Klimaire KSIH Series User manual

Thank you very much for purchasing our products.
Please read this manual carefully before using the
remote controller.
REMOTE CONTROLLER ILLUSTRATION
(Function selection)
SERIES
KSIH

3
4
4
6
Handling the remote controller ...................................
Remote controller specification...................................
Features of remote controller buttons .......................
How to set up the funcitons.........................................
CONTENTS

Keep the remote controller where its
signals can reach the receiver of the
indoor unit. (a distance of 8m is allowed).
Location of the remote controller.
8m
CAUTIONS
The air conditioner will not operate if curtains, doors or other
materials block the signals from the remote controller to the indoor
unit.
Prevent any liquid from falling into the remote controller. Do not
expose the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct
sunlight, the air conditioner may not function properly. Use curtains
to prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote controller, either
move these appliances or consult your local dealer.
The remote controller uses two
alkaline dry batteries (R03/LR03X2)
(1) Slide the cover of the battery
compartment off according to the
arrow direction, then replace the
old batteries with new ones.
(2) Insert the new batteries, making
sure that the(+) and (-) of battery
are installed correctly.
(3) Reattach the cover by sliding it
back into position.
NOTE:
Do not mix old and new batteries
or batteries of different types.
Do not leave the batteries in the
remote controller if they are not
going to be used for 2 or 3 months.
Do not dispose batteries as
unsorted municipal waste.
Collection of such waste separately
for special treatment is necessary.
Replacing batteries
Handling the remote controller
3
POWER
OFF
MODIFY
ADJUST
CONFIRM

4
Model
Rated Voltage
8m
3.0V(Dry batteries R03/LR03×2)
Remote Controller Specification
Environment
Signal Receiving Range
Features of Remote Controller buttons
NOTE: After installing the batteries, during the first 30 seconds
period, please holding down the MODE, FAN and TIME ON
buttons together for 5 seconds, the remote controller will enter
function reset state, and LCD window displays “F1".
MODE
FAN
TEMP
SLEEP FRESH
LED FOLLOW ME
TURBO SELF CLEAN
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF
-5ºC~60ºC
RG57A3/BGEF

5
ON/OFF
MODE
TEMP
TIMER ON
TIMER OFF
POWER OFF button: Press this button to turn off
the unit
TIMER ON button: Press this button to confirm the
setting parameter and transmit the singal to the
machine.
FAN & TIMER OFF button: On parameter setting
interface, pressing FAN & TIMER OFF button to
select parameter to be modified.
TEMP “ ”& “ ” button: Used to choose
functions or adjust parameters. On parameter
unadjustable interface, press the “ ” & “ ”
button to select the specified function in a
range of F1 ~ F9 and E1~E9. Then pressing the
MODE button to enter the parameter modifying
interface, the relevant parameter flashes, pressing
“ ” & “ ” button to adjust the paramter.
MODE button: Used to modify the selected
function. Press this button to enter the parameter
setting interface, and the parameter to be modified
will be kept flashing. Using TEMP “ ” & “ ”
button to modify the parameter or choosing the
other parameter in conjuction with “FAN” & “TIMER
OFF” button.
LOCK button: Hold and press this two buttons for
2 seconds, all current settings of indoor unit are locked
in and the remote controller does not accept any
operation except that of the LOCK.
IMPORTANT: The remote controller is only enabled within10
minutes after the indoor unit is powered on, and the indoor unit
must be switched off.
FAN
SLEEP FRESH

6
Auto-start function
Heating temperature compensation
1. Press “ ” & “ ” button to choose “F2”.
1. Press “ ” & “ ”
button to choose “F1".
2. Press MODE button. Then
press “ ” & “ ” button to
choose “On” or “Off”.
2. Press MODE button. Then press “ ” & “ ” button to
choose the parameter. The parameters can be adjusted
within a range of -6ºC~6ºC.
How to set up the functions
TEMP
TEMP
ADJUST
MODE
MODE
3. Press TIMER ON button, and the Auto-start function on/off
setting has finished.
TIMER ON
NOTE: The indoor unit will beep for 2 seconds indicating the
function being set up successfully.
-
---
--.... ....
....
....

