Kelly KLS4812S User manual

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
Kelly KLS-S Brushless Motor
Controller User’s Manual
Devices Supported:
Rev1.10
Feb.2019
KLS4812S KLS7212S
KLS6018S KLS7230S
KLS6030S KLS7218S
KLS6035S

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
1
Contents
Chapter 1 Introduction..............................................................................................2
1.1 Overview.............................................................................................................................. 2
Chapter 2 Features and Specifications................................................................. 3
2.1 General functions............................................................................................................... 3
2.2 Features............................................................................................................................... 4
2.3 Specifications...................................................................................................................... 5
2.4 Name Regulation................................................................................................................5
Chapter 3 Wiring and Installation........................................................................... 6
3.1 Mounting the Controller..................................................................................................... 6
3.2 Connections...................................................................................................................... 10
3.3 Installation Check List......................................................................................................14
Chapter 4 Programmable Parameters................................................................ 15
4.1 Step 1................................................................................................................................. 16
4.2 Step 2................................................................................................................................. 20
4.3 Step 3................................................................................................................................. 21
4.4 How to use Identification angle operation function..................................................... 22
Chapter 5 Maintenance..........................................................................................27
5.1 Cleaning.............................................................................................................................27
5.2 Configuration.....................................................................................................................27
Table 1: LED CODES................................................................................................ 28
Contact Us:..................................................................................................................30

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
2
Chapter 1 Introduction
1.1 Overview
This manual introduces the Kelly Small sinusoidal wave brushless BLDC motor controllers’
features, their installation and their maintenance. Read the manual carefully and thoroughly
before using the controller. If you have any questions, please contact the support center of Kelly
Controls.
Kelly’s programmable motor controllers provide efficient, smooth and quiet controls for
electric motorcycles, golf carts and go-carts, as well as industrial motor control. It is mainly
supposed to solve noise problems of BLDC motor driving application. The KLS-S motor
controller must be based on hall sensors type.KLS-S controller can not support sensorless
brushess motor for now.Compared to the traditional trapezoidal waveform control technology,
this technique based on sinusoidal wave driving technology to reduce the operation noise and
1/3 switching loss, which well meets the noise reduction and efficiency requirements in the
application of DC brushless motor. It uses high power MOSFET’s and, SVPWM and FOC to
achieve efficiencies of up to 99% in most cases. A powerful microprocessor brings in
comprehensive and precise control to the controllers. It also allows users to adjust parameters,
conduct tests, and obtain diagnostic information quickly and easily.People can program the KLS
controller on PC software and Android App.There is one more choice for customers to program
KLS controller now.The APP software is based on Tablet with Android OS.Customers may add a
Z-TEK USB to RS232 cable for programming KLS controller if they want to use Android Tablet.
Both PC software and Android APP can provide one screen to monitor the controller
parameters.Sometimes people can use a small Android Tablet as display device.
Anyway please try to do identification angle operation before running the motor.
And please don't try to connect the controller to user program while the motor is still running,let
alone change the setting in user program or Android App.That is to say,if you want to connect
controller to user program or try to do programming,please stop the motor first.
This is the most important thing.

