Kleenmaid Automatic dryers User manual

D311IE3A
Part No. 504062R2
September 1998
Installation Instructions
for Automatic Dryers
BY , USA.
yuiop
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. (If the dryer changes ownership, be sure
this manual accompanies the dryer.)
NOTE: The electrical installation in the site shall comply with the latest edition of the Australian Electrical
Standards AS3000 - SAA wiring rules and such local regulations that might apply.
The gas dryer installation must conform with the local regulations and AG601, Installation Code for Gas
Burning Appliances.
Read complete Installation and Operation Instructions before using dryer.
The maximum drying load (dry weight) shall not exceed 9 kg (20 pounds).


504062 1
Table of
Contents
Replacement Parts ..................................................................................... 2
Roughing In Dimensions ........................................................................... 3
Before You Start
Tools ..................................................................................................... 4
Exhaust .................................................................................................. 4
Electrical................................................................................................ 4
Gas......................................................................................................... 4
Location................................................................................................. 4
Installing the Dryer
STEP 1 (Position and Level the Dryer) ................................................ 5
STEP 2 (Connect Dryer Exhaust System)............................................. 5
STEP 3 (Connect Gas Supply Pipe)...................................................... 6
STEP 4 (Wipe Out Inside of Dryer)...................................................... 7
STEP 5 (Plug in the Dryer) ...................................................................7
STEP 6 (Check Installation).................................................................. 7
Heat Check ................................................................................................. 8
Burner Flame ............................................................................................. 8
Reversing Door Procedure ........................................................................ 9
Manufactured (Mobile) Home Installation ........................................... 10
Electrical Requirements (Electric Dryers) ............................................ 11
Electrical Requirements (Gas Dryers) .................................................. 12
Gas Service ...............................................................................................13
Location Requirements .......................................................................... 15
Dryer Exhaust Requirements
Exhaust System Materials ................................................................... 16
Make Up Air Requirements................................................................. 16
Exhaust System ...................................................................................17
Exhaust Direction................................................................................ 17
Exhaust System Maintenance..............................................................18
Dryer Airflow ...................................................................................... 18
Reduced Clearance Elbow................................................................... 18
User-Maintenance Instructions
Lubrication .......................................................................................... 19
Care of Your Dryer..............................................................................19
Exhaust System ...................................................................................19
Wiring Diagram (Electric Dryers).......................................................... 20
Wiring Diagram (Gas Dryers) ................................................................ 21
Information for Handy Reference .......................................................... 22
Installer Check .......................................................................... Back Cover
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury or death. W033
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use any phone in your building.
– Clear the room, building or area of all occupants.
– Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
– If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas
supplier. W052
WARNING
© Copyright 1998, Alliance Laundry Systems LLC
All rights reserved. No part of the contents of this book may be reproducedor transmitted in any form or by anymeans without
the expressed written consent of the publisher.

2504062
Replacement Parts . . .
If replacement parts are required, contact the source
where you purchased your dryer.

504062 3
Roughing In Dimensions . . .
ELECTRIC DRYERS
7.7"
(19.6 cm)
4.0"
(10.2 cm)
23.5"
(59.7 cm) 28"
(71.1 cm)
.4"
(1.1 cm) 26.9"
(68.3 cm)
4.0"
(10.2 cm)
15.4"
(39.1 cm)
*36" (91.4 cm)
*43" (109.2 cm)
* WITH LEVELING LEGS TURNED INTO BASE D312IE3D
GAS DRYERS
7.7"
(19.6 cm)
4.0"
(10.2 cm)
23.5"
(59.7 cm) 28"
(71.1 cm)
.4"
(1.1 cm)
4.0"
(10.2 cm)
15.4"
(39.1 cm)
*36" (91.4 cm)
*43" (109.2 cm)
* WITH LEVELING LEGS TURNED INTO BASE D313IE3C
26.9"
(68.3 cm)
2.8"
(7 cm)
2.3" (6 cm)
3/8" NPT
GAS CONNECTION

