JRC JCY-1900 User manual

JCY-1900/1950JCY-1900/1950
VOYAGE DATA RECORDERVOYAGE DATA RECORDER (VDRVDR)
01ETM ISO 9001, ISO 14001 Certified
Printed in Japan
Marine Service Department
+81-3-3492-1305
+81-3-3779-1420
Telephone :
Facsimile :
e-mail :
AMSTERDAM Branch
Telephone :
Facsimile :
e-mail :
+31-20-658-0750
+31-20-658-0755
SEATTLE Branch
Telephone :
Facsimile :
e-mail :
+1-206-654-5644
+1-206-654-7030
CODE No.7ZPNA4409CODE No.7ZPNA4409
AUG. 2014 Edition 1 JRCAUG. 2014 Edition 1 JRC
Not use the asbestos
For further information,contact:
URL http://www.jrc.co.jp
SIMPLIFIED VOYAGE DATA RECORDERSIMPLIFIED VOYAGE DATA RECORDER (S-VDRVDR)
SERVICE MANUALSERVICE MANUAL


ŶNOTICE
ƔIt is strictly prohibited to reproduce part or all of this manual without prior permission.
ƔThe contents of this manual are subject to change without notice.
Copyright© Japan Radio Co., Ltd. 2014 All rights reserved.
7ZPNA4409


JCY-1900
/
1950
V
DR Service Manual
i
DOC No. 7ZPNA4409

JCY-1900
/
1950
V
DR Service Manual
ii
DOC No. 7ZPNA4409
Before Operation
Pictorial indication
Various pictorial indications are included in this manual and are shown on this equipment so that you can
operate them safely and correctly and prevent any danger to you and / or to other persons and any damage
to your property during operation. Such indications and their meanings are as follows.
Please understand the meanings of pictorial indication before you read this manual.
DANGER Indicates that it is probable that incorrect equipment operation due to
negligence cause death or a serious injury.
WAR N IN G Indicates that it is possible that incorrect equipment operation due to
negligence cause death or a serious injury.
CAUTION Indicates that it is probable that incorrect equipment operation due to
negligence cause human injury or property damage.
Examples of pictorial indication
The mark indicates CAUTION (including DANGER and WARNING).
Detailed contents of prohibited action (“Electric Shock” in the example on the left) is shown in the mark.
The mark indicates prohibition.
Detailed contents of the prohibited action (“Disassembling Prohibited” in the example on the left) is
shown in the mark.
The mark indicates instruction.
Detailed contents of the instruction ("Disconnect the power plug" in the example on the left) is shown in
the mark.
Warning Label
There is a warning label on the front panel of equipment. Do not try to remove, break or modify the label.

JCY-1900
/
1950
V
DR Service Manual
iii
DOC No. 7ZPNA4409

JCY-1900
/
1950
V
DR Service Manual
iv
DOC No. 7ZPNA4409
Precautions
DANGER
The prohibited matter of a battery and a lithium battery.
●To short-circuit the + pin and – pin.
●Using for non-specified applications.
●disassembling, modifying, destroying.
●Throwing into fire, heating.
●Using expired battery.
There is a danger that cause leakage of fluid, generation of heat, fire, explosion, destruction, or
injury by heat.
WARNING
Do not attempt inspections or repairs on the internal part of the equipment by yourself. Inspec-
tions or repairs by anyone other than qualified maintainers may cause a fire or electric shock.
Please contact our head office, or a nearby branch or local office to request servicing.
Do not disassemble or remodel this equipment.
Such action may cause a fire, electric shock, or malfunction of the equipment.
Do not use any power supply voltage other than the specified one.
Such action may cause a fire, electric shock, or malfunction of this equipment.
Turn off power supply switch before connecting or disconnecting cables to any external equip-
ment.
Not turning it off may cause a fire or an electric shock.
If the power supply cable damaged, please contact our head office, or a nearby branch or local
office to request servicing.
The use of damaged cables may cause a fire or an electric shock.
If water entered the equipment, make sure to turn off the main power, open the breaker, and
please contact our head office, or a nearby branch or local office to request servicing.
Using it as it is may cause a fire, electric shock, or malfunction.

