1
Introduction
The RS125 is a versatile, fully programmable Intruder Alarm Control Panel which will have been
set up by your Alarm Company to serve your particular requirements. However there must be
at least one person on the premises who takes a special interest in the alarm system. This
person, whom we call the System Manager should read this guide carefully in order to get the
best performance from the system.
The System Manager needs to work in conjunction with the other Users, the Alarm Company
and also possibly an Alarm Receiving Centre to ensure that security is maintained and that
alarm activations are properly managed. The management approach depends on the size of the
system, whether it is a residential or commercial application and also whether a Split System is
being used. This manual provides separate Setting instructions for a Single Area Residential
System and a Split System; with either type of installation you need only read the relevant
sections.There is an Organisation Plan for the System Manager in Appendix 1 which covers both
types of installation and a Specification inside the Rear Cover..
The system is operated from one or more Remote Keypads, incorporating a backlit Text
Window which provides the user with an easily interpreted series of messages while setting and
programming the system. Operation is driven through a series of menu displays which allow
most routine functions to be achieved without reference to the manuals.
The RS125 allows up to 100 different Users to be provided with individual Access Codes each
with their own User ID, Rank, Name Text and Area Authorisation Tags. The Rank of each
Access Code is used to determine the level of access to the system:-
Master: This is normally assigned to the System Manager and allows access to all the RS125
User Menu Options. Only one Master Code is allowed and this is allocated the User
ID zero, zero, (00). The Master Code can be used to re-program all codes and has
access to all Areas. You will be told the Master Code when the Alarm Company
hands over the system.
Boss: Boss Codes are set up using the Master code; they allow access to all the RS125 User
Menu Options but cannot be used to change either the Master Code or another
Boss’s code parameters. Boss Codes can be used to set up lower ranking Users.
User +: User+ Codes may Set and Unset pre-defined Areas and Omit zones in those areas.
User: User Codes may only Set and Unset pre-defined Areas.
Keyholder: This code allows a Guarding Company to switch the alarm off and rearm the system
only after an alarm activation has occurred; it is valid for all Areas.
Duress: A special Access Code used to generate a silent call to the Alarm Receiving Centre.
A normal Access Code must be used to reset the system.
Engineer: This code is only accessible to the Alarm Company for engineering use.
The RS125 does not provide any means of revealing the Access Codes to anybody.