4504062
Before You Start . . .
Tools
For most installations, the basic tools you will need are:
Exhaust
Use rigid metal duct and exhaust the dryer to the
outside by the shortest route possible.
NOTE: For more detailed information, refer to
Section on Dryer Exhaust Requirements.
Electrical
•ELECTRIC DRYER
Dryer needs a 2 wire plus earth, 250 Volt, 50 Hertz,
single phase electrical supply.
•GAS DRYER
Dryer needs a 2 wire plus earth,250 Volt, 50 Hertz,
single phase electrical supply.
NOTE: For more detailed information, refer to
Section on Electrical Requirements.
Gas
Dryer is equipped for Natural Gas with a 3/8" NPT gas
supply connection. For more detailed information,
refer to Section on Gas Requirements.
Location
Place the dryer on a solid floor with an adequate air
supply. For more detailed information, refer to Section
on Location Requirements.
D074IE1F
DUCT TAPE TEFLON TAPE
WRENCH
LEVEL
SCREWDRIVERS
D314IE0A

504062 5
Installing the Dryer . . .
Step 1:
Position and Level
the Dryer
For further assistance refer to Section on Location
Requirements.
Install dryer before washer. This allows room for
attaching exhaust duct.
Place the dryer in position, and adjust the legs until the
dryer is level.
Step 2:
Connect Dryer Exhaust System
For further assistance refer to Sections on Location
Requirements and Dryer Exhaust Requirements.
• DO NOT use plastic or thin foil flexible ducting.
• Locate dryer so exhaust duct is as short as possible.
• Be certain old ducts are cleaned before installing
your new dryer.
• Use 4" (10.2 cm) diameter rigid or flexible metal
duct.
• Use as few elbows as possible.
• Use duct tape on all joints.
• Failure to exhaust dryer properly will void
warranty.
NOTE: Venting materials are not supplied with the
dryer (obtain locally).
D298IE1A
DRYER
BASE
LEVELING
LEG
LEVEL
D259I
A clothes dryer produces combustible lint.
To reduce the risk of fire and combustion
gas accumulation the dryer MUST be
exhausted to the outdoors. W116
WARNING
DOD314IE0C DON'T
D315IE0C

6504062
Step 3: (Gas Dryer ONLY)
Connect Gas Supply Pipe
For further assistance, refer to Section on Gas Requirements.
1. Make certain your dryer is equipped for use with
the type of gas in your laundry room. Dryer is
equipped at the factory for Natural Gas with a 3/8"
NPT gas connection.
2. Remove the shipping cap from the gas connection
at the rear of the dryer. Make sure you do not
damage the pipe threads when removing the cap.
3. Connect to gas supply pipe.
4. Tighten all connections securely. Turn on gas and
check all pipe connections (internal & external) for
gas leaks with a non-corrosive leak detection fluid.
5. For L.P. (propane) gas connection, refer to Section
on Gas Requirements.
3/8" NPT
GAS CONNECTION
PRESSURE
TEST
POINT
NEW
STAINLESS
STEEL
FLEXIBLE
CONNECTOR
USE ONLY
IF ALLOWED
BY LOCAL
CODES
(Use
Design AGA
Certified
Connector)
SHUT-OFF
VALVE
D246IE3B

504062 7
Step 4:
Wipe Out Inside Of Dryer
Before using dryer for the first time, use an all-purpose
cleaner, or a detergent and water solution, and a damp
cloth to remove shipping dust from inside dryer drum.
Step 5:
Plug in the Dryer
Refer to Section on Electrical Requirements, and
connect the dryer to an electrical power source.
Step 6:
Check Installation
Refer to Installer Check on the back cover of this
manual and make sure that dryer is installed correctly.
D327IE2A
D197IE0A
ELECTRIC
Connect to 20 Amp circuit.
50 Hz
250 V
D198IE0A
250 V
10A
GAS
Plug cord into separately fused
10 Amp circuit.

