Keysight 909A User manual

Keysight 909A/D Coaxial
Terminations
Operating
and Service
Manual



Keysight 909A/D Coaxial Terminations Operating and Service Manual
Notices
© Keysight Technologies 2000 - 2014
No part of this manual may be reproduced in
any form or by any means (including
electronic storage and retrieval or
translation into a foreign language) without
prior agreement and written consent from
Keysight Technologies as governed by
United States and international copyright
laws.
Manual Part Number
00909-90034
Edition
Edition 5, August 2014
Printed in Malaysia
Keysight Technologies
Phase 3 Bayan Lepas Free Industrial Zone
Bayan Lepas, Penang 11900 Malaysia
Warranty
The material contained in this
document is provided “as is,” and is
subject to being changed, without
notice, in future editions. Further, to the
maximum extent permitted by
applicable law, Keysight disclaims all
warranties, either express or implied,
with regard to this manual and any
information contained herein, including
but not limited to the implied
warranties of merchantability and
fitness for a particular purpose.
Keysight shall not be liable for errors or
for incidental or consequential
damages in connection with the
furnishing, use, or performance of this
document or of any information
contained herein. Should Keysight and
the user have a separate written
agreement with warranty terms
covering the material in this document
that conflict with these terms, the
warranty terms in the separate
agreement shall control.
Technology Licenses
The hardware and/or software described in
this document are furnished under a license
and may be used or copied only in
accordance with the terms of such license.
Restricted Rights Legend
U.S. Government Restricted Rights.
Software and technical data rights granted
to the federal government include only
those rights customarily provided to end
user customers. Keysight provides this
customary commercial license in Software
and technical data pursuant to FAR 12.211
(Technical Data) and 12.212 (Computer
Software) and, for the Department of
Defense, DFARS 252.227-7015 (Technical
Data - Commercial Items) and DFARS
227.7202-3 (Rights in Commercial Computer
Software or Computer Software
Documentation).
Safety Notices
CAUTION
A CAUTIONnotice denotes a haz-
ard. It calls attention to an operat-
ing procedure, practice, or the like
that, if not correctly performed or
adhered to, could result in damage
to the product or loss of important
data. Do not proceed beyond a
CAUTIONnotice until the indicated
conditions are fully understood and
met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly per-
formed or adhered to, could result
in personal injury or death. Do not
proceed beyond a WARNING
notice until the indicated condi-
tions are fully understood and
met.
Certification
Keysight Technologies certified that this
product met its published specifications at
the time of shipment from the factory.
Keysight Technologies further certifies that
its calibration measurements are traceable
to the United States National Institute of
Standards and Technology (NIST, formerly
NBS), to the extent allowed by the
Institute’s calibration facility, and to the
calibration facilities of other International
Standards Organization members.

Keysight 909A/D Coaxial Terminations Operating and Service Manual 3
WEEE Compliance
This product complies with the WEEE Directive (2002/96/EC)
marking requirements. The affixed label indicates that you must
not discard this electrical/electronic product in domestic
household waste.
Product Category: With reference to the equipment types in the
WEEE Directive Annex I, this product is classed as a
“Monitoring and Control Instrumentation” product.
Do not dispose in domestic household waste.
To return unwanted products, contact your local Keysight
office, or see www.keysight.com for more information.

4 Keysight 909A/D Coaxial Terminations Operating and Service Manual
Contacting Keysight
For more information, please contact your nearest
Keysight office.
Or, go to www.keysight.com/find/assist for more information.
Americas
Canada
Latin America
United States
(877) 894-4414
305 269 7500
(800) 829-4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Thailand
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
81 426 56 7832
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
1 800 226 008
Europe
Austria
Belgium
Denmark
Finland
France
Germany
Ireland
Italy
Netherlands
Spain
Sweden
Switzerland (French)
Switzerland (German)
United Kingdom
Other European Countries:
0820 87 44 11
32 (0) 2 404 93 40
45 70 13 15 15
358 (0) 10 855 2100
0825 010 700
01805 24 6333
1890 924 204
39 02 92 60 8484
31 (0) 20 547 2111
34 (91) 631 3300
0200-88 22 55
41 (21) 8113811 (Opt 2)
0800 80 53 53 (Opt 1)
44 (0) 118 9276201
www.keysight.com/find/contacts

Keysight 909A/D Coaxial Terminations Operating and Service Manual 5
Contents
1Introduction 7
Product Overview 8
909A Coaxial Termination 8
909D Coaxial Termination 9
2 Specifications 11
Product Specifications 12
Physical Specifications 13
Pin Depth Specifications 13
3 Installation and Service 15
Installation 16
Initial Inspection 16
Service Instructions 17
Adjustment 17
Repair 17
Maintenance 17
Cleaning Connectors 17
Connections 19
Handling and Storage 23

