KERN MPE 200K-1HEM User manual

KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Operating instructions
Personal floor scale with BMI function
KERN MPE
MPE 250K100HNM
MPE 250K100PNM
MPE 200K-1HEM
MPE 200K-1PEM
Version 5.5
2022-02
GB
MPE_HM / MPE_PM-BA-e-2255

2 MPE_HM / MPE_PM-BA-e-2255
D Weitere Sprachversionen finden Sie online unter www.kern-sohn.com/manuals
BG Други езикови версии ще намерите в сайта www.kern-sohn.com/manuals
DK Flere sprogudgaver findes på websiden www.kern-sohn.com/manuals
EST Muud keeleversioonid leiate Te leheküljel www.kern-sohn.com/manuals
E Más versiones de idiomas se encuentran online bajo www.kern-sohn.com/manuals
GR Άλλες γλωσσικές αποδόσεις θα βρείτε στην ιστοσελίδα www.kern-sohn.com/manualss
F Vous trouverez d’autres versions de langue online sous www.kern-sohn.com/manuals
LV Citas valodu versijas atradīsiet vietnē www.kern-sohn.com/manuals
FIN Muut kieliversiot löytyvät osoitteesta www.kern-sohn.com/manuals
LT Kitas kalbines versijas rasite svetainėje www.kern-sohn.com/manuals
GB Further language versions you will find online under www.kern-sohn.com/manuals
RO Alte versiuni lingvistice veţi găţi pe site-ul www.kern-sohn.com/manuals
I Trovate altre versioni di lingue online in www.kern-sohn.com/manuals
SK Iné jazykové verzie nájdete na stránke www.kern-sohn.com/manuals
NL Bijkomende taalversies vindt u online op www.kern-sohn.com/manuals
SLO Druge jezikovne različice na voljo na spletni strani www.kern-sohn.com/manuals
P Encontram-se online mais versões de línguas em www.kern-sohn.com/manuals
CZ Jiné jazykové verze najdete na stránkách www.kern-sohn.com/manuals
PL Inne wersje językowe znajdą Państwo na stronie www.kern-sohn.com/manuals
SE Övriga språkversioner finns här: www.kern-sohn.com/manuals
H A további nyelvi változatok a következő oldalon találhatók: www.kern-sohn.com/manuals
HR Druge jezične verzije su dostupne na stranici: www.kern-sohn.com/manuals
NO Andre språkversjoner finnes det på www.kern-sohn.com/manuals

MPE_HM / MPE_PM-BA-e-2255 3
GB
KERN MPE
Version 5.52022-02
Operating instructions
Personal floor scale with BMI function
Contents
1Technical data ............................................................................................ 5
1.1 Tolerances height meter ........................................................................................ 7
2Declaration of conformity.......................................................................... 8
2.1 Explanation of the graphic symbols for medical devices......................................... 8
3Appliance overview.................................................................................. 11
4Keyboard overview .................................................................................. 13
5Overview of display.................................................................................. 14
6Basic Information (General).................................................................... 14
6.1 Specific function....................................................................................................14
6.2 Proper use............................................................................................................15
6.3 Non-intended product use / contraindications .......................................................16
6.4 Warranty...............................................................................................................17
6.5 Monitoring of Test Resources ...............................................................................17
6.6 Plausibility check...................................................................................................18
6.7 Report of serious incidents....................................................................................18
7Basic Safety Precautions ........................................................................ 19
7.1 Pay attention to the instructions in the Operation Manual......................................19
7.2 Personnel training.................................................................................................19
7.3 Preventing contamination......................................................................................19
7.4 Preparation for use ...............................................................................................19
8Electromagnetic compatibility (EMC)..................................................... 20
8.1 General hints ........................................................................................................20
8.2 Electromagnetic interferences...............................................................................21
8.3 Electromagnetic noise immunity............................................................................22
8.3.1 Crucial features of performance........................................................................................... 24
8.4 Minimum distances...............................................................................................24
9Transport and storage............................................................................. 25
9.1 Testing upon acceptance......................................................................................25
9.2 Packaging / return transport..................................................................................25
10 Unpacking, Setup and Commissioning.................................................. 25
10.1 Installation Site, Location of Use...........................................................................25
10.2 Unpacking.............................................................................................................26
10.3 Scope of delivery ..................................................................................................26
10.3.1 MPE-HM and MPE-PM models ........................................................................................... 26
10.3.2 MPE-HEM and MPE-PEM models....................................................................................... 26
10.4 Balance assembly and installation ........................................................................27
10.4.1 Installing the body height meter........................................................................................... 28
10.5 Mains connection (only MPE-NM models).............................................................29
10.6 Battery operation is possible by obtaining an optional battery power pack............30