8504062
Heat Check . . .
(Electric Dryers)
Close the loading door and start the dryer in a heat
setting (refer to the Operating Instructions supplied
with the dryer). After the dryer has operated for three
minutes, the exhaust air or exhaust pipe should be
warm.
Burner Flame . . .
(Gas Dryers)
IMPORTANT: This operation to be conducted by qualified personnel only.
To view the burner flame, remove the lower front panel
of the dryer.
Close the loading door, start the dryer in a heat setting
(refer to the Operating Instructions supplied with the
dryer); the dryer will start, the igniter will glow red and
the main burner will ignite.
IMPORTANT: If ignitor is not lit, make sure gas is
turned on.
IMPORTANT: If all air is not purged out of gas
line, gas igniter may go off before gas is ignited. If
this happens, after approximately one minute,
igniter will again attempt gas ignition. If ignition
does not occur after the fourth ignition attempt, the
control will lock out and red light will flash (see
figure at right). If lockout occurs, open loading
door for one minute to reset control. When control
is properly reset, flashing will stop.
After the dryer has operated for approximately five
minutes, observe burner flame through lower front
panel. Adjust the air shutter to obtain a soft, uniform
blue flame. (A lazy, yellow-tipped flame indicates lack
of air. A harsh, roaring, very blue flame indicates too
much air.) Adjust the air shutter as follows:
a. Loosen the air shutter lockscrew.
b. Turn the air shutter to the left to get a luminous
yellow-tipped flame, then turn it back slowly to the
right to obtain a steady, soft blue flame.
c. After the air shutter is adjusted for proper flame,
tighten the air shutter lockscrew securely.
d. Reinstall the lower front panel.
After the dryer has operated for approximately three
minutes, exhaust air or exhaust pipe should be warm.
To reduce the risk of serious injury or death,
the lower front panel must be in place
during normal operation. W158
WARNING
WR WHITE - ROGERS DIV.
EMERSON ELECTRIC CO.
DISCONNECT POWER
BEFORE SERVICING
DISCONNECT POWER
BEFORE SERVICING
DISCONNECT POWER
BEFORE SERVICING
DISCONNECT POWER
BEFORE SERVICING
DISCONNECT POWER
BEFORE SERVICING
DISCONNECT POWER
BEFORE SERVICING
DISCONNECT POWER
BEFORE SERVICING
DISCONNECT POWER BEFORE
SERVICINGGDGHDHJD DHJD DHD HD
HD HDHDGFJGFKGK GFJHGJ FHFH
F KJFJF KH GJHJF JDAPALS DK KF
DISCONNECT POWER BEFORE
SERVICING SERVICEING OK
IMPORTANT
DIAGNOSTIC INDICATOR
MODEL 50A72-203.
WARNING
WR
RED
LIGHT D251IE1A

504062 9
Reversing Door Procedure . . .
The door on this dryer is completely reversible. To reverse door proceed as follows:
D271PE1B
1
Remove four
hinge attaching
screws.
D272PE1A
2
Remove all nine screws.
D268PE1A
Pull bottom of
door liner out,
then pull down,
removing door
liner from door
panel.
3
B
AD273PE1C
4
Rotate door panel
180 degrees
as shown.
D276PE1B
5
Remove door strike
from door liner
and reinstall on
opposite side.
D269PE1C
6
Insert liner under
flange on bottom of
door, then push
top of door
liner into place.
B
A
D270PE1B
7
Reinstall nine screws
removed in Step 2.
D274PE1A
8
Using a screwdriver,
remove two door plugs,
and reinstall on
opposite side of
door opening.
D275PE1A
9
Reinstall four hinge
attaching screws
removed in Step 1.