JCY-1900
/
1950
V
DR Service Manual
v
DOC No. 7ZPNA4409
WARNING
If equipment malfunctions, make sure to turn off the main power, open the breaker, and please
contact our head office, or a nearby branch or local office to request servicing.
The continuous use of the equipment may cause a fire or electric shock.
The Recording Control Unit (NDV-1900/1950) has a built-in battery.
The battery needs to be replaced periodically. If using continually an expired battery, a fire may
occur.
Never replace the battery by yourself.
Replacement by anyone other than qualified maintainers may cause a fire, an electric shock, or a
malfunction.
Please contact our head office, or a nearby branch or local office to request servicing.
The Recording Control Unit (NDV-1900/1950) has a built-in battery.
The battery contains dilute sulfuric acid. If the liquid that has leaked from the battery adhered with
your clothes or skin, wash with clean water. If the liquid entered your eyes, immediately wash with
clean water and see a doctor.
The Recording Control Unit (NDV-1900/1950) has a built-in battery.
Do not discard because used batteries are recycled. Please contact our head office, or a nearby
branch or local office to request servicing.
The underwater acoustic beacon of fixed protective capsule unit and float free capsule unit has a
built-in lithium battery.
Do not discard because used lithium batteries are recycled. Please contact our head office, or a
nearby branch or local office to request servicing.
If disposing of this equipment, be sure to abide by applicable local laws and regulations.

JCY-1900
/
1950
V
DR Service Manual
vi
DOC No. 7ZPNA4409
WARNING
The Recording Control Unit (NDV-1900/1950) has a UTILITY OUTLET.
When you connect the power plug to the power outlet, insert it firmly.
Failure to do so may cause fire, burns or electric shock.
The Recording Control Unit (NDV-1900/1950) has a UTILITY OUTLET.
Clean dust from the power plug.
Failure to do so may cause fire.
Do not inset or drop any foreign objects such as metallic pieces into an air vent or opening.
Otherwise, it may cause a fire, electric shock or malfunction.
Do not place heavy objects on the power cable or do not bend the power cable by force.
Otherwise, the power cable is damaged, and it may cause a fire, electric shock.
Do not put the container with the liquid on or near this equipment.
Otherwise, if the liquid spill or come in this equipment, it may cause a fire, electric shock, or mal-
function.
If anything abnormal such as smoke, strange smell or unusual heat is emitted, turn off the
POWER switch of the equipment immediately and pull out the power cable. Then, please contact
our head office, or a nearby branch or local office to request servicing. The continued use of the
equipment may cause a fire or electric shock.

JCY-1900
/
1950
V
DR Service Manual
vii
DOC No. 7ZPNA4409
CAUTION
This equipment has warning labels.
Do not try to remove, break or modify the label.
Do not install the equipment on the location where infringed by water, humidity, steam, dust, or
soot.
Otherwise, it may cause a fire, electric shock, or malfunction.
Do not touch this equipment, if hands or gloves are wet with water.
Otherwise, it may cause an electric shock, or a malfunction.
Be sure to hold power supply plug when pulling it out of outlet.
Pulling the power cable without holding the plug may damage the cable and may cause a fire or
an electric shock.
Although the shape of UTILITY OUTLET is for 100VAC, it directly outputs the voltage (100 to
220VAC) that is being input to the RCU. Do not connect a equipment for 100VAC, if 220VAC is
being input. Otherwise, a malfunction may occur.
If the equipment is splashed either with water, wipe it dry immediately.
Otherwise, it may cause a failure or operational malfunctions.
Do not use any organic solvents such as thinner or benzine to clean the surface. These agents
can damage the surface coating.
Be sure to remove dirt and dust from the surface and wipe it using a clean dry cloth.
Do not carry out the tap of the screen by the sharp object.
Otherwise, the screen may be damaged.

JCY-1900
/
1950
V
DR Service Manual
viii
DOC No. 7ZPNA4409
CAUTION
Do not block up the air vent of this equipment.
Otherwise, the inside of equipment is filled with heat, and it may cause fire or malfunction.
Do not install the equipment on the unstable place such as on the shaky stand or inclined surface.
Otherwise, it may drop or fall down, resulting in an injury or malfunction.

