JVC MX-KA6 Series User manual

MX-KA6
Contents
COPYRIGHT ©2003 VICTOR COMPANY OF JAPAN, LTD. No. MB028
Aug. 2003
Safety precautions ---------------------------- 1- 2
Preventing static electricity ----------------- 1- 3
Important for laser products ---------------- 1- 4
Disassembly method ------------------------ 1- 5
Adjustment method -------------------------- 1- 18
Flow of functional
operation until TOC read -------------- 1- 20
Maintenance of laser pickup -------------- 1- 21
Replacement of laser pickup -------------- 1- 21
Description of major ICs ------------------- 1- 22
CA-MXKA6SP-MXKA6 SP-MXKA6
Area Suffix
UW ............. Latin America
MX-KA6
SERVICE MANUAL
COMPACT COMPONENT SYSTEM
Wiring connection ---------------------------- 1- 33

MX-KA6
1-2
Warning
!
CAUTION
Good earth ground
Place this
probe on
each exposed
metal part.
AC VOLTMETER
Having 1000
ohms/v
1500 10W
olts,
or more sensitivity)
0.15 F AC TYPE
Safety Precautions
1. This design of this product contains special hardware and many circuits and components specially for
safety purposes. For continued protection, no changes should be made to the original design unless
authorized in writing by the manufacturer. Replacement parts must be identical to those used in the
original circuits. Services should be performed by qualified personnel only.
2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the
product should not be made. Any design alterations or additions will void the manufacturer's warranty
and will further relieve the manufacture of responsibility for personal injury or property damage
resulting therefrom.
3. Many electrical and mechanical parts in the products have special safety-related characteristics. These
characteristics are often not evident from visual inspection nor can the protection afforded by them
necessarily be obtained by using replacement components rated for higher voltage, wattage, etc.
Replacement parts which have these special safety characteristics are identified in the Parts List of
Service Manual. Electrical components having such features are identified by shading on the
schematics and by
!
) on the Parts List in the Service Manual. The use of a substitute replacement
which does not have the same safety characteristics as the recommended replacement parts shown in
the Parts List of Service Manual may create shock, fire, or other hazards.
4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be
separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention
of electric shock and fire hazard. When service is required, the original lead routing and dress should
be observed, and it should be confirmed that they have been returned to normal, after re-assembling.
5. Leakage currnet check Electrical shock hazard testing)
After re-assembling the product, always perform an isolation check on the exposed metal parts of the
product antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.)
to be sure the product is safe to operate without danger of electrical shock. Do not use a line isolation
transformer during this check.
Plug the AC line cord directly into the AC outlet. Using a "Leakage Current Tester", measure the
leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part
having a return path to the chassis, to a known good earth ground. Any leakage current must not
exceed 0.5mA AC r.m.s.)
Alternate check method
Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or
more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-
type capacitor between an exposed metal part
and a known good earth ground. Measure the AC
voltage across the resistor with the AC voltmeter.
Move the resistor connection to each exposed
metal part, particularly any exposed metal part
having a return path to the chassis, and meausre
the AC voltage across the resistor. Now, reverse
the plug in the AC outlet and repeat each
measurement. Voltage measured Any must not
exceed 0.75 V AC r.m.s.). This corresponds to 0.5
mA AC r.m.s.).
1. This equipment has been designed and manufactured to meet international safety standards.
2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.
3. Repairs must be made in accordance with the relevant safety standards.
4. It is essential that safety critical components are replaced by approved parts.
5. If mains voltage selector is provided, check setting for local voltage.
Burrs formed during molding may be left over on some parts of the chassis. Therefore,
pay attention to such burrs in the case of preforming repair of this system.

