Kimball Alterna User manual

Alterna™
1
Proper product installation, in accordance with these instructions, is the responsibility of the installing agent.
If you have any questions concerning these instructions, please call Kimball ustomer are.
Part No. 3073966 Revision -
Assembly Instructions
Keyless Lock
There are several locking options for the keyless lock:
• Supervisor Code - Allows the lock to be overridden and to
change operational modes.
Default Code is 071856. It is highly recommended that the
supervisor code e changed
To Lock - Dial the supervisor code and press the lock button
To Unlock - Dial the supervisor code and press the unlock button
• User Code (Non Single Use Mode) Code Doesn t change and
typically is used by single person only.
Default Code is 0000
To Lock - Dial the User code and press the lock button
To Unlock - Dial the User code and press the unlock button
• User Code (Single Use Mode) Code allows for a revolving user
code so the lock can be used by multiple people for shared or day
use lockers or cabinets.
To Lock - Dial a 4 to 8 digit code and press the lock button
To Unlock - Redial the previous 4 to 8 digit code and press the
unlock button.
• Self Lock Mode - Allows the receiver latch to automatically
re-lock 10 seconds after unlocking.
LO K BUTTON
UNLO K BUTTON

Alterna™
2
Proper product installation, in accordance with these instructions, is the responsibility of the installing agent.
If you have any questions concerning these instructions, please call Kimball ustomer are.
Part No. 3073966 Revision -
Assembly Instructions
Keyless Lock Programming
Tools Required
• Pencil
• Paper lip
Figure A
Figure B
Figure C
Supervisor Code
• Press and hold the receiver learn button until the yellow
LED begins a two link pattern… then release.
(Figure A).
• Enter the current supervisor code and press the unlock
button. Wait for the green transmitter light to go out.
(Figure B).
Default supervisor code is 071856.
• Enter the new four to eight digit supervisor code and
press the lock button. Wait for green transmitter light to
go out. (Figure C).
• To confirm, re-enter the new supervisor code & press
lock button.
• If successful, the green LED on the Receiver Latch will
light and learn mode will be exited. (Figure D).
• Test new supervisor code efore locking ca inet.
Make sure to record new supervisor code in a safe
place.
Figure D
LEARN
BUTTON
LED
TRANSMITTER
LIGHT
TRANSMITTER
LIGHT
LED

Alterna™
3
Proper product installation, in accordance with these instructions, is the responsibility of the installing agent.
If you have any questions concerning these instructions, please call Kimball ustomer are.
Part No. 3073966 Revision -
Assembly Instructions
Keyless Lock Programming
Tools Required
• Pencil
• Paper lip
Figure A
Figure B
Figure C
LEARN
BUTTON
LED
TRANSMITTER
LIGHT
Figure D
TRANSMITTER
LIGHT
LED
User Code (Non Single Use Mode)
• Press and hold the receiver learn button until the yellow
LED begins a one link pattern… then release.
(Figure A).
• Enter the current User code and press the unlock button.
Wait for the green transmitter light to go out. (Figure B).
Default user code is 0000.
• Enter the new four to eight digit user code and press the
lock button. Wait for green transmitter light to go out.
(Figure C).
• To confirm, re-enter the new user code & press lock but-
ton.
• If successful, the green LED on the Receiver Latch will
light and learn mode will be exited. (Figure D).
• Test new user code efore locking ca inet. Make sure
to record new user code in a safe place.

Alterna™
4
Proper product installation, in accordance with these instructions, is the responsibility of the installing agent.
If you have any questions concerning these instructions, please call Kimball ustomer are.
Part No. 3073966 Revision -
Assembly Instructions
Keyless Lock Programming
Tools Required
• Pencil
• Paper lip
Figure A
Figure B
Figure C
LEARN
BUTTON
LED
Figure D
User Code (Single Use Mode)
• Press and hold the receiver learn button until the yellow
LED begins a Three link pattern… then release.
(Figure A).
• Enter the current Supervisor code and press the unlock
button. Wait for the green transmitter light to go out.
(Figure B).
Default supervisor code is 071856.
• Enter 1111 and press the lock button, If successful, the
green LED will flash twice on the Receiver Latch and the
green transmitter light will go out. (Figure C).
Note: To convert back to non single use mode enter 1111
and press the unlock button.
• Enter 9999 followed by the lock button to exit program-
ming. Wait for the green transmitter light to go out.
(Figure D).
• Test the new single use mode efore locking the ca i-
net.
LEARN
BUTTON
LED
TRANSMITTER
LIGHT
TRANSMITTER
LIGHT LED
TRANSMITTER
LIGHT

Alterna™
5
Proper product installation, in accordance with these instructions, is the responsibility of the installing agent.
If you have any questions concerning these instructions, please call Kimball ustomer are.
Part No. 3073966 Revision -
Assembly Instructions
Keyless Lock Programming
Tools Required
• Pencil
• Paper lip
Figure A
Figure B
Figure C
LEARN
BUTTON
LED
Figure D
Self-Lock Mode
• Press and hold the receiver learn button until the yellow
LED begins a Three link pattern… then release.
(Figure A).
• Enter the current Supervisor code and press the unlock
button. Wait for the green transmitter light to go out.
(Figure B).
Default supervisor code is 071856.
• Enter 2222 and press the lock button, If successful, the
green LED will flash twice on the Receiver Latch and the
green transmitter light will go out. (Figure C).
Note: To convert back to passage mode enter 2222 and
press the unlock button.
• Enter 9999 followed by the lock button to exit program-
ming. Wait for the green transmitter light to go out.
(Figure D).
• Test the new Self-Lock Mode.
LEARN
BUTTON
LED
TRANSMITTER
LIGHT
TRANSMITTER
LIGHT LED
TRANSMITTER
LIGHT
Table of contents