JCY-1900
/
1950
V
DR Service Manual
ix
DOC No. 7ZPNA4409
Precautions (FFC)
WARNING
If the false distress alert is transmitted, take the following instructions immediately.
(1) Stop the transmission immediately.
(2) Report the following information to the Maritime Safety Agency.
(a) Ship’s Name, Type and Flag
(b) Capsule ID number (15 character UIN):
(c) Position and Time at the false transmission
(d) Cause of the false transmission
(e) Type, Serial Number and Delivery Date of the capsule
Do not pull up the capsule from water during distress.
If the capsule is taken out from water in distress, it stops sending distress signals.
The capsule EPIRB function must not be used for other than distress.
Otherwise, a large trouble will be given to the search rescue organization.
Do not set the switch to "ON" except the case of manual activation in distress.
Distress signals are transmitted when turning the switch "ON".
The capsule unit must not be taken out from bracket other than distress.
Otherwise, a large trouble will be given to the search rescue organization.
The selector switch must be set to the “READY” position while voyaging.
The hydrostatic release unit (HRU) activates the cutter using spring force. Do not disassemble the
HRU, nor apply pressure to it. Serious injury could result.

JCY-1900
/
1950
V
DR Service Manual
x
DOC No. 7ZPNA4409
WARNING
Once the hydrostatic release unit (HRU) operates, it cannot be reused. Be careful for capsule so
as not to be stolen or not to be activated by mischief when the ship is in port.
Confirm that the ship's name and ID correspond to those indicated on the label of the capsule
unit.
Rescue work will be planned and executed based on the information of ship's name and ID
transmitted from the capsule unit. Proper planning of rescue work would not be possible if ship's
name and ID are wrong. If the ship's name and ID indicated on the label of the capsule unit is
wrong, ask the purchasing dealer, JRC agent or the JRC branches to change it with correct ship's
name and ID.
If right ID cannot be set in the capsule, do not install the capsule. Otherwise, a large trouble will be
given to the search rescue organization.
Do not install the capsule in an extremely vibrating place such as a handrail. The capsule may be
damaged due to vibration.
Do not install the capsule in a strong magnetic field. The capsule may activate by the magnetic
force.
The capsule must be installed apart from the compass and so for the 0.8 meters or more so that
the magnetism is not influenced.
Mount the capsule on the bracket properly.
Improper mounting causes the capsule not to be automatically released from the bracket in a
sinking.
The battery and hydrostatic release unit (HRU) which expired effective periods expired must not
absolutely be used.
If such battery and HRU are used, the distress signal may not be emitted at the distress. Take
care that their lives do not expire.

JCY-1900
/
1950
V
DR Service Manual
xi
DOC No. 7ZPNA4409
WARNING
Do not install with the capsule battery removed. The distress signal may not be emitted at the
distress.
Do not connect the lanyard to the bracket or ship body.
It disturbs at emergency.
When disposing of the capsule, contact the purchasing dealer, JRC agent or JRC branches to
request servicing.
If the capsule is transmitted the distress signal by improper disposal, large confusion is caused in
search and rescue operations.
Do not make the used battery to short-circuit, discharging electricity compulsorily or using for
other usages. Send used batteries to the purchasing dealer, JRC agent or JRC branches.
Do not discard used batteries. Send used batteries to the purchasing dealer, JRC agent or JRC
branches, to avoid causing environmental problem by throwing them away.
When sell the ship, contact to the purchasing dealer, JRC agent or JRC branches, and request to
register the radio station license and reset up the ship's name and ID.
If registration and reset up are not executed, false transmission or wrong ID code signal might be
transmitted in distress, and it causes serious confusion for search and rescue operation.