MX-KA6
1-3
Preventing static electricity
1. Grounding to prevent damage by static electricity
Electrostatic discharge ESD), which occurs when static electricity stored in the body, fabric, etc. is
discharged, can destroy the laser diode in the traverse unit optical pickup). Take care to prevent this when
performing repairs.
2. About the earth processing for the destruction prevention by static electricity
In the equipment which uses optical pick-up laser diode), optical pick-up is destroyed by the static electricity
of the work environment.
Be careful to use proper grounding in the area where repairs are being performed.
2 1 Ground the workbench
Ground the workbench by laying conductive material such as a conductive sheet) or an iron plate over it
before placing the traverse unit optical pickup) on it.
2 2 Ground yourself
Use an anti-static wrist strap to release any static electricity built up in your body.
3. Handling the optical pickup
1. In order to maintain quality during transport and before installation, both sides of the laser diode on the
replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition.
Refer to the text.)
2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power
source can easily destroy the laser diode.
4. Handling the CD changer unit (optical pickup)
1. Do not subject the CD changer unit optical pickup) to strong shocks, as it is a sensitive, complex unit.
2. Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific
details, refer to the replacement procedure in the text.
Remove the anti-static pin when replacing the CD changer
unit. Be careful not to take too long a time when attaching it
to the connector.
3. Handle the flexible cable carefully as it may break when
subjected to strong force.
4. It is not possible to adjust the semi-fixed resistor that
adjusts the laser power. Do not turn it.
Attention when traverse unit is decomposed
*
Please refer to
“
Disassembly method
”
in the text for
pick up and how to detach the CD changer mechanism.
1. Remove the CD changer unit.
2. Disconnect the harness from connector on the CD motor
board.
3. Solder is put up before the card wire is removed from connector
Cn601on the main board as shown in Fig.1 and Fig. 2.
When the wire is removed without putting up solder, the
CD pick-up assembly might destroy.)
4. Please remove solder after connecting the card wire with
CN601 when you install picking up in the substrate.
Conductive material
conductive sheet) or iron plate
caption)
Anti-static wrist strap
Soldering
Fig.2
Flexible cable
Fig.1
CD changer
unit

MX-KA6
1-4
1. CLASS 1 LASER PRODUCT
2. DANGER :
Invisible laser radiation when open and inter
lock failed or defeated. Avoid direct exposure to beam.
3. CAUTION :
There are no serviceable parts inside the
Laser Unit. Do not disassemble the Laser Unit. Replace
the complete Laser Unit if it malfunctions.
4. CAUTION :
The compact disc player uses invisible
laser radiation and is equipped with safety switches
which prevent emission of radiation when the drawer is
open and the safety interlocks have failed or are
defeated. It is dangerous to defeat the safety switches.
Important for laser products
FUSE CAUTION
CAUTION:
REPLACE WITH SAME TYPE
AND RATING FUSE S).
ATTENTION:
REMPLACER PAR UN LES)
FUSIBLE S) DE MEME TYPE
ET DE MEME VALEUR
5. CAUTION :
If safety switches malfunction, the laser is
able to function.
6. CAUTION :
Use of controls, adjustments or performance
of procedures other than those specified herein may
result in hazardous radiation exposure.
!
CAUTION Please use enough caution not
to see the beam directly or touch
it in case of an adjustment or
operation check.

MX-KA6
1-5
Disassembly method
Commence disassembly of the set by removing the main units and then proceed to the components
and assemblies inside the units.
Replacement of the fuses and the power IC
Top cover
CD changer unit
Front panel assembly
Chassis unit
CD changer unit
Removing the main PCB
Removing the CD changer mechanism assembly
Removing the CD pickup
Replacing the loading motor and belt of the CD changer tray
Replacing the CD tray rotor belt of CD changer, and removing the motor
Front panel assembly
Removing the cassette deck mechanism
Removing the earphone jack PCB
Removing the control/FL PCB
Removing the switch PCB and ACTIVE BASS EX. switch PCB
Removing the cassette deck main motor, and replacing the main belts
Removing the leaf switches of the cassette deck mechanism
Removing the cassette deck heads
Chassis unit
Removing the 3-pin regulator
Removing the power amp and supply PCB and the Power Trans PCB
Removing the sub power PCB

MX-KA6
1-6
<Disassembly of the main blocks of the set>
Replacement of the fuses and the power IC
Replacing the fuses (See Fig.1)
Prior to performing the following procedure, remove
the top cover.
1. Replace the fuses inside.
[Caution]
Be sure to use fuses with the specified
ratings.
Replacing the heat sink cover (See Fig.3)
1. Remove four screws
B
from the rear panel.
2. Pull the heat sink cover outward.
Fig.1
Replacing the power IC (See Fig.2)
Prior to performing the following procedure, remove
the top cover.
1.
Remove the two screws A from the heat sink between
the power IC.
2. Remove the solder fixing the power IC.
A
Fig.2
Fig.3
B
Fuse F952)
T3.15A 250V
Fuse F951)
T1.6A 250V
Fuse F953)
T1.25A 250V