10 504062
Manufactured (Mobile) Home
Installation . . .
The dryer can be installed in a manufactured (mobile)
home by following these instructions:
1. IMPORTANT: Gas dryers MUST be
permanently attached to the floor at the time of
installation.OrderNo.526P3DryerInstallation
Kit for a manufactured (mobile) home
installation. Follow the instructions supplied
with the kit.
2. Venting—Dryer MUST be exhausted to the
outdoors.
• The dryer can be exhausted to the outdoors through
the back, left, right or bottom panel. Gas dryers
cannot be exhausted out the left side because of the
burner housing.
• The dryer exhaust duct must be secured to the
mobile home structure.
• Exhaust ducts MUST NOT be connected with sheet
metal screws or fasteners which extend into the duct.
• Exhaust duct must not be connected to any other
duct, vent or chimney.
• Dryer exhaust duct MUST NOT terminate under the
mobile home.
• For proper operation, it is important that the dryer
has an ample amount of outside make-up air. The
free area of any opening for the introduction of
outside air must be at least 25 in2(163 cm2).
• When exhausting the dryer to the outdoors, the dryer
can be installed with “0” inch clearance at the sides
and rear. Clearance of the duct from combustible
construction must be a minimum of 2 inches (5.08
cm).
• Venting materials are not supplied with the dryer
(obtain locally).
IMPORTANT: Installation must conform to
the Manufactured Home Construction and
Safety Standards, Title 24 CFR, Part 32-80 or
Standard CAN/CSA-Z240 MH.
To reduce the risk of fire and combustion
gas accumulation, the dryer MUST BE
EXHAUSTED TO THE OUTDOORS. Refer to
Section on Dryer Exhaust Requirements.W047
WARNING
To reduce the risk of fire, the exhaust duct
and weather hood MUST be fabricated of a
material that will not support combustion.
Rigid or flexible metal pipe is recommended
for a clothes dryer. W048
WARNING

504062 11
Electrical Requirements . . .
(Electric Dryers)
NOTE: The wiring diagram is located inside the
control hood.
IMPORTANT: The electrical installation in the site
shall comply with the latest edition of Australian
Electrical Standards, AS3000, SAA wiring rules,
and such local regulations that might apply.
This dryer is designed to be operated on a two wire,
plus earth, 240 Volt, 50 Hertz, single phase circuit,
fused at 20 amperes.
Insert the dryer’s lead-in cord plug into an earthing
three-slot-plus earth, wall receptacle on a separate
circuit. DO NOT OPERATE OTHER APPLIANCES
ON THE SAME CIRCUIT WHEN THE DRYER IS
OPERATING.
50 Hz
250 V
LEAD-IN
CORD
EARTH
SCREW
EARTH
D197IE1A
LEAD-IN
CORD PLUG

12 504062
Electrical Requirements . . .
(Gas Dryers)
NOTE: The wiring diagram is located inside the
control hood.
IMPORTANT: The electrical installation in the site
shall comply with the latest edition of Australian
Electrical Standards, AS3000, SAA wiring rules,
and such local regulations that might apply.
This dryer is designed to be operated on a two wire,
plus earth, 240 Volt, 50 Hertz, single phase circuit,
fused at 10 amperes.
Insert the dryer’s lead-in cord plug into an earthing
three-slot wall receptacle on a separate circuit. DO
NOT OPERATE OTHER APPLIANCES ON THE
SAME CIRCUIT WHEN THE DRYER IS
OPERATING.
Earthing Instructions
The dryer must be earthed. In the event of malfunction
or breakdown, earthing will reduce the risk of electric
shockbyproviding a path of least resistance for electric
current. The dryer is equipped with a cord having an
equipment-earthing conductor and a 3-prong earthing
plug. The plug must be plugged into an appropriate
outlet that is properly installed and earthed in
accordance with local codes and ordinances.
Do not modify the plug provided with the dryer—if it
will not fit the outlet, have a proper outlet installed by
a qualified electrician.
If your home’s electrical supply does not meet the
above specifications and/or you are not sure your home
has an effective earth, have a qualified electrician or
your local electrical utility company check it and
correct any problems.
LEAD-IN
CORD
EARTH
SCREW
EARTH
D198IE1A
LEAD-IN
CORD PLUG
250 V
10A
Improper connection of the equipment-
earthing conductor can result in a risk of
electric shock. Check with a qualified
electrician or serviceman if you are in doubt
as to whether the dryer is properly earthed.
W159
WARNING