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
3
Chapter 2 Features and Specifications
2.1 General functions
(1) Extended fault detection and protection. The LED flashing pattern indicates the fault
sources.Customers can read the error message in PC software or Android APP also.
(2) Monitoring battery voltage. It will stop driving if the battery voltage is too high and it will
progressively cut back motor drive power as battery voltage drops until it cuts out
altogether at the preset “Low Battery Voltage” setting.
(3) Built-in current loop and over current protection.
(4) Configurable motor temperature protection range.
(5) Current cutback at low temperature and high temperature to protect battery and controller.
The current begins to ramp down at 90℃case temperature, shutting down at 100℃.
(6) The controller keeps monitoring battery recharging voltage during regen braking.
(7) Maximum reverse speed and forward speed can be configured between 20% and 100%
respectively and separately.
(8) A 4pin connector to RS232 port and a Z-TEK USB to RS232 cable allows for configuration,
programming and software upgrades using the tablet which must be based on Android OS
now.People can do the same things on PC software by using a standard USB to RS232
cable instead.
(9) Provision of a +5 volt and +12 volt output to supply various kinds of hall sensors.
(10) 5 switch inputs which are activated by connection to 12V. Default to throttle switch, brake
switch,reversing switch,forward switch and Boost switch.
(11) 3 analog 0-5V inputs that default to throttle input,Brake analog input and motor
temperature input
(12) Copy signal of one of hall sensors.
(13) Configurable boost switch. Enables the maximum output power achievable if the switch is
turned on.The effect is the same as full throttle position even if you don’t turn throttle at all.
(14) 12V brake switch input used different port from motor temperature sensor.You can use
both brake switch and motor temperature sensor functions at the same time on the latest
version.Pin 25 is 12V brake switch input port.Pin1 is motor temperature sensor input port.
(15) Optional joystick throttle. A bi-symmetrical 0-5V signal for both forward and reversing.
(16) Configurable motor over-temperature detection and protection with the recommended
thermistor KTY84-130/150 or KTY83-122.
(17) 3 hall position sensor inputs. Open collector, pull up provided.
(18) Brake analog regen mode.This regen mode doesn't need brake switch to support any more
on KLS controller.Only available from software version 0106 or advanced version.
(19) Enhanced regen brake function. A novel ABS technique provides powerful and smooth
regen.The regen can happen at any speeds until zero speed.
(20) Cruise control.Only can be activated in forward direction.
(21) Bluetooth function.Required a small Bluetooth converter which needs to be purchased in
addition from our website.This small converter is only useful for KLS controller.
(22) Can support three speed function on the latest version.

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
4
Caution! The regen is not a safe function.Usually you may use the mechanical brake.
2.2 Features
1) Intelligence with powerful microprocessor.
2) Synchronous rectification, ultra low drop, fast SVPWM and FOC to achieve very high
efficiency.
3) Electronic reversing.
4) Voltage monitoring on 3 motor phases, bus, and power supply.
5) Voltage monitoring on voltage source 12V and 5V.
6) Current sense on all 3 motor phases.
7) Current control loop.
8) Hardware over current protection.
9) Hardware over voltage protection.
10) Configurable limit for motor current and battery current.
11) Low EMC.
12) LED fault code.
13) Battery protection: current cutback, warning and shutdown at configurable high and low
battery voltage.
14) Rugged aluminum housing for maximum heat dissipation and harsh environment.
15) Rugged high current terminals, and rugged aviation connectors for small signal.
16) Thermal protection: current cut back, warning and shutdown on high temperature.
17) Controller can do auto_Identification angle for different degrees of hall sensors.
18) Configurable high pedal protection: the controller will not work if high throttle is detected at
power on.
19) Current multiplication: Take less current from battery, output more current to motor.
20) Easy installation: 3-wire potentiometer will work.
21) Standard PC/Laptop computer to do programming.There is one more choice for customers
to program KLS controller.Standard Tablet with Android OS to do programming.Need a
Z-TEK USB TO RS232 cable for connecting the controller to App program in Tablet or
Android Cell phone.
22) User program provided. Easy to use. No cost to customers.
23) Support motors with any number of poles.
24) Up to 70,000 electric RPM standard. (Electric RPM = mechanical RPM * motor pole
pairs;Motor pole pairs=Motor poles/2).

