Aqua Ultraviolet Viper SL Series User manual

42371 Avenida Alvarado , Temecula, CA 92590
TOLL FREE (800) 454-2725
TEL (951) 296-3480 FAX (951) 296-3490
www.aquauv.com
INSTALLATION MANUAL
INSTALLATION MANUAL
Viper SL Series
See us on YouTube
www.youtube.com/AquaUltraviolet
BLOG
Find us on Facebook
www.facebook.com/AquaUltraviolet
Follow us on Twitter
www.twitter.com/aquaultraviolet
Read about us at
www.aquaultraviolet.com/blog

T M
Side View
2” Stainless
Steel
3” Stainless
Steel
6” Stainless
Steel
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
VIPER SL 400 WATT STAINLESS STEEL UNITS
VIPER SL 400 WATT PLASTIC UNITS
T M
Side View
2” Plastic 3” Plastic
6” Plastic
ALL VIPERS COME COMPLETE WITH UNIT, TRANSFORMER AND FLOW SWITCH
WIPER OPTION AVAILABLE
CUSTOM UNITS AVAILABLE

LARGE VIPER SL PLASTIC UNITS
800 WATT
3” Stainless Steel Multi Unit
800 WATT
6” Stainless Steel
T
M
FLOW SWITCHES
3” Flow Switch
6” Flow Switch
1200 WATT
6” Stainless Steel
Transformer
T
M
R
WARNING
THISFIXTURE IS DESIGNED FOR USE WITH GERMICIDAL LAMPS AND MUST BE INSTALLED IN
COMPLIANCE WITHCOMPETENT TECHNICAL DIRECTION SO THATTHE USERSEYES AND
BARE
SKINWILL NOT BE SUBJECTED TO INJURIOUS RAYS. SUITABLE FORINDOOR, OUTDOOR, AND
DAMPL OCATIONS.DO NOT S UBMERGEIN WATER. WARNING:RISK OF E LECTRICALSHOCK.
CONNECTO NLY TO A C IRCUIT THAT I S PROTECTED BY A G ROUND-FAULT CIRCUIT
INTERRUPTER(GFCI) CAUTION:R ISK OF E LECTRICAL SHOCK. D ISCONNECT F ROM POWER
SUPPLYBEFORE RELAMPING. CAUTION:RISK OFFIRE USE ONLYAQUA ULTRAVIOLETLAMPSIN
THE INDICATED WATTAGE SIZE. AC ONLY. MAXIMUM RATING OF 50 PSI.
MANUF.#
SERIALNO.
8W
A15
240W
SL400
15W
80W
S100
SL800
25W
114W
S200
SL1200
40W
120W
S300
57W
160W
SL100
A8
200W
SL200
Temecula, CA, USA
TM
TM
TM
TM
ALL VIPERS COME COMPLETE WITH UNIT, TRANSFORMER AND FLOW SWITCH
WIPER OPTION AVAILABLE
CUSTOM UNITS AVAILABLE
800 WATT
3” Plastic Multi Unit 800 WATT
6” Plastic
1200 WATT
6” Plastic
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
LARGE VIPER STAINLESS STEEL UNITS

TABLE OF CONTENTS
1
2
3
4
4
5
6
8
9
10
11
12
14
22
7
16
23
18
26
............................................................................................................... Important Information
.................................................................................................................Warranty Information
..................................................................................................... Warranty Return or Repairs
............................................................................................................................... Introduction
.............................................................................................................. How Ultraviolet Works
............................................................................................................................. Sizing Chart
.................................................................................................... Frequently Asked Questions
........................................................................................................... Viper SL Unit Overview
......................................................................................................... Installation Requirements
........................................................................................................... Pond/Aquarium Layouts
................................................................................................................................ Installation
............................................................................................................Trouble Shooting Leaks
................................................................................................................ Electrical Installation
................................................................................................................. Installing The Lamp
............................................................................................................................... Winterizing
.......................................................................................................... Installing New Lamp Kit
................................................................................................................ Incorrect Installation
..................................................................................................................... Parts Breakdown
.................................................................................................................. Replacement Parts
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490

