KAZE APPLIANCES SNP100 User manual

VENTILATION FAN
WARNING
Models: SNP100 SNP100L9
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
CAUTION
CLEANING & MAINTENANCE
OPERATION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) -
protected branch circuit (ceiling installation only).
8. This unit must be grounded.
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS
PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the
motor with the exact service motor. The impeller should also be replaced.
See “CONNECT ELECTRICAL WIRING” for details.
Cod: 0060300000-A

PLAN THE INSTALLATION
TYPES OF TYPICAL INSTALLATIONS
1. Do not use in a cooking area.
2. Two ways to connect ductwork to a factory-shipped unit.
ASSEMBLY INSTRUCTIONS
1. Housing mounted to I-joists (Start at “ASSEMBLY INSTRUCTIONS 1”)
2. Housing mounted to joists (Start at “ASSEMBLY INSTRUCTIONS 1” )
3. Housing mounted to truss (Start at step “ASSEMBLY INSTRUCTIONS 2”)
1. MOUNT HOUSING TO JOIST OR I-JOIST.
ROOF CAP*
(with built-in
damper)
ROUND
DUCT* WALL CAP*
(with built-in
damper)
*Purchase
separately
POWER
CABLE*
INSULATION*
(Place around and
over Fan Housing.)
Seal gaps
around
Housing.
FAN
HOUSING
ROUND
ELBOW(S) *
Seal duct
joints with
tape.
Keep duct
runs short
2. Mount with mountion holes and hanger bar
a. Hold the housing so that it is in contact with the bottom of the joist.
b. Attach the housing with four (4) screws to the joist through the holes in each
mounting flange.
a. Slide one hanger bar into the channel on the housing and adjust as needed to fit
between framing.
b. Hold housing in place so that the housing contact the bottom of the joist, Screw
housing to joist through the hole of the housing .
c. Screw the hanger bar onto the other side of joist through the hole.
d. Screw hanger bar to housing with screw.
e. Refer to the right diagram.
3. Mount to I-joist
a. Slide one hanger bar into channel on the housing and adjust as needed.
b. Hold housing in place so that the housing contacts the bottom of the joist.
c. Screw housing to joist through the hole of the housing.
d. Screw the hanger bar onto the joist through the hole.
e. Screw hanger bar to housing with screw .
2

ASSEMBLY INSTRUCTIONS
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
CONNECT ELECTRICAL WIRING
5. INSTALL ROUND DUCTWORK
a. Connect the round ductwork (not included) to the damper/duct connector, and run the
ductwork to a roof or wall cap (not included).
b. Using tape (not included), secure all the ductwork connections so that they are air tight.
c. Insulated flexible duct is recommended for the quietest possible installation. If rigid
duct is used, a short (1-3 feet) section of insulated flexible duct will ensure quiet
operation.
The ducting from this fan to the outside of building has a strong effect on the air flow,
noise and energy use of the fan. Use the shortest, straightest duct routing possible for
best performance, and avoid installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans
installed with existing ducts may not achieve their rated air flow.
4. Install DUCT AND BLOWER ASSEMBLY
Hole Hole
Hole
a.Install duct from the inside of the housing;Fix the duct by the tab.
b.Fix the BLOWER ASSEMBLY to the housing by 3 screws.
RETROFIT INSTALLATION
1. Remove wire panel and blower assembly before installation.
2. Fold mounting ears flat against housing. Blower
assembly
Wire
panel
3. Enlarge ceiling opening to 9-1/2” by 9-1/2”, leave ductwork and wiring in place.
4. Connect wiring according to the wiring diagram.Re-install wire panel.
5. Mounting fan
a. Mount with additional mounting holes
The interior of the fan housing contains additional mounting holes in case
exterior mounting is not possible.
Screw or nail the fan housing directly to the framing or joists.
Remove the blower assembly as directed in the service parts section of this
manual to gain access to the additional mounting holes.
b. Mount with hole of the flange
Use screws (included) to screw fans to the ceiling through the holes of the
housing.
6. Connect duct
Pull existing ducting through housing discharge opening and tape ducting to
duct connector. Push connector/ducting back through opening,fix the duct by
the tab.
7. Install the blower assembly.
additional mounting holes
Hole
Hole
Hole
Tab
9-1/2”
9-1/2”
UNIT
BLACK (BLK)
SWITCH BOX
FAN
POWER SUPPLY
120V AC
GROUND (GRD)
WHITE (WHT)
WIRING
PLATE
FAN
RECEPTACLE
FAN
UNIT
SWITCH BOX
LINE
IN
ON/OFF
SWITCH
BLK
BLK
WHT
WHT
GRDGRD
SNP100
3

