Klein Tools TI250 User manual

FRANÇAIS pg. 17
ESPAÑOL pg. 9
ENGLISH
INSTRUCTION MANUAL
Rechargeable
Thermal Imager
• OVER 10,000
PIXELS TO
TROUBLESHOOT
HOT AND COLD
SPOTS
• ADJUSTABLE
EMISSIVITY
FROM 0.1
TO 0.99
• STORE AND
SHARE IMAGES
WITH OPTIONAL
microSD® CARD
• RECHARGEABLE
LITHIUM ION
BATTERY
T
I
250
ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP XXXXXXX
ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP XXXXXXX
EP 5016393
5001748
-4° – 752°F
-20° – 400°C
2m
www. .com information@itm.com1.800.561.8187

2
GENERAL SPECIFICATIONS
The Klein Tools TI250 is an easy-to-use, USB rechargeable Thermal Imager;
power on to view unseen hot and cold spots for instant troubleshooting. The
meter provides high and low temperature points, crosshairs to pinpoint specific
temperatures, and options for temperature alarms. The addition of a microSD®
card (optional) allows the meter to capture and store images for reporting.
• Environment: Indoor or outdoor
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <90% non-condensing
• Operating Temp: 32°to 113°F (0°to 45°C)
• Storage Temp: -4°to 140°F (-20°to 60°C)
• Sensor: VOX Micro bolometer
• Sensor Resolution: 10800 pixels
• Field of View (FOV): 50 degrees
• Frame Rate: 9 Hz
• Sensitivity: <60 mk
• Temperature Range: -4°to 752° F (-20°to 400° C)
• Temperature Resolution: 0.1°F/0.1°C
• Temperature Accuracy: +/-3° or 3% (whichever greater)
NOTE: Not calibrated below 14°F (-10°C)
• Temperature Display: High, Low, and Center point
• Temperature Settings: °F / C°
• Emissivity: 0.1 to 0.99 adjustable (0.95 default)
• Display Type: 2.4" TFT LCD
• Color Pallets: Ironbow; Rainbow, Gray
• Image Format: BMP
• Image storage: microSD®Card (not included)
• Dimensions: 3.18" × 3.11" × 1.02" (80.8 × 79 × 25.7 mm)
• Weight: 5.5 oz. (156 grams)
• Power:
Lithium polymer battery 3.7V / 1350mAh (USB rechargeable)
• Required Charger Current / Voltage: 800mA / 5V DC
• Charging Current / Time: 450mA / 3 hours
• Auto Power Off: User-selectable for 5, 10, or 30 minutes
• Pollution degree: 2
• Drop Protection: 6.6 ft. (2m)
• Standards: Conforms to UL STD. 61010-1
Certi ed to CSA STD. C22.2 No. 61010-1
Specifications subject to change.
ENGLISH
5001748
microSD® is a registered trademerk of SD-3C, LLC.
www. .com information@itm.com1.800.561.8187

3
WARNINGS
To ensure safe operation and service of the tester, follow these
instructions.
• Read the instructions to ensure safe operation.
• Always wear approved eye protection.
• Do not use if the charging port or housing is damaged in any way.
• Keep the rubber cover over the charging port when not in use.
• Do not expose to direct sunlight, open flame, heat sources, equipment
that produces heat, or extremes of environmental temperature. If battery’s
internal temperature gets too high, the unit will shut down until the
internal temperature is lowered.
• There are no user-serviceable parts inside. DO NOT open or attempt to repair.
NOTE: Do not point the camera at the sun or any other strong energy source.
This can affect the accuracy of the camera or cause damage to the sensor.
WARNING SYMBOLS ON TESTER
Warning or caution
Risk of Electrical Shock
Read instructions before using
OTHER SYMBOLS ON TESTER
USB Charging Port
Conforms with BCS regulations of
California Energy Commission
Conformité Européenne: Conforms with European
Economic Area directives
This product has been independently tested by Intertek
and meets applicable published standards.
WEEE – Battery disposal
microSD®Card Port
Rotating Port Cover (bottom of unit)
www. .com information@itm.com1.800.561.8187

4
23
IMAGER
1. Thermal LCD Screen 7. Micro-USB Charging Port
2. Power On / Off Button 8. microSD® Card Slot
3. Camera Shutter Button 9. Camera
4. Right-Scroll Button 10. Lanyard Hole
5. Left-Scroll Button 11. Rotating Port Cover
6. Menu / Select / Back Button
FEATURE DETAILS
ENGLISH
5
10
6 4
9
7
8
11
1
www. .com information@itm.com1.800.561.8187

