Kiloview MG300 User manual

MG300 v2 Media Gateway
Easily Bridges Most IP Protocols
(2022-11 version)
Leading solution provider of IP-based video transmission
Quick Start Guide
Contents
Packing List
Device interfaces and functions
Device connection, login and use guide
Device upgrade and restore to factory settings
Before using this product, it is recommended that you read the guide carefully. To ensure your personal safety and avoid physical or electrical damage to the
device, please strictly follow the instructions of this guide to install and use it under the guidance of professionals. Incorrect electrical connections or physical
installation may cause permanent damage to the device and even threaten personal safety.

1
1 Packing List
(1) MG300 v2 ×1
(2) Power Supply ×1
(3) Warranty Card ×1
(4) Quick Start Guide ×1

2
2 Device Interfaces
(1) SDI output
(2) LINE OUT
(3) HDMI output 1
(4) HDMI output 2
(5) Reset
(6) 1000M Ethernet Port 1
(7) 1000M Ethernet Port 2
(8) Type-C Expansion Port
(9) USB Expansion Port
(10) Power Port
(11) Working Indicator
3 LED Indicators
Name
Color
Status
Description
ON
Power connected
Power
Red
OFF
Power off or failure
Flashing
Working
LED Indicators
Run
Green
Always ON/OFF
Device is abnormal or not started

3
4 Application
Note
Please use the equipped power adapter to power the device. Other unqualified power supplies may damage the device.
Connect your Ethernet cable to NET 1 port.
MG300 v2 supports up to 9-channel decoding, HDMI and SDI output same or different contents.
HDMI Monitor
Switch
IP Stream
PC
DC12V Power Supply
SDI Monitor

4
5 Login to the device web page
Login to the device webpage via the default IP address 192.168.1.168. That is, enter http://192.168.1.168/
in the browser to access the web page. The user name and password are admin by default.
When using the device for the first time, please configure the IP address of the device with your network.

5
The username and the password are admin by default.
Note
To ensure information security, it is recommended to change your password immediately after logging in for the first
time!
Due to the browser compatibility issues, it is recommended to use Chrome or Edge.
Note
To login with the default address, make sure that the computer is configured under the same network segment
(192.168.1.*, * refers to numbers between 1-255 except 168)!
After changing the device IP address, please restore your computer network to the working network IP address.
If MG300 v2 is connected to the network by Ethernet port 2, the default IP address is: 192.168.2.168!
For more information about the MG300 v2 configurations, please refer to:
https://www.kiloview.com/en/support/docs/mg300-v2/

6
6 Decoding and output
6.1 Add video source
In the lower left of the "Media", click "Add", and then select the "Source Type" and configure the parameters
in the pop-up dialog box, and click "OK" to add the video source to the list.
Note
The IP address of video source can be tested with a player such as VLC.
If video source is from network, it is required to configured with a high buffer time for playback buffer until the video
decoding output is smooth.
For more information about how to add the video source, please refer to:
https://www.kiloview.com/en/support/docs/mg300-v2/

7
6.2 Preview
The added sources will be displayed in the “Video Source”, drag the source to the upper “Source
Preview”window to preview the source images and to configure the output parameters.
Note
It is recommended to use the latest version of Chrome and Edge for preview function.
Preview in browser does not support video sources with B-frame and H.265.
To preview, please use the service network IP address to login to the device.
The “Source Preview” window is under "Image" mode by default, and the image refreshes every 3 seconds; if the CPU
performance of your computer is well, you can click and switch to "Video" mode, and there will be smooth video.

8
6.3 Output
There are two output windows on the webpage of MG300 v2. You can select SDI or HDMI to decode and
output the same or different content in the upper right corner of the window. Drag the video source into
the output window, that is, output with the selected SDI or HDMI interface.
Note
The output resolution should be the resolution and frame rate that the receiving monitor can support.
The audio is turned off by default, and it can be turned on by click the red speaker in the lower left corner of the output
window.
Multi-screen output needs to be configured by adding a layout, and supports up to 9 grids output.
For more info about MG300 v2 output layout configurations, please refer to:
https://www.kiloview.com/en/support/docs/mg300-v2/

9
7 Streaming Service
Login to the MG300 v2 webpage, click “Stream Service”>“Add Publishing Points” to add a publishing point,
and select the video source that needs to be forwarded.
1) Click “Source” and select the video source in the source list on the right, then the border of the selected
video source will turn to red.
2) Click “Service”> “Add Stream Service”, and then choose “Service Type”.

10
8 Firmware Upgrading
8.1 Download firmware
8.2 Upgrade firmware
Login to the web page of MG300 v2, click "Settings">"Firmware Upgrade" to check if there is any latest
firmware available to download. If yes, select the downloaded firmware and click “Firmware Upgrade”.
After uploaded the firmware successfully, it needs to reboot the device. After clicking “ok”, the device will
restart, please be patient.
For more information about the MG300 v2 streaming service, please refer to:
https://www.kiloview.com/en/support/docs/mg300-v2/
Kiloview will provide the firmware of updating functions and fixed bugs, please refer
to:
https://www.kiloview.com/en/support/download/
Select “video decoders” > “MG300 v2”, find and download the latest firmware
Note
MG300 v2 and MG300 and RMG-300 v2 are different versions, and their upgrade firmware are different. Please
download the correct firmware of MG300 v2 at Kiloview website before upgrading.

11
9 Restore to factory settings
If the device cannot work normally after modified the parameters or forgot internet IP configuration and
couldn’t search and find the device, please restore factory settings.
Two methods for restoring factory settings:
1) If you can login to web page, click "Settings>System settings>Restore factory settings".
2) If you can’t login to web page, press the RESET button for 5 seconds in the bottom of device.
10 Others
To prolong the device life,please unplug the power and keep it properly if you do not use it for a long
time.
Please not power off during the upgrade process, otherwise the device couldn’t work.
Generally, this process can take 3-5 minutes to upgrade the device. If it’s still not completed after 5 minutes, please try
refreshing webpage. If you still can’t access it, please try to contact technical support.
Note: After restoring to factory setting, below parameters will be turned to default value:
Login username and password will be “admin”.
IP address will be restored to 192.168.1.168, subnet mask will be 255.255.255.0.
All decoding parameters of video and audio will be restored to default value.

12
Any In,Any Out,Anywhere
For more questions, please contact us via:
https://www.kiloview.com/en/support
KILOVIEW Electronics CO., LTD.
Tel:86-18573192787 Email:support@kiloview.com Web:www.kiloview.com/en
Address: B4-106/109, Jiahua Intelligence Valley Industrial Park, 877 Huijin Road, Yuhua District,
Changsha City, Hunan Province, China.
Other manuals for MG300
2
Table of contents
Other Kiloview Gateway manuals
Popular Gateway manuals by other brands

Pathway connectivity solutions
Pathway connectivity solutions Pathport OCT user guide

NetComm
NetComm NF20MESH Getting started

Dialogic
Dialogic 3000 Series quick start guide

MARCOM
MARCOM GW-DLMS-232-LG user manual

Siemens
Siemens SIMATIC PN/J1939 LINK operating instructions

Coretec
Coretec Master IPS Nutrunner Series Operation manual