Keylite KL/RX2 User manual

KL/RX2
Master Control Panel
230v
Remote
Control
Rain Sensor
MASTER
CONTROL
PANEL
KL/Rx2
Motor 2
Motor 1
Blind 1
Blind 2
24v
24v
KL/RX2 MAXIMUM OPERATIONAL
CAPACITY IS 2 MOTORS & 2 BLINDS
*NOT AVAILABLE FOR 4 MOTORS*
24v 24v
Transformer
24v
MAINS
SUPPLY
KL/RX2-2012G
Kit Contents: KL/RX2 Master Control Panel, 24v 2.7A Power Supply,
Rain Sensor, Remote Control

KL/RX2
Master Control Panel
It is recommended that mains voltage to
the transformer is fed through a switched
fused spur with a 3 amp fuse
KL/RX2-2012G
THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED
WIRING OF THE MASTER CONTROL
WINDOWS & BLIND CONNECTIONS
RAIN SENSOR
WARNING!
ONLY TO BE CONNECTED BY
A QUALIFIED ELECTRICIAN
4 core cable from motor:
BROWN | WHITE | YELLOW | GREEN
Discard YELLOW & GREEN cores
All cables are to be a minimum of 0.75mm
cable
RAIN SENSOR FACTORY FITTED TO WINDOW
Fig. A
Fig. B

KL/RX2
Master Control Panel
• Switch on Remote Control.
• Press the RC button in panel (Fig A)
Red LED will light (Fig B)
• Press any button on the hand held remote control.
Red LED in panel will flash (Fig B)
• Remote Control has been programmed.
• To delete all of the programming, press and hold the black RC button (Fig A) until
LED in panel stops flashing.
Leave for 10 seconds before re-programming.
KL/RX2-2012G
THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED
REMOTE CONTROL PROGRAMMING
Button 1 on the remote control will OPEN the window(s). This will operate W+ and W- on OUTPUTS 1 & 2
simultaneously and can be stopped at any point by pressing button 1.
Button 3 on the remote control will CLOSE the window(s). This will operate W+ and W- on OUTPUTS 1 & 2
simultaneously.
Button 2 on the remote control will OPEN the blind(s). This will operate B+ and B- on OUTPUTS 1 & 2
simultaneously and can be stopped at any point by pressing button 2.
Button 4 on the remote control will CLOSE the blind(s). This will operate B+ and B- on OUTPUTS 1 & 2
simultaneously.
REMOTE CONTROL OPERATION:
The KL/RX2 control panel can be used for a range of different operations, from operating 1
electric window and/or electric blind to 2 windows + 2 blinds.
DIP SWITCHES FOR WINDOW & BLIND MOTORS
DIP SWITCHES FOR WINDOW MOTORS ONLY
DIP SWITCHES 3 & 4 IN
THE ON POSITION AND
1 & 2 IN THE OFF POSITION
DIP SWITCHES 1 & 2 IN
THE ON POSITION AND
3 & 4 IN THE OFF POSITION
This will make outputs B+ and B- operate from buttons 2 & 4
and the rain sensor will NOT close the blinds upon detection
of rain
This will make outputs B+ and B- operate from buttons 1 & 3
and the rain sensor will close the blinds upon detection of rain

KL/RX2
Master Control Panel
REMOTE CONTROL
1) LED does not come on when a button is pressed.
- Ensure that the slide switch is in the on position.
- Replace the battery.
KL/RX2 MASTER CONTROL PANEL
1) Receive LED does not come on when a button is pressed on the remote control.
- Ensure that there is a 24V DC supply to the control panel.
- Ensure that the remote control is programmed to the control panel by following the
instructions on the previous page.
- Check the aerial connection for signs of damage.
2) The window closes with button 1.
- The wires on connections W+ and W- need to be reversed.
3) The blind closes with button 2.
- The wires on connections B+ and B- need to be reversed.
4) The rain sensor opens the window
- The wires on connections W+ and W- need to be reversed.
5) The rain sensor does not operate
- Please ensure that the wires connected to the rain sensor connector are correct and are
made with a secure connection.
FOR THE LATEST TROUBLE SHOOTING GUIDE PLEASE REFER TO
http://keyliteroofwindows.com/downloads/
KL/RX2-2012G
THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED
TROUBLE SHOOTING
Technical Data Intended Use
Type
Nominal Voltage
Rated Power
Temperature Range
Output Voltage
Safe output rated current
:KL/CTR6S
:110-240VAC, 47-63Hz
:1.4A
:0-40°C
:24V DC
:2.7A
- Ventilation and blind control of roof windows.
- Integrated receiver for radio remote control.
- Radio frequency 433MHz - approved for use in
Australia, Brazil, Europe, Malaysia,
New Zealand, Russia, Singapore, South Africa.
- Keeloq Rolling Code
- Multiple control panels controllable with only
one remote control.
- Only for inside mounting