6Keysight 909A/D Coaxial Terminations Operating and Service Manual
Contents

8Keysight 909A/D Coaxial Terminations Operating and Service Manual
Product Overview
The Keysight 909A and 909D terminations are low-
reflection loads for terminating 50Ωcoaxial systems in their
characteristic impedance. The Keysight 909A is extremely
broadband, covering the frequency range from DC to 18GHz.
The Keysight 909D is specified to 26.5GHz, and mode free to
34GHZ. Both terminations find wide use as accessories for
broadband measuring instrument and for coaxial
instrumentation.
909A Coaxial Termination
The Keysight 909A is furnished with a Precision 7mm
connector. This is a sexless connector with low RF leakage and
clearly defined reference plane. As an option, the Keysight 909A
can be furnished with either male or female Type-N connector
interfaces per IEEE standard 287 GPC. The outer conductors of
these Type-N interfaces are made of passivated stainless steel.
Figure 1-1Keysight 909A with male and female Type-N connector

Keysight 909A/D Coaxial Terminations Operating and Service Manual 9
909D Coaxial Termination
The Keysight 909Dhas Precision 3.5mm connector interfaces
per IEEE standard 287 GPC.
Figure 1-2Keysight 909D Coaxial Terminations

10 Keysight 909A/D Coaxial Terminations Operating and Service Manual

12 Keysight 909A/D Coaxial Terminations Operating and Service Manual
Product Specifications
Model Number909A 909D
FrequencyRangeDCto18GHz DC to26.5GHz
Impedance50Ω50Ω
ConnectorsOption 701Precision 7mm
Option 012Type N(m)
Option 013Type N(f)
Option011 3.5mm (f)
Option3013.5mm (m)
Option0403.5mm (m)
Reflection Coefficient Option 701
•DCto 4GHz :0.024(1.05SWR)
•4to 12.4GHz : 0.048 (1.10SWR)
•12.4to 18GHz:0.110(1.25SWR)
Option012and013
•DCto 4GHz :0.029(1.06SWR)
•4to 12.4GHz : 0.052 (1.11SWR)
•12.4to 18GHz:0.130(1.30SWR)
Option011and301
•DCto 3GHz :0.01(1.02SWR)
•3 to 6GHz :0.02(1.04SWR)
•6 to 26.5GHz:0.06(1.12 SWR)
Option 040
•DCto 4GHz :0.01(1.02SWR)
•4 to 6GHz :0.02(1.04SWR)
•6 to 26.5GHz:0.06(1.12 SWR)
Power Rating 2W average
300Wpeak
2W average*
100Wpeak (10psmax. pulsewidth)
at 20°C
*Derated to1Waverageat 75°C

Keysight 909A/D Coaxial Terminations Operating and Service Manual 13
Physical Specifications
Keysight 909A Physical Specifications
Keysight 909D Physical Specifications
Pin Depth Specifications
Keysight 909A Pin Depth in Micrometers (10-4inches)
Keysight 909D Pin Depth in Micrometers (10-4inches)
Option 701Option 012Option 013
Length45mm (1.77in)52mm (2.05in)52mm (2.05in)
Diameter22mm (0.87in)21mm (0.83in)18mm (0.71in)
Weight59g(2.08oz)52g(1.83oz)50g(1.76oz)
ShippingWeight0.45kg (0.99lb)0.45kg (0.99lb)0.45kg (0.99lb)
Option 011 Option 301 and 040
Length 23mm (0.91in)24mm (0.94in)
Diameter 8mm (0.16in)9mm(0.35in)
Weight 7g(0.25oz) 7g(0.25oz)
ShippingWeight0.45kg (0.99lb)0.45kg (0.99lb)
Option 701 Option 012 Option 013
-7.9 to -98.4
(-2 to -25)
0to -157.5
(0to -40)
0 to-118.1
(0to-30)
Option 011 Option 040 Option 301
0to -78.8
(0to -20)
0to -78.8
(0to -20)
0to-78.8
(0to-20)

14 Keysight 909A/D Coaxial Terminations Operating and Service Manual
Environmental Specifications
Parameter Required Values/Ranges
Temperature
•Operation+15°Cto +35°C(+59°F to +95°F)
•Storage-40°C to+75°C (-40°Fto+167°F)
Altitude
•Operation<4,500m(15,000ft)
•Storage<15,000m (50,000ft)
RelativehumidityAlwaysnon-condensing
•Operation 0%to80% (26°C maximumdrybulb)
•Storage 0% to 95%
Vibration 0.015”,5-55-5Hz,15min,3 axes
Shock 100g,1-2ms,3times eachplane

Keysight 909A/D Coxial Terminations
Operating and Service Manual
3
Installation and Service
Installation 16
“Initial Inspection" on page 16
Service Instructions 17
“Adjustment" on page 17
“Repair" on page 17
Maintenance 17
“Cleaning Connectors" on page 17
“Connections" on page 19
“Handling and Storage" on page 23
This chapter provides you installation and service information.