4 MPE_HM / MPE_PM-BA-e-2255
10.7 Battery operation...................................................................................................31
10.8 Initial Commissioning............................................................................................32
11 Operation .................................................................................................. 32
11.1 Weighing...............................................................................................................32
11.2 Taring ...................................................................................................................33
11.2.1 Subsequent tare weight ....................................................................................................... 33
11.3 HOLD function......................................................................................................33
11.4 Show second decimal place (non-verified value)...................................................34
11.5 Calculation of the Body Mass Index......................................................................34
11.5.1 Measuring body height (MPE-HM and MPE-HEM only)...................................................... 35
11.5.2 Calculating Body Mass Index............................................................................................... 37
11.5.3 Classification of BMI values................................................................................................. 38
11.6 Automatic switch-off function „AUTO OFF“ ...........................................................38
11.7 Display background illumination............................................................................39
12 The menu .................................................................................................. 40
12.1 Navigation in the menu .........................................................................................40
12.2 Menu overview......................................................................................................41
13 Data output RS 232 .................................................................................. 44
13.1 Pin allocation of balance output bushing:..............................................................44
13.2 Technical data ......................................................................................................44
13.3 Printer operation ...................................................................................................45
14 Error messages........................................................................................ 45
15 Service, maintenance, disposal.............................................................. 46
15.1 Cleaning ...............................................................................................................46
15.2 Cleaning / disinfecting...........................................................................................46
15.3 Sterilisation...........................................................................................................47
15.4 Service, maintenance ...........................................................................................47
15.5 Disposal................................................................................................................47
16 Instant help............................................................................................... 47
17 Verification................................................................................................ 48
17.1 Verification validity period (current status in G).....................................................50
18 Adjustment ............................................................................................... 51
19 Equipment (option) .................................................................................. 53

MPE_HM / MPE_PM-BA-e-2255 5
1 Technical data
KERN (Type)
MPE
250K100HNM
MPE
250K100PNM
Model
MPE
250K100HM
MPE
250K100PM
Display 6-digit
Weighing capacity (max) 250 kg
Minimum load (Min) 2 kg
Verification value (e) 100 g
Repeatability 0.1 kg
Linearity ± 0.1 kg
Display LCD with 25mm high digits
Recommended adjustment
weight, (Class) >200 kg
(M1)
Stabilization time (typical) 3 sec.
Warm-up time 10 min
Operating temperature 0° C …. + 40° C
Humidity of air max. 80 % (not condensing)
Electric Supply Input voltage 100 V - 240 V, 50 / 60 Hz
Auto Off After 3 min without load change (adjustable)
Balance
(W x D x H) mm 365 x 570 x 2134 365 x 570 x 1030
Weighing plate mm 365 x 360 x 80
Weight kg (net) 11.5 10.8
Verification according to
2014/31/EU class III
Medical device according to
93/42/EEC class I with measuring function (lm)
Height measuring stick in
tripod integrated, extendable
(from 88 cm to 205 cm)
-
Rechargeable battery
operation optional; 6 x 1.2 VAA = 7.2 V/2000 mA
Batteries 6 x 1.5 V AA
Data interface
provided as standard RS 232 C

