WarrantyTermsandConditions
YourGreyWaterGatorMaxi100iscoveredbya1yearreturntobasewarranty
Ifanypartshouldfailotherthanthemainpititshouldbereturnedtothe
manufacturerforinspection.
Warrantycommencesfromdateofpurchase.
Unitmustbeinstalledbyalicensedplumberorqualifiedinstaller.
Incorrectoperationofunitisnotcoveredbywarranty.
Labourandshippingforwarrantyclaimsarenotcoveredinthetermsofthisdocument
Damagesincurredtopropertyorpersonsbyincorrectoperationorinstallationarenot
coveredbythiswarranty.
Pleaseprovideproofofpurchasewithallwarrantyclaims.
Ourtotalliabilityunderanywarrantyislimitedtoreplacingthedefectiveordamaged
goodsorrefundingthepurchaseprice.
Weshallnotbedeemedliableforanylossbeyondourcontrol,orforanyindirector
consequentiallossofanykind
ACN 124 112 705
18RayleighAvenue
QUEENSCLIFFVictoria3225
Ph0352585193
Fax0352585193
Email:sales@justwatersolutions.com.au
www.greywatergator.com
InstallationandOperatingInstructions
Grey Water Gator Maxi 100
WMKT22111

GuidelinesfortheGREYWATERGATORMAXI100
YourJustWaterSolutionsGreyWaterGatorMaxi100™isspecificallydesignedfor
GreyWaterreusefromthelaundry,showerandbathwastewater.
YourGreyWaterUnitmustbeinstalledbyalicensedplumberinaccordance
withregulationsAS/NZ3500.2.2.2003
DonotconnecttoakitchensinkorToiletasthisisclassedasBlackWaterand
isnotsuitableforthisunitorforreuse.
OnlyconnecttosubsurfaceirrigationsuchasGreyWaterDriptubeorsullage
drainpipe.
WerecommendthatyoualsocheckwithyourlocalWaterAuthorityforapprovalof
thistypeofSeasonalUseGreyWaterDiversiondevice.
Itismandatorythatthepowercircuittothisunitisprotectedbyaresidualcurrent
circuitbreakerandwehighlyrecommendasurgeprotectiondevicebefittedaswell.
YourGreyWaterUnitispreassembled.Pleasecheckthecontentsondeliveryasin‐
transitdamagemayoccur.
INSTALLATION
Thisunitmustbeinstalledbyalicensedplumberandorserviceagent.Failureto
complywillvoidthewarranty
1.Yourplumber/installerwillinstallorlocateyourdedicatedGreyWater
Wastepipes.
2.Allowapprox350mmfromgroundleveltocut‐inpointInletpipe.
3.Ifyourpipeworkisdeeperthanthis,optionalrisersof200mmareavailable.
4.Theoverflowpipemustbeconnectedtoasewerdischargepointsuchasa
gullytrap.
5.Excavateasuitableareaapprox800mmdeep1000mmlongand600mm
wide.
Allowenoughroomforconnectiontopipework,electricalcableandconduit.
6.Makesurethebaseislevelusingfreeflowingpackingsand.Taketimetolevel
theunitandsetthecorrectheightsforthepipework.
7.Connectthepipe‐workmakingsuretheinletandoverflowpipesarecorrectly
plumbed,inaccordancewithAS3500.
8.Astheunithasaleadanda3pinplug,havealicensedelectricianinstalla
suitablepoweroutletadjacenttheunit.Makesuretheelectricalcableis
protectedatalltimes,andobserveelectricalregulationsinyourstate.
9.Connectthe25mmnon‐returnvalvetothedischargeoftheunit.
10.Connectthe25mmLilacpipe‐worktoyourirrigationsystem.
11.Afterallconnectionsarecompletedtotheregulationsyoucanbackfillthe
surroundingvoidwithsuitablematerial.(Freeflowingsandispreferred)Do
notbackfillwithsharporbrokenrocksthatmaydamageordistorttheunit.
12.Inspectthepittomakesureitisfreeofsandanddebristhatcoulddamage
thepump.
13.Youcantesttheoperationbyfillingwithwaterandobservingthewaterlevel,
SchematicDrawing
GreyWaterGatorMaxi100
1GreyWater Gator Maxi 100Pit 12 25mm Tank Inlet Fitting
2Lilac Lid for Pit 13 Pump Controller Complete
3Key for lid 13b Magnetic Float switch
4Blue Sub 15 High HeadPump 14 SS 6mm Allen Bolts
5Filter set of 5 14a Mounting Plate for Controller
6Riser Pipefor pump 15 100mm Wallace seals
725mm Socket 16 100mm Bend M&F
825mm Threaded Pipe 17 100mm Pipe Piece x155mm
925mm Swivel Elbow 18 100mm Diverter Valve
10 25mm Hex Nipple 19 Cable Gland
11 25mm Female Elbow 20 Watermark Approval Sticker

