Joyonway PB553 Technical manual

PB553/PB555control panel image
Control panel operation instruction
49
PB553 panel image
PB555 panel image
set: 95
32 Jets 1
Jets 2
Jets 3
11:55
09-Mar MON
3
2
1
Blower
Heat
1
MENU
4
3
2
1
Mode:off
Cycle pump on
set: 95
32 Jets 1
Jets 2
Jets 3
11:55
09-Mar MON
3
2
1
Blower
Heat
1
MENU
4
3
2
1
Mode:off
Cycle pump on

50
主界面介绍
Left side is state display area
Right side is menu display area
When control panel and control system are connected, control panel screen can
display every function's state of the whole system. User can easily learn the
control system condition with the icons and words.
Main interface image
State display area:
Below are control panel interfaces of PB553 and PB555. Both control panel PB553
and PB555 can match P20B29, P23B32 and P25B37. And they will real time display
the control system state.
PB553/PB555control panel main interface
Control panel operation instruction

51
1) :The current water temperature and the value changes with the water temperature.
Temperature unit can be set as(℉)or (℃)
2) :Temperature unit setting. According to user's need options of (℉)or (℃)are
available.
3) :Display mode: the system can store four different displaying modes. Users can
switch to different display mode they need. And user can set the mode.
4) :Cycle filtration state: cycle filtration can remove the dirt inside the tub and purify
the water. User can set cycle filtration time length.
5) :Pump state:when the pump is started, the icon will turn from half transparent to
full lighting. If low speed pump of (pump)jet 1 is started, there will be a “1”
displayed in the up left corner with green background. If the high speed pump of
pump 1 is started, “1' will be displayed in the up left corner with orange
background. Other pumps are with the similar displaying method with pump1.
6) :Blower state display: when the blower is started, icon will be displayed normally.
When the blower is off, the icon will change to half transparent.
7) :Heating display:when the heating function is started, the icon will blink. If the
heating pipe begins to work then the icon will be displayed normally. When the
heating function is off, the icon will change to half transparent.
8) :Ozone state display:ozone can disinfect. When ozone function is started, the icon
will be displayed normally. If it is turned off, the icon will change to half transparent.
9) :Lamp state display:when the lamp is on, the icon will be displayed normally. If it is
off, the icon will change to half transparent.
Control panel operation instruction 主界面介绍
PB553/PB555control panel main interface

52
Menu displaying area:
10): Press up and down navigation key to move the cursor. The item chosen by cursor
will have green background for words. Press OK to turn on/off or change the state
of the chosen item. If some items only have on or off state, then OK key will turn
them on or off. If some items have multi states, then OK sky will change their states
in turn. The changed state will be displayed in state area. Cursor position in the menu
will be displayed in the progress bar of right side. User can see from the progress bar
whether the cursor has moved to the very top or very bottom of the menu.
11): With large control system, on the top of the menu interface, under “Menu”, there
will be a few bars. The number of bars represents the number of control systems.
Every bar stands for one control system. Press left or right key to switch for different
control system. The current interface displays the control system that the thicker bar
represent. With basic control system, there will be no bars under “Menu” on the
top of menu interface. The last item “set” is used to enter into setting interface.
Time and date:
12): It displays the current time and date. From left to right is: date-month-hour-minute
and week. User can set time in setting interface.
Hint information:
13): When there is error in control system or the keys are locked, the screen displays the
error information or keys lock state. Be aware of the malfunction, user should deal with
it according to control system alarming information described before. If the
malfunction can not be solved, please stop operation right away and contact
technical support. Professionals can identify the source of malfunction with
all the information available.
Control panel operation instruction 主界面介绍
PB553/PB555control panel main interface