6 MPE_HM / MPE_PM-BA-e-2255
KERN (Type)
TMPE
250K-1HEM-A
TMPE
250K-1PEM-A
Model
MPE
250K-100HEM
MPE
250K-1PEM
Display 6-digit
Weighing capacity (max) 250 kg
Minimum load (Min) 2 kg
Verification value (e) 100 g
Repeatability 0.1 kg
Linearity ± 0.1 kg
Display LCD with 25mm high digits
Recommended adjustment
weight, (Class) >200 kg
(M1)
Stabilization time (typical) 3 sec.
Warm-up time 10 min
Operating temperature 0° C …. + 40° C
Humidity of air max. 80 % (not condensing)
Electric Supply Input voltage 100 V - 240 V, 50 / 60 Hz
Auto Off After 3 min without load change (adjustable)
Balance
(W x D x H) mm 365 x 570 x 2134 365 x 570 x 1030
Weighing plate mm 365 x 360 x 80
Weight kg (net) 11.5 10.8
Verification according to
2014/31/EU class III
Medical device according to
93/42/EEC class I with measuring function (lm)
Height measuring stick in
tripod integrated, extendable
(from 88 cm to 205 cm)
-
Rechargeable battery
operation optional; 6 x 1.2 VAA = 7.2 V/2000 mA
Batteries 6 x 1.5 V AA
Data interface
provided as standard RS 232 C

MPE_HM / MPE_PM-BA-e-2255 7
Note on “Medical product in accordance with 93/42/EEC”
1.1 Tolerances height meter
Measured value (cm) Tolerance (cm)
90 ± 0.5
100 ± 1.0
150 ± 1.0
200 ± 1.0

8 MPE_HM / MPE_PM-BA-e-2255
2 Declaration of conformity
To view the current EC/EU Declaration of Conformity go to:
www.kern-sohn.com/ce
The scope of delivery for verified weighing balances (= conformity-rated
weighing balances) includes a Declaration of Conformity.
Solely these weighing balances are classified as medical devices.
2.1 Explanation of the graphic symbols for medical devices
All medical scales marked in this way meet the
requirements of the following directives:
1. 2014/31/EU: Directive on non-
automatic weighing
instruments
2. 93/42/EC: Directive concerning medical devices
for
“Medical product in accordance with
93/42/EEC”
Scales marked in this way underwent the conformity
assessment procedure according to Directive
2014/31/EU for scales belonging to 3rd accuracy class.
WF 170012
Designation of the serial number of every device, applied
at the device and on the packaging
Number here as example
2022-02
Identification of the manufacturing date of the medical
product.
Year and month here as example

MPE_HM / MPE_PM-BA-e-2255 9
“Please note the accompanying documents“
or “Please note the operating instructions”
“Please note the operating instructions”
“Please note the operating instructions”
Kern & Sohn GmbH
D–72336 Balingen,Germany
www.kern-sohn.com
Identification of manufacturer of medical product
including address
“Electro-medical appliance“
with attachment for type B
Device protection category II
Dispose of old appliances separately from your
household waste!
Instead, take them to communal collection points.
12 V DC / 500 mA
Display of supply voltage for scales with polarity display.

10 MPE_HM / MPE_PM-BA-e-2255
Mains connection
Sealing mark KERN SEAL
Supply voltage direct current
Information
Level balance before use
Electrostatically endangered structural components

MPE_HM / MPE_PM-BA-e-2255 11
3 Appliance overview
1. Height measuring stick
(MPE-HM models only)
2. Display Unit
3. Weighing platform
(anti-slip surface)
4. Rubber feet
(height adjustable)
Underside
5.Rolls

12 MPE_HM / MPE_PM-BA-e-2255
Secondary display at rear
Display unit at rear
5 Rechargeable battery
compartment
6 Mains connection
(MPE-NM)
7 RS 232 C

MPE_HM / MPE_PM-BA-e-2255 13
4 Keyboard overview
Type MPE 250K100HNM
Type MPE 250K100PNM
Type TMPE 250K-1HEM-A
Type TMPE 250K-1PEM-A
Key Description Function
ON/OFF-switch Turn on/off
HOLD button Hold function/Calculation of a stable weight value
or BMI key Calculation of the Body Mass Index
PRINT button
Data transfer via interface
In menu:
•Confirm selection
For numeric entry:
•Confirm numerical value
Function key In menu:
•Call up menu
•How to select menu items
For numeric entry:
•Increase numerical value
Zeroing key Weighing scale will be reset to „0.0“
For numeric entry:
•Change decimal place
TARE key Tare balance

