Johanson 4000 User manual

User Manual
Optical Headend
Ref. 4000 & 4001

Optical Headend (Ref. 4000 & 4001)
2
CONTENTS
1. INTRODUCTION .............................................................................. 3
Product description ............................................................................................ 3
Package contents .............................................................................................. 3
2. INSTALLATION OF THE HARDWARE ...................................................... 4
General set-up .................................................................................................. 4
Combining the REF 4000 and the REF 4001 with the LOOPTHROUGH ....................... 5
Cascading the Headends..................................................................................... 6
3. CONFIGURATION OF THE MODULE........................................................ 7
REF 4000 internal product overview..................................................................... 8
REF 4001 internal product overview..................................................................... 8
4. BLOCK DIAGRAM ............................................................................. 9
5. TECHNICAL SPECIFICATIONS ........................................................... 10
6. SAFETY INSTRUCTIONS .................................................................. 11
7. CONDITIONS OF WARRANTY ............................................................ 12
No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language
without permission.
Unitron reserves the right to change the specifications of the hardware and software described in these manuals
at any time.
Unitron cannot be held liable for any damages resulting from the use of this product. Specifications are subject
to change without notice. 8/20
©Unitron NV - Frankrijklaan 27 - B-8970 Poperinge - Belgium
T +32 57 33 33 63 F +32 57 33 45 24
sales@unitrongroup.com
www.unitrongroup.com

Optical Headend (Ref. 4000 & 4001)
3
1. INTRODUCTION
Product description
The 4000 Optical Compact Headend converts 2 wideband satellite inputs into 2 wavelengths
(1310nm –1330nm) and puts them on 1 optical feed. The output signal is strong enough to
support huge installations, with up to 128 passive splits. The 4001 Optical Compact Headend
converts 1 input to 1550nm optical wavelength.
REF 4000: OPTICAL HEADEND TRANSMITTER 2 WAVELENGTHS (1310 NM - 1330 NM)
•2 wideband V/H inputs
•frequency range: 5 - 2400 MHz
•1 optical output (wavelengths: 1310nm (V) - 1330nm(H))
•9 dBm output power
REF 4001: OPTICAL HEADEND TRANSMITTER 1 WAVELENGTH (1550 NM)
•1 wideband input
•frequency range: 5-2400 MHz
•1 optical output (wavelength 1550nm)
•9 dBm output power
•optical input for loopthrough (from ref. 4000)
Package contents
•1x Optical Headend (REF 4000 or REF 4001)

Optical Headend (Ref. 4000 & 4001)
4
2. INSTALLATION OF THE HARDWARE
General set-up
REF 4000
REF 4001

Optical Headend (Ref. 4000 & 4001)
5
Combining the REF 4000 and the REF 4001 with the
LOOPTHROUGH

Optical Headend (Ref. 4000 & 4001)
6
Cascading the Headends
The optical output signal can be split passively up to 128 times, or even more when you
cascade the headends.

Optical Headend (Ref. 4000 & 4001)
7
3. CONFIGURATION OF THE MODULE
•To configure the headend, remove the central bolt and lift the top lid
•The settings will appear on the LED display.
•Use the buttons (SET-DOWN-UP) in the top right corner of the device.
•Follow the steps below to configure the headend.

Optical Headend (Ref. 4000 & 4001)
8
REF 4000 internal product overview
REF 4001 internal product overview

Optical Headend (Ref. 4000 & 4001)
9
4. BLOCK DIAGRAM

Optical Headend (Ref. 4000 & 4001)
10
5. TECHNICAL SPECIFICATIONS
REF 4000
REF 4001
Inputs
-
2 RF
1 RF + 1 optical
(loopthrough from ref. 4000)
Outputs
-
1 Optical
Optical wavelength
nm
1310 - 1330
1550
Frequency range
MHz
5 - 2400
Optical output power
dBm
+9 (per wavelength)
Ripple
dB
+/- 2.5
Optimal input level
dBµV
SAT: 80 per Transponder
TERR: 70 per MUX
Input attenuator
dB
0 - 15
Laser type
-
DFB
Laser LED control
-
Green LED on
LNB power supply
-
12.8V / max. 240 mA
Optical connectors
-
SC/APC
RF connectors
-
F-female
Power consumption
W
9
6
Power supply
VAC
200 - 240
Operating temperature
range
°C
-20 to +55
Protection class
-
IP 50
Dimensions
mm
225 x 190 x 86
Weight
kg
1.8