MX-KA6
1-7
Removing the top cover
(See Fig.4 and 5)
1. Remove six screws
C
that retain the top cover from
the panel rear of the body.
2.
Remove six screws
D
that retain the top cover from
the two sides of the body.
3. Remove the top cover from the body by lifting it
toward the rear.
Fig.5
Fig.4
Right Front panel assembly
D
D
Left Front panel assembly
D
D
Top cover
C
C

MX-KA6
1-8
Fig.6
CD tray panel
Fig.9
CD changer
unit
G
Fig.7
CD tray panel
Fig.8
Removing the CD changer unit
(See Fig.6 to 9)
Prior to performing the following procedures, remove
the top cover.
[Caution]
Although the CD mechanism unit can be
removed without removing the CD tray
panel, it is still recommended to remove it
in order to prevent damage.
a. From the front panel side of this set, push in the
sections marked with arrows and pull out the CD
tray toward the front.
b. Remove the CD tray panel by pushing both of
its extremities upward in the direction of the
arrows.
c. Push the CD tray deep into the set.
1.
Disconnect the cord wires from the CD PCB CN703
and CN203.
2.
From the rear of the set, remove two screws
E
three screws
F
and four screws
G
on the front
panel left and right side.
3. Handle the CD changer unit rear, take out the unit.
F
Antenna
termianl
E
Aux
terminal

MX-KA6
1-9
Removing the front panel assembly
(See Fig.10 to 11)
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
1. Disconnect the parallel wire and the cord wire from
the connectors CN701, CN101 on the power amp.
PCB.
2. Remove one screws
H
retaining the front panel
assembly onto the bottom of the body.
3. Remove two screws I on the left and right side of the set
retaining the panel front from the bottom and then
remove then GND lug
b
that comes from the power
amp and supply PCB.
4. Disengage the claws
c
on both sides of the front
panel assembly and then remove the assembly.
Fig.10
H
Fig.11
I
er amp andPow
supply PCB
Claw
c
GND lug
b

MX-KA6
1-10
Fig.13
CD PCB
Short round
CN601
Fig.12
J
CD PCB
<Disassembly of units and assembly
inside this set>
Removing the CD PCB
(See Fig.12 to 13)
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
1. Disconnect the wires from CN603A, CN603B and
CN604 on the CD PCB, which is located on the
back side of the CD changer unit.
2. The four screws
J
that retain the CD PCB should be
removed.
3. Remove the CD PCB by pulling it toward the side
where the CN601 is located.
4.
Using solder, short the CD pickup to connect to
short round.
[Caution]
After re-connecting the wires, be sure to
remove the shorting solder from the GND
connection.
5. Disconnect the card wire from the connector CN601
on the main PCB and then remove the main PCB.
J
J

MX-KA6
1-11
Fig.14
Fig.15
assembly
e
Silver color)
e
copper color)
e
Silver color)
e
copper color)
d
CD changer
unit
Removing the CD changer mechanism
assembly (See Fig.14 to 15)
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
1. Turn the CD changer mechanism cover base and
remove the screws
d
connecting the unit to the CD
changer mechanism assembly.
2. Removing four screws
e
retaining the CD mechanism
holder assembly.
[Caution]
When replacing the CD changer mechanism
assembly, be sure not to mistake the positions
of the silver color and copper color spring.
CD changer
mechanism

MX-KA6
1-12
Fig.16
Fig.17
Fig.18
Motor locker
Turn table motor
Obligue gear
, and then remove the CD tray
g
M
L
f
CD pickup
Shaft
Removing the CD pickup (See Fig.16)
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
Also remove the CD changer mechanism.
1. Widen the section
f
.
2. While keeping the section
f
wide open, push the
section
g
in the direction of the arrow to remove
the shaft, and then remove the CD pickup.
Replacing the loading motor and rotor
belt of the CD changer (See Fig .17)
Prior to performing the following procedures, remove
the top cover.
Also open the CD changer tray.
1. Remove the two screws
L
retaining the CD
changer tray loading motor.
2. Remove the two screws
M
retaining the gear
plate and take it out, after remove the rotor belt
from the pulley.
Replacing the CD turn table and remov
ing the motor (See Fig. 19 )
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
1. Remove the one screws
N
retaining the CD Turn
table).
2. Remove the two screws
O
retaining the stopper
brackets on both sides of the CD changer unit.
3. Remove the stopper brackets from both sides of
the CD changer unit.
4. Pull out the CD tray from the CD changer unit, all
the way and lift the tray u/~ ward) to remove.
5. Remove the gear and after push out the tray motor
locker and pull out the tray motor from the CD tray.