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
5
2.3 Specifications
•Frequency of Operation: 10KHz or 20KHz.
•Standby Battery Current: < 0.5mA.
•5V or 12V Sensor Supply Current: 40mA.
•Controller supply voltage range: PWR, 18V to 90V for controllers rated equal or lower than
72V.
•Supply Current, PWR, 30mA Typical.
•Configurable battery voltage range, B+. Max operating range: 18V to 1.25*Nominal Voltage.
•Standard Throttle Input: 0-5 Volts(3-wire resistive pot), 1-4 Volts(hall active throttle).
•Throttle Input: 0-5 Volts. Can use 3-wire pot to produce 0-5V signal.
•
•Full Power Operating Temperature Range: 0℃to 70℃(MOSFET temperature).
•Operating Temperature Range: -40℃to 100℃(MOSFET temperature).
•Max Battery Current :Configurable.
2.4 Name Regulation
The name regulation of Kelly BLDC motor controllers:
KLS 72 30S
KLS:Kelly BLDC motor controller based on sinusoidal waveform which is supposed to
work with BLDC motor with three hall sensors.
72:72V batteries
S:Mini case for the controller
Kelly KLS-S Brushless Motor Controller
Model 20 seconds
Current(Amp)
Continuous
Current(Amp)
Voltage(Volt)
KLS4812S 120 50 24-48
KLS7212S 120 50 24-72
KLS6018S 240 100 24-60
KLS6030S 300 120 24-60
KLS6035S 350 150 24-60
KLS7218S 200 80 24-72
KLS7230S 300 120 24-72
1.48V model: range of the battery voltage is 24V-48V.
1.60V model: range of the battery voltage is 24V-60V.
3.72V model: range of the battery voltage is 24V-72V.

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
6
Chapter 3 Wiring and Installation
3.1 Mounting the Controller
The controller can be oriented in any position which should be as clean and dry as possible,
and if necessary, shielded with a cover to protect it from water and contaminants.
To ensure full rated output power, the controller should be fastened to a clean, flat metal
surface with four screws. Applying silicon grease or some other thermal conductive material to
contact surface will enhance thermal performance.
Proper heat sinking and airflow are vital to achieve the full power capability of the controller.
The case outline and mounting holes’ dimensions are shown in Figure 1,2,3,4,5.
Figure 1:KLS4812S KLS7212S mounting holes’ dimensions (dimensions in millimeters)

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
7
Figure 2:KLS6018S mounting holes’ dimensions (dimensions in millimeters)

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
8
Figure 3:KLS7218S mounting holes’ dimensions (dimensions in millimeters)

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
9
Figure 4:KLS6030S KLS6035S KLS7230S mounting holes’ dimensions
(dimensions in millimeters)

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
10
3.2 Connections
3.2.1 Pin definition of KLS-S Controller
Figure 5: waterproof connector
1,The switch signal is valid to 12V on pin11
2,12V capacity is low.This 12V only can be used for LED or switch signals.
3,Boost and Brake analog regeneration mode used the same pin as pin2.
When Boost is disabled in the user program,the pin2 can be used as brake variable regen
mode.When Boost is enabled,the brake analog regen mode is inactivated automatically.Both
Boost and Brake variable regen mode can not be used at the same time.
DJ7091Y-2.3-11 Pin Definition
(14) REV_SW: Reverse switch input. Orange

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
11
(6) RTN: Signal return or power supply return. Black
(12) FWD: Forward switch or High speed switch White
(11) 12V:12V Source Red
(22) ECO: Low speed switch input. Blue
(7) PWR: Controller power supply (input). Pink
(25) 12V brake switch. Yellowish
DJ7091Y-2.3-21 Pin Definition
(15) Micro_SW: Throttle switch input. Gray
(3) Throttle: Throttle analog input, 0-5V. Green
(20) RTN: Signal return. Black
(8) Meter: Copy signal of hall sensors. Dark Gray
(4) 5V: 5V supply output, <40mA. Purple
(2) Brake_AN:Brake variable regen or Boost function. Brown
DJ7061Y-2.3-21 Pin Definition
(21) RTN:Signal return. Black
(1) Temp: Motor temperature sensor input. Raddle.
(5) 5V: 5V supply output,<40mA.Purple
(18) Hall A: Hall phase A. Yellow
(17) Hall B: Hall phase B. Dark Green
(16) Hall C: Hall phase C. Dark Blue
Notes:
1. All RTN pins are internally connected.
2. Meter function is to copy either of hall sensors.
3. Switch to 12V is active. Open switch is inactive.
Caution:
•Do not apply power until you are certain the controller wiring is correct and has been
double checked. Wiring faults will damage the controller.
•Ensure that the B- wiring is securely and properly connected before applying power.
•The preferred connection of the system contactor or circuit breaker is in series with the B+
line.
•All contactors or circuit breakers in the B+ line must have precharge resistors across their
contacts. Lack of even one of these precharge resistors may severely damage the controller
at switch-on.