16 Keysight 909A/D Coaxial Terminations Operating and Service Manual
Installation
Initial Inspection
1Unpack and inspect the shipping container and its contents
thoroughly to ensure that nothing was damaged during
shipment. If the shipping container or cushioning material is
damaged, the contents should be checked both mechanically
and electrically.
2If the contents are incomplete, if there is mechanical damage
or defect, or if the instrument does not pass the electrical
performance test, contact the nearest Keysight Technologies
Sales and Service office. Refer to the Service and Support
information in the front matter of this manual. Keysight
Technologies will arrange for repair or replacement of the
damaged or defective equipment. Keep the shipping
materials for the carrier’s inspection.
3If you are returning the instrument under warranty or for
service, repackaging the instrument requires original
shipping containers and materials or their equivalents.
Keysight Technologies can provide packaging materials
identical to the original materials. Refer to Service and
Support information in the front matter of this manual for
the Keysight Technologies nearest to you. Attach a tag
indicating the type of service required, return address, model
number, and serial number. Mark the container FRAGILE to
insure careful handling. In any correspondence, refer to the
instrument by model number and serial number.

Keysight 909A/D Coaxial Terminations Operating and Service Manual 17
Service Instructions
Adjustment
The coaxial terminations does not have internal adjustments
and should not be opened.
Repair
The coaxial terminations are not recommended for repair. In
case your coaxial terminations require repair services, please
contact your nearest Keysight Sales and Service Center.
Maintenance
The connectors, particularly the connector faces, must be kept
clean. Keysight recommends that the connectors be periodically
inspected and cleaned if necessary.
Cleaning Connectors
Clean connectors are essential for ensuring the integrity of RF
and microwave coaxial connectors.
1Use Compressed Air or Nitrogen
Use compressed air (or nitrogen) to loosen particles on the
connector mating plane surfaces.
WARNING Always use protective eyewear when using compressed air or
nitrogen.

18 Keysight 909A/D Coaxial Terminations Operating and Service Manual
You can use any source of clean, dry, low-pressure
compressed air or nitrogen that has an effective oil-vapor
filter and liquid condensation trap placed just before the
outlet hose.
Ground the hose nozzle to prevent electrostatic discharge,
and set the air pressure to less than 414kPa (60psi) to
control the velocity of the air stream. High-velocity streams
of compressed air can cause electrostatic effects when
directed into a connector. These electrostatic effects can
damage the device.
2Clean the Connector Threads
Use a lint-free swab or cleaning cloth moistened with
isopropyl alcohol to remove any dirt or stubborn
contaminants on a connector that cannot be removed with
compressed air or nitrogen.
aApply a small amount of isopropyl alcohol to a lint-free
cleaning swab.
bClean the connector threads.
cLet the alcohol evaporate, then blow the threads dry with
a gentle stream of clean, low-pressure compressed air or
nitrogen. Always completely dry a connector before you
reassemble or use it.
WARNING Keep isopropyl alcohol away from heat, sparks and flame. Store in a
tightly closed container. It is extremely flammable. In case of fire,
use alcohol foam, dry chemical or carbon dioxide; water may be
ineffective.
Use isopropyl alcohol with adequate ventilation and avoid contact
with eyes, skin and clothing. It causes skin irritation, may cause eye
damage and is harmful if swallowed or inhaled. It may be harmful if
absorbed through the skin. Wash thoroughly after handling.
In case of spill, soak up with sand or earth. Flush spill are with
water.
Dispose of isopropyl alcohol in accordance with all applicable
federal, state and local environmental regulations.
This manual suits for next models
1
Table of contents
Popular Touch Terminal manuals by other brands

Mitsubishi Electric
Mitsubishi Electric GOT2000 Series user manual

National Instruments
National Instruments TBX-1303 manual

Partner
Partner SP-1060 IoT Ready quick start guide

Lear Siegler
Lear Siegler ADM-2 Maintenance manual

Slice
Slice REGISTER user guide

Digital Equipment
Digital Equipment VT131 user guide