MX-KA6
1-13
Fig.20
Fig.19
Z
Z
Front panel
assembly
P
Front panel
assembly
Earphone jack
PCB
Front panel
assembly
Q
Q
Control/FL
KEY 2
PCB
KEY 1
PCB
PCB
Fig.21
Removing the cassette deck mechanism
(See Fig.19)
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
Also remove the front panel assembly.
1. Remove six screws
Z
retaining the cassette deck
mechanism.
Removing the earphone jack PCB
(See Fig.20)
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
Also remove the front panel assembly.
1. Remove the screw with the washer,
P
that
retains the earphone jack PCB.
Removing the control/FL PCB
(See Fig.21)
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
Also remove the front panel assembly.
1. Remove six screws Q that retain the control/FL PCB
from the back of the front panel unit.

MX-KA6
1-14
Removing the switch PCB and sound
mode and CD function switch PCB
(See Fig.20 to 23)
Prior to performing the following procedures, remove
the top cover.
Also remove the CD changer unit.
Also remove the front panel assembly.
1. Pull out the volume control knob from the front of
the front panel assembly. Fig.22)
2. Remove six screws
Q
retaining the front panel
assembly. Fig.21)
3. Remove the control/FL PCB.
4. Remove eleven screws
R
retaining the switch key 1)
PCB. Fig.20)
5. Remove two screws
S
retaining the sound mode
and CD function key 2) switch PCB. Fig.21)
Fig.22
Fig.23
Volume knob
Front panel
assembly
Volume
shaft
Front panel assembly

MX-KA6
1-15
Fig.26
Cassette deck mechanism
Back side)
Solder side of leaf switch
Fig.24
t
Cassette deck mechanism
Front side)
Fig.25
Cassette deck mechanism
Back side) Cassette deck main motor
Main belt
For
A
cassette)
Main belt
For B cassette)
Removing the leaf switches of the cassette
deck mechanism (See Fig. 19 and 26)
Prior to performing the following procedures, remove
the top cover and both sides board.
Also remove the CD changer unit.
Also remove the front panel assembly.
1. Remove the six screws
Z
that retain the cassette
deck mechanism. Fig.19)
2. Remove the cassette deck mechanism.
3. Turn the cassette deck mechanism upside down.
4. Remove the solder from around the leaf switches.
5. Pull out the leaf switches from the front side of the
cassette deck mechanism.
Removing the cassette deck main motor,
and replacing the main belts
(See Fig.19, 24 and 25)
Prior to performing the following procedures, remove
the top cover and both sides board.
Also remove the CD changer unit.
Also remove the front panel assembly.
1. Remove six screws
Z
retaining the cassette deck
mechanism. Fig.19)
2. Remove the cassette deck mechanism.
3. Remove two screws
t
retaining the main motor from
the front side of the cassette deck.
[Caution]
After attaching the main motor, check the
orientation of the motor and the polarity of
the wires.
4. From the backside of the cassette deck, remove the
main motor and two main belts.
[Caution]
The lengths of the cassette A playback
only) and cassette B record/play) main
belts are different. When attaching the main
belts, use the longer belt for cassette
A
.

MX-KA6
1-16
Fig.28
AW
Fig.27
Cassette deck mechanism
Front side)
V U
PB Head REC/PB Head
V U
Removing the cassette deck heads
(See Fig. 19 and 27)
Prior to performing the following procedures, remove
the top cover and both sides board.
Also remove the CD changer unit.
Also remove the front panel assembly.
1. Remove six screws
Z
that retain the cassette deck
mechanism. Fig.19)
2. Remove the cassette deck mechanism and place
it so that the front side faces up.
3. Remove the solder from the bottom side of the
head terminal and disconnect the wire.
4. Remove screw
U
that retains the head.
5. Remove screw
V
that retains the head.
6. Hold the head and slide it in the direction of the
arrow to remove it.
Removing the 3 pin regulator and bridge
diode
(See Q904, Q907, D901, D914 and Fig.28)
Prior to performing the following procedures, remove
the top cover and both sides board.
1. Remove two screws
A
that connect the heat sink.
2. Remove two screws
W
that connect the heat sink.
3. Remove the solder fixing the the 3-pin terminal regulator
Q904, Q907.
4. Remove the solder fixing the 4-pin bridge diode
D901, D914).

