I. INTRODUCTION............................................................................................................................................................3
a) Equipment .................................................................................................................................................................................3
b) Symbols.....................................................................................................................................................................................3
II. PRESENTATION............................................................................................................................................................3
a) Display.......................................................................................................................................................................................3
b) Complementary information....................................................................................................................................................3
III. SPY RF USE..................................................................................................................................................................4
a) Stop............................................................................................................................................................................................4
b) Start............................................................................................................................................................................................4
c) Finding right places of spy RF recorders...............................................................................................................................4
d) Finding right places of Spy RF RelaY.....................................................................................................................................4
e) Installation ending.................................................................................................................................................................... 5
IV. BATTERY REPLACEMENT...........................................................................................................................................5
V. RESET............................................................................................................................................................................5
VI. FEATURES....................................................................................................................................................................5
VII. WARRANTY...................................................................................................................................................................6
VIII. MAINTENANCE CONTRACT........................................................................................................................................6
IX. ENVIRONMENT PROTECTION.....................................................................................................................................6

©JRI 3
I. INTRODUCTION
Congratulations, you own SPY RF TesT ! With its software, with the Spy RF ModeM TesT this device enables you to
determine precisely the position of your SPY RF recorders in an installation.
Indeed, the presence of obstacles (walls, partitions, furniture, people, diverse objects…) on the radio waves path between a
modem and a recorder weakens the signal, what could disturb an effective radio transmission. The nature and thickness of
crossed walls must be taken into account. It is to notice that the thickness of an obstacle should be measured in the radio
signal direction: it is harder for a radio signal to cross a wall obliquely than perpendicularly.
a) Equipment
1 SPY RF Test
1 User manual
b) Symbols
II. PRÉSENTATION
a) Display
b) Complementary information
RECYCLING : do not throw in a rubbish dump or in a domestic waste container. Comply to the regulation to throw away the device.
POWER SUPPL
Y
: this device is powered by a cotinuous current delivered by a main power supply adaptor (230VAC). Comply to the
security and utilization regulations of electric power. Use a an electric installation complying to these regulations
CE MARKING :this equipment is certified to comply with the European regulation for the electric security, inflammability, disturbing
radiation emission and immunity to surrounding electric disturbances.
FCC ID: W45 03330
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation
In accordance with FCC requirements, changes or modifications not expressly approved by JRI could void the user's
authority to operate this product.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense
Low battery. You must change it.
Pushbutton
Dis
p
la
y
Battery
cover
Indication of the radio reception
level
In %
Bar graph

©JRI 4
III. SPY RF USE
a) Stop
At reception, the SPY RF TesT is stopped. To activate it, you have to press on the button.
b) Start
To stop the SPY RF TesT, please press twice again the pushbutton.
c) Finding right places of spy RF recorders
Plug the Spy RF ModeM on the main power. The green led must light on.
Turn on the Spy RF TesT. The green light must light on.
Look for the best position (> 80%) according to the screen indications . Repeat the operation as many times as
necessary, depending on the number of recorders you have to place. If the level is below 80%, find another
position or if it will be necessary to use a Spy RF RelaY.
d) Finding right places of Spy RF RelaY
Plug the Spy RF ModeM on the main power. The green led must light on. Press the button on the side of the
ModeM to switch the power to 500mW; The red led must light on
Turn on the Spy RF Test and then press the pushbutton to switch the power to 500mW. The red led must light on
Look for the best position (> 80%) according to the screen indications. Repeat the operation as many times as
necessary, depending on the number of Spy RF RelaY you have to place regarding the position of the Spy RF
RelaY.
Once the position determined, move the ModeM Spy RF TestT to this position and search the position of the Spy
RF recorders (see III 3).
If the level is below 80%, it is necessary to use a 2nd Spy RF RelaY, so repeatthe section (III 4)
Maximum reception level
The green led lights continuously. The Spy RF
TesT receive in 25mW
(
like an
y
Sp
y
RF except
Spy RF RelaY)

