manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LST
  6. •
  7. Home Safety Product
  8. •
  9. LST MGE8-1 User manual

LST MGE8-1 User manual

Other LST Home Safety Product manuals

LST M201E-240-DIN User manual

LST

LST M201E-240-DIN User manual

LST IBSOU-DD-P01 User manual

LST

LST IBSOU-DD-P01 User manual

LST M503ME User manual

LST

LST M503ME User manual

LST HFM/3/22/02 User manual

LST

LST HFM/3/22/02 User manual

LST HFM/153-27D User manual

LST

LST HFM/153-27D User manual

LST IBSST-DR-P01 User manual

LST

LST IBSST-DR-P01 User manual

LST M510E-4-20 User manual

LST

LST M510E-4-20 User manual

LST M210E User manual

LST

LST M210E User manual

LST M220E User manual

LST

LST M220E User manual

LST M221E User manual

LST

LST M221E User manual

LST M400DKMB-AS User manual

LST

LST M400DKMB-AS User manual

Popular Home Safety Product manuals by other brands

Innohome SGK4010 manual

Innohome

Innohome SGK4010 manual

Safety 1st 48390 user guide

Safety 1st

Safety 1st 48390 user guide

Little Partners LPA1002 manual

Little Partners

Little Partners LPA1002 manual

Cooper Lighting Sure-Lites CU1 specification

Cooper Lighting

Cooper Lighting Sure-Lites CU1 specification

EUCHNER MGB-L0HE-ARA-R-110691 operating instructions

EUCHNER

EUCHNER MGB-L0HE-ARA-R-110691 operating instructions

Steren ALA-2010 user manual

Steren

Steren ALA-2010 user manual

HeathCo All MetAl Motion SenSor HD-9260 owner's manual

HeathCo

HeathCo All MetAl Motion SenSor HD-9260 owner's manual

FireAngel WFS-627 user manual

FireAngel

FireAngel WFS-627 user manual

Abus JC4400 LENNY quick start guide

Abus

Abus JC4400 LENNY quick start guide

Heath Zenith SL-5710 manual

Heath Zenith

Heath Zenith SL-5710 manual

Safety Link Froglink anchor Installation handbook

Safety Link

Safety Link Froglink anchor Installation handbook

Samsung SSA-R2001 user manual

Samsung

Samsung SSA-R2001 user manual

Philips LRM 8112 Specification sheet

Philips

Philips LRM 8112 Specification sheet

IMS 17 operating instructions

IMS

IMS 17 operating instructions

First Alert Fire Escape Ladder EL52W-2 user manual

First Alert

First Alert Fire Escape Ladder EL52W-2 user manual

Datexx SENTINA LED-92M owner's manual

Datexx

Datexx SENTINA LED-92M owner's manual

Lights of America Motion Sensor Light Control 9700LeD owner's manual

Lights of America

Lights of America Motion Sensor Light Control 9700LeD owner's manual

SECO-LARM Emergency & Push-To-Exit N.O./N.C. Button... Specifications

SECO-LARM

SECO-LARM Emergency & Push-To-Exit N.O./N.C. Button... Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
MGE8-1_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.
Detector Zone Extension
MGE8-1
Description
With the Detector Zone Extension MGE8-1 the fi re de-
tection control panel Series BC016 can be extended
from 8 to 16 addressable detector zones. Up to 64
detectors (addresses) per detector line can be indivi-
dually identifi ed with the aid of an address module. In
the event of an alarm, the fi re detection control panel
indicates the number of the detector that triggers the
alarm fi rst.
Depending on the type of detector (manual call point,
automatic fi re detector with or without alarm verifi cati-
on, fault message contacts as well as contacts for tech-
nical messages), the function of the detector zone can
be set separately for each detector line. Each input of
the Detector Zone Extension is protected against over-
voltage and thus provides high system stability.
• Extends fi re detection control panels
Series BC016 to 16 detector lines in
addressable conventional technology
• Individual detector addressing with
optional address module
• Individual setting of detector zone
function
• Lines monitored for wire breakage,
short circuit, and short to earth
Specifi cations
Current consumption at 24V typ. 32mA (8 zones terminated, without detectors)
Line voltage typ. 20.0V
Line current typ. 3.8mA
End-of-line resistance 5.6kΩ or 3,3kΩ (depending on setup)
Line resistance max. 50Ω per core
Ambient temperature -5°C to +50°C
Dimensions L × W × H 100 × 65 × 15 (mm)
Weight 80g
Part No. 210110
Order name Detector Zone Extension MGE8-1