KL/RX2
Master Control Panel
PLEASE ENSURE THE FOLLOWING PRECAUTIONS ARE TAKEN WHEN USING ANY OF THE PRODUCTS:
1. Disconnect the main electrical supply before carrying-out any work.
2. Ensure no forces act on the switch terminals after installation.
3. NB. There is a danger to life and risk of injury with electrically operated windows!
The window motor stops by an electronic ‘limit stop’ or ‘overload cut-off’. The resulting forces are strong
enough to crush body parts. Please attach the safety sticker to be clearly visible on the frame of the roof
window. Please ensure that occupants are aware that the window can be closed automatically or by a
remote switch.
4. We recommend only a suitably qualified electrician should install and connect all electrical devices.
INSTALLATION PROCEDURES:
KL/RX2-2012G
THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED
MOTOR INSTALLATION
If the interior ceiling is not finished, the cable can
be passed through the pre-drilled hole by removing
the thimble (fig 1a).
1a
Please note:
All Installation Procedures are viewed from inside the room.
1b
If the ceiling is finished a 10mm hole must be
drilled through the top of the frame (figs 1b, 1c &
1d), 20mm down from top and 145mm in from
the side of the frame.
1c 1d
20mm
145mm
2a 2b
Feed the cable up through the hole (fig. 2a or 2b).
SAFETY PROCEDURES

KL/RX2
Master Control Panel
KL/RX2-2012G
THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED
Please make sure there is approximately 500mm of
cable remaining in the room (fig 3).
NB. If your kit contains a rain sensor it should be
connected and fitted at this stage.
Now ensure all components are correctly wired up
as per wiring diagram supplied with your kit.
NB. If your kit contains a wall mounted switch it should be
connected and fitted at this stage. (Please follow wiring
diagram supplied with your kit.)
3
Attach the motor mounting bracket to the latch
keep timber using 4 No. 25mm screws (fig 4).
Centre the bracket on either side of the latch keep.
4
Latch Keep Timber
Plug the cable into the motor, ensuring that it is fully
connected (fig 5).
NB. If your kit contains a remote control it should be
programmed at this stage. (Please follow programming
instructions as per wiring detail.)
5
Fix the motor using 2 No. shoulder bolts. Ensure
that the chain connector is facing inwards to the
right of the latch keep (circled in fig 6). Once
the motor is securely in position, feed the excess
cable back up through the top of the frame.
6

KL/RX2
Master Control Panel
KL/RX2-2012G
THE INSTALLATION OF THIS SYSTEM MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
THE GUARANTEE WILL BE VOIDED IF THIS IS NOT FOLLOWED
In order to attach the sash to the motor, fully
extend the chain connector by pressing the
down-arrow button on the wall mounted switch
(fig 7). If you have opted not to fit a wall mounted
switch you will then have to activate it using your
remote control.
7
Once the chain is fully extended, use the
connector bar to attach the chain to the vent
flap bracket. Ensuring that you keep the chain
straight, line up the vent flap bracket as shown
(fig 8) and mark.
8
Drill a 5mm hole through the vent flap (fig 9).
9
Attach the vent flap bracket using 1 No. 16mm
bolt and dome head nut (fig 10).
10
Feed the connector bar through the vent flap
bracket and the chain connector. Secure with the
cotter pin (fig 11).
11

www.keyliteroofwindows.com
Table of contents
Popular Control Panel manuals by other brands

mr. steam
mr. steam SMART/ONE Installation & operation instructions

KEBCO
KEBCO COMBICONTROL C6 HMI instruction manual

Paradox
Paradox Digiplex Reference & installation manual

WindowMaster
WindowMaster FlexiSmoke WSC 520 Utilization examples

PureLink
PureLink PureTools PT-CON-WP8B user manual

Exor
Exor eTOP600 Series operating instructions

C & K Systems
C & K Systems SECURIT ST800L+ user manual

Keyautomation
Keyautomation 900CT-BR6 manual

Zero88
Zero88 Chillinet Instructions for installing and operating

Heath Zenith
Heath Zenith Lighting Control Panel 598-1136-04 owner's manual

Abus
Abus AZAA10000 quick guide

Vanguard
Vanguard V5 Operator's manual