manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Kennedy
  6. •
  7. Control Unit
  8. •
  9. Kennedy 2945 Series User manual

Kennedy 2945 Series User manual

This manual suits for next models

3

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Kennedy Valve
Indicator Posts
Section
Style 2945A Adjustable Barrel 2-3
AssemblyDrawing 2
Dimensions&Instructions 3
Style 2945 Fixed Length 4-5
AssemblyDrawing 4
Dimensions&Instructions 5
Style 2945 & 2945A Parts List 6
Style 2945 & 2945A Trench Depths for Gate Valves 7
Style 2945 & 2945A Installation & Maintenance 8-10
Style 2945 & 2945A Lower Standpipe Change Instructions 11
Style 2945A Post Extension Instructions 12
Style 641 Wall Type Indicator Post 13
Style 641-14 Flanged Base Post Indicator 14
***Please check our website www.kennedyvalve.com for any product updates and/or changes***
Installation – The valve should be opened to the fully open position before proceeding with the
Indicator Post installation.
1. Disassembly of the Indicator Post Unit
Telescoping Barrel Units
•Remove the Top Section from the end of the barrel.
•Loosen the two screws on the barrel and slide off the top of the standpipe.
Fixed Length Units
•Remove the Top Section from the end of the standpipe.
2. Base Flange Installation:
•Attach the base flange along with the standpipe to the valve plate using the four 5/8”
bolts and nuts provided.
3. Grade Line Adjustments:
Telescoping Barrel Units
•Lower the barrel over the standpipe until the grade line mark on the barrel is at
ground line height and then tighten the two screws securely.
Fixed Length Units
•Cut the required length off the bottom of the standpipe so that the indicated grade line
of the standpipe is at the ground line height and then secure to the base flange by
tightening the two screws.
4. Extension Rod Adjustments:
Lower the stem into the barrel/standpipe, placing the crane coupling over the valve
operating nut.
It is necessary that the stem engage the operating nut a minimum of 2 inches, but not more
than 5 inches.
To check for correct engagement, the end of the stem should be from 7 inches to 10 inches
above the top of the standpipe (Fixed Length Units) or the top of the telescoping barrel.
5. Target (Open and Shut) Adjustments
Remove the target assembly from inside the body by rotating the operating nut
counterclockwise.
Loosen the target retainer screws, but do not remove them.
Open Left Valves
Move the OPEN target to the top of the plate.
Note: Position of the SHUT target can be determined by the following chart:
Valve
Size
4”
6”
8”
10”
12”
14”
Gate
Valve “A”
1”
1 3/8”
1 3/16”
2 3/16”
2 5/8”
3”
RW
Valve “A”
7/8”
1 5/16”
1 11/16”
2 1/8”
2 ½”
NA
Position the SHUT target as indicated below and tighten the retainer screws until snug.
Avoid over tightening. Repeat the procedure for the other side.
Open Right Valves
The procedure is similar as for open left, but with two differences:
A: The open target is placed below the shut target.
B: The open target is placed at the very bottom of the plate.
The position of the shut target above the open target is then determined and set as described
above.
Maintenance
1. Lubrication
Oil upper bearing at least once per year, adding several drops of oil in the hole located on
the top of the main stem flange.
Access to lubrication hole is gained by raising the locking wrench off the main stem nut.
2. Operation
The target mechanism will travel off the threads of the operating nut in both directions
should the targets or target mechanism be positioned incorrectly. Should this happen,
readjust targets. If the target mechanism falls from the operating nut, it will be stopped a
short distance below the window.