1
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
THANK YOU FOR PURCHASING THE BEST ULTRAVIOLET SYSTEM
WE CAN HELP YOU
Returning product is expensive and time consuming for you, your retailer and for us, the manufac-
turer. Should you encounter any problems with your product, please call our toll free “HELP” line for
assistance. PLEASE DO NOT return your product to the store! Your dealer or distributor cannot
offer any warranty work or exchanges on your product.
In the US please call
TOLL FREE 1 - 800 - 454 - 2725
(951) 296-3480 Outside the U.S.
THANK YOU!
CAUTION:
This unit must be installed by a
licensed contractor/electrician only.
When installing unit, make sure to
follow all applicable electrical codes.
Various signposts and icons are located throughout the Viper Instruction Manual to assist you. These icons
appear in the text to indicate important or especially helpful items. Here’s a list of the icons and their functions:
NAVIGATING THIS MANUAL
CAUTION -
The caution icon is your warning of a potential problem or pitfall.
HINT -
Hints provide extra knowledge that make the installation process easier.
WARNING -
When you see the warning icon go no further without applying the specific information to your
install.
NOTE -
Notes provide additional or critical information and technical data on the current topic.
IMPORTANT INFORMATION

2AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
WARRANTY INFORMATION
Aqua Ultraviolet systems are warrantied against failure due to defects in materials and/or workmanship during the war-
ranty period. This warranty covers defects occurring under normal use and applies to the original retail purchaser and
may not be transferred. The warranty and remedies set forth herein are conditional upon proper storage, installation, use,
maintenance and conformance with the applicable use. It will be based upon Aqua Ultraviolet’s discretion as to whether
the defects are of manufacturing origin. Any damages due to shipping and handling, packing, or installation are not cov-
ered by this warranty.
This warranty does not apply to appearance or accessory items. This warranty does not include damage due to handling,
transportation, unpacking, set up, installation, repair or replacement of parts supplied by any other than Aqua Ultraviolet,
improper maintenance, incorrect line voltage, modification, or repairs by the purchaser, abuse, misuse, neglect, accident,
fire, flood, or other acts of God.
Any oral statements about product made by the seller, the manufacturer, their representatives or any other parties do not
constitute warranties and shall not be relied upon by the user and are not part of this contract.
Neither the seller nor the manufacturer shall be liable for any injury, loss or damages, direct, incidental or consequential
including but not limited to lost profits, lost sales, injury, inability to use the product and the user agrees that no other rem-
edy is available.
Before installing, the user shall determine the suitability of the product for their intended use and the user shall assume
all risk liability whatsoever in connection therewith.
To validate this warranty, mail the enclosed warranty card within 10 days of purchase along with proof of purchase (copy
of sales receipt).
Warranty Period:
Housing: Limited lifetime warranty on housing against Ultraviolet degradation.
Complete Unit: One year from the date of purchase or 18 months from manufacturing date.
Limitations:
Warranty does not cover any malfunction from improper installation (we recommend that a licensed
electrician install your system to the specifications outlined in this owners guide).
Warranty only applies to the original end user and is not transferable.
Warranty does not cover repairs done by anyone other than Aqua Ultraviolet.
Warranty is void if system is not plugged into a G.F.C.I. (Ground Fault Current Interrupter).
Warranty may not be modified by verbal statements by Aqua Ultraviolet, distributors, retailers, their
agents or any other party.
Warranty covers the repair or prorated replacement of the Aqua Ultraviolet products. Aqua Ultraviolet
denies all liability for any other loss including but not limited to loss of equipment, income, livestock
or personal injury.
Warranty does not cover damage caused by rust or other non-uv causes.
There is no warranty on the Quartz Sleeve.
There is no warranty on broken lamps. Lamps are prorated by usage.
Warranty is voided by the following:
Flow Switch is tampered with, disabled or removed.
Product labels defaced or removed.
Housing has been painted.
Product is improperly installed or maintained by user or agent.
Product abused, misused or damaged by user or their agent.
Product damage caused by electrical surges, electrical spikes, electrical brown outs or
improper voltage.
Electrical cord has been cut.
Minimum flow rate requirements not met.
Unit was run without water.
Any implied warranty granted under state law including warranties of merchantability or fitness for a particular purpose
are limited to one year from the date of purchase or 18 months from the date of manufacture or as otherwise stated in
the above warranty. Aqua Ultraviolet is not responsible for direct, indirect, incidental or consequential damages. Some
states do not allow limitations on how long an implied warranty lasts and/or does not allow the exclusions or limitations
of incidental damages so the above limitation and exclusion may not apply to you. This warranty gives you special legal
rights and you may also have other rights that vary from state to state.

