manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Klein Tools
  6. •
  7. Measuring Instrument
  8. •
  9. Klein Tools CL2000 User manual

Klein Tools CL2000 User manual

CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
www.kleintools.com
139540T Rev. 11/13 B
ENGLISH
• TRUE RMS
• AUTO /MANUAL
RANGE
• NON CONTACT
VOLTAGE TESTER
• RELATIVE /ZERO
• BAR GRAPH
• MAX /MIN / HOLD
• 3-3/4 DIGIT
3999 COUNT LCD
• BACKLIGHT
• WORKLIGHT
V
AT
0 10 20 4030
Apo
600V
400A
CATIII
CL2000
ENGLISH
8. Non Contact Voltage (NCV): >25V AC
SYMBOLS USED ON LCD
~
AC Measurement DC Measurement
-
Negative DC Value
AT
Auto Range Active
O
.L.
Overload: Range Exceeded Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
M
AX
Maximum Reading
%
Duty Cycle Mode Frequency Mode
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in Ohms Diode Test
F
Capacitance in Farads Continuity Test
Relative / Zero Mode
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range Resolution Accuracy
400mV ˜400V 0.1mV ˜0.1V ± (0.5% + 4 digits)
1000V 1V ± (0.8% + 10 digits)
Overload Protection: 1000V
AC Voltage Measurement
Range Resolution Accuracy
400mV ˜ 750V 0.1mV ˜1V ± (2.0% + 5 digits)
Overload Protection: 750V RMS
Frequency Response: 40 to 400Hz
Minimum Voltage for Frequency Measurement: 200mV
Response: True RMS
Continuity Test
Overload Protection Open Circuit Voltage
600V RMS < 0.44V
Non Contact Voltage Detector
On Voltage
Appx. 25V AC
DC Current Measurement
Range Resolution Accuracy
400µA 0.1µA ± (1.2% + 3 digits)
2000µA 1µA
40A 0.01A ± (2.5% + 15 digits)
400A 0.1A ± (1.5% + 8 digits)
Overload Protection:
• Voltage: 600V RMS
• Current: 2000µA
AC Current Measurement
Range Resolution Accuracy
400µA 0.1µA ± (2.0% + 5 digits)
2000µA 1µA ± (1.5% + 5 digits)
40A 0.01A ± (2.9 % + 15 digits)
400A 0.1A ± (1.9% + 8 digits)
Overload Protection:
• Voltage: 600V RMS
• Current: 2000µA
Frequency: 45 to 400Hz
Minimum Current for Frequency Measurement: 400µA or 20A
Response: True RMS
Resistance Measurement
Range Resolution Accuracy
400Ω˜ 4MΩ0.1Ω˜ 0.001MΩ± (1.0% + 4 digits)
40MΩ0.01MΩ± (2.0% + 4 digits)
Overload Protection: 600V RMS
Capacitance Measurement
Range Resolution Accuracy
40nF ˜ 4000µF 0.01nF ˜ 1µF ± (3.5% + 6 digits)
Overload Protection: 600V RMS
Frequency Measurement
Range Resolution Accuracy
9.999Hz ˜999.9kHz 0.001Hz ˜ 0.1kHz ± (0.1% + 4 digits)
Overload Protection: 600V RMS
Duty Cycle Measurement
Range Resolution Accuracy
0.1 ˜99.9% 0.1% ± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection: 600V RMS
Diode Test
Overload Protection Range Test Current Open Circuit Voltage
600V RMS 2.0V Appx. 0.25mA < 1.6V DC