7
3. Press TIMER ON button.
TIMER ON
Anti-cold air function
Intelligent anti-cold air function setting:
NOTE: The parameter of intelligent anti-cold air is changed with the
room temperature. After the room temperature raised, the temperature
of anti-cold air would raise too, which can make you feel more comfortable.
After the room temperature decreased, the anti-cold air temperature
would decrease too, which can improve the fan speed and bring fast
heating operation.
1. Press “ ” & “ ” button to choose “F3”.
TEMP
Flashing
Flashing
3. Press TIMER OFF button to adjust the parameter. The parameter
keeps flashing. Then press “ ” & “ ” button to adjust the
parameter in the range of 17ºC~21ºC.
2. Press MODE button. Press FAN button to to choose
parameter . Then press “ ” & “ ” button to select “1”.
MODE
TIMER OFF
FAN
4. Press TIMER ON button to confirm.
TIMER ON
TEMP
TEMP

8
Flashing
Flashing
3.Press TIMER OFF button to adjust the parameter. The parameter
keeps flashing. Then press “ ” & “ ” button to adjust the
parameter in the range of 8ºC~28ºC.
1. Press “ ” & “ ” button to choose “F3”.
TEMP
TEMP
TEMP
2. Press MODE button. Press FAN button to to choose
parameter . Then press “ ” & “ ” button to select “2”.
MODE
TIMER OFF
FAN
4. Press TIMER ON button to confirm.
TIMER ON
General Anti-cold air function setting:
NOTE: The parameter of general anti-cold air is fixed regardless
of room temperature.

9
Speed control of indoor fan motor after the set
temperature reached
1. Press “ ” & “ ” button to choos “F4”.
TEMP
TEMP
2. Press MODE button. Then press “ ” & “ ” button to
select “1”, “2”, “3” or “4”.
MODE
Indicates stopping fan motor
Indicates operating at lowest fan speed
Indicates operating at setting fan speed
Indicates Termal function
3. Press TIMER ON button.
TIMER ON

10
1. Press “ ” & “ ” button to choose “F5”.
TEMP
TEMP
2. Press MODE button. Then press “ ” & “ ” button to
select “1”, “2” or “3”.
MODE
Indicates cancelling memory function.
Indicates the louver angle memory function is enabled
under switching off or power failure.
Indicates the louver angle memory function is enabled
under switching off, disabled under power failure.
3. Press TIMER ON button to confirm.
TIMER ON
Louver angle memory function

11
1. Press “ ” & “ ” button to choose “F6”.
TEMP
TEMP
2. Press MODE button. Then press “ ” & “ ” button to
select “HH” or “CH”. (HH: Heating only, CH: Cooling
& Heating)
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
Heating only or Cooling & heating setting
Cooling temperature compensation
Refrigerant leakage detection
1. Press “ ” & “ ” button to choose “F7”.
1. Press “ ” & “ ” button to choose “F8”.
2. Press MODE button. Then press “ ” & “ ” button to
choose the parameter in a range of -2ºC~2C.
2. Press MODE button. Then press “ ” & “ ” button to
choose “ON” or “OFF”.
TEMP
TEMP
MODE

12
Cleaning Filter Reminder
Filter Replacement Reminder
Lowest temperature setting
1. Press “ ” & “ ” button to choose “F9”.
1. Press “ ” & “ ” button to choose “E1”.
1. Press “ ” & “ ” button to choose “E2”.
TEMP
TEMP
TEMP
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
2. Press MODE button. Then press “ ” & “ ”button to
choose “ON” or “OFF”.
2. Press MODE button. Then press “ ” & “ ” button to
choose “ON” or “OFF”.
2. Press MODE button. Then press “ ” & “ ” button to
set the temperature in a range of 17ºC to 24C.

13
High temperature setting
1. Press “ ” & “ ” button to choose “E4”.
1. Press “ ” & “ ” button to choose “E5”.
1. Press “ ” & “ ” button to choose “E3”.
TEMP
TEMP
TEMP
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
2. Press MODE button. Then press “ ” & “ ” button to
choose “ON” or “OFF”.
2. Press MODE button. Then press “ ” & “ ” button to
choose “H” or “C”.
2. Press MODE button. Then press “ ” & “ ” button to
set the temperature in a range of 25ºC to 30ºC.
Special Anti-cold air function setting:
Priority setting of heating or cooling
(applicable for multi models)
: Heating mode first
: cooling mode first