3
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
Warranty Returns or Repair Returns:
Please call Aqua Ultraviolet at (800) 454-2725 for a “Return Merchandise Authorization” number (RMA). You must have a
valid RMA from an Aqua Ultraviolet customer service representative before sending any product in for warranty or re-
pair. Please have your serial number, date of purchase and product type available when calling for an RMA number.
All warranty returns or repair returns must come freight prepaid with an RMA number outside clearly marked on the box.
All other returns will be refused. Aqua Ultraviolet will not be liable for any shipping cost to return warranty or repair items.
Include a note in the box with your RMA number, name, address, daytime phone number and brief description of the rea-
son for return or repair.
Be sure to return product in the same packing or similar packing and insure the package (we recommend sending it
UPS). If you do not have or can’t locate proper packaging, please call our customer service department and we will be
more than happy to send you packaging for a minimal charge.
Aqua Ultraviolet shall not be responsible for damage or loss done by the shipper. Nor shall Aqua Ultraviolet be respon-
sible for merchandise that arrives damaged due to improper packaging. All claims for loss and damage must be filed by
the customer with the shipper.
If unit is found to be out of warranty we will contact you with the cost of repair. Your authorization is required prior to
making any repairs.
WARRANTY INFORMATION

4AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
We at Aqua Ultraviolet would like to take the time to thank you for purchasing the finest ultraviolet
system on the market.
For over thirty years, Aqua Ultraviolet has manufactured ultraviolet systems used in various industries,
including aquaculture, public and commercial aquariums, educational institutions, government agencies and
research organizations throughout the world.
Aqua Ultraviolet sterilizers are used as a control to destroy single celled organisms, water borne bacteria,
viruses, algae, fungi and protozoa. Aqua Ultraviolet sterilizers are recommended for both fresh and salt water
systems as well as ponds. There are no residual effects when using an Aqua Ultraviolet Sterilizer. Ultraviolet
will not affect Bio-filters or lower fish immune systems!
HOW ULTRAVIOLET WORKS
The ultraviolet lamp emits a germicidal ray which alters or disrupts the DNA or RNA of single celled organ-
isms such as algae, bacteria and protozoa. By properly implementing an Aqua Ultraviolet system in-line, these
organisms can be eradicated effectively without any harmful residuals.
Your Aqua Ultraviolet system was made to work as a control for green water and single celled organisms. This
unit will not, nor will any other unit, completely sterilize your pond/aquarium as the pond/aquarium itself is not
a sterile environment. As a control, this unit will effectively lower your water's bacterial count allowing your fish
to stay healthier with less risk of disease.
The Aqua Ultraviolet sterilizer works better on filtered water. Any debris in the water can inhibit UV transmis-
sion.
CAUTION: READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION OR
OPERATION.
NOTE: THE QUARTZ SLEEVE MAY NEED PERIODIC CHECKING AND CLEANING DUE TO
CALCIUM AND MINERAL BUILDUP WHICH WILL INHIBIT UV TRANSMISSION.
The manual should answer most of the questions that you may have about the installation, operation and use
of your new Aqua Ultraviolet Sterilizer. View our installation videos at www.aquauv.com. If you need technical
support, we offer this service for free by telephone (800) 454-2725, or by fax (951) 296-3490 M-F
8:00 am - 4:30 pm Pacific Standard time except selected holidays. You may reach us through the web at
www.aquauv.com.
INTRODUCTION

