TK-3207
6
8. If the cloning fails, no data will be available in the Slave unit
when it is returned to User mode.
9. When the cloning is successful, the Slave unit's "Scan" and
"Key lock" functions will return to their default values (Scan
= OFF, Key lock = OFF).
Notes:
•The dealer can clone data to two or more transceivers by
repeating the above procedures.
•If the transceivers Clone Mode is configured as "Disabled",
the transceiver cannot enter Clone mode.
•The table shown below will cover the frequency tables used
for wireless cloning.
•Clone mode cannot be entered in battery low state.
•Aunit cannot be a "Master Unit" if it is unprogrammed. If
[PTT] is pressed, an "error" tone will sound.
•The language used in cloning depends on the "Model type"
setting, not the FPU setting. C, C2, C5 and C6 type
TK-3207 transceivers will use Chinese. Other types English.
•Once a unit is set to be the Master, it cannot be a slave
after the data has been transmitted. This protects the data
in the Master unit.
•Electronic interface may cause a failure in data transfer
during Wireless Clone, such as when waveforms or
electromagnetics are being performed at the workbench.
•Clone mode can be used ONLY by the authorized service
personnel.
•The Clone mode setting must be configured as "Disable"
before being delivered to the end-user.
•To clone, replace the antenna from both the master
transceiver and the slave transceiver with a dummy
load.
•The transmit output power is automatically set to Low
in Clone mode.
1450.000 440.000 400.000
2452.000 442.000 401.000
3454.000 446.000 402.000
4456.000 448.000 403.000
5458.000 450.000 404.000
6460.000 452.000 405.000
7462.000 454.000 406.000
8464.000 456.000 407.000
9466.000 458.000 408.000
10 468.000 460.000 409.000
11 470.000 462.000 410.000
12 472.000 464.000 411.000
13 474.000 466.000 412.000
14 476.000 468.000 413.000
15 478.000 470.000 414.000
16 480.000 472.000 415.000
17 482.000 474.000 416.000
18 484.000 476.000 417.000
19 486.000 478.000 418.000
20 488.000 480.000 419.000
Clone Frequency Table
Type M C C2
Operating
Clone
Frequency
450~490 440~480 400~430
Frequency (MHz)
Table
1450.000 440.000 400.000
2452.000 442.000 401.000
3454.000 446.000 402.000
4456.000 448.000 403.000
5458.000 450.000 404.000
6460.000 452.000 405.000
7462.000 454.000 406.000
8464.000 456.000 407.000
9466.000 458.000 408.000
10 468.000 460.000 409.000
11 470.000 462.000 410.000
12 472.000 464.000 411.000
13 474.000 466.000 412.000
14 476.000 468.000 413.000
15 478.000 470.000 414.000
16 480.000 472.000 415.000
17 482.000 474.000 416.000
18 484.000 476.000 417.000
19 486.000 478.000 418.000
20 488.000 480.000 419.000
复制频率表
类型 M C C2
操作频率
(MHz) 450~490 440~480 400~430
复制频率表
REALIGNMENT
/
模式组合
注释:
•经销商可以反复上述过程复制数据到 2 个或更多的手持机。
•如果手持机复制模式被设置为“无效”,则手持机不能进入
复制模式。
•下表包含了无线复制用的频率表。
•当电池处于低电压状态时不能进入复制模式。
•如果手持机是非编程的它将不能成为主机。如果按[PTT],将
发出一个 " 错误 " 音。
•复制时所用的语言是根据 " 样机类别 " 设置,而不是 FPU 设
置,TK-3207 的 C,C2,C5 和 C6 类别的手持机用中文,其它
类别用英文。
•手持机一旦被设置为主机,数据传送以后,它就不能成为子
机。这是为了保护主机里的数据。
•在无线复制的数据传输过程中,例如在工作台产生的电波或
电磁干扰有可能引起传输失败。
•复制模式可以仅被批准的服务人员使用。
•在交付给最终用户之前,复制模式设置必须被设置为“无
效”。
•为了复制,将模拟负载代替主手持机和子手持机的天线。
•在复制模式,发射功率自动设定为低。