Powador
Grounding Kit
XP Series
Installation Instructions
XP Series Powador Grounding Kit_EN Page 3
Powador Grounding Kit
XP Series
Installation
Page 4 XP Series Powador Grounding Kit_EN
XP Series Powador Grounding Kit
Installing the XP Series Powador Grounding Kit
1. Remove all connected cables from the ground fault monitor.
2. Take out the circuit board and the ground fault monitor.
XP Series Powador Grounding Kit_EN Page 5
XP Series Powador Grounding Kit
4. Remove the cable from the cable duct (wires P4P-PCB2 and P4N-PCB2).
3. Remove the cables connected to connector CN5 on the DSI circuit board (wire P4P-PCB2, P4N-PCB2).
Page 6 XP Series Powador Grounding Kit_EN
XP Series Powador Grounding Kit
5. Remove the PE cable.
6. For negative grounding (-) of the PV generator, remove wire MP1002.
* For positive grounding (+) of the PV generator, remove wire MN1002.
XP Series Powador Grounding Kit_EN Page 7
XP Series Powador Grounding Kit
7. For negative grounding of the PV generator, remove wire MP1002 from the fuse at the
DC+ input.
For positive grounding of the PV generator, remove wire MN1002 from the fuse at the
DC- input.
8. Use the blade receptacles as shown (wires K4B1-TD10 and K4C1-TD10).
* The blade receptacles are needed to connect the leads to the fuse holder.
Page 8 XP Series Powador Grounding Kit_EN
XP Series Powador Grounding Kit
9. Mount the XP series Powador grounding kit in the inverter.
Wire No. PE
PE Cable
10. Ensure the correct installation direction of the grounding fuse.
The stud has to face towards the switch.
In the case of reverse installation the inverter will not be notified if the fuse blows.
XP Series Powador Grounding Kit_EN Page 9
XP Series Powador Grounding Kit
12.
Open the fuse holder and connect wire MN1002 to the fuse holder in order for negative
grounding (-) of the PV generator.
For positive grounding (+) of the PV generator, wire MP1002 must be connected.
11. Connect wire K4B1-TD10 to point 1 of the fuse holder, and wire K4C1-TD10 to point 2
(see the following figure).
Wire No. K4C1-TD10
Wire K4B1-TD10 Wire K4C1-TD10
Page 10 XP Series Powador Grounding Kit_EN
XP Series Powador Grounding Kit
14. Close all covers.
13. Connect the PE cable on the grounding screw.
31000884-02-101125
Carl-Zeiss-Straße 1 · 74172 Neckarsulm · Germany · Tel +49 7132 3818-0 · Fax +49 7132 3818-703 · info@kaco-newenergy.de · www.kaco-newenergy.de
The text and figures reflect the current technical state at the time of printing. Subject to technical changes. Errors and omissions excepted.


Popular Control Unit manuals by other brands

AUTEC Air series manual

AUTEC

AUTEC Air series manual

Omron SYSMAC C200H-ASC02 Operation manual

Omron

Omron SYSMAC C200H-ASC02 Operation manual

Omron SC20G2 Operation manual

Omron

Omron SC20G2 Operation manual

Pilz PIT js2 operating manual

Pilz

Pilz PIT js2 operating manual

Alinx AC7Z100B user manual

Alinx

Alinx AC7Z100B user manual

Festo ERMB operating instructions

Festo

Festo ERMB operating instructions

Pfister OX8 Quick installation guide

Pfister

Pfister OX8 Quick installation guide

Lutron Electronics QS Timeclock Installation and operation guide

Lutron Electronics

Lutron Electronics QS Timeclock Installation and operation guide

Mitsubishi Electric EHPT Series Operation manual

Mitsubishi Electric

Mitsubishi Electric EHPT Series Operation manual

Reverso FPS-80 instructions

Reverso

Reverso FPS-80 instructions

Vimar by-me Eikon 20545 manual

Vimar

Vimar by-me Eikon 20545 manual

Pulsar MSRD 1024 manual

Pulsar

Pulsar MSRD 1024 manual

Hubbell wiSTAR WIS-IDM installation guide

Hubbell

Hubbell wiSTAR WIS-IDM installation guide

Honeywell Notifier NZM-100-6 Installation and maintenance instructions

Honeywell

Honeywell Notifier NZM-100-6 Installation and maintenance instructions

Allen-Bradley MicroLogix 1762-IQ8 installation instructions

Allen-Bradley

Allen-Bradley MicroLogix 1762-IQ8 installation instructions

Bitzer CM-SW-01 Translation of the original instructions

Bitzer

Bitzer CM-SW-01 Translation of the original instructions

Fermax CITYLINE 4+n installation manual

Fermax

Fermax CITYLINE 4+n installation manual

Danfoss ASV-PV instructions

Danfoss

Danfoss ASV-PV instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.