5
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
SIZING CHART
Min Flow
GPM
Minimum flow rate for all Vipers 95 GPM - 5,700 GPH
Use the clarifier column when the pond is partially in shade and has 50% plant coverage. This will improve water clarity
resulting in a natural looking water garden environment.
Use the sterilizer column for crystal clear water and bacterial control, in pond and aquarium environments.
Sterilizer numbers are based on turning the water over a minimum of 1 to 1-1/2 times per hour for optimal results.
Clarifier numbers are based on turning the water over every 2 to 3 hours.
UV dosage is calculated at the end of lamp life (14 months).
Fresh Water UV Sizing Chart
Minimum flow rate for all Vipers 95 GPM - 5,700 GPH
Reef Tanks: A UV rated in the 30,000 - 45,000 columns is ideal for the reef environment. UV's rated at higher kill
rates will destroy the planktonic food supply for the reef.
Marine Fish Tank (No Reef or Live Rock): A UV rated in the 75,000 to 90,000 columns will be the most effective at
controlling fish disease.
All UV dosages are calculated at end of lamp life (14 months).
Salt Water UV Sizing Chart
VIPER SL UV UNITS
Size Fresh Water
Sterilizer *
In Gallons
30,000
µw/cm2
(EOL)
GPH
Fresh Water
Pond Clarifier ***
Gallons
Viper SL 400 Watt 14,400 - 30,000 17,500 50,000 95 GPM
Viper SL 800 Watt 28,800 - 60,000 35,000 100,000 95 GPM
Viper SL 1200 Watt 43,200 - 90,000 52,500 150,000 95 GPM
VIPER SL UV UNITS
**Salt
Water
Tank
Gallons
30,000
µw/cm2
(EOL)
GPH
45,000
µw/cm2
(EOL)
GPH
60,000
µw/cm2
(EOL)
GPH
75,000
µw/cm2
(EOL)
GPH
90,000
µw/cm2
(EOL)
GPH
Viper SL 400 Watt 3,600 17,500 11,667 8,750 7,000 5,833
Viper SL 800 Watt 7,200 35,000 23,333 17,500 14,000 11,667
Viper SL 1200 Watt 10,800 52,500 35,000 26,750 21,000 17,500

6AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
Where do I install my UV?
The best place to install your Viper SL is after the filter and lower than the return water line. If an after the
filter installation is not feasible, your sterilizer can be installed before the filter, but consideration must be
given to the total dissolved solids in the water that may inhibit UV transmission.
Is the Flow Switch Necessary?
YES, The Viper SL Units are water cooled and the flow switch turns the Viper SL off when the flow is below
the minimum requirement of 95 GPM. The Warranty is voided if the Flow Switch is tampered with, disabled
or removed.
Do I have to turn my UV off when I clean my filter?
Yes, the Viper SL Units are completely water cooled, and should not be run without water or when water is
at a stand still for any length of time. This may cause extensive, irreversible damage to the unit and is not
covered under warranty.
Do I install my UV vertically or horizontally?
The Viper SL Ultraviolet Sterilizer must be installed horizontally.
What should my flow rate be on my pond or fresh water aquarium?
The optimum flow rate on your pond or fresh water aquarium is to turn over the volume of water once every
hour or a minimum of once every one and one half hours. Please also note the minimum flow rate require-
ment of 95 gallons per minute.
What should my flow rate be on my salt water aquarium?
Your minimum flow rate should be 3 to 5 times the volume of water per hour. Please also note the minimum
flow rate requirement of 95 gallons per minute.
Should I bypass part of my water through the UV and the rest back to the water supply?
No. Our UV's are specifically designed to handle high flow rates for easier installation and the best water
quality.
Is this unit submersible?
Not this specific series.
Does the UV light have any residual effect to the fish?
UV only effects what passes through the chamber. There is no residual effect from UV light.
Does the UV kill good bacteria?
Ultraviolet light does not discriminate about what it destroys. If good bacteria passes by the light it will be
destroyed. Beneficial bacteria are colonized in your filter and along the sides and bottom of your pond. The
only time these will be affected is if they become free floating. All the bacteria in the filter are safe because
UV has no residual.
How often should I change my lamp?
The lamp, quartz sleeve and seals should be replaced after 14 months of continuous use.
FREQUENTLY ASKED QUESTIONS

7
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
VIPER SL UNIT OVERVIEW
IMPORTANT: Please Read Before Beginning Installation
NOTE: All units are quality tested at the factory. All units are rated up to 50 PSI.
CAUTION: You must install this unit in the described manner, if you choose to install your
unit in any other manner, the unit may malfunction and cause irreversible damage that is not
covered under warranty.
WARNING: Before mounting or installing your unit check the quartz sleeve. Do not try to install,
mount or operate this unit if the quartz sleeve appears to be broken or cracked. Contact your dealer,
for a new Quartz Sleeve.
CAUTION: PERFORM A LEAK TEST: INSTALL THE UNIT WITHOUT THE LAMP AND
BALLAST. PUMP WATER THROUGH. CHECK FOR LEAKS THEN INSTALL LAMP AND BALLAST!
READ AND FOLLOW ALL INSTRUCTIONS AND/OR SAFETY INSTRUCTIONS FIRST!
CAUTION: Your Aqua Ultraviolet unit is not submersible. If this unit falls into the water, turn the main
power off and then retrieve it. Do not attempt to use this sterilizer if it has been submerged. Do not
operate this unit if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or
been damaged in any manner.
HINT: The UV should be installed after the filter on the return line. This ensures the water is clear of
debris that could inhibit the UV's effectiveness. The UV can be installed before the filter, however,
consideration must be given to the total dissolved solids that may inhibit UV transmission.
CAUTION: THIS UNIT MUST HAVE WATER FLOWING
THROUGH IT OR IT WILL BURN UP. THIS PROBLEM IS NOT
COVERED UNDER WARRANTY AND YOU WILL NEED TO
PURCHASE A NEW UNIT!
Warranty is Void if the Flow Switch is tampered with,
disabled or removed.

8AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
INSTALLATION REQUIREMENTS
NOTE: Your Viper SL Unit must be installed lower than the return water line in one of the fol-
lowing configurations, to ensure the chamber stays full of water. Installing your Viper SL in
any other manner may void the warranty, and may cause fire.
CAUTION: THIS UNIT MUST HAVE
WATER FLOWING THROUGH
IT OR IT WILL BURN UP. THIS
PROBLEM IS NOT COVERED
UNDER WARRANTY AND YOU
WILL NEED TO PURCHASE A
NEW UNIT!
From Water Source
To Filter
Return to water source
From Water Source
To Filter
Return to water source
From Water Source
To Filter
Return to water source
Viper 3" Plastic 3" Flow Switch
Viper 2" Plastic with Attached Flow Switch
Viper 2" Stainless Steel
with Attached Flow Switch

9
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
Bottom
Drain
Return Or
Waterfall
Optional
Jets
Flow In
Flow Out
Bottom
Drain
Return Or
Waterfall
Optional
Jets
Flow In
Flow Out
Bottom
Drain
Return Or
Waterfall
Optional
Jets
Flow Out
Flow In
Optional
Jets
Flow Out
Bottom
Drain
Return Or
Waterfall
Optional
Jets
Flow Out
Optional
Jets
Correct Installation
Incorrect Installation
Bottom
Drain
Return Or
Waterfall
Bottom
Drain
Return Or
Waterfall
Flow In
Flow Out
Flow In
Flow Out
Flow In
LAYOUTS
Pickup on the bottom of one side of the tank and return to top of the opposite side of the tank.
RECOMMENDED POND LAYOUTS
RECOMMENDED AQUARIUM LAYOUT
Ultima II Filter
From Water Source
To Filter
Return to water source
The drain should pick up on the bottom of one side and return to the top of the opposite side.
The Bottom drain pick up is too close to return.

10 AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
VIPER SL SERIES INSTALLATION INSTRUCTIONS
Flow Switch
Assembly
2" Example
3" or 6" Example
When installing a 3" Viper or larger, the Flow Switch is not attached to the unit body and must be
installed in line before the unit.
Water Flow
Water Flow
Water Flow
Water Flow
OVERVIEW: This unit can only be installed horizontally, DO NOT install vertically. Do not install at ground
level to prevent it from lying in standing water. Your system should be easily accessible and as close to the
filter as possible. Do not submerge.
1. MOUNTING: Make sure water flow direction corresponds with the arrow below.
2. WATER LINE CONNECTION: Glue union to your pipe making sure water flow matches the arrow's direction
below.
CAUTION: If there are no leaks, turn the pump off and continue to the ELECTRICAL INSTALLATION
on page 12. If your unit leaks turn to the next page for leak solutions.
WARNING: DO NOT CONTINUE UNTIL YOUR INSTALLATION PASSES THE
LEAK TEST
3. LEAK TESTING: Do not install lamp or electrical components yet. After all the connections have been made
and the glue dries, turn the pump on and run it for five minutes to check for leaks.

11
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
TROUBLE SHOOTING LEAKS
If your unit is leaking turn off your pump and troubleshoot using the following guide.
A. If your unit leaks from the Quartz Cap:
1. Hand Tighten Quartz Cap until leak stops
2. Turn the pump on and run it for 5 minutes to check for leaks.
Union
Leak
EZ-Twist Top
Leak
Quartz Cap
Leak
Quartz Cap
Leak
WARNING: DO NOT CONTINUE UNTIL YOUR INSTALLATION PASSES THE
LEAK TEST
D. If your unit leaks from the Union:
1. Please contact our customer service
at: (800) 454-2725
C. If your unit leaks from the EZ-Twist Top:
1. Check that the O-ring is in the EZ- Twist Top
2. Hand tighten EZ-Twist Top until leak stops
3. Turn the pump on and run it for 5 minutes to check for leaks.
B. If your unit leaks from the Quartz Sleeve:
1. Check Quartz Sleeve for cracks or breakage. If there are
cracks or breakage, a new Quartz Sleeve will be needed.
2. Contact a dealer to purchase a new Quartz Sleeve.