504062 13
Gas Service . . .
(Gas Dryers)
NOTE:The gas serviceto a gasdryer must conform
with the local codes and ordinances and AG601,
Installation Code for Gas Burning Appliances. In
the absence of local codes and ordinances,
applicable National codes should be followed.
Connection of Gas Supply Pipe
1. Install the dryer with sufficient clearance for
adequate air circulation, and for the ease of the
dryer installation, servicing and operation. For
maximum drying performance, we recommend
you allow more clearance than the clearances that
are listed throughout this manual.
2. Remove the shipping cap from the gas connection
at the rear of the dryer. Make sure you do not
damage the pipe threads when removing the cap.
3. Make certain your dryer is equipped for use with
the type of gas in your laundry room.
NOTE: Natural gas, 1,000 Btu/ft3(37.3 MJ/m3),
service must be supplied at 6.5 ± 1.5 inch (1.6 ± .4
kPa) water column pressure. Do not connect the
dryer to L.P. (propane) gas service without
converting the gas valve. A No. 401P3 L.P.
(propane) Gas Conversion Kit must be installed by
the Manufacturer’s Authorized Dealers,
Distributors, or local service personnel.
NOTE: L.P. (propane) gas, 2,500 Btu/ft3(93.1 MJ/
m3), service must be supplied at 10 ± 1.5 inch (2.5 ±
.4 kPa) water column pressure and a vent to the
outdoors must be provided.
4. If local codes allow the use of flexible gas tubing,
connect the 3/8 inch NPT (National Pipe Thread)
gas connection at the rear of the dryer to the
laundry room’s gas line with new flexible stainless
steel tubing (using design certified Australian Gas
Association connector only).
IMPORTANT: Use local codes of practice for gas
installation.
This dryer is equipped with jet for Natural gas.
Gas Consumption Natural 21.9 MJ
L.P. (propane) 21.9 MJ
Gas Pressure Natural 0.88 kPa
L.P. (propane) 2.75 kPa
To reduce the risk of gas leaks, fire or
explosion:
• The dryer must be connected to the type of
gas as shown on nameplate located in the
door recess.
• Use a new flexible stainless steel
connector.
• Use pipe joint compound insoluble in LP
(propane) Gas, or Teflon tape, on all pipe
threads.
• Purge air and sediment from gas supply
line before connecting it to the dryer.
Before tightening the connection, purge
remaining air from gas line to dryer until
odor of gas is detected. This step is
required to prevent gas valve
contamination.
• Do not use an open flame to check for gas
leaks. Use a non-corrosive leak detection
fluid. W114R1
WARNING
D246IE1C
3/8" NPT
GAS CONNECTION
NEW
STAINLESS
STEEL
FLEXIBLE
CONNECTOR
USE ONLY
IF ALLOWED
BY LOCAL
CODES
(Use
Design AGA
Certified
Connector) SHUT-OFF
VALVE
PRESSURE
TEST
POINT

14 504062
NOTE:Whenconnectinggassupplyline,apressure
test point must be installed downstream from the
shutoff valve for checking inlet gas pressure.
5. The gas line to your laundry room should be made
of black iron pipe. A 3/8 inch (9.5 mm) pipe with
an inside diameter of .46” (11.7 mm) will be
adequate if length of supply line is not over 20 feet
(6 m). If length exceeds this, use 1/2” (12.7 mm)
pipe. If copper semi-rigid tubing is used it must be
internally tinned or equivalently treated to resist
sulfur corrosion.
NOTE: The dryer and its appliance main gas valve
must be disconnected from the gas supply piping
system during any pressure testing of that system at
test pressures in excess of 1/2 psig (3.45 kPa).
The dryer must be isolated from the gas supply piping
system by closing the equipment shutoff valve during
any pressure testing of the gas supply piping system at
test pressure equal to or less than 1/2 psig (3.45 kPa).
6. Check all pipe connections (internal and external)
for gas leaks with a soapy solution. Gas
connections should be checked annually for
leakage.
7. Be sure the shut off valve in your dryer is OPEN.
Your dryer is shipped with the valve open.
8. The dryer gas valve is equipped with a pressuretest
point for checking manifold pressure.
For proper operation at altitudes above 3,000 feet (915
m) the natural gas valve spud orifice size must be
Altitude Orifice Size Part
Number
ft m # Inches mm
3000 915 43 0.0890 2.26 503778
6000 1830 44 0.0860 2.18 58719
8000 2440 45 0.0820 2.08 503779
9000 2740 46 0.0810 2.06 503780
10000 3050 47 0.0785 1.99 503781

