King Pigeon K5S User manual

PSTN Alert To
Ethernet/Wireless Alert!
Compatible With Most Of The
PSTN Security Control Panel.
Special Designed For Your
Existing PSTN Alarms
Systems!
GSM/3G/4G LTE Communicator
PSTN SIA DC-05 Protocol to SIA DC-09 Protocol & SMS Alert
User Manual
Ver 1.3
Model: K5S
Date Issued: 2018-12-20
All rights reserved by King Pigeon
Communication. Co., Ltd.
www.GsmAlarmSystem.com

Page 2of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
Table of Contents
1.The Introduction.......................................................................................................................................................3
2. The Specifications..................................................................................................................................................3
3. The Features............................................................................................................................................................ 3
4. The Standard Package.......................................................................................................................................... 4
5. The Overview of Main Panel................................................................................................................................ 4
6. The Indicator Lights............................................................................................................................................... 4
7. The Connection....................................................................................................................................................... 5
8. The Installations......................................................................................................................................................5
8.1 Install the USB Driver on PC........................................................................................................................ 5
8.2. Install the USB Driver on PC....................................................................................................................... 5
8.3. Settings in PC Configurator......................................................................................................................... 6
8.3.1 The Menu Bar of the PC configurator.........................................................................................................6
8.3.2 GPRS data Parameter Setting...................................................................................................................7
8.3.3 The Phone Numbers for Events Notification...............................................................................................7
8.3.4 Set the Password and PIN Code Verification..............................................................................................8
8.3.6 Set the CMS Server IP address and Server Port........................................................................................8
8.3.7 Set the Output pulse time and Ethernet parameter.....................................................................................9
8.3.8 The other buttons in PC configurator..........................................................................................................9
8.3.9 Set the SMS Notification Contents...........................................................................................................10
8.4.0 Engineer Debug for GPRS Data Transmission.........................................................................................11
9. The SMS Commands........................................................................................................................................... 11
10. Warranty................................................................................................................................................................13
【UPDATE HISTORY】
Date
CONFIGURATOR VERSION
FIRMWARE VERSION
HARDWARE VERSION
DESCTIPTION
2017.08
V1.1
The first version
2018.12
V1.2
Dec 7 2018
K5S B2
Add “Event Code” setting
Safe Startup
Do not use the unit when using GSM/3G/4G equipment is prohibited or might bring disturbance or danger.
Interference
All wireless equipment might interfere network signals of the unit and influence its performance.
This handbook has been designed as a guide to the installation and operation of GSM Communicator.
Statements contained in the handbook are general guidelines only and in no way are designed to supersede the
instructions contained with other products. We recommend that the advice of a registered electrician be sought before
any Installation work commences.
King Pigeon Communication Co., Ltd, its employees and distributors, accept no liability for any loss or damage
including consequential damage due to reliance on any material contained in this handbook.
King Pigeon Communication Co., Ltd, its employees and distributors, accept no liability for GSM Network upgrading or
SIM Card upgrading due to the technology specifications contained in this handbook.

Page 3of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
1. The Introduction
The GSM/3G/4G Communicator K5S is specially designed for your existing alarm systems. It’s compatible
with the majority of Security Manufacturers' Control Panels.
The GSM/3G/4G Communicator K5S can transfer the Alert Message from your PSTN Contact ID (SIA
DC-05) Control panel into SIA DC-09 protocol over Ethernet/GPRS network and SMS notification. It could
change the way of alert notification from traditional PSTN alert to Ethernet/wireless alert (SIA standard
DC-09 requirements).
Notice:
The ‘K5S’ will be written in the following contents below instead of ‘GSM/3G/4G LTE Communicator K5S’.
2. The Specifications
Signal Frequency
GSM850 / 900 / 1800 / 1900 MHz (3G/4G module
optional) ; For example: Customer only need to replace
the module for upgrading K5S from 3G to 4G
Communication Ways
Ethernet & TCP/IP via GPRS
Message Transmission Protocols
SIA DC-09-2007 or SIA DC-09-2012 (K5S)
SIA DC-05 (PSTN Control Panel)
Outputs
OUT1, OUT2 ,OC type, communicates voltage of up to
30 V and direct current of up to 1 A
Configuration
via USB port or SMS commands
Power Supply
DC 9V ---24 V
Used Current
10 ---30 mA (on standby),
up to 70 mA (while sending data)
Workplace
Temperature from -10C to +50C,
Relative humidity up to 80 % when +20 C
Backup battery
900mAH
Exterior dimension
105 mm * 88 mm * 30 mm (W*D*H)
3. The Features
Easy programmed by PC configuration, compatible with most Control Panels,
Support modular system, upgrade 3G/4G only need to replace the module.
Supports transferring data by PSTN Ethernet or GPRS, SMS ( no phone call ),
Supports 2 different CMS centers (IP addresses or DNS server).
SMS notification when the connection with the CMS center is failed (3 trial times).
When PSTN network failed, it will send the alert message to the center by Ethernet/GPRS network,
When the PSTN network good, then it will not use GPRS network etc. for transferring alert message,
5 users to receive SMS notification on Alarm, Supervision, Trouble, By pass, Test, GPRS fail, DC loss,
SMS commands to check the device version, IMEI code, GSM signal,
2 OC outputs which could be controlled by SMS commands, output pulse time can be set.
Support firmware upgrading via USB.
Supports PIN code verification in PC configurator.
Remote configuration by SMS commands.