5153
Keys functions description:
Control panel PB553 has 10 keys and PB555 has 9 keys. They are navigation keys and
shortcut keys.
set: 95
32 Jets 1
Jets 2
Jets 3
11:55
09-Mar MON
3
2
1
Blower
Heat
1
MENU
4
3
2
1
Mode:off
Cycle pump on
Mode selecting
pump2
pump 1
Screen Invert
light
navigation key (up)
confirm
set: 95
32 Jets 1
Jets 2
Jets 3
11:55
09-Mar MON
3
2
1
Blower
Heat
1
MENU
4
3
2
1
Mode:off
Cycle pump on
PB553 keys description
Control panel operation instruction 主界面介绍
PB553/PB555control panel keys description
PB555 keys description
navigation key (right)
navigation key (left)
navigation key (down)
pump 1
navigation key (up)
pump2
confirm
navigation key (right)
navigation key (left)
light
navigation key (down)
Screen Invert

5154
PB553 and PB555 have the same navigation keys 、 、 、 、 .:" " " " " " " " " "
Users can realize all the operation with navigation keys. In the display interface, the
green background of words or icons is the choosing cursor. Only one item can be
chosen in every interface. With navigation key, the position of cursor can be changed
and relative setting can be changed.
Shortcut key operation instruction:
PB553 shortcut keys include: “ ”、“ ”、“ ”、“ ”、“ ”;
PB555 shortcut keys include: “ ”、“ ”、“ ”、“ ”。
User can start or stop the correspondent function in any interface without returning to home interface.
Pump 1 shortcut key:“ ”or“ ”,will be used to control the on/off of pump 1 , if pump 1
is single speed pump; if (pump)jet 1 is double speed pump, press continuously the key can switch from low
speed to high speed or off. The sequence is: start low speed,->start high speed->turn off.
Pump 2 shortcuts key:“ ”or“ ”,are with the same function as pump 1.
Screen Invert shortcut key:“ ”or“ ”,it can realize the displayed content 180 degree
inverting and navigation key direction will be changed accordingly.
PB553/PB555 keys description
Control panel operation instruction

55
Light shortcut key:“ ”or“ ”,Light has two modes, in mode of on and
off, press the shortcut key can turn on and off the light. In RGB mode, light has 9 states
of auto color change, red, green, yellow, blue, purple, cyan, white and turning off. User
can switch among these states.
Mode selecting shortcut key:“ ”,It is only applicable for PB553. It has four
different modes. Press the key in turn can select the different modes stored by the
user.
Control panel operation instruction PB553/PB555 keys description

56
Manual Heating
When manual heating function is started, a “ ”heating choice will be added
in the menu. User can manually start the heater in the home interface. When the
manual heating function is turned off, the heating choice will disappear.
Move the cursor to the last item ”set” in the menu of the home interface, press “ ”
and enter into setting interface. There are totally 11 items in the setting interface
including auxiliary system function, time setting, user habit storage, system information,
etc. User can set the appropriate mode and heating time length with their own need.
Manual Heating
Heat
Control panel operation instruction PB553/PB555 keys description

57
When the green cursor is at “ ”or” ”, press
“ ” to set the time period as on or off. Press
“ ”, entering into time setting. Press “ ”
to move the cursor. Press “ ”and “ ” to set
the time. Press “ ”and “ ” to exit the time
editing. And cursor will be move back to the very left
side. After the time setting is done, press “ ” to
return and store the setting.
Heating time
When the control system is set as timing heating mode, heater can operate automatically
in two sets of the time periods. And the two time periods are independent from each other.
Two time period can be set overlapped, like time period 06:15 ---13:15, , time period
10:15---16:15. Then heater will work between 06:15---16:15. if the starting time is larger
than the ending time, then heater will continuously work till the end time of next day, for
example if the time period is between 20:00---10:00, then the heater will work from the
20:00 of first day till the 10:00 of the next day. Note: when the time period is set as on, the
heater will work, if time period is set as off, heater will turn off.
Note: These set times are all based on system time. So user need to ensure the accuracy
of the system time when setting the time period.
PB553/PB555 setting interface
Control panel operation instruction