11.Donotpumptheresidualthroughtheirrigationsystem.
12.Onceeverythingiscleanedyoucannowreinstallthefilterstothetank
takingcaretofitthembackthesameastheywereremoved.
13.Youcanfilltheunitwithcleanwatertocheckoperationoffloatsanduse
thatcleanwatertoflushtheirrigationsystem.
14.Onceyouarehappytheunitisoperatingcorrectlyliftthehandleonthe
bypassvalvetoopentheflowintotheunit.
15.Refitthetopcoverandlockthelidwithyourkey.
16.Yourunitisnowservicedandreadyforoperation.
Atthistimeitisgoodpracticetocheckoveryourirrigationsystem.
Turnonthedrainvalvesattheendofyourirrigationlinesandremoveany
sedimentthatmayhaveaccumulatedinthepipes.Checkforanyleaksor
damagetotheirrigationpipework.Repairasnecessary.
PumpSpecificationsGREYWATERGATORMAXI100
YourGreyWaterGatorMaxi100unitisequippedwithaspeciallyselectedsingle
stagehighheadpumptohandlealmosteverydemandthataGreyWaterSystem
canhave.
Thispumpiscontrolledbyaninternalelectroniccontrolwhichstartsandstops
thepumpviaahighandlowmagneticfloatswitch.
Italsoisprogrammedtooverridethefunctionofthehighfloatswitchatleastonce
ina24hourcycle.
Thiswillensuretherewillbelittleornoresidualwaterremainingintheunit.
Noelectricalconnectionsarerequiredintheunititselfotherthananexternal
powerpointneartheunit.
Pumpperformancetable:
Maximumflowof140l/mat1metrehead.
Ratedflowof80l/mat10metreshead.
Maximumheadof14.5metres.
Maximumcurrent750watts240volt.
Warrantyis12monthsreplacement,onconditionthatitisreturnedto
placeofpurchase,withproofofpurchase.
14.MakesurethediversionvalveisopenallowingGreyWatertoflowintotheunit.
15.Turningonafixtureinsidethehousethatisconnectedtothegreywater
pipe‐workwillallowGreywatertoflowintotheunit.
16.Turnonthepowerbrieflyandcheckthepumpisoperatingcorrectly.The
IrrigationSystemisnotconnectedatthisstage,thiswillallowtheunittobe
flushedout.
17.Installationoftheirrigationsystemcannowtakeplace
18.Yourunitisnowcommissionedandreadyforuse.
Additionalnotes
Ifamanifoldisusedontheirrigationsystem,atleastonevalvemustbeopenatall
timestopreventthepumpoperatingatclosedhead,thatisano‐flowcondition.
Operationundertheseconditionswillvoidthewarranty.
Minimumpipesizefromtheunitis25mm.Using25mmLilaclowdensitypolytubeor
25mmPVCpipeisrecommended.
Troubleshooting
WaterdoesnotflowintotheunitCheckthebypassvalve,makesurethehandleis
Intheraisedposition.
Theunitisfullbutthepumpisnotoperating
Checkifpumpisconnectedtothepower
sourceandcheckifpowerisavailable.
Thepumpshouldautomaticallystartwhen
waterreachesthehigherfloatswitch. Ifpump
doesnotstart,cleanthetopfloatswitchand
testagain.
Thepumpcannotmaintaintherateof
Inflowingwater.
Checktoseeifirrigationsystemissized
correctly.
Atleast100MetersofTirandriptubeshouldbe
connectedtotheirrigationsystemasper
Irrigationinstructions.Theoutflowshouldbe
equaltotheinflow.Alsocheckforkinksor
Blockagesinpipeworkfromunit.
Thepumpsectionisemptywhilethewater
levelishighoninletside
Serviceandcleanthefiltermediatomaintain
flow.
GreyResidualisbuildinguparoundthe
Pump
Checkthefiltermedia,makesureitisseated
correctly andthattherearenovoidsunder
thefilterswhichwillcausebypassaround
them.
Offensiveodoursarereleasedfromyourunit Thoroughlycleantheunitandthefiltermedia.
Fillwithfreshwaterandpumpoutthrough
Irrigationsystem.