504062 15
Location Requirements . . .
Select a location with a solid floor.
No other fuel burning appliance should be installed in
the same closet with the dryer.
The dryer must not be installed or stored in an area
where it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the dryer
with a 1/4" driver. All four legs must rest firmly on the
floor so the weight of the dryer is evenly distributed.
The dryer must not rock.
The dryer needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown below.)
CLOSET
DOOR
D317IE3A
FRONT VIEW
(w/o Closet Door) SIDE VIEW
AAC
A
DE
B
CENTERED
AIR
OPENINGS (G)
(2 Openings
Minimum)
FRONT VIEW
(Closet Door)
F
F
OUTER
WALL OF
ENCLOSURE
**42"
**NOTE: For new installations, locate top of wall vent 42 inches above floor to make venting easier to
connect.
AREA DESCRIPTION FREE STANDING / ALCOVE
INSTALLATION
(See Illustration)
CLOSET INSTALLATION
(See Illustration)
ADryer sides and rear clearance 0" (0 cm) 0" (0 cm)
BDryer top clearance 12" (30.5 cm) 12" (30.5 cm)
CDryer front clearance Not Applicable 2" (5.1 cm)
DExhaust duct clearance to
combustible material 2" (5.1 cm) 2" (5.1 cm)
EWeather hood to ground clearance 12" (30.5 cm) 12" (30.5 cm)
FDistance from floor or ceiling to
hole edge Not Applicable 3" (7.6 cm)
G* Area of centered air openings in
closet door Not Applicable 40 sq. in./open (260 sq. cm)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)

16 504062
Dryer Exhaust Requirements . . .
Never install flexible duct in concealed spaces, such as
a wall or ceiling.
Exhaust System Materials
Exhaust duct must be four inches (10.2 cm) in diameter
having no obstructions. Rigid metal duct is
recommended. Non-combustible semi-rigid flexible
metal duct is acceptable. Do not use plastic pipe or
flexible plastic pipe, because it contributes to poor
drying performance and collects lint, which can lead to
a fire hazard.
DO NOT use sheet metal screws on exhaust pipe joints
or other fastening means which extend into the duct
that could catch lint and reduce the efficiency of the
exhaust system. Secure all joints with duct tape.
Make-Up Air Requirements
For proper operation it is important that you locate the
dryer in an area that has an ample amount of make-up
air to replace the amount exhausted by the dryer.
Energy efficient homes with low air infiltration rates
should be equipped with an air exchanger that can
accommodate on demand make-up air needs in the
home. These devices can be obtained through your
building contractor or building material suppliers.
A clothes dryer produces combustible lint.
To reduce the risk of fire and combustion
gas accumulation the dryer MUST be
exhausted to the outdoors. W116
This gas appliance contains or produces a
chemical or chemicals which can cause
death or serious illness and which are
known to the State of California to cause
cancer, birth defects, or other reproductive
harm. To reduce the risk from substances in
the fuel or from fuel combustion, make sure
this appliance is installed, operated, and
maintained according to the instructions in
this manual. W115
To reduce the risk of fire and the
accumulation of combustion gases, DO NOT
exhaust dryer air into a window well, gas
vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
of a building. W045
To reduce the risk of fire, DO NOT use
plastic pipe or flexible plastic pipe to
exhaust the dryer. W041
WARNING
DOD314IE0C DON'T
D315IE0C