WARRANTY
INSTALL GRILLE
SERVICE PARTS
CONNECT ELECTRICAL WIRING
Install ceiling material to complete the ceiling construction and cut around the fan housing.
To attach the grille assembly to the fan housing, Insert the light plug from the grille assembly into the
wire panel (for SNP100L9).
To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille
assembly and position the grille into the housing with the grille springs in the appropriate slots. Push
the grille assembly towards the ceiling to secure.
This warranty covers all defects in workmanship or materials for:
The mechanical and electrical parts contained in this product, for a period of 12 months, from the date of purchase. You must keep and be able to
provide your original sales receipt as proof of the date of purchase. This warranty is covered the original retail purchaser of this product. The manufac-
turer will repair or replace, in your home, any mechanical or electrical part which proves defective in normal household use for a period of 12 months.
THIS WARRANTY DOES NOT COVER:
• Damages from improper installation
• Damages from shipping
• Damages from misuse, abuse, accident, alteration, lack of proper care and maintenance
• Damages from service by persons other than an authorized dealer or service center.
• Labor, service, transportation and shipping charges for the removal of defective parts and for installation of a replacement part, beyond the initial
12-month period.
This warranty does not extend to fluorescent lamp starters and tubes.
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies. This warranty does not cover incidental or consequential
damages. Some states do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to you. Some states do not
allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. This warranty gives you specific legal rights, and you
may also have other rights, which vary from state to state.
1b
1a
2
3
4
5
c
a
b
7
6
8
10
11
9
d
d
Grille Assembly (includes part 2)
* Blower Assembly includes part 3, 4, 5, 6, a, b
Replacement installation: Remove the screw (part a), then take out the blower
assembly from the housing (part 7). Replace the broken parts.
WARNING: Ensure that the fan is switched off from the supply mains before replacing.
PART PART NAME Qty.
1a
Grille Assembly (includes part 2)
1b
2
3
4
5
6
7
8
9
10
Housing
Blower Wheel
Blower
Wire Panel / Harness Assembly
Motor
1For SNP100
For SNP100L9 1
2
1
1
1
1
1
1
Wiring Plate
4
11 Damper/Duct Connector
1
1
Motor Plate
Grille Spring
Hanger Bars
a3Screw
b3Screw
c4Screw
d2Screw
UNIT
BLACK (BLK)
LIGHT
SWITCH BOX
FAN
120V AC LINE IN
GROUND (GRD)
WHITE (WHT) BLUE (BLU)
FAN
RECEPTACLE
LIGHT
RECEPTACLE
WIRE
PANEL
LIGHT
FAN
UNIT
SWITCH BOX
LINE
IN
FAN
SWITCH
LIGHT
SWITCH
BLK
BLU
BLK WHT
WHT
WHT
GRD
SNP100L9
4
This manual suits for next models
1
Table of contents
Other KAZE APPLIANCES Fan manuals

KAZE APPLIANCES
KAZE APPLIANCES SEPD200L2 User manual

KAZE APPLIANCES
KAZE APPLIANCES SE90TL2 User manual

KAZE APPLIANCES
KAZE APPLIANCES SEP120H User manual

KAZE APPLIANCES
KAZE APPLIANCES SNP100H User manual

KAZE APPLIANCES
KAZE APPLIANCES SNP100HL9 User manual

KAZE APPLIANCES
KAZE APPLIANCES SEP120 User manual

KAZE APPLIANCES
KAZE APPLIANCES SE90THL2 User manual

KAZE APPLIANCES
KAZE APPLIANCES SE90PL2 Instruction Manual

KAZE APPLIANCES
KAZE APPLIANCES SE90P User manual

KAZE APPLIANCES
KAZE APPLIANCES SE90T User manual