DISTRIBUTIONOFDIVERTEDGREYWATER
CurrentGovernmentRegulationsstatethatyoumustdisperseuntreatedgrey
waterviaaSubsurfaceirrigationsystem.
YoumustuseanapprovedirrigationsystemthatisspecificallydesignedforGrey
Water.
RecommendationsandGuidelinesforirrigationsystem:
ThearearequiredforyourIrrigationsystemdependsonthesoiltype.Thechartbelow
showsthesuggestedspacingrequiredbetweendripperlinesfordifferentsoiltypes,in
relationtothetotalarea.Minimumpipesizefromtheunitis25mmPVCorLow
Densitypolytube.
Makesurethemaximumlengthofdriptubeis20metresfromthemainline
SoilTexture&StructureandDripperlineandrowspacing
Arearequiredperperson*inhousehold(m2)
1‐2‐3‐4‐5‐6Persons
RecommendedFeatureSetbackdistance(metres)
Propertyboundaries,pedestrianpaths,driveways:1metre
Footingsofbuildings:1.5metre
Retainingwallfooting:1metre
Ingroundswimmingpoolsurrounds:1metre
Ingroundpotablewatertank:6metres
Boresintendedforhumanconsumption:30metres
Pleasealsorefertoyourlocalauthorityforregulationsastheserequirementscanvary
fromareatoarea.
WARNINGSANDPRECAUTIONSFORGREYWATERREUSE
DonotconnectyourGreyWaterMaxitoyourkitchensink,dishwasherora
toiletsystem.ThisisallclassedasBlackwaterandmustgotosewerorseptic
waste.
Whenwashingitemssuchassoilednappies,pleaseswitchyourdiversionvalve
todivertdirecttothesewerageorsepticsystem.
SoilTypesSpacing123456
Gravel and Loams x.06m 30 60 90 120 150 180
Sandy Loams x 0.6m 30 60 90 120 150 180
Loams x 0.8m 40 80 120 160 200 240
Clay Loams x 0.9m 45 90 135 180 225 270
Light Clays x 1.0m 50 100 150 200 250 300
Medium to Heavy x 1.5m 75 150 225 300 375 450
DonotdistributegreywaterfromyourGreyWaterMaxiunitviasprinklersor
allowforairbornedispersion.
Onlyirrigatewhennecessaryandswitchunittodivertwhenraining.
DonotletdivertedGreywatertorunofftoneighbouringproperties.
Donotleaveunitunattendedwhencarryingoutmaintenanceorwhenthe
coverisremoved.
Incaseofextendedperiodsofnonoperationitisadvisedtocompletea
serviceandcleanoftheunittoavoidthepossibilityofdryingoutthesludge
onthefilters.
MAINTENANCEOFYOURGREYWATERUNIT
YourGreyWaterGatorMaxihasbeendesignedforminimummaintenance.
Duetothehighflowcapabilitiesofthe3dimensionalfiltersyoushouldonlyneedto
cleanyourunitafterapproximately40,000+litresofflowthrough.
Dependingofthenumberofoccupantsandtheamountofwaterflowingthrough
yourunitthecleaningcyclewillbebetween180–360days.
Yourfiltersstillwillkeepworkingevenuptomaximumcapacity.
Someheavyloadsituationsmayrequireservicingyourunitonamorefrequentbasis.
Ifyouareconsideringnotusingyourunitforanextendedperiodoftimesuchasafew
months,pleasecarryoutafullserviceandcleanbeforedecommissioning.Thiswill
keepyourunitinoptimumconditionandeliminatebacteriabuildup.
Whenservicingandcleaningyourunitwerecommendthatyouwearprotective
rubberglovesandavoidskincontactasmuchaspossible.
1.Werecommendthataregisteredserviceagentcarryoutthemaintenanceto
thisunit.
2.Turnoffallpowertotheunit.
3.Removethelidwithyourkeyprovided.Bemindfulofanychildrenorpets
thatcouldaccidentallyfallintotheunitwhileservicing
4.Setthebypassvalvetotheclosedbypassposition.Thiswillprevent
Greywaterenteringtheunitwhileyouareworkingonit.
5.Youcannowaccessthefiltermedia.
6.Removerthefilterpadseitheroneatatimeortogether.
7.Takethefilterstoasuitableareaforcleaning.
8.Rinseofffiltersusingahandnozzlefromadomesticsupply.Washbothsides
untilreasonablyclean.NBthefiltersdonothavetobespotless.
9.DonotuseHighPressureCleaningequipmentonyourfiltermedia.
10.Atthistimerinsethepitandpumpandremovetheresidualwithaseparate
sumppump,orspongetheremainingresidualfromtheunit.
Popular Water Filtration System manuals by other brands

Wateranywhere
Wateranywhere AAA-RO50PW MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE

STA-RITE
STA-RITE Swimming Pool Filter owner's manual

Separ Filter
Separ Filter SWK-2000/40/WSA operating manual

Klimawent
Klimawent STRONG-2000-N Use and maintenance manual

SpectraPure
SpectraPure The Producer System Installation and operating manual

Kessel
Kessel EasyClean Installation and operating instructions

Unilever
Unilever pureit UR5640 instruction manual

CWR
CWR GS2 Installation Guide and Technical Information

Premier
Premier WP-4V Installation, operation and maintenance manual

Litree
Litree LUSA1-1C user manual

Nikken
Nikken PIMAG AQUA POUR EXPRESS Quick reference sheet

PURAPOOL
PURAPOOL PURACHLOR BLU Series INSTALLATION INSTRUCTIONS & PRODUCT MANUAL