12 AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
R
WARNING
THISFIXTURE IS DESIGNED FOR USE WITH GERMICIDAL LAMPS AND MUST BE INSTALLED IN
COMPLIANCE WITHCOMPETENT TECHNICAL DIRECTIONSO THAT THEUSERS EYES AND
BARE
SKIN WILLNOT BE SUBJECTED TOINJURIOUS RAYS. SUITABLE FOR INDOOR,OUTDOOR, AND
DAMPL OCATIONS.DO N OTSUBMERGE IN WATER. WARNING:RIS KOF ELECTRICA LSHOCK.
CONNECT O NLY TOA C IRCUIT T HATISP ROTECTED B Y A GROUND-FAULT CIRCUIT
INTERRUPTER(GFCI) CAUTION: RISK OF E LECTRICAL SHOCK. D ISCONNECT F ROM POWER
SUPPLY BEFORERELAMPING. CAUTION:RISK OFFIRE USEONLYAQUA ULTRAVIOLETLAMPS IN
THEINDICATED WATTAGE SIZE. AC ONLY. MAXIMUMRATING OF 50 PSI.
MANUF.#
SERIALNO.
8W
A15
240W
SL400
15W
80W
S100
SL800
25W
114W
S200
SL1200
40W
120W
S300
57W
160W
SL100
A8
200W
SL200
Temecula, CA, USA
ELECTRICAL INSTALLATION
G.F.C.I. Outlet
CAUTION: This unit should be installed by a licensed electrician.
CAUTION: The 220V transformer must be hardwired into a dedicated 20 amp line of the
appropriate voltage and hertz. (The 110V transformer does not need to be hardwired.)
CAUTION: The 220V transformer must be hardwired into a dedicated line with a steady
voltage output. If the voltage is not steady or the unit is not wired into a clean line
irreversible damage may occur to the unit which is not covered under warranty.
CAUTION: GFCI Information: The warranty is null and void if the Viper SL unit is not
plugged into a G.F.C.I. (Ground Fault Circuit Interrupter). A Surge Suppressor should be
added for extra protection, it is not required, but recommended.
1. COVER REMOVAL: Remove the cover from the transformer box to allow access to screw holes located on the back
panel of the box. The cover slides down.
2. MOUNTING: Mount the Transformer vertically on to a wall or other sturdy surface a minimum of 4 feet away from any
dwelling. Make sure the transformer is close enough to attach to the UV unit.
3. 220V TRANSFORMER: Must be hardwired into a dedicated 20 Amp Line of the appropriate voltage and hertz.
4. 110V TRANSFORMER: Plug into 3 prong G.F.C.I. Outlet.

13
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
8. Make sure all connections are tight. Plug the Clip
Connectors together, making sure the connection is flush.
7. Tighten the lock nut inside the transformer and retighten the
Davis Connector.
6. Thread the flow switch wire and the Davis Connector
fitting through the transformer opening.
ELECTRICAL INSTALLATION
5. Unscrew the Davis Connector, and lock nut.
INSTALL FLOW SWITCH CONNECTION
U
n
s
c
r
e
w
Lock Nut
C
o
n
n
e
c
t
o
r
D
a
v
i
s
9. Return the cover to the transformer box.
Warranty is Void if the Flow Switch is tampered with,
disabled or removed.
Flush
Installation

14 AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
Quartz SleeveLampClip Connector Clip Connector
NOTE: Do not force the Lamp into the Quartz Sleeve.
INSTALLING THE LAMP
Flush
Installation
Clip Connector
(Female)
Clip Connector
(Male)
2. CONNECT THE LAMP: Plug the Lamp into each of the
Clip Connectors located at the end of the Harness.
Make sure the Lamp is plugged in all the way and flush with
each of the Clip Connectors.
WARNING: Be careful when installing the lamp. If the lamp is not plugged in all the way this
may cause damage to the unit and is not covered under warranty, nor is any other damage
caused by improper installation.
1. INSTALLING THE LAMP: Extend Lamp Wires and
insert into Quartz Sleeve. Position Lamp so that the Clip
Connectors are visible on both ends of the unit.
NOTE: If you touch the lamp use denatured alcohol and a soft cloth to clean it. If you do
not clean the lamp the fingerprints will become etched into the glass which will diminish UV
Output and may cause premature lamp failure.
NOTE: Lamps and Quartz Sleeves should be handled with care. Lamps and Quartz Sleeves
are not warranted against breakage and damage.
WARNING: Do not install the lamp at an angle (even a slight angle); this may cause a U
shaped crack at the end of the quartz sleeve, or possible breakage of the lamp. If this should
happen, do not proceed with the installation. Purchase a new Quartz Sleeve or Lamp from
your dealer and refer to the proper installation instructions.