14
Network Address setting
Capacity code selection
1. Press “ ” & “ ” button to choose “E6”.
1. Press “ ” & “ ” button to choose “E7”.
TEMP
TEMP
3. Press TIMER ON button to confirm.
2. Press MODE button. Then press “ ” & “ ” button to
choose the network address between 0 to 63 or “ ”.
“ ” Indicates cancelling the the adress modified by remote
controller (determined by code switch) .
2. Press MODE button. Then press “ ” & “ ” button to
choose the capacity code between 0~11.
(0~3: Reserved number), 4: 18K model, 5: 24K model,
7: 30K model, 8: 35K model, 9: 48K model, 10: 54K model
11: 60K model.
3. Press TIMER ON button to confirm.
--
--

15
Twins setting
1. Press “ ” & “ ” button to choose “E9”.
1. Press “ ” & “ ” button to choose “E8”.
TEMP
TEMP
Some functions of the remote controller will not
be available when the unit does not support them!
3. Press TIMER ON button to confirm.
3. Press TIMER ON button to confirm.
2. Press MODE button. Then press “ ” & “ ” button to
choose the value between 0 and 4.
2. Press MODE button. Then press “ ” & “ ” button to
choose 0(no twins), 1(main unit) or 2(subsidiary unit)
Static pressure setting
NOTES

16
Point check function
Enquiry information Displaying code Meaning
T1 T1 T1 temp.
T2 T2 T2 temp.
T3 T3 T3 temp.
T4
T2B T2B temp.
Tb
TP TP temp.
TP
TH
Targeted Frequency Targeted Frequency
Actual Frequency Actual Frequency
Indoor fan speed Indoor fan speed
Outdoor fan speed Outdoor fan speed
EXV opening angle EXV opening angle
Compressor continuous
running time
Compressor continuous
running time
Causes of compressor stop
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Causes of compressor stop
TH temp.
TH
FT
Fr
IF
OF
LA
CT
ST
A0
A1
b1
b0
b2
b3
b4
b5
b6
dL
Ac
Uo
Td
T4 T4 temp.
Press the “LED DISPLAY” button( “Mute” button for some
remote controllers) of remote controller three times and then
press “AIR DIRECTION” button ( “Swing” button for some
remote controllers) three times within 10 seconds, the buzzer
ring last 2 seconds,the air conditioner will enter the information
enquiry status. After that, press the “LED DISPLAY” button to
enquiry the next one information and press the “AIR
DIRECTION” button to enquiry the last one information. When
the air conditioner enter the information enquiry status, it will
display the code name in 2 seconds, the details are as follows:

17
Enquiry
information
Display
value Meaning Remark
Reserve
Reserve
Reserve
Reserve
Reserve
When the air condtioner enter the “information enquiry”
status, it will display the code value in the next 25s after
display name is displayed, the details are as follows,
T1,T2,T3,
T4,T2B,TP,
TH,
Targeted
Frequency,
Actual
Frequency
-1F,-1E,
-1d,-1c,
-1b,-1A
-25,-24,-23,-22,
-21,-20
-19-99
0
1,2,3,4
14-FF
0-FF
0-FF
0-FF
0-FF
0-FF
0-FF
0-FF
0-99
OFF
-19-99
A0,A1...A9 100,101......109
b0,b1...b9
c0,c1....c9
d0,d1...d9
E0,E1...E9
F0,F1...F9
110,111....119
120,121....129
130,131....139
140,141....149
150,151....159
1. All the displaying
temperature is actual
value.
O
2. All the temperature is C
no matter what kind of
remote controller is used.
3. T1,T2,T3,T4,T2B display
range:-25~70, TP display
range:-20~130.
4. Frequency display range:
0~159HZ.
5. If the actual value
exceeds the range, it will
display the maximum
value or minimum value.
Indoor fan
speed/
Outdoor
fan speed
Low speed,
Medium speed,
High speed,
Turbo
For some big capacity
motors.
Actual fan speed
=Display value
turns to decimal
value and then
multiply 10. The
unit is RPM.
For some small capacity
motors, display value is
from 14-FF(hexadecimal),
the corresponding fan
speed range is from
200-2550RPM.
EXV
opening
angle
Actual EXV
opening value=
Display value
turns to decimal
value and then
multiply 2.
Compressor
continuous
running
time
0-255 minutes If the actual value exceeds
the range, it will display the
maximum value or minimum
value.
Causes of
compressor
stop.
For the detailed
meaning, please
consult with
engineer
Decimal display

18
Enquiry
information
Display
value Meaning Remark
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
0-FF
0-FF
0-FF
0-FF
0-FF
0-FF
0-FF