TK-2310R
5
REALIGNMENT
4.Wireless Clone Mode
4-1. Outline
“Wireless Clone Mode” copies the transceiver data to an-
other transceiver.
The dealer can copy the transceiver data to another
transceiver even without the use of a personal computer.
4-2. Example
The transceiver can copy the programming data to one or
more transceivers via RF communication.
The clone source and clone target/s must be in wireless
clone mode.
4-3. Operation
1. To switch the clone target/s to Clone mode, press and
holdthe[<B]keywhileturningthetransceiverpowerON.
2. Wait for 2 seconds.“CLONE” appears on the LCD, fol-
lowed by “FRQTBL 1”.
3. Select a channel table number using the [Selector] knob.
4. To switch the clone source to Clone mode, press and
holdthe[<B]keywhileturningthetransceiverpowerON.
5. Wait for 2 seconds.“CLONE” appears on the LCD, fol-
lowed by “FRQTBL 1”.
6. Select the same channel table number as the clone tar-
get/s.
7. Press the [S] key on the clone source to begin data trans-
mission.When the clone target starts to receive data, the
green LED will light and“CLONING” will appear on the
LCD.The source unit will display “MASTER”.
8. When the clone source finishes sending data, a “confir-
mation”tonewillsoundand“COMPLETE”willappearon
the LCD. If data transmission failed while cloning, the tar-
getunitwillproducedanerrortoneand“CLONENG”will
appear on the LCD.
9. If the cloning fails, no data will be available in the target
unit when it is returned to User mode.
10.When the cloning is successful, the target unit's “Scan”
and “Key lock” functions will return to their default values
(Scan=OFF,Keylock=OFF).
11.The source will remain in clone mode after cloning. The
target unit will return to user mode after a successful
cloning.
Note:
• Thedealercanclonedatatotwoormoretransceiversby
repeating the above procedures.
• Ifthe transceiverswirelesscloneMode iscongured as
“Disabled”, the transceiver cannot enter Clone mode.
• The table shown below will cover the frequency tables
used for wireless cloning.
• Wireless clone mode cannot be entered in battery low
state.
• Aunitcannotbea“SourceUnit”ifitisunprogrammed.If
the [S] key is pressed, an “error” tone will sound.
• Onceaunitissettobethesource,itcannotbeatarget
after the data has been transmitted. This protects the
data in the source unit.
• MSKsignalingisusedincloning.
• Electronic interface may cause a failure in data transfer
during Wireless Clone, such as when waveforms or elec-
tromagnetics are being performed at the workbench.
• Wireless clone mode can be used ONLY by the autho-
rized service personnel.
• The wireless clone mode setting must be congured as
“Disable” before being delivered to the end-user.
• To wirelessclone,replace the antennafromboth the
source transceiver and the target transceiver with a dum-
my load.
• ThetransmitoutputpowerisautomaticallysettoLowin
Clone mode.
4-4. Adding the Data Password
If the Data password is set to the transceiver, you must
enter the password to activate a clone mode.The maximum
length of the password is 6 digits.
The following describes how to enter the password.
1. Press and hold the [<B] key for 2 seconds while turning
the transceiver power on.
2. “CLN.LOCK.R”(When the Read authorization password
issettothetransceiver.) /“CLN.LOCK.W” (Whenthe
Overwritepasswordissettothetransceiver.)isdisplayed
on the LCD.
3. Ifthe[selector] knob is rotated while“CLN.LOCK.R”/
“CLN.LOCK.W”isdisplayed,thenumber(0to9)ashes
on the LCD.
When you press the [C>] key, the currently selected num-
ber is determined.
If you press the [A] key, the least digit of the password is
deleted.
If you press the [S] key after entering the password in this
procedure, “FRQTBL 1” is displayed if the entered pass-
word is correct.
Ifthepasswordisincorrect,“CLN.LOCK.R”/“CLN.LOCK.
W” is redisplayed.
• Clone frequency table
No. Operating frequency 245~245.9875 (MHz)
1 245.00000
2 245.05000
3 245.10000
4 245.15000
5 245.20000
6 245.25000
7 245.30000
8 245.35000
9 245.40000
10 245.45000
11 245.50000
12 245.55000
13 245.60000
14 245.65000
15 245.70000
16 245.75000
17 245.80000
18 245.85000
19 245.90000
20 245.95000