Page 4of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
Backup rechargeable battery, with DC power failure SMS alert.
4. The Standard Package
Main Panel x 1,
Antenna x 1,
AC/DC adaptor(12V/1A) X 1,
USB cable x 1,
CD (User Manual & PC Configurator) x 1.
5. The Overview of Main Panel
T1: Connect with the ‘TLP’ in PSTN control panel
R1: Connect with the ‘RING’ in PSTN control panel
T2: Connect with the Land Line
R2: Connect with the Land Line
(Notice: No connection means the control panel will transmit the message only via GPRS.)
OUT1: 1st Outputs, OC type.
COM: General terminal.
OUT2: 2nd Outputs, OC type.
6. The Indicator Lights
[RED]: GMS Indicator, blinking every 0.5s means registering the network, when the GSM
signal is normal, it will keep blinking every 1s.
GSM Antenna
GSM Signal
Power Signal
GPRS Signal
USB Port for PC Configurator.
Power Supply
Ethernet Port
Ethernet

Page 5of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
[RED]: Power Supply Indicator, blinking every 1s means the battery is on charge, the ON
means the battery is in full charge, OFF means Disconnection with the external power
adapter.
[RED]: GPRS Data Indicator, it will keep blinking every 1s when K5S is transferring GPRS
data.
[RED]: Ethernet indicator, it will keep blinking when K5S is transferring GPRS data; Keep ON
means Ethernet connect to the server successfully.
7. The Connection
8. The Installations
Notice:
There are 2 ways for settings: PC configuration & SMS commands. Please install the USB Driver before using the PC
confirgurator.
8.1 Install the USB Driver on PC.
1) Screw the GSM antenna,
2) Open the cover on the back the K5S to find the SIM card holder, and insert the SIM card as below:
3) Turn on the power supply and switch K5S on, and check the GSM Signal Indicator light to confirm the
SIM card in K5S is working well. please check the indicator lights details in 【6. The Indicator Lights】.
8.2. Install the USB Driver on PC.
1) Click HERE to download and install the latest USB Driver according to your PC operation system.
2) Connect the K5S to the Computer via USB cable,
3) Find the USB Serial Port as picture below. (This COM port number will be used in PC configurator).
Firmware
Upgrading
Button
Switch

Page 6of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
8.3. Settings in PC Configurator
Choose the USB Serial Port according to 【8.2. Install the USB Driver on PC.】, and click open Com , it
will come to the Basic Information window as below:
Notice:
When the settings in current window is done, please click Save Settings to complete the configuration.
8.3.1 The Menu Bar of the PC configurator

Page 7of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
Loading Profile
[Alt + L]: Load the setting profile that you have saved before
Save the Profile
[Alt + S]: Save the settings to the local
Recovery Factory Default
[Alt + R]: Reset the K5S device back to the factory
About
[Alt + A]: The information about the K5S
Exit
[Alt + E]: Exit the PC configurator.
8.3.2 GPRS data Parameter Setting
Notice:
The example provided by Orange UK above is only for reference, please contact your local GSM operator for the settings
accordingly. If the local GSM Operator does not use APN anymore, please ignore the settings in this part.
8.3.3 The Phone Numbers for Events Notification
Tel No. 1 – No. 5
The phone numbers for the SMS notification.
Alarm
Ademco®Contact ID Protocol Events Codes.
Supervision
Trouble
Open
ByPass
Test
GPRS Fail
The GPRS message transmission failure notification from K5S .
The external DC Power Loss notification from K5S
DC Loss
Notice:
1) Tick it stands for the phone numbers in the list will receive the SMS notification when the event occurred.
2) Only for SMS notification, no voice communication.
3) 18676734714 is the phone number only for example. If the K5S can’t work, please add your country code in front of
the phone number.
everywhere
esecure
secure
For Example:

Page 8of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
8.3.4 Set the Password and PIN Code Verification
8.3.5 Set the OC Outputs Names
Notice:
The max characters for the Output Name is 40, these names will be displayed in the SMS notifications.
8.3.6 Set the CMS Server IP address and Server Port
The name of the 1st Output, default: DO1
The name of the 2nd Output, default: DO2
Alarm Host PSTN Protocol: SIA DC-05.
GPRS Protocol: SIA DC-09-2007/2012.
Notice:
The alert messages will be transmitted to
Sever 2 (backup) once Server 1 failed
after both of them are set.
Notice:
The ‘’K5 Password’’ is the password for the setting
of
【
9. The SMS Commands.
】
.
The "Account number."can set to replace the PSTN
panel account when upload via GPRS.

Page 9of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
8.3.7 Set the Output pulse time and Ethernet parameter
Output Pulse Time
0~9999S
Ethernet Parameter
Default "0",means getting IP and DNS automatically
GPRS Module
(optional)
a.1)With GPRS module, if not connect the Ethernet, device will send SMS: "
Ethernet connection failed, please check the wired network!"
2) With GPRS module, if the Ethernet connect the server failed or server not
response, will SMS" ETH Connect Failure"
At this time, the alert will transfer the data via GPRS; But if Ethernet connect
successfully and server response well, then not transfer the data via GPRS.
b. Without GPRS module, only transfer data via Ethernet.
8.3.8 The other buttons in PC configurator
open Com
Open the USB serial Com Port.
Close Com
When it displayed, it means successful connection.
Read Versiona Info
Read the device model, IMEI Code, Version.
Read settings
Read the existed setting data in the K5S.
Save Settings
Click this button to complete the current settings.
Delete Settings
Delete all the setting data in K5S.
Clear Display
Clear the words displayed in the current windows (The existed settings will not be
cleared).
Clear Received Data
Clear the data K5S have received in the current window.

Page 10 of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
Clear Sent Data
Clear the data K5S have send in the current window.
Stop Debug
Stop the debug.
Notice:
There are three different windows in PC configurator: Basic Information ,SMS Message ,GPRS Debug .Please click the
Save Settings when the setting data in the current windows is completed.
8.3.9 Set the SMS Notification Contents
Event Code
Set it according to PSTN control panel,3 digits
Partition
Set it according to PSTN control panel,2 digits
Zone (64 zones)
Set it according to PSTN control panel,3 digits
SMS Text Message
(Max 59 characters)
SMS alert content when the zone in the PSTN control panel is triggered.
Notice:
1.Please reference Contact CID protocol when you configure.
2.SMS notification content will show event qualifier;
3.When above parameters are set to be consistent with PSTN control panel, the device will send the
correct alarm message according to the SMS Notification Contents that user sets.
4.If event code isn’t set correctly,the alert SMS K5S sends will be according to the event alarm information
in the Contact CID protocol.

Page 11 of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
8.4.0 Engineer Debug for GPRS Data Transmission
9. The SMS Commands
The SMS commands below are send to the SIM card of K5S for remote configuration, and the SMS
commands are only used when you are not able to program the K5S by the PC configurator.
Notice:
1) All the letters in SMS commands must be CAPITALIZED under the English format.
2) The Examples below are only for reference, please send the SMS commands according to your actual situations.
3) The Password below is the default password (1234), please use the new password in the SMS commands when the
default password was changed.
1)When the wrong SMS commands was send:
SMS Commands
Return SMS Message
SMS Format Error, Please check Caps Lock in Command!
Notice:
If any SMS command with the wrong format was send, you will receive a SMS notification as above.
2)When the external DC Power loss/Recovery
Return SMS Message
DC Loss
External DC Power Goes OFF
DC Recovery
External DC Power Goes ON
3)Change the password (The default password is 1234, with 4 digits):