600V
400V
CATIII
CL1000
PRESS
and
HOLD
PRESS
and
HOLD
WARRANTY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL /RECYCLE
Caution: This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
750V
1000V
400A
Dwg Name: CL2000-139540TART Dwg No: 139540T
ECO No: 14678 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A
Instruction Manual
CL2000
CL2000 Instruction Manuals - MASTER.indd 1-4 11/20/2013 2:54:10 PM
ENGLISH
PRESS
V
AT
0 10 20 4030
Apo
PRESS
V
AT
0 10 20 4030
Apo
V
AT
0 10 20 4030
Apo
V
AT
0 10 20 4030
Apo
V
AT
0 10 20 4030
Apo
600V
400A
CATIII
CL2000
PRESS
FEATURE DETAILS
CL2000
Instruction Manual
GENERAL SPECIFICATIONS
The Klein Tools CL2000 is a True RMS, auto-ranging clamp meter.
It measures AC / DC voltage, AC /DC current, resistance, capacitance,
frequency, and duty cycle. It can also test non-contact voltage, diodes,
and continuity.
• Operating Altitude: 2000 meters
• Humidity: 80% max
• Operating Temperature: 0°C /32°F to 45°C /113°F
• Storage Temperature: 0°C /32°F to 60°C /140°F
• Accuracy Temperature: 18°C /64°F to 28°C /82°F
• Temperature Coefcient: 0.1*(specified accuracy) /°C
• Dimensions: 8.875" x 3.375" x 1.5" (225 mm x 86 mm x 38 mm)
• Weight: 10.7 oz. (303 g)
• Calibration: Accurate for one year
• Safety Rating: CAT III 600V
• Accuracy: ± (% of reading + # of least significant digits)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring
a known voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms, or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from
the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes
are connected.
• Use caution when working with voltages above 60V DC,
or 25V AC RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock,
replace batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out
power before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.
SYMBOLS
~
AC Alternating Current Warning or Caution
DC Direct Current Dangerous levels
DC/AC Voltage or Current Double Insulated Class II
Ground Safe for disconnect
from live conductors
AC Source
A. Use CAT III rated leads or higher.
Do not attempt to measure more than
1000V DC or 750V AC or 2000µA.
B. Keep hands below line when measuring high current levels.
C. Auto Power-Off (Apo)
• Device will power off after 30 minutes non-use.
• Turn the dial or press a button to wake.
• Disabled during Max / Min function.
• Holding Select button while turning on disables Auto Power-Off.
D. Select Functionality Button
• Switch between AC and DC.
• Switch between and .
E. Hold /Backlight / Worklight
• Press to hold the current input on the display.
• Press again to return to live reading.
• Press for 2 seconds to enable / disable lights.
• Using lights drains the battery significantly.
F. Auto / Manual Range
• Press repeatedly to cycle through manual ranges.
• Press for 2 seconds to return to auto ranging mode.
• AT is displayed on LCD only during auto ranging mode.
G. Max / Min Hold
• Press to enter Max /Min mode; the largest and smallest
values will be saved while in this mode.
• Press repeatedly to alternate between the maximum and minimum readings.
• Press for 2 seconds to return to live reading and clear
the stored maximum and minimum values.
H. I. Battery Replacement
• When indicator is displayed on the LCD, batteries must be replaced.
• Remove the back screw and replace 2 x AAA batteries.
J. Magnetic Back
• Attach instrument to metal for hands-free use.
K. Bar Graph
• The bar graph shows an approximate analog representation
of a measurement.
• The bar graph responds much faster than the digital display.
• The scale of the bar graph is zero to the maximum reading of
the selected range.
L. Relative Reading / Zero Mode
• Press for 2 seconds to enable/disable mode and store reading.
• Display will show the difference between the stored reading and
the live measurement.
FUNCTION INSTRUCTIONS
7
1
6
2
3
5
1. AC /DC Current (large): < 400A
Features:
ZERO (DC) REL (AC)
MAX/MINRANGEHOLD
• Center wire in guides for best accuracy.
• Opposing currents cancel. Use line-splitter (USA only) when necessary.
2. AC /DC Current (small): <2000µA
Features:
ZERO (DC) REL (AC)
MAX/MINRANGEHOLD
• Select AC or DC current source.
• Current above 2000µA will damage instrument.
3. AC /DC Voltage: <750V AC or 1000V DC
Features:
REL
MAX/MINRANGEHOLD
• Select AC or DC voltage source.
4. Frequency (Hz) / Duty Cycle (See Feature Details)
Features:
HOLD
• Select , , or setting.
• Frequencies greater than 1MHz will display “0.000Hz”.
5. Resistance:
<40MΩ
Features:
MAX/MINRANGEHOLD
• Do not measure resistance on a live circuit.
6. Capacitance:
<4000µF
Features:
HOLD
• Safely discharge capacitor before measurement.
• Reading may take up to 60 seconds for large capacitors.
7. Diode /Continuity
Display shows:
• Forward voltage drop if forward biased.
• “O.L.” if reverse biased.
Diode Features:
• Display shows resistance.
• Buzzer sounds if less than 30Ω.
Continuity Features:
HOLD MAX/MIN
TO SELECT
Diode
Continuity
PRESS
V
AT
0 10 20 4030
Apo
V
AT
0 10 20 4030
Apo
PRESS
Duty
Cycle
Hz
V
AT
0 10 20 4030
Apo
600V
400V
CATIII
B
A
I
8
J
4
600V
400V
CATIII
K
C
D
F
E
G
H
HOLD MAX/MIN
L
1
Dwg Name: CL2000-139540TART Dwg No: 139540T
ECO No: 14678 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A
CL2000 Instruction Manuals - MASTER.indd 5-8 11/20/2013 2:54:12 PM