504062 17
Exhaust System
IMPORTANT: Keep exhaust duct as short as
possible.
NOTE: Be certain old ducts are cleaned before
installing your new dryer.
Forbest dryingresults,recommendedmaximumlength
of exhaust system is shown below.
To prevent backdraft when dryer is not in operation,
outer end of exhaust pipe must have a weather hood
with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least
12 inches (30.5 cm) above the ground. Larger
clearances may be necessary for installations where
heavy snowfall can occur.
Exhaust Direction
The dryer can be exhausted to the outdoors through the
back, left, right or bottom of the dryer.EXCEPTION:
Gas dryers cannot be vented out the left side
because of the burner housing.
Dryer is shipped from factory ready for rear exhaust;
no kits required.
Exhausting the dryer through sides or bottom can be
accomplished by installing a DK1 Sales Accessory
(Directional Exhaust Kit 528P3) available as optional
equipment at extra cost.
IMPORTANT: Do not block the airflow at the
bottom of the dryer’s front panel with laundry,
rugs, etc. Blockage will decrease airflow through
the dryer, thus reducing the efficiency of the dryer.
D328IE0A
528P3 Directional Exhaust Kit
Number of
90° Elbows Weather Hood Type
Recommended Use only for short run installations
Maximum length of 4" (10.2 cm) diameter rigid metal duct.
0 44 feet (13.4 m) 34 feet (10.4 m)
1 34 feet (10.4 m) 26 feet (7.9 m)
2 26 feet (7.9 m) 20 feet (6.1 m)
3 20 feet (6.1 m) 14 feet (4.3 m)
Maximum length of 4" (10.2 cm) diameter flexible metal duct.
0 24 feet (7.3 m) 20 feet (6.1 m)
1 20 feet (6.1 m) 16 feet (4.9 m)
2 16 feet (4.9 m) 12 feet (3.7 m)
3 12 feet (3.7 m) 8 feet (2.4 m)
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.
D011IE2D
4"
(10.16 cm)
4"
(10.16 cm)
D011IE2E
2-1/2"
(6.35 cm)

18 504062
Exhaust System Maintenance
The dryer interior and the complete exhaust system
should be inspected after one year of use and cleaned if
necessary. Inspect and clean exhaust duct every one to
two years as required thereafter. The weather hood
should be checked frequently to make sure the dampers
move freely, dampers are not pushed in and that
nothing has been set against them. This maintenance
work should be done by a qualified service person.
Exhausting the dryer in hard-to-reach locations can be
accomplished by installing the 521P3 Flexible Metal
Vent Kit, available as optional equipment at extra cost.
The kit comes in two halves that can be separately
attached to the dryerand wall outlet. Once attached, the
dryer can be slid back into position and the two halves
can be connected from the front.
Dryer Airflow
Efficient dryer operation requires proper dryer airflow.
Proper dryer airflow can be evaluated by measuring the
static pressure.
Static pressure in the dryer’s exhaust duct should be no
greater than that shown in the chart below. (Check with
dryer running and no load.)
NOTE: This can be measured with a manometer
placed on the exhaust duct approximately two feet
(61 cm) from the dryer, see illustration below.
Reduced Clearance Elbow
Installing the dryer in shallow closets can be
accomplished by using an Elbow, Part No. 62688,
which is one inch narrower than a standard venting
elbow.
To reduce the risk of electric shock,
disconnect the electrical service to the dryer
before cleaning. W043
WARNING
D320I
521P3 Flexible Metal Vent Kit
D012IE0A
MANOMETER
EXHAUST
DUCT
Measuring Static Pressure
MAXIMUM STATIC
PRESSURE IN
WATER COLUMN
.4 INCHES (0.1 kPa)
D319IE0A
Reduced Clearance Elbow
Table of contents
Other Kleenmaid Dryer manuals

Kleenmaid
Kleenmaid KED500 User manual

Kleenmaid
Kleenmaid KCDV60 Installation guide

Kleenmaid
Kleenmaid KED2000 Setup guide

Kleenmaid
Kleenmaid KED601 User manual

Kleenmaid
Kleenmaid LEK33AW-4350 User manual

Kleenmaid
Kleenmaid KED400 User manual

Kleenmaid
Kleenmaid LEK37A User manual

Kleenmaid
Kleenmaid KED600 User manual

Kleenmaid
Kleenmaid KED300-Compact User manual

Kleenmaid
Kleenmaid KCDV60 Installation guide