Page 12 of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
SMS Commands
Return SMS Message
Old Password+P+New Password
【New Password】,This is the New Password, please remember it carefully.
For Examples: 1234P4321
【4321】,This is the New Password, please remember it carefully.
Notice:
When the password was forgot, please reset the device from the PC configurator.
4)Inquiry the device information remotely
SMS Commands
Return SMS Message
Password+EE
Model:
Version:
IMEI:
GSM Signal Value:
For Examples: 1234EE
Model: K5S
Version: V 1.00 2015-12
IMEI: 867965029050313
GSM Signal Value: 30
Notice:
1) Every K5S has a unique IMEI code for firmware upgrading.
2) The GSM Signal Value range: 1~31.99, Signal weak value: <16.
5)Program the 5 mobile phone numbers (the max is 23 digits) for SMS notification.
Actions
SMS Commands
Return SMS Message
Set Mobile Phone Numbers
Password+A+Serial Number +T+ Phone Number
For Example: 1234A3T13570810254
Tel1: ---
Tel2: ---
Tel3: 13570810254
Tel4: ---
Tel5: ---
Inquiry the whole numbers list
Password +A
For Example: 1234A
The list of the exiting numbers
Delete the phone number in the
existing numbers list
Password+A+Serial Number
For Example: 1234A3
The list of the exiting numbers
Notice:
1) The Serial Number: 1 ~ 5.
2) These mobile phone numbers are ONLY used for the SMS notification, no voice notification.
3) It makes no difference for adding country code or not in front of the mobile phone numbers.
6)Program the OC Outputs
Actions
SMS Comands
Return SMS Message
Set the name of the OC outputs
Password+DO+Serial Number+T+the name
For example: 1234DO1TOutput 1 for Arm.
DO1: rename: xxxx
Example: DO1: rename: Output
1 for Arm.
Inquiry the name of the OC
outputs
Password+DO+Serial Number
For example: 1234DO1
DO1: Output 1 for Arm
Delete the name of the OC outputs
Password+DO+Serial Number+DEL
For example: 1234DO1DEL
DO1: Output 1 for Arm
Switch the relay on
Password+DOC+Serial Number
DO1: ON

Page 13 of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
For example: 1234DOC12
It means switch on both the 1st output and 2nd output
(The serial number is 1 or 2 or both)
DO2:ON
Switch the relay off
Password+DOO+Serial Number
For example: 1234DOO12
It means switch off both the 1st output and 2nd output
Or both. (The serial number is 1 or 2 or both)
DO1: OFF
DO2:OFF
Inquiry all the current status
Password+DOE
For example: 1234DOE
DO1: ON/OFF
DO2:ON/OFF
---
Pulse output time
Password+DOP+Serial Number (1 or 2) +T
Time(Max 4 digits,9999s)
Default: 0s ,means always keep close
DO(1 or 2) Pulse Output Time:
xxxS
Inquiry output time
Password+DOT+Serial Number (1 or 2)
DO(1 or 2) Pulse Output Time:
xxxS
Pulse output control
Password+DOP+Serial Number
(The serial number is 1 or 2 or both)
Notice:
1. The Serial Number: 1means the 1st output, 2means the 2nd output, 12 means both the 1st output and the 2nd output.
2. The name of the outputs is 40 characters (Max.)
7)Program the GPRS IP Sever and the Port:
Actions
SMS Commands
Return SMS Message
Settings
Password+IP+ IP address +P+Port Number
For example: 1234IP183.12.162.70P4005
Server:
Port:
Inquiry the settings
Password +IP
For example: 1234IP
Delete the exiting setting
Password+IP+DEL
For example: 1234IPDEL
Notice:
Only the 1st server IP could be programmed via SMS commands, and please program the 2nd server IP via PC configurator.
More details please visit:
【
8.3.6 Set the CMS Server IP address and Server Port.
】
8)GPRS data Parameter Setting(APN/USER NAME/PASSWORD)
Actions
SMS Commands
Return SMS Message
Settings
Password+AP+APN;User Name;Password#
For example: 1234APeverywhere;esecure;secure#
APN:
User Name:
Password:
Inquiry the settings
Password+AP
For example: 1234AP
Delete the exiting setting
Password+APDEL
For example: 1234APDEL
10. Warranty
1) This system is warranted to be free of defects in material and workmanship for one year.
2) This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the

Page 14 of 14 King Pigeon Communication Co., Ltd. Ver 1.2 Date: 20181220
GSM/3G/4G LTE Communicator
PSTN _Alert_to_Ethernet/Wireless _Alert_Converter
Operating Instructions. In no event shall the manufacturer be liable for any alarm system altered by
purchasers.
The End!
King Pigeon Communication Co., Ltd.
Professional GSM/3G/WIFI Security Alarms Manufacturer and M2M Solution Provider since 2005.
www.GsmAlarmSystem.com
www.GPRS-M2M.com
Table of contents