Other manuals for CL2000

1

Other Klein Tools Measuring Instrument manuals

Klein Tools 93LDM65 User manual

Klein Tools

Klein Tools 93LDM65 User manual

Klein Tools CL2000 User manual

Klein Tools

Klein Tools CL2000 User manual

Klein Tools ET920 User manual

Klein Tools

Klein Tools ET920 User manual

Klein Tools ET140 User manual

Klein Tools

Klein Tools ET140 User manual

Klein Tools CL450 User manual

Klein Tools

Klein Tools CL450 User manual

Klein Tools CL600 User manual

Klein Tools

Klein Tools CL600 User manual

Klein Tools CL390 User manual

Klein Tools

Klein Tools CL390 User manual

Klein Tools CL360 User manual

Klein Tools

Klein Tools CL360 User manual

Klein Tools VDV512-110 User manual

Klein Tools

Klein Tools VDV512-110 User manual

Klein Tools CL110 User manual

Klein Tools

Klein Tools CL110 User manual

Klein Tools Probe-Pro User manual

Klein Tools

Klein Tools Probe-Pro User manual

Klein Tools ET110 User manual

Klein Tools

Klein Tools ET110 User manual

Klein Tools CL450 User manual

Klein Tools

Klein Tools CL450 User manual

Klein Tools VDV500-123 Probe-Pro User manual

Klein Tools

Klein Tools VDV500-123 Probe-Pro User manual

Klein Tools MM6000 User manual

Klein Tools

Klein Tools MM6000 User manual

Klein Tools VDV500-051 User manual

Klein Tools

Klein Tools VDV500-051 User manual

Klein Tools IR3000 User manual

Klein Tools

Klein Tools IR3000 User manual

Klein Tools CL3200 User manual

Klein Tools

Klein Tools CL3200 User manual

Klein Tools CL800 User manual

Klein Tools

Klein Tools CL800 User manual

Klein Tools CL700 User manual

Klein Tools

Klein Tools CL700 User manual

Klein Tools CL440 User manual

Klein Tools

Klein Tools CL440 User manual

Klein Tools NCVT-1 User manual

Klein Tools

Klein Tools NCVT-1 User manual

Klein Tools LAN Scout Jr. 2 User manual

Klein Tools

Klein Tools LAN Scout Jr. 2 User manual

Klein Tools VDV501-089 User manual

Klein Tools

Klein Tools VDV501-089 User manual

Popular Measuring Instrument manuals by other brands

Tektronix Keithley 4200A-SCS Setup and Maintenance

Tektronix

Tektronix Keithley 4200A-SCS Setup and Maintenance

Lippert Tire Linc OEM INSTALLATION MANUAL

Lippert

Lippert Tire Linc OEM INSTALLATION MANUAL

Triplett CM650 user manual

Triplett

Triplett CM650 user manual

PRO SHOT L4 manual

PRO SHOT

PRO SHOT L4 manual

Bitzer 4FC-3.2 Series technical information

Bitzer

Bitzer 4FC-3.2 Series technical information

ParTech 228531 instruction manual

ParTech

ParTech 228531 instruction manual

JEWELL JD Series user guide

JEWELL

JEWELL JD Series user guide

Keysight Technologies N5224A Service guide

Keysight Technologies

Keysight Technologies N5224A Service guide

Powerfix Profi DIGITAL CALLIPER Operation and safety notes

Powerfix Profi

Powerfix Profi DIGITAL CALLIPER Operation and safety notes

ATP Instrumentation LX-1309 manual

ATP Instrumentation

ATP Instrumentation LX-1309 manual

Martin Professional The Wife user manual

Martin Professional

Martin Professional The Wife user manual

Newall NMS 100 user manual

Newall

Newall NMS 100 user manual

GMI First Responder User handbook

GMI

GMI First Responder User handbook

Proceq Profometer 5+ operating instructions

Proceq

Proceq Profometer 5+ operating instructions

Baylan YGHP ER34615 user guide

Baylan

Baylan YGHP ER34615 user guide

Hanna Instruments HI 2400 instruction manual

Hanna Instruments

Hanna Instruments HI 2400 instruction manual

Aventics VTM operating instructions

Aventics

Aventics VTM operating instructions

CSM HV DTemp Series user guide

CSM

CSM HV DTemp Series user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.