5
LCD
A. Center Target Temperature
B. Live Center, High and Low Points
C. Live Temperature Scale
D. Battery Level Indicator
E. Menu Functions
F. Temperature Units (°F / °C)
G. Center Target Temperature and High / Low Temperature On / Off
H. Color Pallets (Ironbow, Rainbow, Gray)
I. Gallery (requires microSD® card, not included)
J. Settings
FEATURE DETAILS
A D
E
C
B
FG H IJ
BB
www. .com information@itm.com1.800.561.8187

6
ENGLISH
OPERATING INSTRUCTIONS
NOTE: Fully charge before first use.
CHARGING
Connect included Micro-USB cable to Micro-USB Charging Port
7
,
and plug the other end into a computer, USB AC adapter, or other USB
power supply (not included). When charging, the battery indicator will
flash for 10 seconds. Normal charging time is about 3 hours.
FUNCTION BUTTONS
Press Power On / Off Button
2
for 2 seconds to power the unit
on or off. When powering on, the start-up screen will display for
10 seconds as the imager runs self-calibration. When complete,
the display will show the thermal image with the center target
temperature and high / low temperatures.
Press Menu / Select Button
6
to access Menu functions and setup.
Use the Right
4
and Left
5
Scroll Buttons to make selections.
MENU FUNCTION
Press the Menu / Select Button
6
and the Menu and Setup
functions (shown below) will appear on the LCD. Use the Right
4
and Left
5
Scroll Buttons to scroll through the functions. Press the
Menu / Select Button
6
to open the function or make a selection. To
exit the function, long press the Menu / Select Button
6
.
F
Temperature Units: Selectable between °F and °C.
G
Center Target Temperature and High / Low Temperature:
Turns these icons on or off.
H
Color Pallets: Selectable between Ironbow, Rainbow, and Gray.
I
Gallery (requires microSD® card, not included):
Scroll through and view captured photos.
J
Settings:
• Temp Bar: Turns feature on or off.
• Time & Date: Sets time and date stamp for images.
• Emissivity: Adjustable from 0.1 to 0.99 (default is 0.95).
• Auto Power Off: Set to 5, 10, or 30 minutes.
• Brightness: User-selectable low, medum, or high.
• HI/LO Alert: Sets temperature alarms.
• Local Info: Provides information on firmware version, capacity,
availability, code, and battery temperature.
• Default Settings Reset: Restores factory-default settings.
• Format SD: Formats microSD®card for use with TI250.
www. .com information@itm.com1.800.561.8187

7
CLEANING
Be sure unit is turned off and wipe with a clean, dry lint-free
cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Do not expose to high temperatures or humidity. After a period of
storage in extreme conditions exceeding the limits mentioned in
the General Specifications section, allow unit to return to normal
operating conditions before using.
OPERATING INSTRUCTIONS
PHOTO CAPTURE
NOTE: microSD®card must be installed before powering on to use
Photo Capture capabilities.
Press Camera Shutter Button
3
to take a photo.
Press the Right Scroll Button
4
to save the photo, or the Left Scroll
Button
5
to discard photo.
PHOTO GALLERY
To view photos, press the Menu / Select Button
6
, then select
Gallery
I
. Use the Right
4
and Left
5
Scroll Buttons to scroll
between photos.
When within the Photo Gallery, a second press of the Menu / Select
Button
6
will open additional options:
•Use the Left Scroll Button
5
to highlight the information icon ,
then press the Menu / Select Button
6
to display information about
the photo (date, time, temperatures, emissivity, etc.) Long press the
Menu / Select Button
6
to exit.
•To delete a photo, select the Trash Can icon , then press the Right
Scroll Button
4
to delete. Long press the Menu / Select Button
6
to exit.
BATTERY INDICATOR
D
• Solid Green: Battery has more than 40% charge remaining
• Partial Yellow: Battery has less than 40% charge remaining
• Partial Red: Low battery, needs recharging
• Blinks Red 10 Times: No Power, Immediate Shut Down
NOTE: For information on a replacement battery for this product,
contact Klein Tools Customer Service.
www. .com information@itm.com1.800.561.8187

8
ENGLISH
www. .com information@itm.com1.800.561.8187
Other manuals for TI250
1
Table of contents
Other Klein Tools Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

OCULUS
OCULUS Mesotest II b instruction manual

Phcbi
Phcbi MDF-U5412 operating instructions

PASCO
PASCO AP-8210A instruction manual

Daihan Scientific
Daihan Scientific MS-MP4 Operation manual

Nippon Genetics Europe
Nippon Genetics Europe FastGene PG01 manual

Bio-Optica
Bio-Optica AUS124 User and service manual

teca
teca AHP-1200MSP Installation

DrBrowns
DrBrowns AC178-INTL Instructions for use

Knauer
Knauer AZURA SMB Pilot instructions

Barnstead International
Barnstead International Harvey Hydroclave MC8 Service manual

Labconco
Labconco FreeZone Triad 74000 Series user manual

PI
PI L-417.XX9025E0B Series user manual