Introduction
Thank you for purchasing the KATHREIN Digital Systems GmbH glass breaking sensor.
Please take the time to read the following safety and installation information carefully
and attentively before using the glass breaking sensor. It is imperative to comply with
these instructions in order to ensure the safe operation of the device. If you have any
further questions, please contact your local retailer or KATHREIN Digital Systems
GmbH directly. Your glass breaking sensor FGM 100 was developed and built with
state-of-the-art technology and complies with European and German standards.
Please keep this manual safe to be able to answer possible questions in the future.
The manual is an integral part of the product even in case it is resold to a third party.
Disclaimer
All technical details and descriptions in this manual were compiled with the greatest
care. However, KATHREIN Digital Systems GmbH cannot entirely exclude mistakes in
this manual. Therefore, we do not assume any legal responsibility or liability resulting
from wrong information in this manual. Descriptions, technical illustrations and
technical data are subject to change without notice according to technical progress.
In addition, KATHREIN Digital Systems GmbH reserves the right to change the product
and the manual without prior notice. We do not assume any guarantee with regard to
the content of this document. We appreciate any comments on mistakes or
inaccuracies which may help us to improve this product and this manual.
This symbol is intended to attract the user’s attention to the potential
risk of dangerous unprotected voltage inside the housing. This may
lead to electric shock.
This symbol is intended to attract the user‘s attention to user and
maintenance instructions in the manual and documents enclosed
with the product.

3
WARNING:
TO MINIMISE THE RISK OF ELECTRIC SHOCK, YOU MUST NOT EXPOSE THIS PRODUCT
TO WET AND MOIST CONDITIONS AT ANY TIME.
All KATHREIN Digital Systems GmbH products are lead-free and meet
the requirements stated under the European Directive on the
Restriction of Hazardous Substances (RoHS). This guarantees that
the entire production process and the product itself are free of lead
and of all listed hazardous substances.
This product was tested and complies with the regularities for a class
of digital devices stated under FCC part 15. These limits were
specified to provide reasonable protection against harmful exposure
when operating
the device in a commercial environment. This
product generates, uses and
may emit radio energy. It may in
addition interfere with other radio communication systems if not
installed or used according to this manual.
Using the device in
residential areas may cause disturbances to be possibly remedied at
the user’s expense.
Hereby KATHREIN Digital Systems GmbH declares that the glass
breaking sensor FGM 100 (order number 2220000017
, EAN
4021121548567) is in
conformity with the relevant provisions of
Directive 1999/5/EG.
Conformity:
The declaration of conformity is available at http://www.kathrein-ds.com in
the download section of the respective product. Alternatively, you can
request the declaration of conformity directly from us:
KATHREIN Digital Systems GmbH
Anton-Kathrein-Str. 1–3
83022 Rosenheim, Germany

4
Important Safety Information
WARNING
The warranty claim will expire in case of damages resulting from the
non-observance of this manual.
We do not assume any liability for consequential damages.
We do not assume any liability for damages to persons and/or
material whatsoever which result from improper handling or
noncompliance with the safety instructions. The warranty claim
will expire in such cases!
The glass breaking sensor FGM 100 is equipped with a high-quality housing. However,
please observe the following safety instructions:
•Operate the glass breaking sensor only with the provided batteries.
•Handle the glass breaking sensor with care, heavy vibration or bumps may
damage the device.
•Do not expose the glass breaking sensor to direct sunlight or strong heat,
e.g. heaters.
•Do not install the glass breaking sensor close to strong electric power lines
or magnetic fields, as this may impair the transmission quality significantly.
•Do not install the glass breaking sensor directly on iron or aluminium
surfaces, as this may impair the wireless transmission significantly. Use a
non-conducting material to insulate the device from the installation
surface.
•Do not install the glass breaking sensor in moist, very cold or very hot
environments.
•Persons (including children) with limited physical, sensory or mental
abilities and/or lacking experience and/or knowledge must not use this
product.
•Keep children away from the product and other connected electrical
appliances at all times. The glass breaking sensor includes small parts
they can swallow. Lay cables expertly so that they are neither bent nor
otherwise damaged. Install the glass breaking sensor out of children’s
reach. Do not leave packaging materials unattended, as they may be
dangerous for playing children.
•Use a damp cloth to clean the glass breaking sensor’s surface, then dry it.
Cleaning agents will damage the surface.