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
12
3.2.2 Wiring of KLS-S Controller
3.2.2.1 Standard wiring of KLS-S controller
Figure 6: KLS-S controller standard wiring(F-N-R control)
(Battery voltage can be used for controller supply)

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
13
Figure 7: KLS-S controller standard wiring(Three speed function control)
(Battery voltage can be used for controller supply)
3.2.2.2 Optional wiring of KLS-S controller
The 12V input signal of the pin supplies the second braking function of the controller.
Figure 8: Wiring of brake switch(12V): 12V is provided by external source.

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
14
Figure 9: Wiring of brake switch(12V): 12V is provided by KLS-S controller on pin11
Figure 10: Wiring diagram for motor temperature sensor
3.2.3 Communication Port
A 4pin connector to RS232 port is provided to communicate with host computer for calibration and
configuration.
Figure 11: RS232 Interface on 4pin connector to RS232 converter

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
15
Figure 12:SM-4P connector for communication interface on KLS-S controller
3.3 Installation Check List
Before operating the vehicle, complete the following checkout procedure. Use LED code as
a reference as listed in Table 1.
Caution:
•Put the vehicle up on blocks to get the drive wheels off the ground before beginning
these
tests.
•Do not allow anyone to stand directly in front of or behind the vehicle during the checkout.
•Make sure the PWR switch and the brake is off
•Use well-insulated tools.
•Prohibit trying to connect the controller to user program while the motor is still
running,let
alone change the settings in the user program.
•Make sure the wire is connected correctly
•Turn the PWR switch on. The Green LED stay on steadily and Red LED turns off when the
controller operates normally. If this does not happen, check continuity of the PWR and
return.
•The fault code will be detected automatically at restart.
•With the brake switch open, select a direction and operate the throttle. The motor should
spin in the selected direction. Verify wiring or voltage and the fuse if it does not. The motor
should run faster with increasing throttle. If not, refer to the Table 1 LED code, and correct
the fault as determined by the fault code.
•Take the vehicle off the blocks and drive it in a clear area. It should have smooth
acceleration and good power.

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
16
Chapter 4 Programmable Parameters
KLS Configuration program allow users to set parameters according to the vehicle actual
working environment so as to be at its best.
The default parameters of the controller are not recommended for all applications. Make
sure set the proper parameters before making any test to avoid danger.
Customers can do program on PC software or Android App.The Android Tablet is
prefered.First of all,people need to do Identification angle function for KLS controller before
running the motor.The controller needs to be connected to batteries,motor and throttle before
Identification operation.That is to say,it is not enough to connect only power supply(PWR=pin7)
to batteries for Identification Angle operation.
Please download the instruction how to use Identification angle function from our website.
www.kellycontroller.com/support.php
4.1 Step 1
(1)Low Volt: The min voltage of reporting this fault - Range 18~90
Controller will not operate when battery voltage is near the value so as to protect battery.
Suggestion: Set according to the practical situation.By default,it is set at 18V.
(2)Over Volt: The max voltage of reporting this fault - Range 18~90
Controller will not operate when battery voltage is higher than the value so as to protect battery
and controller.
Suggestion: Set according to the practical situation.
By default,It is 60V for 48V controller.It is 80V for 60V controller.It is 90V for 72V controller.
Controller Rated voltage Under Voltage Range (V) Over Voltage Range(V)
48V 18~60 18~60
60V 18~80 18~80
72V 18~90 18~90
Figure 4.1
(3)Current Percent: Phase Current Percent. Range: 20~100
Functional description: The max motor current is (The Value * Peak Current of the Controller).
Suggestion: Factory default is 100%.

