M6*12) as shown in the figure
Mechanism Wall
Door leaf
Push bar
L≤250mm
115
103,5
52
20
≤250
18
50 450
Automatic door right installation
Adjust the push bar lenght by two screw
according to the door frame’s depth(L).
The glass clamp of the push arm shall be
fastened on the door wing with 4 plug
screws (M6*12) as shown in the figure
Mechanism Wall
Door leaf
Push bar
L≤250mm
115
103,5
52
20
≤250
18
50 450
TIP:

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
4. MECHANICAL INSTALLATION EN
4.3.4. PUSH BAR FOR GLASS DOOR
Note: make sure there is a 10mm gap between the top of the glass and the
bottom of the door when using the push arm of the glass door
Note: make sure there is a 10mm gap between the top of the glass and the
bottom of the door when using the push arm of the glass door
Tip: The glass clamp of the push arm shall be fastened on the door wing with 4 plug screws
(M6*12) as shown in the figure
18
50 450
Tip: The glass clamp of the push arm shall be fastened on the door wing with 4 plug screws
(M6*12) as shown in the figure
18
50 450
Note: make sure there is a 10mm gap between the top of the glass and the
bottom of the door when using the push arm of the glass door
NOTE:
NOTE:

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
4. MECHANICAL INSTALLATION EN
Mechanism
Open direction
Wall
Door leaf
Glass clamp
Push bar
Fix the glass clamp and spacer with 4 screw (M6*12) tightly on glass door.
Install the x plate of the push bar with 2 screw (M5*8) on glass clamp.
104
52
20
115
81
≤200
Mechanism
Open direction
Wall
Door leaf
Glass clamp
Push bar
Fix the glass clamp and spacer with 4 screw (M6*12) tightly on glass door.
Install the x plate of the push bar with 2 screw (M5*8) on glass clamp.
104
52
20
115
81
≤200

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
4. MECHANICAL INSTALLATION EN
Hang the mechanism on the fixed base cover with screws.
4.4. MECHANISM INSTALLATION
4.5. ASSEMBLE AND DISASSEMBLE OF THE MECHANISM UP COVER

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
5. WIRED DIAGRAM EN
5.1. TERMINAL DETAILS
123
LED
LEARN +
-
SET
code value
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
+24V
GND
+12V
GND
OPEN-A
COM
FULL LOCK
COM
OPEN-B
COM
20
21
22
23
24
Synchronous(in)
Synchronous(out)
COM
Interlock(in)
COM
Interlock(out)
E-lock+
GND
UPS+
1: LED on/off
2: Master door selector
3: L/R switch
+24V
+12V
GND
Press button"+" or "-" to find the code you want to adjust.
Press button"SET", LED will flash. Then press button"+" or
"-" to adjust value of the code. At last, press button "SET",
LED will stop flash. Date setting is finished.
TEST Test: In double open mode,test
button is disabled on salve
controller
Anti-collision(close)
Anti-collision(open)
123
LED
LEARN +
-
SET
code value
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
+24V
GND
+12V
GND
OPEN-A
COM
FULL LOCK
COM
OPEN-B
COM
20
21
22
23
24
Synchronous(in)
Synchronous(out)
COM
Interlock(in)
COM
Interlock(out)
E-lock+
GND
UPS+
1: LED on/off
2: Master door selector
3: L/R switch
+24V
+12V
GND
Press button"+" or "-" to find the code you want to adjust.
Press button"SET", LED will flash. Then press button"+" or
"-" to adjust value of the code. At last, press button "SET",
LED will stop flash. Date setting is finished.
TEST Test: In double open mode,test
button is disabled on salve
controller
Anti-collision(close)
Anti-collision(open)
CONNECTION OF THE POWER SUPPLY FOR SINGLE OPEN
CONNECTION OF THE POWER SUPPLY FOR DOUBLE OPEN
L
N
EXTERNAL POWER
(AC100 - 240V)
1
2
3
1
2
3
4
22
L
N
EXTERNAL POWER
(AC100 - 240V)
1. +24V
2. GND
3.
4. GND
5.
6. COM
7. FULL LOCK
8. COM
9.
10. COM
11. SYNCHRONOUS
12. COM
13.
14.
15. COM
16.
17.
18. GND
19. UPS +
20. +24V
21.
22. GND
23.
24.
+or -
SET
+or -
SET