Optical Headend (Ref. 4000 & 4001)
11
6. SAFETY INSTRUCTIONS
Read these instructions carefully before connecting the unit
To prevent fire, short circuit or shock
hazard:
•
Do not expose the unit to rain or moisture.
•
Install the unit in a dry location without infiltration or condensation of water.
•
Do not expose it to dripping or splashing.
•
Do not place objects filled with liquids, such as vases, on the apparatus.
•
If any liquid should accidentally fall into the cabinet, disconnect the power plug.
To avoid any risk of
overheating:
•
Install the unit in a well aery location and keep a minimum distance of 15 cm around the
apparatus for sufficient ventilation
•
Do not place any items such as newspapers, table-cloths, curtains,
on the unit that might cover the ventilation holes.
•
Do not place any naked flame sources, such as lighted candles, on the apparatus
•
Do not install the product in a dusty place
•
Use the apparatus only in moderate climates (not in tropical climates)
•
Respect the minimum and maximum temperature specifications
To avoid any risk of electrical
shocks:
•
Connect apparatus only to socket with protective earth connection.
•
The mains plug shall remain readily operable
•
Pull out power plug to make the different connections of cables
•
To avoid electrical shock, do not open the housing of adapter.
Maintenance
Only use a dry soft cloth to clean the
cabinet.
Do not use solvent
For repairing and servicing refer to qualified
personnel.
Dispose according your local authority’s recycling processes

Optical Headend (Ref. 4000 & 4001)
12
7. CONDITIONS OF WARRANTY
Unitron N.V. warrants the product as being free from defects in material and
workmanship for a period of 24 months starting from the date of production indicated on
it. See note below.
If during this period of warranty the product proves defective, under normal use, due to
defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace
the product. Return the product to your local dealer for reparation.
THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND
WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM:
•Misuse or use of the product out of its specifications,
•Installation or use in a manner inconsistent with the technical or safety standards in
force in the country where the product is used,
•Use of non-suitable accessories (power supply, adapters...),
•Installation in a defect system,
•External cause beyond the control of Unitron N.V. such as drop, accidents,
lightning, water, fire, improper ventilation…
THE WARRANTY IS NOT APPLIED IF
•Production date or serial number on the product is illegible, altered, deleted or
removed.
•The product has been opened or repaired by a non-authorized person.
NOTE
Date of production can be found in the product’s serial number code. The format will either
be “YEAR W WEEK” (e.g., 2017W32 = year 2017 week 32) or “YYWW” (e.g., 1732 = year
2017 week 32).
UNITRON NV
Frankrijklaan 27
B-8970 Poperinge
Belgium
T +32 57 33 33 63
F +32 57 33 45 24
sales@unitrongroup.com
www.unitrongroup.com
This manual suits for next models
1
Table of contents
Popular Transmitter manuals by other brands

Produal
Produal Proxima WBU Commissioning and Maintenance Instructions

RKI Instruments
RKI Instruments 65-2397RK Operator's manual

Nautel
Nautel NV30 Operation and maintenance manual

TVU networks
TVU networks One TM1000 v2 Set up and operating guide

Emerson
Emerson Rosemount 644 FOUNDATION Reference manual

Aerielle
Aerielle i2i-RDS user guide

Siemens
Siemens SITRANS P 7MF4232 operating instructions

Crestron
Crestron DigitalMedia DMCF-TX-4K-SFP Do guide

HR Smith
HR Smith Techtest 503 Series Maintenance manual

Panametrics
Panametrics DewPro MMY31 Installation and operation manual

Broadata
Broadata 4800 Series user manual

Burkert
Burkert 8025 UNIVERSAL quick start