14 MPE_HM / MPE_PM-BA-e-2255
5 Overview of display
Display Description Description
Stability display Scales are in a steady state
Zeroing display Should the balance not display exactly
zero despite empty weighing plate, press
the button. Your balance will be set to
zero after a short standby time.
NET Net weight display Illuminated when net weight is displayed
Illuminated after weighing scale was tared
GROSS Gross weight display Illuminated when gross weight is displayed
HOLD HOLD function HOLD function active
BMI BMI function Illuminated while BMI function is enabled
6 Basic Information (General)
Weighing instruments have to be verified for the purposes stated
below in accordance with Directive 2014/31/EC.
Article 1,
paragraph 4. “Determination of mass in the practice of medicine
that is, weighing patients for reasons of medical supervision
during medical surveillance, examination and treatment.”
6.1 Specific function
Indication
•Determining the body weight in the medical practice area.
•Use as „non-standalone weighing scale“, that is, a person
steps carefully onto the weighing platform‘s centre. Once a
steady display value is shown, you can read the weight value.
Contra-
indication
•No contraindication known

MPE_HM / MPE_PM-BA-e-2255 15
6.2 Proper use
This weighing scale is designed for determining the weight of a person whilst
standing, such as in doctor’s surgeries. The balance is suitable for recognising,
preventing and controlling illnesses.
Scales fitted with a serial interface may only be connected to
appliances in compliance with Directive EN60601-1.
On personal weighing scales, the person should step onto the centre of the weighing
platform and remain standing without moving.
As soon as a stable weighing value is reached the weighing value can be read.
The weighing scale is designed for continuous duty.
The weighing platform may only be stepped on by persons
capable of standing on both feet on the weighing platform.
The weighing platforms are fitted with an anti-slip surface that must not be covered
during weighing a person.
The balance should be checked for correct condition prior to each utilisation by a
person familiar with proper operation of the balance.
When using balance with body height measuring rod, ensure that the top flap is
turned downwards immediately after use in order to avoid risk of injury.
If the balance doesn’t have any contact with the transfer cable,
do not touch the transfer port in order to avoid an ESD-failure.

16 MPE_HM / MPE_PM-BA-e-2255
6.3 Non-intended product use / contraindications
Do not use these scales for dynamic weighing processes.
Do not leave permanent load on the weighing pan. This may
damage the measuring system.
Impacts and overload exceeding the stated maximum load (max)
of the weighing plate, minus a possibly existing tare load, must
be strictly avoided. This could cause damage to the balance.
Never operate balance in explosive environment. The serial
version is not explosion protected. It should be noted that a
flammable mixture of anaesthetics and oxygen or laughing gas
may occur.
The structure of the balance may not be modified. This may lead
to incorrect weighing results, safety-related faults and destruction
of the balance.
The balance may only be used according to the described
conditions. Other areas of use must be released by KERN in
writing.
If the balance is not used for a longer time, take out the batteries
and store them separately. Leaking battery liquid could damage
the balance.
Improper use of the optional height meter
The height meter may only be assembled such as described in
the operating instructions. The structure of the body height
measuring rod may not be modified. This may cause incorrect
measurement results, safety-related faults as well as destruction.
The height meter may only be used according to the defined
specifications. Other areas of use must be released by KERN in
writing.

MPE_HM / MPE_PM-BA-e-2255 17
6.4 Warranty
Warranty claims shall be voided in case
•Our conditions in the operation manual are ignored
•The appliance is used outside the described uses
•The appliance is modified or opened
•Mechanical damage and damage caused by media, liquids,
•Natural wear and tear
•The appliance is improperly set up or incorrectly electrically connected
•The measuring system is overloaded
•Dropping the balance
6.5 Monitoring of Test Resources
In the framework of quality assurance the measuring-related weighing properties of
the balance and, if applicable, the testing weight, must be checked regularly. The
responsible user must define a suitable interval as well as type and scope of this test.
Information is available on KERN’s home page (www.kern-sohn.com with regard to
the monitoring of balance test substances and the test weights required for this. In
KERN’s accredited DKD calibration laboratory test weights and balances may be
calibrated (return to the national standard) fast and at moderate cost.
Using measuring technology to check the accuracy of the measuring device is
recommended for personal floor scales with body height measurement but is not
absolutely essential as the calculation of the human body height is always subject to
a great deal of inaccuracy.