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
5. WIRED DIAGRAM EN
5.2. INTERLOCK
CONTROL WHEN THE DOOR CLOSES - MASTER / SLAVE
SYNCHRONOUS
IN SINGLE OPEN MODE
5.3. 24G MICROWAVE SENSOR (IN.15.731)
DOOR A
DOOR A
DOOR B
DOOR B
16.
COM
14.
13.
COM
11.
13.
COM
11.
16.
COM
14.
TIP:
13.
COM
11.
1. +24V
2. GND
9.
10. COM
UPS 18. GND
19. UPS +
ONE POINT

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
5. WIRED DIAGRAM EN
5.4. DIFFERENT SENSOR EXAMPLE
5.6. MAGNETIC LOCK / E-LOCK
5.5. DIFFERENT SENSOR (EXAMPLE: IN.15.730)
9.OPEN-B
3. +12V
4. GND
10.COM
0 (black)
12Vred
18. GND
17.
COM
NC
NO
OPEN
GND
+12V
D-IN
D1
D0
22. GND
22. GND
20. +24V
NO
COM
GND
+24V
NO
COM
GND
+24V
22. GND
22. GND
20. +24V
Anti-clamp sensor when opening
Anti-clamp sensor when closing
24. Anti-collision(open)
RED
PINK
BROWN
WHITE
RED
PINK
BROWN
WHITE
23. Anti-collision(close)
Electronic lock+
Tip: Magnetic lock should connect with power access
Lock current lower than 800mA
ALARM
9.OPEN-B
3. +12V
4. GND
10.COM
0 (black)
12Vred
18. GND
17.
COM
NC
NO
OPEN
GND
+12V
D-IN
D1
D0
22. GND
22. GND
20. +24V
NO
COM
GND
+24V
NO
COM
GND
+24V
22. GND
22. GND
20. +24V
Anti-clamp sensor when opening
Anti-clamp sensor when closing
24. Anti-collision(open)
RED
PINK
BROWN
WHITE
RED
PINK
BROWN
WHITE
23. Anti-collision(close)
Electronic lock+
Tip: Magnetic lock should connect with power access
Lock current lower than 800mA
ALARM
TIP:

INSTALLATION MANUAL / MI0315.1 www.jnf.pt
5. WIRED DIAGRAM EN
5.7. ANTI-CLAMP SENSOR (EXAMPLE: IN.15.737)
5.8. ANTI-CLAMP SENSOR (EXAMPLE: IN.15.730)
22. GND
22. GND
20. +24V
NO
COM
GND
+24V
NO
COM
GND
+24V
22. GND
22. GND
20. +24V
Anti-clamp sensor when opening
Anti-clamp sensor when closing
24. Anti-collision(open)
YELLOW
BROWN
BLACK
RED
23. Anti-collision(close)
YELLOW
BROWN
BLACK
RED
9.OPEN-B
3. +12V
4. GND
10.COM
0 (black)
12Vred
18. GND
17.
COM
NC
NO
OPEN
GND
+12V
D-IN
D1
D0
22. GND
22. GND
20. +24V
NO
COM
GND
+24V
NO
COM
GND
+24V
22. GND
22. GND
20. +24V
Anti-clamp sensor when opening
Anti-clamp sensor when closing
24. Anti-collision(open)
RED
PINK
BROWN
WHITE
RED
PINK
BROWN
WHITE
23. Anti-collision(close)
Electronic lock+
Tip: Magnetic lock should connect with power access
Lock current lower than 800mA
ALARM
TOP SENSOR
IN.15.737
DOUBLE ACTION SENSOR
IN.15.730
Table of contents
Other JNF Door Opening System manuals
Popular Door Opening System manuals by other brands

argenta
argenta PIVOTICA PRO 100 F0 manual

Automatic Technology
Automatic Technology Syncro ATS-3 Quick operation guide

ONLEVEL
ONLEVEL Banana Slide 50 installation instructions

B&D
B&D Smart Pro Quick operation guide

D+H
D+H KA 66-TW1-K-BSY+ Original instructions

Sesamo
Sesamo smart PRO operating instructions