5
Malfunctions and Defects
If you notice any kind of defect, remove the batteries from the glass breaking sensor
FGM 100 and contact your retailer or KATHREIN Digital Systems GmbH directly. Any
further usage of the system may lead to fire or electric shock!
Intended Use
The KATHREIN Digital Systems GmbH glass breaking sensor is designed for building
security. Use the glass breaking sensor FGM 100 indoors only (there is no protection
class for the glass breaking sensor). Any other use than that described in this manual
is not permitted and will void any warranty or guarantee as well as liability claims. The
same applies if the device is modified or retrofitted.
Disposal
Do not dispose of the device with domestic waste!
This product complies with the EU Directive on waste electrical and
electronic equipment (WEEE) and therefore must not be disposed of
with domestic waste. Dispose of the device via your local collection
point for waste electronic equipment!
This product contains software programs subject to the GPL free software license.
This product contains software that was developed by third parties and/or software
subject to the GNU General Public License (GPL) and/or the GNU Lesser General
Public License (LGPL). We will send you the source code of these programs on request.
The GPL and/or LGPL code used and offered in this product is EXCLUSIVE OF ANY
GUARANTEE WHATSOEVER and is subject to the copyright of one or several authors.
For further details, please refer to the GPL and/or LGPL code of this product and to
the terms of use of GPL and LGPL.
You can read the complete license text at http://www.gnu.org/licenses/gpl-2.0.html.
For an unofficial German translation, please go to
http://www.gnu.de/documents/gpl.de.html.

6
Glass Breaking Sensor FGM 100
Product description:
The glass breaking sensor detects the sound of breaking window glass and notifies
the alarm panel. In order to avoid false alarms, two inputs are required to trigger an
alarm: First, the sensor registers the breaking of glass and, then, the pieces of glass
falling to the ground.
Sensor data:
Dimension (without mount): 10.8 x 8 x 4.3 cm (4.23 x 3.14 x 1.69 in)
Weight: 140 g (0.3 lbs)
Place of installation: Only indoors (opposite of the secured window)
Operating temperatures: -10 °C to +55 °C (14 °F to 131 °F)
Humidity: Maximum 85% (non-condensing)
Radio frequency: 868.63 MHz
1. LED green (internally)
2. LED red (internally)
3. Microphone
4. Dip switch
5. Battery compartment
6. Learn button
7. Tamper contact
8. Mounting holes
LED green:
•In case of a detection of broken glass in the test mode, the LED will be
activated
LED red:
•The red LED lights up if
othe tamper contact is opened or closed
othe Learn button is pressed
oa broken glass is detected in the test mode
Battery:
The glass breaking sensor requires a 3 V CR123A lithium battery. The average battery
life is approx. three years. The alarm panel will inform you when the battery is running
low.

7
Connecting the glass breaking sensor and putting it into operation
1. Open the housing by loosening the screw at the bottom.
2. Insert the supplied battery.
3. Open the configuration menu of the alarm panel and then the menu
“Sensors” “Add” and press “Start”.
4. Press the Learn button of the glass breaking sensor once.
5. The sensor is listed in the lower menu after a short time and you hear a brief
signal tone from the alarm panel.
6. Press “Add” to complete the connection process.
7. Close the housing and fasten the screw.
Range test:
To test the signal strength at the desired installation location, perform a range test.
1. Open the alarm panel menu “Sensors” “Range” and press “Start”.
2. Press the Learn button of the glass breaking sensor.
3. The sensor and the signal strength should be indicated. The higher the
indicated number the better the reception (1 – 9).
4. Click “Stop” to end the test.
Please note:
If there is no signal at the installation location or the signal strength is below 4 or
frequently falls below this level (signal fluctuations of 2 to 3 are normal), we
recommend using a repeater to improve the signal.
Dip switch:
The sensitivity of the glass breaking sensor can be adjusted by the two Dip switches:
Sensitivity Dip switch 1 Dip switch 2 Reach
Maximum
OFF
OFF
8 m
Medium OFF ON 5 m
Low
ON
OFF
3 m
Minimum ON ON 1.5 m
Test mode:
Press the Learn button to activate the test mode of the FGM 100 for five minutes. If
glass breakage is detected during this time, the red and the green LED will light up.
This allows you to test the function of the glass breaking sensor without triggering an
alarm at the control panel.

8
Notes:
•The glass breaking sensor can be installed both on a wall or on the ceiling
using the supplied screws.
•The sensor will only trigger an alarm if it first registers a blow to the glass
pane and then the breakage of glass.
•The glass breaking detector detects sounds in a 360° radius.
•Make sure that no obstacles are between the window and the glass
breaking sensor.
•Install the glass breaking sensor in an open space (not in corners), so that
that sound waves can reach the sensor from as many sides as possible.
•Do not install the glass breaking sensor directly next to electronic devices
e.g. speakers, air conditioners or devices causing noise.