15
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
INSTALLING THE LAMP - Continued
Davis Connector
Transformer Cap
Wire
Clip Connector
(Female)
Quartz Cap
Transformer Cap
Davis Connector
4. CONNECT THE TRANSFORMER CAP: Twist on transformer cap. Do not over tighten. This is a
connection only and is not in contact with water. Do not use a pipe wrench, pliers or any other tool, hand
tighten only.
3. DISCONNECT THE DAVIS CONNECTOR: Unscrew the Davis Connector located just above the
Transformer Cap. This will allow the Transformer Cap to turn without kinking the Harness cord.
Quartz Cap
Transformer Cap
Davis Connector
5. Tighten the Davis Connector located just above the Transformer Cap.
6. FINAL LEAK CHECK: Do not plug the sterilizer into power yet, turn on pump and check for leaks again.
For illustrations, SEE PAGE 11.
a. If you have a leak, return to Trouble Shooting Leaks on page 11. Carefully examine
this unit after installation. This unit should not be plugged in if there are any leaks on
any part of this unit.
b. If there are no leaks, turn on power.
CAUTION: Do not look at or handle UV Lamps when lit outside of the housing. Considerable Ultraviolet energy
is emitted which may produce severe sunburn and/or conjunctivitis. As long as the UV Light is in its housing it is
100% safe for humans and fi sh.
NOTE: The average life expectancy of Aqua Ultraviolet Lamps is 14 months of continuous operation. After 14
months the lamp may still light, but the germicidal rays are diminished.
NOTE: We recommend that the UV Sterilizer be used in continuous operation 24 hours a day, 7 days a week.
Frequent Starts and Stops may shorten the life of your lamps.
WARNING: If you are medicating your fi sh, we recommend shutting down the sterilizer as the UV Radiation may
affect the treatment.
CAUTION: Do not use the Aqua Ultraviolet Sterilizer for anything other than its intended use.

16 AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
WINTERIZING
OPTION 1: If you are going to continually run water through your unit and it will be exposed to freezing
temperatures be sure to install winterizing caps (sold separately) on both sides of the unit and take all the
internal parts inside (Quartz Sleeve, EZ-Twist Top, Quartz Caps, Lamps, Rubber Seals, and or Bushings).
Transformer Box may be left outside.
A40007
Winter Cap
(2 required)
CAUTION: Always turn off the pump and disconnect electricity from the unit prior to any
maintenance.
Take These Parts Inside
OPTION 2: If you shut down your system for winter (no water flowing) remove the lamp and store separately.
Disconnect unions or flanges and take the Viper UV Sterilizer inside.
WINTERIZING: 2" or 3" Plastic Viper
Quartz Cap
EZ-Twist Cap Quartz Sleeve
Rubber Seal
Bushing
Seal
Lamp
Rubber
Rubber Seal
Bushing
EZ Twist Top
O-Ring
U
nscrew Unions
(Both Ends)
Remove Lamp
Viper UV
Sterilizer
U
n
s
c
r
e
w
C
a
p
This manual suits for next models
3
Table of contents
Other Aqua Ultraviolet Laboratory Equipment manuals

Aqua Ultraviolet
Aqua Ultraviolet Classic Series User manual

Aqua Ultraviolet
Aqua Ultraviolet SL 100 Watt User manual

Aqua Ultraviolet
Aqua Ultraviolet Classic Series Use and care manual

Aqua Ultraviolet
Aqua Ultraviolet STATUARY 8 Watt 1/L User manual

Aqua Ultraviolet
Aqua Ultraviolet A00001 User manual

Aqua Ultraviolet
Aqua Ultraviolet Ozone UV 8 Watt Unit User manual

Aqua Ultraviolet
Aqua Ultraviolet Advantage 2000 User manual