©JRI 5
1
2
3
2
a
a) Unplug the battery connector.
b) Short circuit the 2 pins with a screwdriver
c) Connect the new battery
d) Change the seal
e) Close the battery cover
Never unscrew.
This will cancel the
warrant
y
1
3
Open the
batter
y
cover
b
e) Installation ending
Once all you recorders are installed, you have to stop the SPY RF TesT by pressing on its pushbutton.
IV. BATTERY REPLACEMENT
When the SPY RF battery has to be replaced, the LCD screen displays the following message:
To replace the battery, follow the instructions below:
V. RESET
If the device does not work anymore (cannot turn it on…), use the Reset function in the same way as the battery change.
VI. FEATURES
FEATURES SPY RF TesT
Operating conditions -30 +70°C
Température of storage -40 + 85°C
Radio band 868MHz or 902MHz
Battery lifetime 2 ans
Dimensions 123x69x30mm
Protection degree IP65
CE ERM Compliance EN 301 489 / EN 61000 / EN 61010 / EN 55022 / EN 300 220
FCC Compliance FCC part 15
KEEP THE BATERY FAR FROM THE FIRE ; DO NOT TRY TO RELOAD OR TO SHORT CIRCUIT IT. USE ONLY BATTERIES
SUPPLIED BY JRI (REF 06569)
!

©JRI 6
VII.WARRANTY
JRIproducts carrya oneyear warrantyand guarantee against defects in their componentsor workmanship.
During this period if any product supplied by the Company proves on inspection to be defective, the Company will at its own
optionreplace thesame orrefund tothe Buyerthe priceof theproduct.
Inno circumstanceswill JRI'liability exceedthe priceof theproduct paidby the buyer or the cost of replacement.
JRI shall not in any event be liable to the Buyer for any indirect or consequential loss or damage costs or expenses whatsoever
whichmight ariseout ofor inconnection withthesupply ofthe productor itsconsequent use.
Consequently, the products warrantee and guarantee specified above, does not cover damage caused by fair wear and tear,
abnormal storage conditions, incorrect use, accidental misuse, abuse, neglect, misapplication or modification, or use with non-
JRI' hardware/software. No warranty of fitness for a particular purpose is offered and the user assumes the entire risk of using
theproduct.
Inline withour policyof continuousdevelopment, wereservethe rightto amendour productspecification withoutprior notice.
VIII. MAINTENANCE CONTRACT
How to optimize your radio frequency installation?
RF measuring systems communicate by radio frequency. However, there may be several factors that can modify the radio
ways already defined, such as moving from a building, adding walls, … Radio frequency requires thus a periodical follow up
performedby specialists.
That’s why JRI has created maintenance contracts. We bring you a global solution which makes your maintenance easier. This
overall service offer includes maintenance and also metrological services, which ensure you that your system is fully
performant.
You won’t worry about your devices maintenance anymore !
Withthis maintenancecontract youwill benefit fora minimalperiod of 2 yearsfrom the following advantages:
-material verificationonce ortwice ayear
-warranty extension
-telemaintenance
-telephone assistance+33 (0) 892 680 933 (0,282 € HT/min)
-material replacementon siteor by returnin ourmanufacture
-metrological certificates:verification of measurement accuracy
-battery change
-access tonew softwareversions andupdates
-on-site interventiontime within3 opendays afterproblem identificationby ourexperts
IX. ENVIRONMENT PROTECTION
JRI recommends to our customers to throw away their measuring and recording devices which are unserviceable and/or
beyond repair in a way that is appropriate to environment protection. Insofar as the production of waste cannot be avoided, it is
best to re-use them by proceeding with adapted recycling depending on the material used and considering the environment
protection.
RoHS Directive
The ROHS European Directive rules and limits the presence of hazardous substances in electrical and electronic equipments
(EEE).
In the article 2, the scope of this Directive excludes "9. Monitoring and Control Instruments" and our products are part of this
category.
Nevertheless, our company has decided to apply the whole dispositions of this Directive for all our new electronic devices which
willcomply tothis 2002/95/CEDirective.
Table of contents
Other JRI Modem manuals