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
17
(4)Battery Limit: Battery Limit Current, Limit the max value of Battery Current. Range: 20~100
Functional description: Set max battery current so as to protect battery. A lower value means a
lower battery output current and better protective effect. But excessively low value will affect
acceleration.
Suggestion: Factory default is 100%.
(5)Identification Angle: Please download the instruction to how to use Identification angle
function from the website.
www.kellycontroller.com/support.php
If you can read 85 in Identification Angle item,that is to say,the system is stable and
normal.Please fill in 170 for Identification Angle item in user program.Then
please click Write button in user program.Please wait a few seconds before restart the power
supply.You will see some info on Monitor screen after power supply is
reset.If you see Reset error on the Monitor screen,that is to say,the auto_Identification is
finished.You can see 85 in the Identification Angle item again.And the controller will
blink error code.This is normal.Please reset the power supply again.Then everything will be
fine.The motor is ready to be drived by the KLS controller.
Range: 85 or 170,nothing else.
(6)TPS Low Err: Hall active pedal, if lower than the value, report the fault of TPS Type. Range:
0~20
(7)TPS High Err: Hall active pedal, if higher than the value, report the fault of TPS Type. Range:
80~100
As you may know,the output of hall throttle from Kelly is about from 0.86V to 4.2V.
Our controller will report 3.3 error code if the output of hall throttle is below 0.5V or above 4.5V
by default.
The controller will think the hall throttle is shorted or damaged if the output is beyond the range
from 0.5V to 4.5V.
You can adjust the threshold voltage below or above 0.5V.The controller will report the 3.3 code
to protect the system according to different types of hall throttle.
Because there are many different hall throttle suppliers in the world.The initial output can not be
always in the range of 0.5V to 4.5V.
But it doesn't make any differences if you choose 0-5V or 3-wire pot for the throttle type.That is
to say,these two settings are only useful for hall active throttle or pedal when you chose throttle
type at 2.
As the same goes,it is valid to adjust the high threshold voltage above 4.5V or below 4.5V.
Usually the hall output voltage is 4.2V Max.If you adjust it to lower value which is near 4.2V,it
may trigger the error code in normal way.
(8)TPS Type: TPS Type, 1:0-5V 3-wire 0-5K pot,5K is normal,2K-20K can be used;2:Hall active

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
18
throttle or pedal. Range: 1~2
(9)TPS Dead Low: TPS Dead Zone Low. Range: 5~40
Functional description: Set throttle effective starting point
Suggestion: Set according to the practical situation, factory default is 20%*5V=1.0V.
(10)TPS Dead High: TPS Dead Zone High. Range: 60~95
Functional description: Set throttle effective ending point
Suggestion: Set according to the practical situation, factory default is 80%*5V=4.0V.
(11)Brake sensor type:Brake sensor type for brake variable regen mode:
1:0-5V 3-wire 0-5K pot,5K is normal,2K-20K can be used;2:Hall active throttle or pedal. Range:
1~2
(12)Brake sensor Dead Low: Brake sensor Dead Zone Low. Range: 5~40
Functional description: Set throttle effective starting point
Suggestion: Set according to the practical situation, factory default is 20%*5V=1.0V.
(13)Brake sensor Dead High: Brake sensor Dead Zone High. Range: 60~95
Functional description: Set throttle effective ending point
Suggestion: Set according to the practical situation, factory default is 80%*5V=4.0V.
(14)Max output Fre: Max output frequency. Unit:Hz
Functional description:It will affect the top speed of the motor.
Suggestion: Set according to the practical situation, factory default is 1000Hz.Please don’t set it
1000Hz above.
(15)Max Speed: Max Speed [rpm]. Range: 0~15000 By default,it is set at 4000.Software
version 0109 can support 15000RPM settings in user program.
(16)Max Fwd Speed %: The forward speed of the percentage of maximum speed. Range:
20~100 By default,it is set at 100%
(17)Max Rev Speed %: The reverse speed of the percentage of maximum speed. Range:
20~100 By default,it is set at 100%
Midspeed Forw speed, Midspeed Rev speed, Lowspeed Forw speed and Lowspeed Rev
speed.Range: 20~100 By default,it is set at 100%.Both F-N-R control and three speed function
used the same pin12.Needless to say,we can not use both functions at the same time.Three
Gears switch is supposed to enable F-N-R control.When this item is disabled,we can use three
speed function,vice versa.
Pin22 is low speed switch input port while Pin12 is high speed switch input port.When both
pin22 and pin12 are disconnected from pin11,the controller is driving with medium speed mode.

