20 English
The voltage indicated on the type plate
must correspond to the voltage of the elec-
trical source.
The minimum fuse rating required at the sock-
et outlet is (see technical specifications).
The maximum tolerable mains impedance
at the electrical contact point (see Techni-
cal Data) must not be exceeded.
The appliance should always be connected
to the electrical mains using a plug. It is for-
bidden to permanently connect the appli-
ance to the power supply. The plug is only
for mains separation.
Check the power cord with mains plug for
damage before every use. If the power cord
is damaged, please arrange immediately
for the exchange by an authorized custom-
er service or a skilled electrician.
The plug and coupling of the extension ca-
ble used must be watertight.
Use the extension cord that has an ade-
quate cross-section (see "Technical Data")
and unwind it fully from the cable drum.
Unsuitable extension cables can be haz-
ardous. Only use extension cables out-
doors which have been approved for this
purpose and labelled with a sufficient cable
cross section:
For connection values, see type plate/tech-
nical data.
몇Warning
Observe regulations of water supplier.
According to the applicable regulations, the
appliance must never be used on the drinking
water net without a system separator. Use a
suitable system separator manufactured by
Kärcher; or, as an alternative, a system sepa-
rator as per EN 12729 Type BA.
For connection values refer to technical
specifications
Î
Connect the supply hose(minimu length
7.5 m, minimum diameter 3/4“) to the wa-
ter connection point of the machine and at
the water supply point (for e.g. a tap).
Note
The supply hose is not included.
ÎOpen the water supply.
ÎScrew the suction hose with filter (order
no. 4.440-238.0) to the water connec-
tion.
ÎDeaerate the appliance:
Unscrew the nozzle.
Switch on the appliance and let it run
until the water exiting is bubble-free.
At the end let the appliance run for ap-
prox. 10 seconds - then switch off. Re-
peat the procedure for a couple of
times.
ÎSwitch off the appliance and fit the noz-
zle again.
Danger
If the appliance is used in hazardous areas
(e.g. filling stations) the corresponding
safety provisions must be observed.
몇Warning
Clean engines only at places with corre-
sponding oil separators (environmental
safety).
Wash animals only with a flat low pressure
jet (see "Select spray type").
Risk of blocking. Place the nozzles in the
accessory compartment with their joint
pointing upward.
Note
The appliance is equipped with a pressure
switch. The motor starts up only when the
lever of the pistol is pulled.
ÎRoll off the high pressure hose totally
from the hose drum.
ÎSet the appliance switch to "I".
ÎUnlock the hand-spray gun and pull the
lever of the gun.
ÎSet working pressure and flow rate
through turning (rungless) at the pres-
sure- and amount regulation (B) (+/-).
Water connection
Connection to the water supply
Drawing in water from open reservoirs
Operations
High pressure operation