MX-KA6
1-17
Removing the power amp and supply PCB
and the power trans PCB
(See Fig. 2, 29 to 31)
Prior to performing the following procedures, remove
the top cover and CD changer unit.
1. Remove four screws
B
from the rear panel. Fig.3)
2. Pull the heat sink cover outward.
3. Remove four screws
AA
from the rear panel between
the heat sink holder.
4. Remove two screws
X
that retain the speaker terminals
and AUX terminal.
5. Remove screws
YY
that retains the rear panel, and
then remove the rear panel.
6. Disconnect the parallel wires from the connectors
FW951 on the power trans PCB.
7. Remove the clamp of AC power cord from the chassis.
8. Remove four screws
AB
that retain the power trans
PCB and then remove the assembly.
Fig.29
Fig.30
Fig.31
Chassis
AB
Rear panel
Power amp and
supply PCB
AA
YY
X
Clamp
Fuse F953)
T1.25A 250V
Fuse F952)
T3.15A 250V
Fuse F951)
T1.6A 250V

MX-KA6
1-18
Adjustment method
Measurement instruments required
for adjustment
1. Low frequency oscillator.
This oscillator should have a capacity to output
0dB to 600ohm at an oscillation frequency of
50Hz-20kHz.
2. Attenuator impedance : 600ohm
3. Electronic voltmeter
4. Frequency counter
5. Wow flutter meter
6. Test tape
VT712 : For Tape speed and wow flutter 3kHz)
VT703 : For Head angle 10kHz)
7. Blank tape
TAPE I : AC-225 TAPE II : AC-514
8. Torque gauge : For play and back tension forward;
TW2111A, Reverse; TW2121A Fast Forward and
Rewind; TW2231A
9. Test disc: CTS-1000 12cm),GRG-1211 8cm)
10. Jitter meter
Measurement conditions
Power supply voltage
AC 110V / 127V / 220V / 230~240V 50/60Hz)
Measurement
output terminal : Speaker out
: TP101 Measuring for TUNER/
DECK/CD)
: Dummy load 6ohm
Radio input signal
AM modulation frequency : 400Hz
Modulation factor : 30%
FM modulation frequency : 1kHz
Frequency displacement : 22.5kHz
Frequency Range
AM 530kHz~1710kHz 10kHZ)
531kHz~1710kHz 9kHZ)
FM 87.5MHz~108MHz 50HZ/100kHZ)
Standard measurement positions of
volume and switch
Power : Standby Light STANDBY Indicator)
Sound Turbo, A, BASS EX : OFF
Sound mode : OFF
Main VOL. : 0 Minimum
Travers mecha set position : Disc 1
Precautions for measurement
1. Apply 30pF and 33kohm to the IF sweeper output
side and 0.082 F and 100kohm in series to the
sweeper input side.
2. The IF sweeper output level should be made as
low as possible within the adjustable range.
3. Since the IF sweeper is a fixed device, there is no
need to adjust this sweeper.
4. Since a ceramic oscillator is used, there is no need
to perform any MPX adjustment.
5. Since a fixed coil is used, there is no need to adjust
the FM tracking.
6. The input and output earth systems are separated.
In case of simultaneously measuring the voltage in
both of the input and output systems with an
electronic voltmeter for two channels, therefore, the
earth should be connected particularly.
7. In the case of BTL connection amplifier, the minus
terminal of speaker is not for earthing. Therefore,
be sure not to connect any other earth terminal to
this terminal. This system is of an OTL system.