JCY-1900
/
1950
V
DR Service Manual
xii
DOC No. 7ZPNA4409
CAUTION
Open slowly the top cover.
If you open faster, the capsule may deviate from bracket and fall down.
Test the EPIRB function, while anchoring in a port.
In EPIRB function test, permitted distress signal for the test purpose is transmitted. Do not exe-
cute the test repeatedly in a short time.
Execute the test in 00 - 05 minutes of each o'clock for the reduction of processing capacity in the
satellite.
Do not remove, destroy, or modify warning labels.
Request purchasing dealer, JRC agent or JRC branches to replace any stained, illegible, or
damaged label.
If the abnormal status is recognized in the capsule. request the service to purchasing dealer, JRC
agent or JRC branches,
If you want to replace or repair the capsule, contact the purchasing dealer, JRC agent or JRC
branches.
Do not use a solvent (paint-thinner, alcohol etc.) or alkaline/neutral detergent to clean up the
capsule.
It causes crack on the resin if such a detergent is used, and the capsule may not operate properly
in the worst case by leaking etc.

JCY-1900
/
1950
V
DR Service Manual
xiii
DOC No. 7ZPNA4409
Contents
BEFORE OPERATION ............................................................................................................................... II
PRECAUTIONS.......................................................................................................................................... IV
PRECAUTIONS (FFC) .............................................................................................................................. IX
1. OUTLINE.......................................................................................................................................... 1
1.1. Outline of the Equipment...........................................................................................................................1
1.2. Feature of New VDR/S-VDR.......................................................................................................................1
1.3. JCY-1900/1950 Configuration....................................................................................................................3
1.4. Present and New Model Comparison Table .............................................................................................8
1.5. JCY-1900/1950 System Diagram .............................................................................................................10
1.6. JCY-1900/1950 System Block Diagram ..................................................................................................11
1.7. JCY-1900/1950 System Network Diagram ..............................................................................................14
1.8. JCY-1900/1950 System Configuration ....................................................................................................15
2. MAINTENANCE............................................................................................................................. 26
2.1. Replacement Parts list.............................................................................................................................26
2.2. Maintenance Parts list .............................................................................................................................27
2.3. Spare Parts list .........................................................................................................................................28
2.4. Fixed Protective Capsule Unit : NDH-338...............................................................................................29
2.5. Recording Control Unit : NDV-1900/1950 ...............................................................................................30
2.6. Digital Signal Converter 32CH/64CH: NCT-82/-83..................................................................................43
2.7. Frame Grabber Unit : NWP-69.................................................................................................................44
2.8. Data Acquisition Unit: NCT-84.................................................................................................................46
2.9. Software Update .......................................................................................................................................47
3. OPERATION CHECKING ON HARDWARE ................................................................................. 48
3.1. Fixed Protective Capsule Unit : NDH-338...............................................................................................48
3.2. Float Free Capsule Unit : NDH-339 .........................................................................................................50
3.3. Recording Control Unit: NDV-1900/1950 ................................................................................................53
3.4. Operation Panel Unit: NCG-1900/1950 ...................................................................................................59
3.5. Microphone Unit: NVT-181 and Waterproof Microphone Unit: NVT-182..............................................61
3.6. Digital Signal Converter 32CH and 64CH : NCT-82/83...........................................................................62
3.7. Frame Grabber Unit: NWP-69..................................................................................................................64
3.8. Data Acquisition Unit: NCT-84.................................................................................................................65
4. TROUBLE SHOOTING.................................................................................................................. 66
5. DIAGNOSIS OF THE CONNECTION EQUIPMENT BY REMOTE MAINTENANCE................... 74
6. SCHEMATIC DIAGRAMS (CIRCUIT DIAGRAMS)....................................................................... 75
6.1. Recording Control Unit: NDV-1900/1950 ................................................................................................75
6.2. Operation Panel Unit: NCG-1900/1950 ...................................................................................................76
6.3. Frame Grabber Unit: NWP-69..................................................................................................................77
6.4. Digital Signal Converter 32CH: NCT-82 ..................................................................................................78
6.5. Digital Signal Converter 64CH: NCT-83 ..................................................................................................79
6.6. Data Acquisition Unit: NCT-84.................................................................................................................80
7. SPECIFICATIONS ......................................................................................................................... 81
7.1. NDH-338 Fixed Protective Capsule Unit.................................................................................................81
7.2. NDH-339 Float Free Capsule Unit ...........................................................................................................82
7.3. NDV-1900/1950 Recording Control Unit .................................................................................................83
7.4. NCG-1900/1950 Operation Panel Unit.....................................................................................................86
7.5. NVT-181 Microphone Unit........................................................................................................................87
7.6. NVT-182 Waterproof Microphone Unit....................................................................................................88
7.7. NCT-83 Digital Signal Converter 64CH ...................................................................................................89
7.8. NCT-82 Digital Signal Converter 32CH ...................................................................................................90
7.9. NWP-69 Frame Grabber Unit ...................................................................................................................91
7.10. NCT-84 Data Acquisition Unit..................................................................................................................92
7.11. NQE-7700A Junction Box ........................................................................................................................93

