JRI SPY RF Modem User manual

USER MANUAL
Spy RF Modem
06253H

©JRI 2
TABLE OF CONTENTS
I. INTRODUCTION............................................................................................................................................................3
a) Equipment .................................................................................................................................................................................3
b) Symbols.....................................................................................................................................................................................3
II. PRESENTATION............................................................................................................................................................3
a) Raccordements.........................................................................................................................................................................4
III. INSTALLATION RECOMMENDATIONS.......................................................................................................................4
a) Perturbations sources..............................................................................................................................................................4
b) Position......................................................................................................................................................................................4
c) Installation of wall-mounting bracket......................................................................................................................................5
IV. LEDS’ INDICATIONS.....................................................................................................................................................5
V. CHARACTERISTICS .....................................................................................................................................................5
VI. WARRANTY...................................................................................................................................................................6
VII. MAINTENANCE CONTRACT........................................................................................................................................6
VIII. ENVIRONMENT PROTECTION.....................................................................................................................................6

©JRI 3
I. INTRODUCTION
Congratulations, you own a SPY RF Modem ! This devise is dedicated to communicate wirelessly with the Spy
RF recorders range
a) Equipment
1 SPY RF Modem
1 user manual
1 wall-mounting bracket
1 USB cable or RS232 cable
b) Symbols
II. PRESENTATION
SPY RF USB Modem SPY RF RS232 Modem
RECYCLING : do not throw in a rubbish dump or in a domestic waste container. Comply to the regulation to throw away
the device.
POWER SUPPLY : this device is powered in 9VDC 650mA delivered by a main power supply adaptor 100-230VAC 50-60Hz.
Comply to the security and utilization regulations of electric power. Use a an electric installation complying to these
regulations
CE MARKING :this equipment is certified to comply with the European regulation for the electric security, inflammability,
disturbing radiation emission and immunity to surrounding electric disturbances.
FCC ID : 09584
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation
In accordance with FCC requirements, changes or modifications not expressly approved by JRI could void the user's
authority to operate this product.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
USB cable
2,9m
2,9m
RS232 cable

©JRI 4
a) Raccordements
Spy RF ModeM USB Spy RF ModeM RS232
The device connected to the alarm connector must be SELV "Very low voltage." SELV
no active part of the system shall be grounded. The masses of material SELV must be
isolated from other masses and other conductive parts by double insulation.
III. INSTALLATION RECOMMENDATIONS
To guarantee optimal radio transmission, it must meet a number of recommendations, as any wireless
transmission is subject to disturbances.
a) Perturbations sources
Presence of obstacles in the way of the waves between the Spy RF ModeM and the Spy Rf (wall,
ceiling, person, furniture…) or close to the antenna.
Obstacles thickness in the way of the waves. The absorption is more important in diagonal as
perpendicularly
Waves cannot pass through full metallic walls. On the other hand, a perforated wall allows the
waves passing with attenuation
b) Position
Place the devices at ~2m high and around 30 to 40cm from the ceiling to avoid obstacles and
moving persons.
If possible, place the Spy RF in central position regarding the Spy RF recorders.
Try to place them preferably at sight of each other .
On the wall, it is preferable to them aside by using the special bracket (ref 08512) of the catalog.
Place the antenna above the top the monitored unit (fridge, incubator, oven, cold rooms…),.
Never place the Spy RF horizontally.
If some difficulties persist, it is possible to use Spy RF RelaY (repeaters) or to connect another Spy
RF ModeM to the Ethernet network (LAN).

©JRI 5
To ensure your safety during installation or intervention on a device at this height (2m), use a
stable means to and in good used condition, wear suitable footwear and non-slippery and
install security markup if intervention takes place in a place of passage.
c) Installation of wall-mounting bracket
The bracket can be fixed thanks to its adhesive plaster or it can be screwed.
Screwing map
IV. LEDS’ INDICATIONS
General
= ModeM-PC dialog Instantaneous reading
= 1 Flash during reading
= Radio communication
Standby Upload memory
= 1 Flash every seconds = Fast flashing along the
transfer duration
V. CHARACTERISTICS
Radio band 868MHz or 902MHz*
Operating range -40°C +85°C
Storage conditions -30 + 70°C / 0-90% not condensed
Emitting power 25 / 500mW
power supply 9VDC / 0,3A**
Relay output 30VDC
–
1A
Dimensions 123x69x30mm
CE ERM FCC conformity EN 301 489 / EN 61000 / EN 61010 EN 55022 / EN 300 220
FCC conformity FCC part 15*
*Only for Spy RF USB ** Included for Europe market

©JRI 6
VI. WARRANTY
JRI products carry a one year warranty and guarantee against defects in their components or workmanship.
During this period if any product supplied by the Company proves on inspection to be defective, the Company will
at its own option replace the same or refund to the Buyer the price of the product.
In no circumstances will JRI' liability exceed the price of the product paid by the buyer or the cost of replacement.
JRI shall not in any event be liable to the Buyer for any indirect or consequential loss or damage costs or expenses
whatsoever which might arise out of or in connection with the supply of the product or its consequent use.
Consequently, the products warrantee and guarantee specified above, does not cover damage caused by fair
wear and tear, abnormal storage conditions, incorrect use, accidental misuse, abuse, neglect, misapplication or
modification, or use with non-JRI' hardware/software. No warranty of fitness for a particular purpose is offered
and the user assumes the entire risk of using the product.
In line with our policy of continuous development, we reserve the right to amend our product specification
without prior notice.
VII.MAINTENANCE CONTRACT
How to optimize your radio frequency installation?
RF measuring systems communicate by radio frequency. However, there may be several factors that can modify
the radio ways already defined, such as moving from a building, adding walls, … Radio frequency requires thus a
periodical follow up performed by specialists.
That’s why JRI has created maintenance contracts. We bring you a global solution which makes your maintenance
easier. This overall service offer includes maintenance and also metrological services, which ensure you that your
system is fully performant.
You won’t worry about your devices maintenance anymore !
With this maintenance contract you will benefit for a minimal period of 2 years from the following advantages:
- material verification once or twice a year
- warranty extension
- telemaintenance
- telephone assistance +33 (0) 892 680 933 (0,282 € HT/min)
- material replacement on site or by return in our manufacture
- metrological certificates: verification of measurement accuracy
- access to new software versions and updates
- on-site intervention time within 3 open days after problem identification by our experts
VIII. ENVIRONMENT PROTECTION
JRI recommends to our customers to throw away their measuring and recording devices which are unserviceable
and/or beyond repair in a way that is appropriate to environment protection. As the production of waste cannot
be avoided, it is best to re-use them by proceeding with adapted recycling depending on the material used and
considering the environment protection.
RoHS Directive
The ROHS European Directive rules and limits the presence of hazardous substances in electrical and electronic
equipments (EEE).
In the article 2, the scope of this Directive excludes "9. Monitoring and Control Instruments" and our products are
part of this category.
Nevertheless, our company has decided to apply the whole dispositions of this Directive for all our new electronic
devices which will comply to this 2002/95/CE Directive.
Table of contents
Other JRI Modem manuals
Popular Modem manuals by other brands

Comrex
Comrex NX Connect Series product manual

Alcatel
Alcatel One Touch X715 Service manual

Motorola
Motorola SBG6580 Series Brochure & specs

UCONNECT INTERNATIONAL
UCONNECT INTERNATIONAL WA-485E user manual

Motorola
Motorola SURFboard SB4000 user guide

Comtrend Corporation
Comtrend Corporation NL-3120 Installation & setup