58
Manual C.Pump
This item will appear when the control system has separate pump as cycle pump. When
the manual cycle pump function is started, there will be a cycle pump item “ ”
in the function operation interface. User can manually start cycle pump in the home
interface. When the manual cycle pump function is turned off, this item will disappear.
Filter time
To purify the water and keep the tub clean it is
necessary to filter the water regularly. When
the control system is set as timing water cycle
mode, its starting and stopping method is the
same as timing heating on/off and their time
period setting methods are the same. User
need to regularly change the filter or strainer
according to the water quality.
User can set and store the function state according to their preference which is defined
as mode. PB553 and PB555 control panel have four different modes. They can be stored
and selected with navigation keys.
Mode
CPump
Control panel operation instruction PB553/PB555 setting interface

59
How to store the setting: first, set each function according to personal need. In Set->
Mode of the menu, by pressing “ ”and “ ”to move the cursor to the items
need to be saved then press “ ”. if the square on the right side of the item is solid,
then it indicates the current mode is stored. Mode of jet(pump), blower, ozone, heat,
and brightness can be stored.
How to select the mode stored? In the main interface,
by pressing “ ” and “ ”to move the cursor
to “ ”. Then press “ ”to select the stored
the modes. PB 553 control panel can use mode
selecting short-cut key “ ”. Note: please pre-set
when use the mode function the first time.
Temp. unit
In menu of Set, press “ ”and “ ”to move the
cursor to “Temp. unit”, then press” “, setting the
temperature unit as ℃ or ℉.
Set
Ozone
Light
Blower
Set
MENU
Mode
Heating time
Temp.Unit
Manual Heating
Mode
On
Back
Temperature
Filter time
>>
>>
>>
>>
C
Manual C.Pump On
Control panel operation instruction PB553/PB555 setting interface

60
Temperature
It refers to set the water temperature inside the
bath tub. Water temperature range is 50 F- 104F
(10C -40C). In Set-> Temperature of the menu,
temperature value can be increased and
decreased with “ ” and “ ”. The set
temperature will be automatically stored when
exit menu. When the set temperature value is
higher than the current water temperature and
the heat function is on. The heater will
automatically heat.
Ozone
Ozone function has manual mode and auto mode.
In the Set of the menu, by pressing “ ”and “ ”to move the cursor to Ozone.
Then press “ ”to set the ozone as auto start or manual start.
Auto start operation can refer to control regulation description of the control system.
When manual mode is chosen, there will be a symbol of” “increased in the menu.
User can manually start the ozone in main interface. When manual start mode is turned
off, the symbol will disappear.
Control panel operation instruction PB553/PB555 setting interface

61
Auto lock
To avoid unconscious touch of the keys, the panel is equipped with auto lock function.
In the set of menu, pressing “ ”and “ ”to move the cursor to the item of
“Auto Lock”. Then press “ ”. The lock starting time can be set as “off”, “30S”
, “1 min” and “3 min”. When set as off, the lock function is turned off. Set as “30S”
or other time length, the control panel will return to main interface and start lock
function when detecting no actions on the panel key within the set time. When the lock
is started, press continuously “ ”for 3S, “Auto Lock” disappear from the screen
and lock stops.
To ensure that user can use the control system
comfortably with different lighting environment,
the backlight brightness of the screen can be
adjusted according to the environment lighting
condition. Backlight brightness range is 1-30. In
the set-> Brightness of the menu, pressing “ ”
and “ ”to adjust the backlight brightness.
The set value will be automatically stored when exiting menu.
Brightness
Control panel operation instruction PB553/PB555 setting interface