JCY-1900
/
1950
V
DR Service Manual
xiv
DOC No. 7ZPNA4409
7.12. General Environmental Condition ..........................................................................................................94
8. ANNUAL INSPECTION ................................................................................................................. 96
8.1. Declaration on Completion of Annual Inspection for VDR ...................................................................96
8.2. Annual Inspection Procedures ...............................................................................................................96
9. INSPECTION CHECK LIST FOR VDR ......................................................................................... 96

1. OUTLINE
JCY-1900
/
1950
V
DR Service Manual
1
DOC No. 7ZPNA4409
1. OUTLINE
1.1. Outline of the Equipment
This equipment helps investigators identify the causes of marine accidents in order to prevent their recurrence.
The equipment records navigation and hull data, as required by International Standards.
1.2. Feature of New VDR/S-VDR
1) Sensor Data I/F
●Reduction of serial wiring cables is possible by sharing data (LAN: IEC61162-450) with new RA-
DAR/ECDIS.
(For introduction, confirmation for supervisory authorities and ship's classification is required.)
2) Image Data I/F
●Reduction of RGB wiring cable (5 coaxial cables) is possible by connecting to new RADAR/ECDIS
through LAN (IEC61162-450).
3) Capsule I/F
●No separate power cable is required since power is supplied to the capsule unit with the LAN cable.
4) Data recording in capsule units (meet the demands of new standard)
Both the fixed protective capsule unit and the float-free capsule unit store the data recorded for the past 48
hours.
●In VDR (JCY-1900), install both the protective and the float-free. In S-VDR (JCY-1950), install one of
capsules.
●When retrieving the capsule units from the sea, with this 48-hour data recording function, the situation in
the event of an accident can be analyzed by comparing it to that before the accident.
●Addition of the float-free capsule unit makes the retrieval of recording data easier.
5) Data recording in the internal storage (meet the demands of new standard)
The internal storage stores the data recorded for the past 720 hours.
●With this 720-hour recording internal storage, the residual ratio of accident data rises substantially.
●For voyage within 720 hours, all the data during the voyage can be recorded.
6) Audio recording for the bridge
●The 6-track microphone audio function enables recording of conversations in the bridge at 4 places in
addition to the dedicated audio recording in the wing.
●Sound quality is improved (newly designed microphones and re-examined A/D conversion and com-
pression performance).
●Downsized microphone unit and waterproof microphone unit.
7) VHF audio recoding
●The 2-track VHF audio function enables separate recording of No. 1 VHF and No. 2 VHF.
8) RADAR/ECDIS image recording (meet the demands of new standard)
●The 3-screen capacity for image recording enables recording of 3 screens in total (6 channels at max-
imum) for X band RADAR, S band RADAR and ECDIS.
●Recording image alternately for the same units.
9) Performance test (meet the demands of new standard)
●Checking the latest recorded data is available through the Operation Panel Unit..

1. OUTLINE
JCY-1900
/
1950
V
DR Service Manual
2
DOC No. 7ZPNA4409
Standards:
•The 3 screens (X band RADAR, S band RADAR and ECDIS) are recorded every 15 seconds.
* When Rader is standby, the screen is recorded every 20 minutes. (The requirement by the standard
is recording every 10 to 30 minutes.)
•For the same units, screens are recorded alternately.
Screen-1
Screen-2
Screen-3
Screen-1
Screen-2
Screen-3
Other manuals for JCY-1900
2
This manual suits for next models
1