Kelly KLS-S Brushless Motor Controller User’s Manual V1.10
19
Three speed:This item is used to enable or disable three speed function.By default,it is at 0
0:Three speed function is disabled.1:Two speed function.2:Three speed function is enabled.
(18)PWM Frequency: Frequency of PWM operation. Unit:KHz
Functional description:20KHz is better for hub motor with strict quiet control.
Suggestion: Set according to the practical situation, factory default is 20KHz.Please don’t set it
20KHz above.
Value Range:10KHz or 20KHz
(19)Start-up H-Pedal:
Value range: Enable and Disable
Functional description: If enabled, the controller will detect the current pedal status at power up.
If throttle got effective output, the controller will report fault and not operate.
Suggestion: Set according to the practical situation, factory default is Enable.
(20)Brake H-Pedal:Releasing Brake High Pedal Disable
Value range: Enable and Disable
Functional description: If enabled, the controller will detect the current pedal status when
release the brake. If throttle got effective output, the controller will report fault and not operate.
Suggestion: Set according to the practical situation, factory default is Disable.
(21)NTL H-Pedal:Neutral position High Pedal Disable.Only useful when Three gears switch
function is enabled.
If enable,the controller will detect the current pedal position or signal When the switch is in
neutral poistion.
If the throttle got effective output signal,the controller will not operate and report fault code.
Suggestion: Set according to the practical situation, factory default is Disable.
(22)Joystick function:
If enable,the controller can drive the motor on two directions without using any reversing switch.
Just one single throttle can drive the motor on forward and reversing direction.
The stick shift throttle firmware can be called wig-wag or joystick operation.It is only a software
function.Usually It is useful for electric boat project.You still can use the common 0-5K pot or
0-5V throttle for the controller.If you don't choose the joystick,you operated the throttle in this
way.The motor speed will increase when the throttle is from 0V to 5V.
If you enable joystick for this controller in user program,you will start the motor from 2.5V
position.2.6V to 5V is forward.2.4V to 0V is backward.
2.4V to 2.6V is the throttle dead zone.Customers can adjust the throttle dead zone in user
program also.
Please note the common throttle will spring back to original position if you release the throttle.
Suggestion:factory default is Disable.
(23)Three Gears switch:It is used for function of F-N-R control.
Please check the wiring diagram in the manual for F-N-R control.
This manual suits for next models
7
Table of contents
Other Kelly Controllers manuals

Kelly
Kelly KLS11601-8080N User manual

Kelly
Kelly KLS6022H User manual

Kelly
Kelly KPM48401KD User manual

Kelly
Kelly KLS72501-8080N User manual

Kelly
Kelly KBL24101X User manual

Kelly
Kelly KLS8425RM User manual

Kelly
Kelly Jaguar KLS-N Series User manual

Kelly
Kelly KLS7212N User manual

Kelly
Kelly KLS4860NE User manual

Kelly
Kelly SPM4812S User manual

Kelly
Kelly KLS2418ND User manual

Kelly
Kelly KDH72101E User manual

Kelly
Kelly KLS-180N User manual

Kelly
Kelly KLS84150RMO User manual

Kelly
Kelly KLS7240ND User manual

Kelly
Kelly KBS48181E User manual

Kelly
Kelly KLS7270NE User manual

Kelly
Kelly KEB Series User manual

Kelly
Kelly KLS11111-8080N User manual

Kelly
Kelly KBL24101 User manual