18 MPE_HM / MPE_PM-BA-e-2255
6.6 Plausibility check
Please make sure that the measurement values computed by the appliance are
plausible and are allocated to the respective patient, before storing and using the
values for further purposes. This applies especially also for values transferred via
interface.
6.7 Report of serious incidents
All serious incidents appeared related to this product must be reported to the
manufacturer and the responsible authority of the member state where the user
and/or the patient are residents.
„Serious incident“ that means an incident which directly or indirectly had, could have
or could have had one of the following consequences:
the death of a patient, a user or another person,
the temporary or permanent fatal deterioration of the health status of a patient,
a user or other persons,
a serious danger for public health,

MPE_HM / MPE_PM-BA-e-2255 19
7 Basic Safety Precautions
7.1 Pay attention to the instructions in the Operation Manual
Carefully read this operation manual before
setup and commissioning, even if you are
already familiar with KERN balances.
7.2 Personnel training
The medical staff must apply and follow the operating instructions for proper use and
care of the product.
7.3 Preventing contamination
The prevention of cross-contamination (fungal skin infections …) requires regular
cleaning of the weighing platform. Recommendation: after a weighing procedure that
could potentially result in contamination (e. g. after weighing that involves direct skin
contact).
7.4 Preparation for use
•Check the personal balance for damage before any use
•Maintenance and re-verification (in Germany MTK)
The personal balance must undergo maintenance and re-verification at regular
intervals.
•Do not use the appliance on slippery surfaces or in rooms with risk of vibration
•During installation the personal balance must be levelled.
•If possible, the product must remain in its original packaging during the
transport. Should this not be possible, make sure that the product is protected
against damage.
•Step onto and leave the personal balance only when a qualified person is
present

20 MPE_HM / MPE_PM-BA-e-2255
8 Electromagnetic compatibility (EMC)
8.1 General hints
The installation and use of this electrical medical device requires
special precautionary measures as outlined in the EMC information
below.
This device complies with the limits set for medical electrical devices of group 1,
class B (as per EN 60601-1-2).
Electromagnetic compatibility (EMC) describes a device’s ability to perform reliably
within an electromagnetic environment without causing inadmissible electromagnetic
interference at the same time. Amongst other things, such disturbances may be
emitted by connecting cables or the air.
Inadmissible disturbances from the environment may result in incorrect displays,
inaccurate measured values or incorrect behaviour of the medical device. By the
same token the medical device may in some cases cause such disturbances in other
devices. To eliminate problems of that kind, we recommend you to take one or
several of the measures listed below:
•Change the alignment or distance of the device to the source of EMI.
•Install or use the floor scales MPE at a different location.
•Connect the floor scales MPE to a different power source.
•For further questions please contact our customer services.
Disturbances may be caused by improper modification or add-ons to the device or
not recommended accessories (such as power units or connecting cables). The
manufacturer will not be responsible for these. Modifications may also result in a loss
of authorisation relating to the use of the device.
Devices emitting high frequency signals (mobile telephones, radio
transmitters, radio receivers) may cause interference in the floor scale
MPE. For that reason do not use them near the floor scale MPE.
Chapter 8.4 contains details about recommended minimum distances.
This manual suits for next models
3
Table of contents
Other KERN Scale manuals

KERN
KERN EMB-S Series User manual

KERN
KERN FCB Series User manual

KERN
KERN FCE 3K1N User manual

KERN
KERN PCD 250-3 User manual

KERN
KERN CCS 6K-6 User manual

KERN
KERN CPB 15K0.5 User manual

KERN
KERN ILT 12K0.1DM User manual

KERN
KERN PBJ Series User manual

KERN
KERN 466 Series User manual

KERN
KERN MWB series User manual