MX-KA6
1-19
Items Measurement
conditions Measurement method Standard
values
Adjusting
positions
Cassette deck mechanism
Front side)
Head azimuth screw
Forward side)
PB Head
Deck-A)
REC/PB Head
Deck-B)
Head azimuth screw
Reverse side)
Head azimuth screw
Reverse side)
Head azimuth screw
Forward side)
1. Playback the test tape VT703 10KHz) or equivalent.
2. Adjust the head azimuth screw to obtain maximum
output and both output of L / R is in 3dB.
3. Put on the screw lock paint after alignments.
1. Insert the recording tape in deck-B.
2. Starting the recording.
3. Adjust the oscillation frequency to 80KHz+/-3KHz by
core of Oscillation coil of L301.
Test tape
: VT703 10kHz)
Measurement output
terminal
: Left and Right
speaker output
6-ohm loaded)
or
Headphone Output
32-ohm loaded)
Test tape
: TYPE I AC-514
Measurement output
terminal
: Erase head terminal
CN308 8-Pin)
Maximum output
80kHz+/-3kHz
Adjust the
head azimuth
screw only
when the head
has been
changed.
Use the High-
Impedance
Probe or
Frequency
counter input.
Cassette Head
Azimuth Alignments
Recording Bias
Frequency Alignment
Items Measurement
conditions Measurement method Standard
values
Adjusting
positions
1. Set the Signal Generator signal to 530KHz the feed
to Loop Antenna.
2. Receiving the signal and the adjust the OSC coil L2)
obtain the V.T is 1.40V +/-0.05V.
3. Change the receiving frequency to 600KHz 603KHz).
4. Adjust the Antenna coil L2 ) obtain maximum
sensitivity. Adjust the SSG output to out of AGC range.)
1. Set the receiving frequency to 530KHz.
2. Feed the 450KHz signal to AM antenna input.
3.Adjust the IFT Block T1 obtain to maximum output.
Adjust the SSG output to out of AGC range.)
Input signal
: 530kHz
600kHz
Adjustment point
: Antenna coil L2)
Input signal
: 530kHz
Adjustment point
: IFT T1)
V. T
: 1.40V+/-0.05V
Maximum
sensitivity
Maximum output
Adjust the OSC
coil only when
the AM coil block
has been changed.
Adjust the IFT
only when the
IFT block has
been changed.
AM Tracking
Alignments
AM IFT Alignments
Note: The adjustment of CD section is not required.
Tape recorder section
Tuner section
Arrangement of adjusting positions

MX-KA6
1-20
Flow of functional operation until TOC read
Slider turns REST
SW ON.
Automatic tuning
of TE offset
Laser ON
Detection of disc
Automatic measurement of
Focus S-curve amplitude
Automatic tuning of
Focus offset
Disc is rotated
Focus servo ON
Tracking servo ON)
Automatic tuning of
Tracking error balance
Automatic measurement of
Tracking error amplitude
Automatic tuning of
Focus error balance
Disc to be
braked to stop
Tracking
servo
on states
Tracking
servo
off states
Disc states
to rotate TOC reading
finishes
Automatic measurement
of TE amplitude and
automatic tuning of
TE balance
500mv/div
2ms/div Fig-1
Approx.3sec
pin 20 of
IC611 TE)
Approx
0.3V
VREF
Tracking error waveform at TOC reading
Power ON Play Key
Confirm that the Focus error
S-cuve signal at the pin32 of
IC601 is approx.2Vp-p
Confirm that the signal from
pin24 IC601 is 0V as a
accelerated pulse during
approx.400ms.
Confirm the waveform of
the Tracking error signal.
at the pin 20 of IC611 R643)
See fig-1)
Automatic tuning of
Focus error gain
Automatic tuning of
Tracking error gain
TOC reading
Play a disc
Confirm the eys-pattern
at the lead of Pin 5 of IC 611
Confirm that the voltage at the pin5
of CN602 is "H"\"L"\"H".
Check Point
Check that the voltage at the
pin40 of IC601 is + 5V?
Other manuals for MX-KA6 Series
2
This manual suits for next models
2
Table of contents
Other JVC Stereo System manuals

JVC
JVC FS-SD58V User manual

JVC
JVC MX-KC4 User manual

JVC
JVC UXG28 - UX G28 Micro System User manual

JVC
JVC MX-KB22 User manual

JVC
JVC Micro Component System UX-G200 User manual

JVC
JVC Micro Component System UX-M55 User manual

JVC
JVC CA-UXF3B User manual

JVC
JVC MX-KC2 Administrator Guide

JVC
JVC UX-D99R EN User manual

JVC
JVC UX-GP5 User manual