9
8.TALLY(RESPONSE)DATA
The Projector will only accept and process data when the ID number included with the data coincides with
the ID-number registered to the Projector itself. (Except when ID = ‘0’) If the received ID-number
matches the Projector’s ID, it will return a response to the query from the external control unit. This
response data is called "Tally (Response) Data". (However, when ID = ‘0’, tally (response) data is not
replied.)
The Tally (Response) Data is normally returned within 3 seconds after the data is received.
There are some exceptions, however (e.g. POWER command)
After transmitting data, the external control unit cannot transmit subsequent data until the Tally
(Response) Data is received. However, if Tally (Response) Data is not returned within 3 seconds after
transmitting the data (there are some exceptions such as the POWER command), data transmission can
be retried.
8.1 Tally (Response) Data Status
8.1.1 Normal Termination Status
Character HEX Definition
‘0’ 30 Command received and processing terminated
8.1.2 Status when Error Occurs (Error Status)
Character HEX Definition
‘A00’
41H 30H 30H Command not supported
‘A01’
41H 30H 31H Invalid parameter
‘A02’
41H 30H 32H Parameter value exceeds operation range
‘A03’
41H 30H 33H Unclassified error
Unacceptable command in current mode
‘A04’
41H 30H 34H or
Unacceptable command with current setting
‘A05’
41H 30H 35H Command cannot be accepted if no signal.
‘A0A’
41H 30H 41H Time-out occurred with the communication with sub
microcomputer
‘A0B’
41H 30H 42H Error occurred with the communication with sub
microcomputer
8.2 Tally (Response) Data Parameter
The Tally (Response) Data Parameter is returned when the Tally (Response) Data is issued in
response to a query (request for data). No parameter is returned when Tally (Response) Data
issued in response to a command or when an error occurs.