Set
Auto Lock Off
Back
Temperature
Brightness
Function
Ozone
Light
Blower
Set
MENU
Mode
>>
>>
>>
About >>
Date&Time
Wifi
>>
Ap
62
Date & Time
Time accuracy is very important to the control
system. All the timing function setting (timing
heating and timing water cycle) is based on the
control system time. So the user needs to set the
control system time in ahead.
In the Set-> Date &Time of the menu, press “ ”
to move the cursor, and set the date and time with
“ ” and“ ”. The setting will be automatically
stored after exiting the menu. If the control system
is off power, the correct time setting can be kept for
a few days. Wifi
When the control system is connected with Wifi module,
in the Set -> of the menu, there will be Wifi choice. Press
“ ”and “ ” to move the cursor to “Wifi” and
press “ ”. Wifi can be set as AP mode or Sta mode or
“forgetting the connected Wifi”. When Wifi module is
working in AP mode, user can search Joyonway-xxxx with
cell phone APP to connect to the control system;
when wifi module is working in Sta mode, user
can connect to control system with local area
network or internet. For Wifi connecting and
operating please refer to APP instruction.
Control panel operation instruction PB553/PB555 setting interface

Pressing “ ” and “ ”, moving the cursor
to the item to be set. Then press “ ” to change
its configuration parameter.
To (pump)jet ( jet1, jet2, jet3, and jet4) , if the figure
in “ ”is 2, then it is double speed pump. If the
figure in “ ”is 1, then it is single speed pump. If
the figure in “ ” is 0, then it is invalid.
To light, if the figure in “ ”is 2, then it is in RGB
mode, if the figure in “ ”is 1, then it is in on/off
mode. If the figure inside is 0 then the light is invalid.
To cycle pump, if the figure in “ ”is 1, then
control system is separately set with cycle pump; if the figure in “ ”is 0, then
the jet 1 low speed pump is set as cycle pump. 63
Function
Function setting is used to set control system loads and Panel ID. When the control
system is allowed to be set (please refer to the description in control system connection
and setting), find the item “Function>>” in the Set of menu, press “ ”and “ ”
to move the cursor to item “Function>>” then press “ ”to enter Set-> Function.
In Set-> Function of the menu, there are totally 12 items. They are (pump)Jet1, Jet 2,
Jet 3, Jet 4, Light, Blower, Water cycle Ozone, Independent cycle, Heat, Water level and
Panel ID as the picture shown below.
Set->Funtion
Jets 1
Jets 2
Blower
Jets 3
Jets 4
Light
Ozone
Back
Ozone
Light
Blower
Set
MENU
Mode
Cycle pump
Panel ID
Back Set
Mode
Control panel operation instruction PB553/PB555 setting interface

64
About
In the Set of Menu, press “ ”and “ ”to move
the cursor to item “About”. Then press “ ”to
enter Set-> About. In Set-> About of the menu, the
current control system function configuration
condition and software version is displayed.
In the choices for (pump) jet1, jet2, jet3 and jet4,
“Two speeds” means double speeds pump. “One speed”
Means single speed pump. To light, RGB represents the
light is set as RGB mode. “Yes” represents the light is
set as on/OFF mode. “No” means it is invalid.
To blower, “Yes” means the blower function is set.
“No” means it is invalid.
To panel ID, it can be set as 1, 2, 3, or 4, these numbers are used to differ control panels
and the control panel ID must be unique. To other loads, if the figure in “ ”is 1,
then this load is set. If the figure in “ ”is 0 then the load is invalid.
To ozone, “yes' means ozone function is set, “No” means ozone function is invalid.
To cycle pump, “yes” means control system is set with separate cycle pump. “No”
means Jet 1 , the low speed pump is set as cycle pump. To panel ID, the figure
means control panel ID. NO. To panel version and control system board version,
figure means soft ware version NO.
Control panel operation instruction PB553/PB555 setting interface
This manual suits for next models
1
Table of contents
Popular Control Panel manuals by other brands

Honeywell
Honeywell MB-Secure 1000 installation instructions

Victron energy
Victron energy Color Control GX manual

Dahua Technology
Dahua Technology VTH5422HB-W user manual

Dover
Dover MagLink LX4 Configuration manual

Chamberlain
Chamberlain LiftMaster Professional CB124 instructions

Renkforce
Renkforce 1713218 operating instructions